Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
J Neuroeng Rehabil ; 21(1): 53, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38600582

ABSTRACT

A systematic review was conducted to determine the trends in devices and parameters used for brain photobiomodulation (PBM). The revised studies included clinical and cadaveric approaches, in which light stimuli were applied to the head and/or neck. PubMed, Scopus, Web of Science and Google Scholar databases were used for the systematic search. A total of 2133 records were screened, from which 97 were included in this review. The parameters that were extracted and analysed in each article were the device design, actuation area, actuation site, wavelength, mode of operation, power density, energy density, power output, energy per session and treatment time. To organize device information, 11 categories of devices were defined, according to their characteristics. The most used category of devices was laser handpieces, which relate to 21% of all devices, while 28% of the devices were not described. Studies for cognitive function and physiological characterisation are the most well defined ones and with more tangible results. There is a lack of consistency when reporting PBM studies, with several articles under defining the stimulation protocol, and a wide variety of parameters used for the same health conditions (e.g., Alzheimer's or Parkinson's disease) resulting in positive outcomes. Standardization for the report of these studies is warranted, as well as sham-controlled comparative studies to determine which parameters have the greatest effect on PBM treatments for different neurological conditions.


Subject(s)
Low-Level Light Therapy , Humans , Low-Level Light Therapy/methods , Brain , Cognition , Lasers
2.
Biomimetics (Basel) ; 9(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38534840

ABSTRACT

Peri-implantitis continues to be one of the major reasons for implant failure. We propose a new approach to the incorporation of MTA into zirconia implant surfaces with Nd:YAG laser and investigate the biological and the microbiological responses of peri-implant cells. Discs of zirconia stabilized with yttria and titanium were produced according to the following four study groups: Nd:YAG laser-textured zirconia coated with MTA (Zr MTA), Nd:YAG laser-textured zirconia (Zr textured), polished zirconia discs, and polished titanium discs (Zr and Ti). Surface roughness was evaluated by contact profilometry. Human osteoblasts (hFOB), gingival fibroblasts (HGF hTERT) and S. oralis were cultured on discs. Cell adhesion and morphology, cell differentiation markers and bacterial growth were evaluated. Zr textured roughness was significantly higher than all other groups. SEM images reveal cellular adhesion at 1 day in all samples in both cell lines. Osteoblasts viability was lower in the Zr MTA group, unlike fibroblasts viability, which was shown to be higher in the Zr MTA group compared with the Zr textured group at 3 and 7 days. Osteocalcin and IL-8 secretion by osteoblasts were higher in Zr MTA. The Zr textured group showed higher IL-8 values released by fibroblasts. No differences in S. oralis CFUs were observed between groups. The present study suggests that zirconia implant surfaces coated with MTA induced fibroblast proliferation and osteoblast differentiation; however, they did not present antibacterial properties.

3.
Biomedicines ; 12(2)2024 Feb 03.
Article in English | MEDLINE | ID: mdl-38397963

ABSTRACT

Among the adjunctive procedures to accelerate orthodontic tooth movement (OTM), ultrasound (US) is a nonsurgical form of mechanical stimulus that has been explored as an alternative to the currently available treatments. This study aimed to clarify the role of US in OTM by exploring different stimulation parameters and their effects on the biological responses of cells involved in OTM. Human fetal osteoblasts and periodontal ligament fibroblasts cell lines were stimulated with US at 1.0 and 1.5 MHz central frequencies and power densities of 30 and 60 mW/cm2 in continuous mode for 5 and 10 min. Cellular proliferation, metabolic activity and protein expression were analyzed. The US parameters that significantly improved the metabolic activity were 1.0 MHz at 30 mW/cm2 for 5 min and 1.0 MHz at 60 mW/cm2 for 5 and 10 min for osteoblasts; and 1.0 MHz at 30 mW/cm2 for 5 min and 1.5 MHz at 60 mW/cm2 for 5 and 10 min for fibroblasts. By stimulating with these parameters, the expression of alkaline phosphatase was maintained, while osteoprotegerin synthesis was induced after three days of US stimulation. The US stimulation improved the biological activity of both osteoblasts and periodontal ligament fibroblasts, inducing their osteogenic differentiation.

