Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters











Publication year range
1.
Aust Crit Care ; 33(3): 244-249, 2020 05.
Article in English | MEDLINE | ID: mdl-32349888

ABSTRACT

BACKGROUND: Patients may require vasoactive medication after cardiac surgery. The effect and safety profile of exercise on haemodynamic parameters in these patients is unclear. OBJECTIVES: The objective of this study was to measure the effect of upright positioning and low-level exercise on haemodynamic parameters in patients after cardiac surgery who were receiving vasoactive therapy and to determine the incidence of adverse events. METHODS: This was a prospective, single-centre, observational study conducted in an adult intensive care unit of a tertiary, cardiothoracic university-affiliated hospital in Australia. The Flotrac-Vigileo™ system was used to measure haemodynamic changes, including cardiac output, cardiac index, and stroke volume. Normally distributed variables are presented as n (%) and mean (standard deviation), and non-normally distributed variables are presented as median [interquartile range]. RESULTS: There were a total of 20 participants: 16 (80%) male, with a mean age of 65.9 (10.6) years. Upright positioning caused significant increases (p = 0.018) in the mean arterial pressure (MAP), with MAP readings increasing from baseline (supine), from 72.31 (11.91) mmHg to 77.44 (9.55) mmHg when back in supine. There were no clinically significant changes in cardiac output, heart rate, stroke volume, or cardiac index with upright positioning. The incidence of adverse events was low (5%). The adverse event was transient hypotension of low severity. CONCLUSIONS: Low-level exercise in patients after cardiac surgery receiving vasoactive medication was well tolerated with a low incidence of adverse events and led to significant increases in MAP. Upright positioning and low-level exercise appeared safe and feasible in this patient cohort.


Subject(s)
Cardiac Surgical Procedures/rehabilitation , Exercise Therapy , Hemodynamic Monitoring/instrumentation , Intensive Care Units , Aged , Australia , Female , Humans , Male , Patient Positioning , Prospective Studies
2.
J Crit Care ; 49: 77-83, 2019 02.
Article in English | MEDLINE | ID: mdl-30388492

ABSTRACT

PURPOSE: Endotracheal suctioning (ES) of mechanically ventilated patients decreases end-expiratory lung volume (EELV). Manual hyperinflation (MHI) and ventilator hyperinflation (VHI) may restore EELV post-ES but it remains unknown which method is most effective. The primary aim was to compare the efficacy of MHI and VHI in restoring EELV post-ES. MATERIALS AND METHODS: ES was performed on mechanically ventilated intensive care patients, followed by MHI or VHI, in a randomised crossover design. The washout period between interventions was 1 h. End-expiratory lung impedance (EELI), measured by electrical impedance tomography, was recorded at baseline, during ES, during hyperinflation and 1, 5, 15 and 30 min post-hyperinflation. RESULTS: Nine participants were studied. ES decreased EELI by 1672z (95% CI, 1204 to 2140) from baseline. From baseline, MHI increased EELI by 1154z (95% CI, 977 to 1330) while VHI increased EELI by 769z (95% CI, 457 to 1080). Five minutes post-VHI, EELI remained 528z (95% CI, 4 to 1053) above baseline. Fifteen minutes post-MHI, EELI remained 351z (95% CI, 111 to 592) above baseline. At subsequent time-points, EELI returned to baseline. CONCLUSIONS: MHI and VHI effectively restore EELV above baseline post-ES and should be considered post suctioning.


Subject(s)
Intubation, Intratracheal/adverse effects , Lung/physiology , Respiration, Artificial/methods , Tidal Volume/physiology , Cross-Over Studies , Female , Humans , Male , Middle Aged , Pilot Projects , Tomography, X-Ray Computed
4.
Heart Lung ; 47(2): 81-86, 2018.
Article in English | MEDLINE | ID: mdl-29246774

ABSTRACT

RATIONALE: Consensus recommendations have been developed to guide exercise rehabilitation of mechanically ventilated patients in the intensive care unit. OBJECTIVE: This study aimed to investigate the safety of exercise rehabilitation of mechanically ventilated patients and evaluate the consensus recommendations. METHODS: This was a prospective, single-centre, cohort study conducted in a specialist cardiothoracic intensive care unit of a tertiary, university affiliated hospital in Australia. RESULTS: 91 mechanically ventilated participants; 54 (59.3%) male; mean age of 56.52 (16.3) years; were studied with 809 occasions of service recorded. Ten (0.0182%) minor adverse events were recorded, with only one adverse event occurring when a patient was receiving moderate level of vasoactive support. CONCLUSIONS: The consensus recommendations are a useful tool in guiding safe exercise rehabilitation of mechanically ventilated patients. Our findings suggest that there is further scope to safely commence exercise rehabilitation in patients receiving vasoactive support.


