Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Nucl Med ; 58(5): 791-798, 2017 May.
Article in English | MEDLINE | ID: mdl-27738005

ABSTRACT

A single-site prospective open-label clinical study with cyclotron-produced sodium 99mTc-pertechnetate (99mTc-NaTcO4) was performed in patients with indications for a thyroid scan to demonstrate the clinical safety and diagnostic efficacy of the drug and to confirm its equivalence with conventional 99mTc-NaTcO4 eluted from a generator. Methods:99mTc-NaTcO4 was produced from enriched 100Mo (99.815%) with a cyclotron (24 MeV; 2 h of irradiation) or supplied by a commercial manufacturer (bulk vial eluted from a generator). Eleven patients received 325 ± 29 (mean ± SD) MBq of the cyclotron-produced 99mTc-NaTcO4, whereas the age- and sex-matched controls received a comparable amount of the generator-derived tracer. Whole-body and thyroid planar images were obtained for each participant. In addition to the standard-energy window (140.5 keV ± 7.5%), data were acquired in lower-energy (117 keV ± 10%) and higher-energy (170 keV ± 10%) windows. Vital signs and hematologic and biochemical parameters were monitored before and after tracer administration. Results: Cyclotron-produced 99mTc-NaTcO4 showed organ and whole-body distributions identical to those of conventional 99mTc-NaTcO4 and was well tolerated. All images led to a clear final diagnosis. The fact that the number of counts in the higher-energy window was significantly higher for cyclotron-produced 99mTc-NaTcO4 did not influence image quality in the standard-energy window. Image definition in the standard-energy window with cyclotron-produced 99mTc was equivalent to that with generator-eluted 99mTc and had no particular features allowing discrimination between the 99mTc production methods. Conclusion: The systemic distribution, clinical safety, and imaging efficacy of cyclotron-produced 99mTc-NaTcO4 in humans provide supporting evidence for the use of this tracer as an equivalent for generator-eluted 99mTc-NaTcO4 in routine clinical practice.


Subject(s)
Cyclotrons/instrumentation , Radiation Injuries/etiology , Sodium Pertechnetate Tc 99m/adverse effects , Sodium Pertechnetate Tc 99m/pharmacokinetics , Thyroid Diseases/diagnostic imaging , Thyroid Diseases/metabolism , Adult , Aged , Aged, 80 and over , Equipment Design , Female , Humans , Isotope Labeling/instrumentation , Male , Metabolic Clearance Rate , Middle Aged , Organ Specificity , Radiation Injuries/diagnosis , Radiation Injuries/prevention & control , Radionuclide Generators , Radiopharmaceuticals/adverse effects , Radiopharmaceuticals/chemical synthesis , Radiopharmaceuticals/pharmacokinetics , Reproducibility of Results , Sensitivity and Specificity , Sodium Pertechnetate Tc 99m/chemical synthesis , Tissue Distribution
2.
J Nucl Med ; 56(10): 1600-8, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26205300

ABSTRACT

UNLABELLED: Cyclotron production of 99mTc is a promising route to supply 99mTc radiopharmaceuticals. Higher 99mTc yields can be obtained with medium-energy cyclotrons in comparison to those dedicated to PET isotope production. To take advantage of this capability, evaluation of the radioisotopic purity of 99mTc produced at medium energy (20-24 MeV) and its impact on image quality and dosimetry was required. METHODS: Thick 100Mo (99.03% and 99.815%) targets were irradiated with incident energies of 20, 22, and 24 MeV for 2 or 6 h. The targets were processed to recover an effective thickness corresponding to approximately 5-MeV energy loss, and the resulting sodium pertechnetate 99mTc was assayed for chemical, radiochemical, and radionuclidic purity. Radioisotopic content in final formulation was quantified using γ-ray spectrometry. The internal radiation dose for 99mTc-pertechnetate was calculated on the basis of experimentally measured values and biokinetic data in humans. Planar and SPECT imaging were performed using thin capillary and water-filled Jaszczak phantoms. RESULTS: Extracted sodium pertechnetate 99mTc met all provisional quality standards. The formulated solution for injection had a pH of 5.0-5.5, contained greater than 98% of radioactivity in the form of pertechnetate ion, and was stable for at least 24 h after formulation. Radioisotopic purity of 99mTc produced with 99.03% enriched 100Mo was greater than 99.0% decay corrected to the end of bombardment (EOB). The radioisotopic purity of 99mTc produced with 99.815% enriched 100Mo was 99.98% or greater (decay corrected to the EOB). The estimated dose increase relative to 99mTc without any radionuclidic impurities was below 10% for sodium pertechnetate 99mTc produced from 99.03% 100Mo if injected up to 6 h after the EOB. For 99.815% 100Mo, the increase in effective dose was less than 2% at 6 h after the EOB and less than 4% at 15 h after the EOB when the target was irradiated at an incident energy of 24 MeV. Image spatial resolution and contrast with cyclotron-produced 99mTc were equivalent to those obtained with 99mTc eluted from a conventional generator. CONCLUSION: Clinical-grade sodium pertechnetate 99mTc was produced with a cyclotron at medium energies. Quality control procedures and release specifications were drafted as part of a clinical trial application that received approval from Health Canada. The results of this work are intended to contribute to establishing a regulatory framework for using cyclotron-produced 99mTc in routine clinical practice.


Subject(s)
Cyclotrons , Radiochemistry/methods , Radiopharmaceuticals/chemistry , Sodium Pertechnetate Tc 99m/isolation & purification , Drug Contamination , Isotopes , Molybdenum , Phantoms, Imaging , Positron-Emission Tomography , Quality Control , Radiation Dosage , Radiopharmaceuticals/pharmacokinetics , Sodium Pertechnetate Tc 99m/chemistry , Sodium Pertechnetate Tc 99m/pharmacokinetics
SELECTION OF CITATIONS
SEARCH DETAIL
...