4.
Biomedicines ; 12(1)2024 Jan 14.
Article in English | MEDLINE | ID: mdl-38255285

ABSTRACT

Numerous pieces of evidence have supported the therapeutic potential of photobiomodulation (PBM) to modulate bone remodeling on mechanically stimulated teeth, proving PBM's ability to be used as a coadjuvant treatment to accelerate orthodontic tooth movement (OTM). However, there are still uncertainty and discourse around the optimal PBM protocols, which hampers its optimal and consolidated clinical applicability. Given the differential expression and metabolic patterns exhibited in the tension and compression sides of orthodontically stressed teeth, it is plausible that different types of irradiation may be applied to each side of the teeth. In this sense, this study aimed to design and implement an optimization protocol to find the most appropriate PBM parameters to stimulate specific bone turnover processes. To this end, three levels of wavelength (655, 810 and 940 nm), two power densities (5 and 10 mW/cm2) and two regimens of single and multiple sessions within three consecutive days were tested. The biological response of osteoblasts and periodontal ligament (PDL) fibroblasts was addressed by monitoring the PBM's impact on the cellular metabolic activity, as well as on key bone remodeling mediators, including alkaline phosphatase (ALP), osteoprotegerin (OPG) and receptor activator of nuclear factor κ-B ligand (RANK-L), each day. The results suggest that daily irradiation of 655 nm delivered at 10 mW/cm2, as well as 810 and 940 nm light at 5 mW/cm2, lead to an increase in ALP and OPG, potentiating bone formation. In addition, irradiation of 810 nm at 5 mW/cm2 delivered for two consecutive days and suspended by the third day promotes a downregulation of OPG expression and a slight non-significant increase in RANK-L expression, being suitable to stimulate bone resorption. Future studies in animal models may clarify the impact of PBM on bone formation and resorption mediators for longer periods and address the possibility of testing different stimulation periodicities. The present in vitro study offers valuable insights into the effectiveness of specific PBM protocols to promote osteogenic and osteoclastogenesis responses and therefore its potential to stimulate bone formation on the tension side and bone resorption on the compression side of orthodontically stressed teeth.

5.
J Mech Behav Biomed Mater ; 151: 106353, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38194785

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the influence of the thickness of resin-matrix composite blocks manufactured by CAD-CAM on the light transmittance towards different resin-matrix cements or flowable composites. METHODS: Sixty specimens of resin-matrix composite CAD-CAM blocks reinforced with 89 wt% inorganic fillers were cross-sectioned with 2 or 3 mm thicknesses. The specimens were conditioned with adhesive system and divided in groups according to the luting material, namely: two dual-cured resin-matrix cements, two traditional flowable resin-matrix composites, and one thermal-induced flowable resin-matrix composite. Specimens were light-cured at 900 mW/cm2 for 40s. Light transmittance assays were preformed using a spectrophotometer with an integrated monochromator before and after light-curing. Microstructural analysis was performed by optical and scanning electron microscopy (SEM). Nanoindentation tests were performed to evaluate mechanical properties for indirect evaluation of degree of monomers conversion. RESULTS: Optical and SEM images revealed low thickness values for the cementation interfaces for the traditional flowable resin-matrix composite. The cement thickness increased with the size and content of inorganic fillers. The highest light transmittance was recorded for the onlay blocks cemented with the traditional flowable resin-matrix composites while a group cemented with the dual-cured resin-matrix cement revealed the lowest light transmittance. The elastic modulus and hardness increased for specimens with high content of inorganic fillers as well as it increased in function of the light transmittance. CONCLUSIONS: The light transmittance of flowable resin-matrix composites was higher than that for resin-matrix cement after cementation to resin-matrix composites blocks. The type, size, and content of inorganic fillers of the luting material affected the thickness of the cement layer and light transmittance through the materials. CLINICAL RELEVANCE: On chair-side light curing, the transmission of visible light can be interfered by the chemical composition and viscosity of the luting materials. The increase in size and content of inorganic fillers of resin-matrix composites and luting materials can decrease the light transmittance leading to inefficient polymerization.