Subject(s)
Exercise Therapy , Intensive Care Units , Respiration, Artificial , Aged , Australia , Exercise Therapy/adverse effects , Female , Humans , Length of Stay , Male , Middle Aged , Prospective Studies , Respiration, Artificial/adverse effects , Tertiary Care Centers , Vasoconstrictor Agents/therapeutic use
5.
J Crit Care ; 40: 164-170, 2017 08.
Article in English | MEDLINE | ID: mdl-28411422

ABSTRACT

PURPOSE: Speaking valves (SV) are used infrequently in tracheostomised ICU patients due to concerns regarding their putative effect on lung recruitment. A recent study in cardio-thoracic population demonstrated increased end-expiratory lung volumes during and post SV use without examining if the increase in end-expiratory lung impedance (EELI) resulted in alveolar recruitment or potential hyperinflation in discrete loci. MATERIALS AND METHODS: A secondary analysis of Electrical Impedance Tomography (EIT) data from a previous study was conducted. EELI distribution and tidal variation (TV) were assessed with a previously validated tool. A new tool was used to investigate ventilated surface area (VSA) and regional ventilation delay (RVD) as indicators of alveolar recruitment. RESULTS: The increase in EELI was found to be uniform with significant increase across all lung sections (p<0.001). TV showed an initial non-significant decrease (p=0.94) with subsequent increase significantly above baseline (p<0.001). VSA and RVD showed non-significant changes during and post SV use. CONCLUSIONS: These findings indicate that hyperinflation did not occur with SV use, which is supported by previously published data on respiratory parameters. These data along with obvious psychological benefits to patients are encouraging towards safe use of SVs in this critically ill cardio-thoracic patient population. TRIAL REGISTRATION: Anna-Liisa Sutt, Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12615000589583. 4/6/2015.


Subject(s)
Critical Care/methods , Respiration, Artificial/instrumentation , Tracheostomy/instrumentation , Ventilator Weaning/methods , Adult , Aged , Australia , Electric Impedance , Female , Humans , Larynx, Artificial , Lung/physiology , Male , Middle Aged , Positive-Pressure Respiration/methods , Respiration , Respiration, Artificial/methods , Respiratory Function Tests , Tidal Volume/physiology , Tomography/methods , Tomography, X-Ray Computed
6.
Can Respir J ; 2016: 2471207, 2016.
Article in English | MEDLINE | ID: mdl-27445522

ABSTRACT

Background. Lung transplantation is the optimal treatment for end stage lung disease. Donor shortage necessitates single-lung transplants (SLT), yet minimal data exists regarding regional ventilation in diseased versus transplanted lung measured by Electrical Impedance Tomography (EIT). Method. We aimed to determine regional ventilation in six SLT outpatients using EIT. We assessed end expiratory volume and tidal volumes. End expiratory lung impedance (EELI) and Global Tidal Variation of Impedance were assessed in supine, right lateral, left lateral, sitting, and standing positions in transplanted and diseased lungs. A mixed model with random intercept per subject was used for statistical analysis. Results. EELI was significantly altered between diseased and transplanted lungs whilst lying on right and left side. One patient demonstrated pendelluft between lungs and was therefore excluded for further comparison of tidal variation. Tidal variation was significantly higher in the transplanted lung for the remaining five patients in all positions, except when lying on the right side. Conclusion. Ventilation to transplanted lung is better than diseased lung, especially in lateral positions. Positioning in patients with active unilateral lung pathologies will be implicated. This is the first study demonstrating changes in regional ventilation, associated with changes of position between transplanted and diseased lung.


Subject(s)
Lung Transplantation , Respiration , Electric Impedance , Female , Humans , Male , Middle Aged , Tomography
7.
Crit Care ; 20: 91, 2016 Apr 01.
Article in English | MEDLINE | ID: mdl-27038617

