Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Med ; 92(2): 447-458, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38469890

ABSTRACT

PURPOSE: To introduce a tool (TensorFit) for ultrafast and robust metabolite fitting of MRSI data based on Torch's auto-differentiation and optimization framework. METHODS: TensorFit was implemented in Python based on Torch's auto-differentiation to fit individual metabolites in MRS spectra. The underlying time domain and/or frequency domain fitting model is based on a linear combination of metabolite spectroscopic response. The computational time efficiency and accuracy of TensorFit were tested on simulated and in vivo MRS data and compared against TDFDFit and QUEST. RESULTS: TensorFit demonstrates a significant improvement in computation speed, achieving a 165-times acceleration compared with TDFDFit and 115 times against QUEST. TensorFit showed smaller percentual errors on simulated data compared with TDFDFit and QUEST. When tested on in vivo data, it performed similarly to TDFDFit with a 2% better fit in terms of mean squared error while obtaining a 169-fold speedup. CONCLUSION: TensorFit enables fast and robust metabolite fitting in large MRSI data sets compared with conventional metabolite fitting methods. This tool could boost the clinical applicability of large 3D MRSI by enabling the fitting of large MRSI data sets within computation times acceptable in a clinical environment.


Subject(s)
Algorithms , Magnetic Resonance Spectroscopy , Humans , Magnetic Resonance Spectroscopy/methods , Computer Simulation , Software , Brain/metabolism , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Reproducibility of Results , Image Processing, Computer-Assisted/methods
2.
J Neuroradiol ; 51(1): 5-9, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37116782

ABSTRACT

Volumetric assessment based on structural MRI is increasingly recognized as an auxiliary tool to visual reading, also in examinations acquired in the clinical routine. However, MRI acquisition parameters can significantly influence these measures, which must be considered when interpreting the results on an individual patient level. This Technical Note shall demonstrate the problem. Using data from a dedicated experiment, we show the influence of two crucial sequence parameters on the GM/WM contrast and their impact on the measured volumes. A simulated contrast derived from acquisition parameters TI/TR may serve as surrogate and is highly correlated (r=0.96) with the measured contrast.


Subject(s)
Brain , Multiple Sclerosis , Humans , Brain/diagnostic imaging , Brain/pathology , Magnetic Resonance Imaging/methods , Atrophy/pathology
3.
Sci Rep ; 12(1): 16965, 2022 10 10.
Article in English | MEDLINE | ID: mdl-36216858

ABSTRACT

Extracting quantitative information of neuronal signals by non-invasive imaging is an outstanding challenge for understanding brain function and pathology. However, state-of-the-art techniques offer low sensitivity to deep electrical sources. Stimulus induced rotary saturation is a recently proposed magnetic resonance imaging sequence that detects oscillatory magnetic fields using a spin-lock preparation. Phantom experiments and simulations proved its efficiency and sensitivity, but the susceptibility of the method to field inhomogeneities is still not well understood. In this study, we simulated and analyzed the dynamic of three spin-lock preparations and their response to field inhomogeneities in the presence of a resonant oscillating field. We show that the composite spin-lock preparation is more robust against field variations within the double resonance effect. In addition, we tested the capability of the chosen composite spin-lock preparation to recover information about the spectral components of a composite signal. This study sets the bases to move one step further towards the clinical application of MR-based neuronal current imaging.


Subject(s)
Magnetic Fields , Magnetic Resonance Imaging , Magnetic Resonance Imaging/methods , Neurons/physiology , Phantoms, Imaging
SELECTION OF CITATIONS