Subject(s)
Composite Resins , Light-Curing of Dental Adhesives , Materials Testing , Surface Properties , Light-Curing of Dental Adhesives/methods , Composite Resins/chemistry , Resin Cements/chemistry
6.
Head Face Med ; 19(1): 55, 2023 Dec 18.
Article in English | MEDLINE | ID: mdl-38110992

ABSTRACT

OBJECTIVE: The main aim of this study was to evaluate the morphological aspects and distribution of granules composed of deproteinized bovine bone mineral (DBBM) and human dentin-derived bone graft (HDBG) into a putty consistency mixture. MATERIALS AND METHODS: DBBM or HDBG were mixed with an alginate-based hydrogel at two different granule/hydrogel ratio (1:1 and 1:3) and divided into four test groups while two control groups were composed of DBBM or HDBG free of hydrogel. Groups of specimens were cross-sectioned for morphological evaluation by scanning electron microscopy (SEM) at backscattered electrons mode. Details on the dimensions and pores' size of DBBM and HDBG were evaluated after mixing different amounts of particles and alginate-based hydrogels. RESULTS: Microscopic analyses revealed a size of DBBM granules ranging from 750 up to 1600 µm while HDBG particles showed particle size ranging from 375 up to 1500 µm. No statistical differences were identified regarding the size of granules (p > 0.5). The mean values of pores' size of DBBM particles were noticed at around 400 µm while HDBG particles revealed micro-scale pores of around 1-3 µm promoted by the dentin tubules (p < 0.05). The lowest distance between particles was at 125 µm for HDBG and 250 µm for DBBM when the particle content was increased. On decreasing the particles' content, the distance between particles was larger for DBBM (~ 1000 µm) and HDBG (~ 1100 µm). In fact, statistically significant differences were found when the content of granules increased (p < 0.05). CONCLUSIONS: The increased content of bioactive ceramic granules in a putty consistency mixture with hydrogel decreased the space among granules that can promote a high ceramic density and stimulate the bone growth over the healing process. Macro-scale pores on bovine bone mineral granules stimulate the formation of blood vessels and cell migration while the micro-scale pores of dentin-derived granules are proper for the adsorption of proteins and growth of osteogenic cells on the bone healing process. CLINICAL SIGNIFICANCE: A high amount of bioactive ceramic granules should be considered when mixing with hydrogels as a putty material since that result in small spaces among granules maintaining the bone volume over the bone healing process. Deproteinized bovine bone mineral granules have macro-scale pores providing an enhanced angiogenesis while dentin-derived granules possess only micro-scale pores for the adsorption of proteins and proliferation of osteogenic cells on the bone healing process. Further studies should evaluate the combination of different bioactive ceramic materials for enhanced bone healing.


Subject(s)
Bone Substitutes , Bone Transplantation , Humans , Animals , Cattle , Bone Transplantation/methods , Minerals , Alginates , Hydrogels , Dentin , Bone Regeneration
7.
Biomimetics (Basel) ; 8(4)2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37622943

ABSTRACT

Barium titanate (BaTiO3) piezoelectric ceramic may be a potential alternative for promoting osseointegration due to its piezoelectric properties similar to bone electric potentials generated in loading function. In this sense, the aim of this in vitro study was to evaluate the cellular response of human osteoblasts and gingival fibroblasts as well as the impact on S. oralis when in contact with BaTiO3 functionalized zirconia implant surfaces with piezoelectric properties. Zirconia discs with BaTiO3 were produced and contact poling (piezo activation) was performed. Osteoblasts (hFOB 1.19), fibroblasts (HGF hTERT) and S. oralis were culture on discs. Cell viability and morphology, cell differentiation markers, bacterial adhesion and growth were evaluated. The present study suggests that zirconia composite surfaces with the addition of piezoelectric BaTiO3 are not cytotoxic to peri-implant cells. Also, they seem to promote a faster initial osteoblast differentiation. Moreover, these surfaces may inhibit the growth of S. oralis by acting as a bacteriostatic agent over time. Although the piezoelectric properties do not affect the cellular inflammatory profile, they appear to enable the initial adhesion of bacteria, however this is not significant over the entire testing period. Furthermore, the addition of non-poled BaTiO3 to zirconia may have a potential reduction effect on IL-6 mediated-inflammatory activity in fibroblasts.