ABSTRACT

BACKGROUND: Patients who require positive pressure ventilation through a tracheostomy are unable to phonate due to the inflated tracheostomy cuff. Whilst a speaking valve (SV) can be used on a tracheostomy tube, its use in ventilated ICU patients has been inhibited by concerns regarding potential deleterious effects to recovering lungs. The objective of this study was to assess end expiratory lung impedance (EELI) and standard bedside respiratory parameters before, during and after SV use in tracheostomised patients weaning from mechanical ventilation. METHODS: A prospective observational study was conducted in a cardio-thoracic adult ICU. 20 consecutive tracheostomised patients weaning from mechanical ventilation and using a SV were recruited. Electrical Impedance Tomography (EIT) was used to monitor patients' EELI. Changes in lung impedance and standard bedside respiratory data were analysed pre, during and post SV use. RESULTS: Use of in-line SVs resulted in significant increase of EELI. This effect grew and was maintained for at least 15 minutes after removal of the SV (p < 0.001). EtCO2 showed a significant drop during SV use (p = 0.01) whilst SpO2 remained unchanged. Respiratory rate (RR (breaths per minute)) decreased whilst the SV was in situ (p <0.001), and heart rate (HR (beats per minute)) was unchanged. All results were similar regardless of the patients' respiratory requirements at time of recruitment. CONCLUSIONS: In this cohort of critically ill ventilated patients, SVs did not cause derecruitment of the lungs when used in the ventilator weaning period. Deflating the tracheostomy cuff and restoring the airflow via the upper airway with a one-way valve may facilitate lung recruitment during and after SV use, as indicated by increased EELI. TRIAL REGISTRATION: Anna-Liisa Sutt, Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12615000589583. 4/6/2015.


Subject(s)
Respiration, Artificial/methods , Speech/physiology , Tracheostomy/methods , Ventilator Weaning/methods , Adult , Aged , Cohort Studies , Communication , Female , Humans , Intensive Care Units/statistics & numerical data , Male , Middle Aged , Respiration, Artificial/adverse effects , Respiration, Artificial/statistics & numerical data , Tracheostomy/adverse effects , Tracheostomy/statistics & numerical data , Ventilator Weaning/adverse effects
8.
Crit Care ; 18(6): 658, 2014 Dec 04.
Article in English | MEDLINE | ID: mdl-25475522

ABSTRACT

INTRODUCTION: The aim of this study was to develop consensus recommendations on safety parameters for mobilizing adult, mechanically ventilated, intensive care unit (ICU) patients. METHODS: A systematic literature review was followed by a meeting of 23 multidisciplinary ICU experts to seek consensus regarding the safe mobilization of mechanically ventilated patients. RESULTS: Safety considerations were summarized in four categories: respiratory, cardiovascular, neurological and other. Consensus was achieved on all criteria for safe mobilization, with the exception being levels of vasoactive agents. Intubation via an endotracheal tube was not a contraindication to early mobilization and a fraction of inspired oxygen less than 0.6 with a percutaneous oxygen saturation more than 90% and a respiratory rate less than 30 breaths/minute were considered safe criteria for in- and out-of-bed mobilization if there were no other contraindications. At an international meeting, 94 multidisciplinary ICU clinicians concurred with the proposed recommendations. CONCLUSION: Consensus recommendations regarding safety criteria for mobilization of adult, mechanically ventilated patients in the ICU have the potential to guide ICU rehabilitation whilst minimizing the risk of adverse events.


Subject(s)
Consensus , Critical Illness/rehabilitation , Early Ambulation/standards , Patient Safety/standards , Practice Guidelines as Topic/standards , Respiration, Artificial/standards , Critical Care/methods , Critical Care/standards , Critical Illness/epidemiology , Early Ambulation/methods , Female , Humans , Male , Respiration, Artificial/methods
9.
Respir Care ; 59(10): 1583-9, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24847096

ABSTRACT

BACKGROUND: Head-of-bed elevation (HOBE) has been shown to assist in reducing respiratory complications associated with mechanical ventilation; however, there is minimal research describing changes in end-expiratory lung volume. This study aims to investigate changes in end-expiratory lung volume in a supine position and 2 levels of HOBE. METHODS: Twenty postoperative cardiac surgery subjects were examined using electrical impedance tomography. End-expiratory lung impedance (EELI) was recorded as a surrogate measurement of end-expiratory lung volume in a supine position and at 20° and then 30°. RESULTS: Significant increases in end-expiratory lung volume were seen at both 20° and 30° HOBE in all lung regions, except the anterior, with the largest changes from baseline (supine) seen at 30°. From baseline to 30° HOBE, global EELI increased by 1,327 impedance units (95% CI 1,080-1,573, P < .001). EELI increased by 1,007 units (95% CI 880-1,134, P < .001) in the left lung region and by 320 impedance units (95% CI 188-451, P < .001) in the right lung. Posterior increases of 1,544 impedance units (95% CI 1,405-1,682, P < .001) were also seen. EELI decreased anteriorly, with the largest decreases occurring at 30° (-335 impedance units, 95% CI -486 to -183, P < .001). CONCLUSIONS: HOBE significantly increases global and regional end-expiratory lung volume; therefore, unless contraindicated, all mechanically ventilated patients should be positioned with HOBE.


