1.
Phys Med Biol ; 68(24)2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37918026

ABSTRACT

Objective.In our previous work on image reconstruction for single-layer collimatorless scintigraphy, we developed the min-min weighted robust least squares (WRLS) optimization algorithm to address the challenge of reconstructing images when both the system matrix and the projection data are uncertain. Whereas the WRLS algorithm has been successful in two-dimensional (2D) reconstruction, expanding it to three-dimensional (3D) reconstruction is difficult since the WRLS optimization problem is neither smooth nor strongly-convex. To overcome these difficulties and achieve robust image reconstruction in the presence of system uncertainties and projection noise, we propose a generalized iterative method based on the maximum likelihood expectation maximization (MLEM) algorithm, hereinafter referred to as the Masked-MLEM algorithm.Approach.In the Masked-MLEM algorithm, only selected subsets ('masks') from the system matrix and the projection contribute to the image update to satisfy the constraints imposed by the system uncertainties. We validate the Masked-MLEM algorithm and compare it to the standard MLEM algorithm using experimental data obtained from both collimated and uncollimated imaging instruments, including parallel-hole collimated SPECT, 2D collimatorless scintigraphy, and 3D collimatorless tomography. Additionally, we conduct comprehensive Monte Carlo simulations for 3D collimatorless tomography to further validate the effectiveness of the Masked-MLEM algorithm in handling different levels of system uncertainties.Main results.The Masked-MLEM and standard MLEM reconstructions are similar in cases with negligible system uncertainties, whereas the Masked-MLEM algorithm outperforms the standard MLEM algorithm when the system matrix is an approximation. Importantly, the Masked-MLEM algorithm ensures reliable image reconstruction across varying levels of system uncertainties.Significance.With a good choice of system uncertainty and without requiring accurate knowledge of the actual system matrix, the Masked-MLEM algorithm yields more robust image reconstruction than the standard MLEM algorithm, effectively reducing the likelihood of erroneously reconstructing higher activities in regions without radioactive sources.


Subject(s)
Image Processing, Computer-Assisted , Motivation , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Tomography, Emission-Computed, Single-Photon/methods , Algorithms , Likelihood Functions
2.
Med Phys ; 50(6): 3726-3737, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36916755

ABSTRACT

BACKGROUND: Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. PURPOSE: With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. METHODS: We create a realistic model of our detector by using a combination of a Geant4 Application for Tomographic Emission (GATE) Monte Carlo simulation and a finite element model for the CZT response, accounting for low-energy tail effects in CZT that affects the sensitivity and the scatter correction. We implement a modified dual-energy-window scatter correction adapted for CZT. Other corrections for attenuation, detector and collimator response, and detector gaps and edges are also included. The images are reconstructed using the maximum-likelihood expectation-maximization. Detector and reconstruction performance are characterized with point sources, Derenzo phantoms, and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom for both 99m Tc and 177 Lu. RESULTS: Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. CONCLUSIONS: In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. The high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.


Subject(s)
Cadmium , Whole Body Imaging , Tomography, Emission-Computed, Single-Photon/methods , Phantoms, Imaging , Iodine Radioisotopes , Zinc
3.
IEEE Trans Radiat Plasma Med Sci ; 6(8): 904-915, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36338821

ABSTRACT

In vivo imaging of 225Ac is a major challenge in the development of targeted alpha therapy radiopharmaceuticals due to the extremely low injected doses. In this paper, we present the design of a multi-modality gamma camera that integrates both proximity and Compton imaging in order to achieve the demanding sensitivities required to image 225Ac with good image quality. We consider a dual-head camera, each of the heads consisting of two planar cadmium zinc telluride detectors acting as scatterer and absorber for Compton imaging, and with the scatterer practically in contact with the subject to allow for proximity imaging. We optimize the detector's design and characterize the detector's performance using Monte Carlo simulations. We show that Compton imaging can resolve features of up to 1.5 mm for hot rod phantoms with an activity of 1 µCi, and can reconstruct 3D images of a mouse injected with 0.5 µCi after a 15 minutes exposure and with a single bed position, for both 221Fr and 213Bi. Proximity imaging is able to resolve two 1 mm-radius sources of less than 0.1 µCi separated by 1 cm and at 1 mm from the detector, as well as it can provide planar images of 221Fr and 213Bi biodistributions of the mouse phantom in 5 minutes.

4.
Phys Med Biol ; 67(22)2022 11 18.
Article in English | MEDLINE | ID: mdl-36317316

ABSTRACT

Objective.The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including137Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as anin situdose calibration method.Approach.We irradiated mouse carcasses and 3D-printed mouse biophantoms in a137Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice.Main Results.Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to -9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty.Significance.Our results suggest that 320 kVp irradiation is a good candidate to substitute137Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need forin situcalibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Finally, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.


Subject(s)
Calibration , Animals , Mice , Monte Carlo Method , Phantoms, Imaging , X-Rays