8.
Clin Oral Investig ; 27(9): 5679-5693, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37592003

ABSTRACT

OBJECTIVES: The aim of this in vitro study was to evaluate the light transmission through five different resin-matrix composites regarding the inorganic filler content. METHODS: Resin-matrix composite disc-shaped specimens were prepared on glass molds. Three traditional resin-matrix composites contained inorganic fillers at 74, 80, and 89 wt. % while two flowable composites revealed 60 and 62.5 wt. % inorganic fillers. Light transmission through the resin-matrix composites was assessed using a spectrophotometer with an integrated monochromator before and after light curing for 10, 20, or 40s. Elastic modulus and nanohardness were evaluated through nanoindentation's tests, while Vicker's hardness was measured by micro-hardness assessment. Chemical analyses were performed by FTIR and EDS, while microstructural analysis was conducted by optical microscopy and scanning electron microscopy. Data were evaluated using two-way ANOVA and Tukey's test (p < 0.05). RESULTS: After polymerization, optical transmittance increased for all specimens above 650-nm wavelength irradiation since higher light exposure time leads to increased light transmittance. At 20- or 40-s irradiation, similar light transmittance was recorded for resin composites with 60, 62, 74, or 78-80 wt. % inorganic fillers. The lowest light transmittance was recorded for a resin-matrix composite reinforced with 89 wt. % inorganic fillers. Thus, the size of inorganic fillers ranged from nano- up to micro-scale dimensions and the high content of micro-scale inorganic particles can change the light pathway and decrease the light transmittance through the materials. At 850-nm wavelength, the average ratio between polymerized and non-polymerized specimens increased by 1.6 times for the resin composite with 89 wt. % fillers, while the composites with 60 wt. % fillers revealed an increased ratio by 3.5 times higher than that recorded at 600-nm wavelength. High mean values of elastic modulus, nano-hardness, and micro-hardness were recorded for the resin-matrix composites with the highest inorganic content. CONCLUSIONS: A high content of inorganic fillers at 89 wt.% decreased the light transmission through resin-matrix composites. However, certain types of fillers do not interfere on the light transmission, maintaining an optimal polymerization and the physical properties of the resin-matrix composites. CLINICAL SIGNIFICANCE: The type and content of inorganic fillers in the chemical composition of resin-matrix composites do affect their polymerization mode. As a consequence, the clinical performance of resin-matrix composites can be compromised, leading to variable physical properties and degradation.


Subject(s)
Dentistry , Glass , Chromatography, Gas , Elastic Modulus , Hardness
9.
Bioengineering (Basel) ; 10(7)2023 Jul 04.
Article in English | MEDLINE | ID: mdl-37508826

ABSTRACT

There is no consensus on how to measure shoulder joint laxity and results reported in the literature are not well systematized for the available shoulder arthrometer devices. This systematic review aims to summarize the results of currently available shoulder arthrometers for measuring glenohumeral laxity in individuals with healthy or injured shoulders. Searches were conducted on the PubMed, EMBASE, and Web of Science databases to identify studies that measure glenohumeral laxity with arthrometer-assisted assessment. The mean and standard deviations of the laxity measurement from each study were compared based on the type of population and arthrometer used. Data were organized according to the testing characteristics. A total of 23 studies were included and comprised 1162 shoulders. Populations were divided into 401 healthy individuals, 278 athletes with asymptomatic shoulder, and 134 individuals with symptomatic shoulder. Sensors were the most used method for measuring glenohumeral laxity and stiffness. Most arthrometers applied an external force to the humeral head or superior humerus by a manual-assisted mechanism. Glenohumeral laxity and stiffness were mostly assessed in the sagittal plane. There is substantial heterogeneity in glenohumeral laxity values that is mostly related to the arthrometer used and the testing conditions. This variability can lead to inconsistent results and influence the diagnosis and treatment decision-making.

10.
J Mech Behav Biomed Mater ; 143: 105943, 2023 07.
Article in English | MEDLINE | ID: mdl-37276650

ABSTRACT

Surface modification of yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) using lasers for adhesion enhancement with resin-matrix cement has been increasingly explored. However, Y-TZP is chemically inert and non-reactive, demanding surface modification using alternative approaches to enhance its bond strength to resin-matrix cements. The main aim of this study was to conduct an integrative review on the influence of ultrashort pulse laser patterning of zirconia (3Y-TZP) for enhanced bonding to resin-matrix cements. An electronic search was performed on web of science, SCOPUS, Pubmed/Medline, Google Scholar and EMBASE using a combination of the following search items: zirconia, 3Y-TZP, surface modification, laser surface treatment, AND laser, ultrashortpulse laser, bonding, adhesion, and resin cement. Articles published in the English language, up to January 2022, were included regarding the influence of surface patterning on bond strength of Y-TZP to resin-matrix cements. Out of the 12 studies selected for the present review 10 studies assessed femtosecond lasers while 2 studies assessed picosecond lasers. Ultrashort pulsed laser surface patterning successfully produced different surface morphological aspects without damaging the bulk properties of zirconia. Contrarily, defects such as micro-cracks occurs after surface modification using traditional methods such as grit-blasting or long-pulsed laser patterning. Ultrashort pulsed laser surface patterning increase bond strength of zirconia to resin-matrix cements and therefore such alternative physical method should be considered in dentistry. Also, surface defects were avoided using ultrashort pulsed laser surface patterning, which become the major advantage when compared with traditional physical methods or long pulse laser patterning.