Subject(s)
Beds , Cardiac Surgical Procedures , Respiration, Artificial , Supine Position/physiology , Tidal Volume/physiology , Female , Humans , Male , Middle Aged , Postoperative Care , Prospective Studies
10.
Respir Care ; 59(4): 497-503, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24046466

ABSTRACT

BACKGROUND: Airway suctioning in mechanically ventilated patients is required to maintain airway patency. Closed suction catheters (CSCs) minimize lung volume loss during suctioning but require cleaning post-suction. Despite their widespread use, there is no published evidence examining lung volumes during CSC cleaning. The study objectives were to quantify lung volume changes during CSC cleaning and to determine whether these changes were preventable using a CSC with a valve in situ between the airway and catheter cleaning chamber. METHODS: This prospective randomized crossover study was conducted in a metropolitan tertiary ICU. Ten patients mechanically ventilated via volume-controlled synchronized intermittent mandatory ventilation (SIMV-VC) and requiring manual hyperinflation (MHI) were included in this study. CSC cleaning was performed using 2 different brands of CSC (one with a valve [Ballard Trach Care 72, Kimberly-Clark, Roswell, Georgia] and one without [Portex Steri-Cath DL, Smiths Medical, Dublin, Ohio]). The maneuvers were performed during both SIMV-VC and MHI. Lung volume change was measured via impedance change using electrical impedance tomography. A mixed model was used to compare the estimated means. RESULTS: During cleaning of the valveless CSC, significant decreases in lung impedance occurred during MHI (-2563 impedance units, 95% CI 2213-2913, P < .001), and significant increases in lung impedance occurred during SIMV (762 impedance units, 95% CI 452-1072, P < .001). In contrast, cleaning of the CSC with a valve in situ resulted in non-significant lung volume changes and maintenance of normal ventilation during MHI and SIMV-VC, respectively (188 impedance units, 95% CI -136 to 511, P = .22; and 22 impedance units, 95% CI -342 to 299, P = .89). CONCLUSIONS: When there is no valve between the airway and suction catheter, cleaning of the CSC results in significant derangements in lung volume. Therefore, the presence of such a valve should be considered essential in preserving lung volumes and uninterrupted ventilation in mechanically ventilated patients.


Subject(s)
Catheters , Disinfection , Electric Impedance , Intubation, Intratracheal/instrumentation , Lung Volume Measurements , Tomography , Cross-Over Studies , Female , Humans , Intensive Care Units , Male , Middle Aged , Prospective Studies , Respiration, Artificial , Suction/instrumentation
11.
J Crit Care ; 27(6): 742.e1-7, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23102530

ABSTRACT

PURPOSE: Endotracheal suctioning causes significant lung derecruitment. Closed suction (CS) minimizes lung volume loss during suction, and therefore, volumes are presumed to recover more quickly postsuctioning. Conflicting evidence exists regarding this. We examined the effects of open suction (OS) and CS on lung volume loss during suctioning, and recovery of end-expiratory lung volume (EELV) up to 30 minutes postsuction. MATERIAL AND METHODS: Randomized crossover study examining 20 patients postcardiac surgery. CS and OS were performed in random order, 30 minutes apart. Lung impedance was measured during suction, and end-expiratory lung impedance was measured at baseline and postsuctioning using electrical impedance tomography. Oximetry, partial pressure of oxygen in the alveoli/fraction of inspired oxygen ratio and compliance were collected. RESULTS: Reductions in lung impedance during suctioning were less for CS than for OS (mean difference, -905 impedance units; 95% confidence interval [CI], -1234 to -587; P < .001). However, at all points postsuctioning, EELV recovered more slowly after CS than after OS. There were no statistically significant differences in the other respiratory parameters. CONCLUSIONS: Closed suctioning minimized lung volume loss during suctioning but, counterintuitively, resulted in slower recovery of EELV postsuction compared with OS. Therefore, the use of CS cannot be assumed to be protective of lung volumes postsuctioning. Consideration should be given to restoring EELV after either suction method via a recruitment maneuver.


Subject(s)
Respiration, Artificial/methods , Suction/methods , Adult , Aged , Blood Gas Analysis , Cross-Over Studies , Electric Impedance , Female , Humans , Lung Volume Measurements , Male , Middle Aged , Tidal Volume
SELECTION OF CITATIONS
SEARCH DETAIL