Subject(s)
Dental Bonding , Resin Cements , Surface Properties , Resin Cements/chemistry , Materials Testing , Lasers , Zirconium/chemistry , Yttrium/chemistry , Shear Strength , Dentistry
11.
Turk J Orthod ; 36(2): 126-133, 2023 Jun 22.
Article in English | MEDLINE | ID: mdl-37346374

ABSTRACT

The current systematic review appraises the effectiveness of the types of tooth movements performed with Invisalign® clear aligner on the maxillary incisors. An electronic literature search of published trials was performed through PubMed, LILACS, Scopus, Cochrane Library, and Web of Science databases, and selected journals, from 2009 to 2020. Out of 291 references, five relevant publications were identified for analysis: four studies were performed retrospectively and one prospectively, all non-randomized. Despite the limited set of selected articles, the sample size is significant, with 148 subjects included in the reviewed studies involving the orthodontic treatment of upper incisors. We concluded that movements with the Invisalign® clear aligner on the upper incisors present distinct accuracy, possibly related with movement complexity; intrusion of the incisors has low accuracy (in some cases, 0% of accuracy was reported when the tooth extruded), while incisor extrusion exhibit some of the highest accuracy values reported in the included studies (45%-142%, when the achieved movement was greater than the predicted). Besides, axial (i.e., torque and tip) and horizontal (i.e., translation and rotation) movements are usually effective, with accuracy values between 39%-156% and 42%-79%, respectively. Overall, we determined that the efficiency of aligner to reach the desired movements in the upper incisors was low, as often refinements were required in the included studies. The use of aligner features must be more often considered to improve movement accuracy.

12.
Clin Oral Investig ; 27(7): 3331-3345, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37069409

ABSTRACT

OBJECTIVE: The purpose of this study was to perform an integrative review on laser texturing the inner surface of lithium disilicate-reinforced glass ceramic or zirconia to increase their bond strength to resin-matrix cements. MATERIALS AND METHOD: A bibliographic review was performed on PubMed using the following search terms: "zirconia" OR "lithium disilicate" AND "laser" AND "surface" OR "roughness" AND "bond strength" AND "luting agent" OR "resin cement." Studies published in English language until March 15, 2023, were selected regarding the purpose of this study. RESULTS: A total of fifty-six studies were identified althoug thirteen studies were selected. The findings revealed that zirconia surfaces were significantly modified after laser irradiation resulting in macro-scale aligned retentive regions with depth values ranging from 50 to 120 µm. Average roughness values of laser-textured zirconia by Er,Cr:YSGG laser (~ 0.83 µm) were quite similar when compared to grit-blasted zirconia surfaces (~ 0.9 µm) although roughness increased up to 2.4 µm depending on the laser type and parameters. Lithium disilicate-reinforced glass ceramics textured with Er:YAG revealed an average roughness of around 3.5 µm while surfaces textured using Nd:YAG laser revealed an average roughness of 2.69 µm; that was quite similar to the roughness values recorded for etched surfaces (2.64 µm). The shear bond strength (SBS) values of zirconia surfaces textured on Nd:YVO4 laser irradiation were slightly higher (~ 33.5 MPa) than those recorded for grit-blasted zirconia surfaces (28 MPa). Laser-textured zirconia surfaces on CO2 laser revealed higher SBS values (18.1 ±0.8 MPa) than those (9.1 ± 0.56 MPa) recorded for untreated zirconia surfaces. On lithium disilicate-reinforced glass ceramics, higher SBS values to resin-matrix cements were recorded for specimens textured with a combination of fractional CO2 laser irradiation and HF acid etching (~ 22-24 MPa) when compared with grit-blasted specimens (12.2 MPa). Another study revealed SBS values at around 27.5 MPa for Er:YAG-textured lithium disilicate-reinforced glass ceramics to resin-matrix cements. CONCLUSIONS: The laser irradiation at high power increases the roughness of the inner surface of lithium disilicate-reinforced glass ceramic or zirconia leading to an enhanced bond strength to resin-matrix cements. Thus, the laser type and irradiation parameters can be adjusted to enhance the macro- and micro-scale retention of zirconia and glass ceramic surfaces to resin-matrix cements. CLINICAL RELEVANCE: Alternative methods for surface modification of lithium disilicate-reinforced glass ceramic and zirconia surfaces have been assessed to provide proper morphological aspects for enhanced adhesion to resin-matrix cements. An increase in the bond strength of glass ceramics or zirconia to resin-matrix cements can improve the long-term performance of cemented prosthetic structures in the oral cavity.


Subject(s)
Dental Bonding , Lasers, Solid-State , Resin Cements/chemistry , Lithium , Carbon Dioxide , Surface Properties , Ceramics/chemistry , Dental Porcelain/chemistry , Shear Strength , Materials Testing , Zirconium/chemistry
13.
J Funct Biomater ; 14(3)2023 Mar 07.
Article in English | MEDLINE | ID: mdl-36976072

ABSTRACT

PURPOSE: This study aimed to assess the layer thickness and microstructure of traditional resin-matrix cements and flowable resin-matrix composites at dentin and enamel to composite onlay interfaces after cementation on low loading magnitude. MATERIALS AND METHODS: Twenty teeth were prepared and conditioned with an adhesive system for restoration with resin-matrix composite onlays manufactured by CAD-CAM. On cementation, tooth-to-onlay assemblies were distributed into four groups, including two traditional resin-matrix cements (groups M and B), one flowable resin-matrix composite (group G), and one thermally induced flowable composite (group V). After the cementation procedure, assemblies were cross-sectioned for inspection by optical microscopy at different magnification up to ×1000. RESULTS: The layer thickness of resin-matrix cementation showed the highest mean values at around 405 µm for a traditional resin-matrix cement (group B). The thermally induced flowable resin-matrix composites showed the lowest layer thickness values. The resin-matrix layer thickness revealed statistical differences between traditional resin cement (groups M and B) and flowable resin-matrix composites (groups V and G) (p < 0.05). However, the groups of flowable resin-matrix composites did not reveal statistical differences (p < 0.05). The thickness of the adhesive system layer at around 7 µm and 12 µm was lower at the interfaces with flowable resin-matrix composites when compared to the adhesive layer at resin-matrix cements, which ranged from 12 µm up to 40 µm. CONCLUSIONS: The flowable resin-matrix composites showed adequate flowing even though the loading on cementation was performed at low magnitude. Nevertheless, significant variation in thickness of the cementation layer was noticed for flowable resin-matrix composites and traditional resin-matrix cements that can occur in chair-side procedures due to the clinical sensitivity and differences in rheological properties of the materials.

14.
Materials (Basel) ; 16(4)2023 Feb 13.
Article in English | MEDLINE | ID: mdl-36837188

ABSTRACT

In dentistry, clinicians mainly use dual-cured or light-cured resin-matrix cements to achieve a proper polymerization of the organic matrix leading to enhanced physical properties of the cement. However, several parameters can affect the polymerization of resin-matrix cements. The main aim of the present study was to perform a scoping review on the degree of conversion (DC) of the organic matrix, the polymerization, and the light transmittance of different resin-matrix cements used in dentistry. A search was performed on PubMed using a combination of the following key terms: degree of conversion, resin cements, light transmittance, polymerization, light curing, and thickness. Articles in the English language published up to November 2022 were selected. The selected studies' results demonstrated that restorative structures with a thickness higher than 1.5 mm decrease the light irradiance towards the resin-matrix cement. A decrease in light transmission provides a low energy absorption through the resin cement leading to a low DC percentage. On the other hand, the highest DC percentages, ranging between 55 and 75%, have been reported for dual-cured resin-matrix cements, although the polymerization mode and exposure time also influence the DC of monomers. Thus, the polymerization of resin-matrix cements can be optimized taking into account different parameters of light-curing, such as adequate light distance, irradiance, exposure time, equipment, and wavelength. Then, optimum physical properties are achieved that provide a long-term clinical performance of the cemented restorative materials.

15.
Materials (Basel) ; 15(24)2022 Dec 15.
Article in English | MEDLINE | ID: mdl-36556783

ABSTRACT

AISI 420 martensitic stainless steel is widely used in the mould industry due to its high tensile strength, hardness, and corrosion properties. Another requirement concerning any material used for this type of application is high thermal conductivity to minimise the time between consecutive injection cycles. The surfaces of some parts of the mould may be textured and reinforced with a material with higher thermal conductivity to achieve this aim. The results of a detailed study on the texturing of annealed 420 stainless steel using a Nd:YVO4 fibre laser are presented in this work. The influence of the laser's processing parameters (laser power, scanning speed, number of passes, and line spacing) on the dimensions of the track, microstructure, and hardness of the modified surfaces was studied. Based on the continuity and dimensions of the machined grooves, several promising textures could be produced with laser power values from 5 to 30 W, scanning speeds of 500 to 2000 mm/s, 8 passes or more, and line spacings of 40 and 50 µm. High laser powers were responsible for the dissolution of chromium carbides in the laser tracks, the incorporation of chromium in austenite, and the consequent hardening of the microstructure.

16.
Alzheimers Dement (N Y) ; 8(1): e12249, 2022.
Article in English | MEDLINE | ID: mdl-36447479

ABSTRACT

Introduction: Given the ineffectiveness of the available drug treatment against Alzheimer disease (AD), light-based therapeutic modalities have been increasingly receiving attention with photobiomodulation (PBM) and, more recently, visual stimulation (VS) being among the most promising approaches. However, the PBM and VS light parameters tested so far, as well as their outcomes, vary a lot with conflicting results being reported. Methods: Based on Scopus, PubMed, and Web of Science databases search, this systematic review summarizes, compares, and discusses 43 cell, animal, and human studies of PBM and VS related to cognitive decline and AD pathology. Results: Preclinical work suggests that PBM with 640±30-nm light and VS at 40 Hz attenuates Aß and Tau pathology and improves neuronal and synaptic plasticity with most studies pointing towards enhancement of degradation/clearance mechanisms in the brain of AD animal models. Despite the gap of the translational evidence for both modalities, the few human studies performed so far support the use of PBM at 810-870 nm light pulsing at 40 Hz for improving brain network connectivity and memory in older subjects and AD patients, while 40 Hz VS in humans seems to improve cognition; further clinical investigation is urgently required to clarify the beneficial impact of PBM and VS in AD patients. Discussion: This review highlights PBM and VS as promising light-based therapeutic approaches against AD brain neuropathology and related cognitive decline, clarifying the most effective light parameters for further preclinical and clinical testing and use. Highlights: Light-based brain stimulation produces neural entrainment and reverts neuronal damageBrain PBM and VS attenuate AD neuropathologyPMB and VS are suggested to improve cognitive performance in AD patients and animal modelsLight stimulation represents a promising therapeutic strategy against neurodegeneration.

17.
Porto Biomed J ; 7(4): e176, 2022.
Article in English | MEDLINE | ID: mdl-36186115

ABSTRACT

The purpose of this systematic review is to analyze the methodologies, utilized stimulation parameters, and the main cellular outcomes obtained by in vitro studies that apply a light source on tenocyte cultures. Methods: The PubMed, Scopus, and Web of Science databases were searched up to December 9, 2019 for in vitro studies that used light sources on tenocyte cultures. A 13-item checklist was used to assess methodological quality of the studies and the risk of bias was assessed using the Risk of Bias Assessment tool for Non-randomized Studies tool. Results: Six studies were included. Tenocytes from the Achilles tendon were used by 83.3% of the studies, with 16.7% utilizing the deep digital flexor tendon, with cells in passage 2 to 5. Four studies used lasers and the other 2 used light-emitting diode or intense pulsed light, in wavelengths ranges from 530 to 1100 nm. The application of light to tenocytes resulted in positive effects reported by all studies, including an increase in cell proliferation and migration, and higher protein and gene expression of tendon biomarkers. Studies presented a lack of standardization on reporting light stimulation parameters and experimental methodologies, leading to low methodological quality. There was a high risk of selection, performance, detection, and reporting bias. Conclusions: All studies showed positive effects after light stimulation on tenocytes, regardless of the light source used. However, the lack of standardized data on light stimulation parameters, experimental setup, and the studies' main limitations hindered representative conclusions and comparisons amongst studies' main outcomes.

18.
Biomimetics (Basel) ; 7(2)2022 Apr 20.
Article in English | MEDLINE | ID: mdl-35645176

ABSTRACT

The aim of this study was to evaluate gingival fibroblasts and human osteoblasts' response to textured Nd:YAG laser microgrooves, with different dimensions, on zirconia implant surfaces. A total of 60 zirconia disks (8 mm in diameter and 2 mm in thickness) were produced and divided between four study groups (N = 15): three laser-textured (widths between 125.07 ± 5.29 µm and 45.36 ± 2.37 µm and depth values from 50.54 ± 2.48 µm to 23.01 ± 3.79 µm) and a control group without laser treatment. Human osteoblasts and gingival fibroblasts were cultured on these surfaces for 14 days. FEG-SEM (Field Emission Gun-Scanning Electron Microscope) images showed cellular adhesion at 24 h, with comparable morphology in all samples for both cell types. A similar cell spreading within the grooves and in the space between them was observed. Cell viability increased over time in all study groups; however, no differences were found between them. Additionally, proliferation, ALP (Alkaline phosphatase) activity, collagen type I, osteopontin and interleukin levels were not significantly different between any of the study groups for any of the cell types. Analysis of variance to compare parameters effect did not reveal statistically significant differences when comparing all groups in the different tests performed. The results obtained revealed similar cell behavior based on cell viability and differentiation on different microtopographic laser grooves, compared to a microtopography only established by sandblasting and acid-etching protocol, the reference surface treatment on zirconia dental implants.

19.
Knee ; 37: 28-46, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35660536

ABSTRACT

BACKGROUND: Mechanical-based therapies are not yet recommended to manage osteoarthritis (OA). This systematic review and meta-analysis aim to assess the effects of passive mechanical-based therapies (isolated or combined with other therapies) on patients with knee OA compared to placebo, other isolated or combined interventions. METHODS: Pubmed, Cochrane, Web of Science and EMBASE were searched up to December 2020. We included randomized and non-randomized trials using therapeutic ultrasound, phonophoresis, extracorporeal shockwave therapy (ESWT) and vibration (single or combined with other therapies) compared to placebo, and/or other physical therapies groups. Biochemical, patient-reported, physical and imaging outcome measures were retrieved. We judged risk of bias using the RoB2 tool for randomized studies, the ROBINS-I tool for non-randomized studies, and the GRADE to interpret certainty of results. RESULTS: We included 77 clinical studies. Ultrasound and ESWT statistically improved pain and disability comparing to placebo (combined or not with other therapies), and when added to other therapies versus other therapies alone. Ultrasound was statistically inferior to phonophoresis (combined or not with other therapies) in reducing pain and disability for specific therapeutic gels and/or combined therapies. Vibration plus exercise statistically improved pain relief and function versus exercise alone. All meta-analyses showed very-low certainty of evidence, with 15 of 42 (38%) pooled comparisons being statistically significant (weak to large effect). CONCLUSIONS: Despite the inconsistent evidence with very-low certainty, the potential benefits of passive mechanical-based therapies should not be disregard and cautiously recommended that clinicians might use them in some patients with knee OA.


Subject(s)
Osteoarthritis, Knee , Ultrasonic Therapy , Humans , Osteoarthritis, Knee/drug therapy , Osteoarthritis, Knee/therapy , Pain , Pain Management
20.
Clin Oral Investig ; 26(9): 5575-5594, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35767045

ABSTRACT

PURPOSE: The objective of this study was to perform an integrative review on the effect the inorganic fillers on the light transmission through the resin-matrix composites during the light-curing procedure. METHOD: A bibliographic review was performed on PubMed using the following search terms: "fillers" OR "particle" AND "light curing" OR "polymerization" AND "light transmission" OR "light absorption" OR "light irradiance" OR "light attenuation" OR "light diffusion" AND "resin composite." The search involved articles published in English language in the last 10 years. RESULTS: Selected studies reported a decrease in biaxial strength and hardness in traditional resin-matrix composites in function of the depth of polymerization. However, there were no significant differences in biaxial strength and hardness recorded along the polymerization depth of Bulk-Fill™ composites. Strength and hardness were enhanced by increasing the size and content of inorganic fillers although some studies revealed a progressive decrease in the degree of conversion on increasing silica particle size. The translucency of glass-ceramic spherical fillers promoted light diffusion mainly in critical situations such as in the case of deep proximal regions of resin-matrix composites. CONCLUSIONS: The amount of light transmitted through the resin-matrix composites is influenced by the size, content, microstructure, and shape of the inorganic filler particles. The decrease of the degree of conversion affects negatively the physical and mechanical properties of the resin-matrix composites. CLINICAL RELEVANCE: The type and content of inorganic fillers in the chemical composition of resin-matrix composites do affect their polymerization. As a consequence, the clinical performance of resin-matrix composites can be compromised leading to variable physical properties and degradation. The polymerization mode of resin-matrix composites can be improved according to the type of inorganic fillers in their chemical composition.


Subject(s)
Curing Lights, Dental , Light-Curing of Dental Adhesives , Composite Resins/chemistry , Materials Testing , Polymerization , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...