Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Opt ; 62(29): 7669-7677, 2023 Oct 10.
Article in English | MEDLINE | ID: mdl-37855474

ABSTRACT

The single-beam Z-scan thermal lens technique is conducted to evaluate the fluorescence quantum yield of various solutions in the case of high-moderate absorption, considering both scenarios: solutions with substantial fluorescence and solutions with high thermal efficiency but low fluorescence. An analytical calculation is performed to determine the uncertainties associated with the random errors introduced by optical detectors. The results reveal that solutions with low fluorescence lead to a significant error, whereas higher fluorescence can help in decreasing the uncertainty. Additionally, the issue of random errors arising when multiple measurements are needed to accurately estimate the fluorescence of a solution will be discussed in different situations.

2.
Materials (Basel) ; 15(14)2022 Jul 19.
Article in English | MEDLINE | ID: mdl-35888474

ABSTRACT

The thermal lens effect is analyzed as a time-resolved Z-scan measurement using cw-single Gaussian beam configuration. The main characteristics of the measurement method are determined. We focus on the evaluation of the measurement error from statistical calculations to also check the linearity of the response and the way to extract the thermo-optical characteristics of absorbing liquids. The results are also applied to demonstrate the feasibility of absorption and scattering efficiencies determination on gold nanoparticles of 5 and 50 nm diameters.

3.
Materials (Basel) ; 13(11)2020 Jun 04.
Article in English | MEDLINE | ID: mdl-32512766

ABSTRACT

Zinc oxide nanoparticles were prepared from Zn5(CO3)2(OH)6 precursor, capped with poly(vinylpyrrolidone) (PVP), and annealed at 600 °C. The obtained powders were characterized by a powder X-ray diffraction (PXD), transmission electron microscopy (TEM), scanning electron microscopy (SEM), UV-visible spectroscopy (UV-vis), Raman spectroscopy, infrared spectroscopy (IR), thermal analysis (TGA/DTA), and third-order nonlinear (NL) optical measurement. Morphological evaluation by TEM and SEM measurements indicated that the precursor micro-particles are ball-shaped structures composed of plates with a thickness of approximately 10 nm. ZnO thin films, as well as ZnO/polymer multilayer layouts, were obtained by wet chemical methods (spin- and dip-coating). Surface topography and morphology of the obtained films were studied by SEM and AFM microscopy. Films with uniformly distributed ZnO plates, due to the erosion of primary micro-particles were formed. The fabricated specimens were also analyzed using a spectroscopic ellipsometry in order to calculate dielectric function and film thickness.

4.
Opt Lett ; 43(20): 5037, 2018 10 15.
Article in English | MEDLINE | ID: mdl-30320812

ABSTRACT

This erratum corrects an error in Fig. 4 of Opt. Lett. 39, 5046 (2014).

5.
Opt Lett ; 39(17): 5046-9, 2014 Sep 01.
Article in English | MEDLINE | ID: mdl-25166070

ABSTRACT

The nonlinear response of liquid water was investigated at 1064 and 532 nm using a Nd:YAG laser delivering pulses of 17 ps and its second harmonic. The experiments were performed using the D4σ method combined with the Z-scan technique. Nonlinear refractive indices of third- and fifth-order were determined, as well as the three-photon absorption coefficient, for both wavelengths. A good agreement was found between theory and experiment.

6.
Opt Lett ; 38(13): 2206-8, 2013 Jul 01.
Article in English | MEDLINE | ID: mdl-23811878

ABSTRACT

We show that direct measurement of the beam radius in Z-scan experiments using a CCD camera at the output of a 4f-imaging system allows higher sensitivity and better accuracy than Baryscan. One of the advantages is to be insensitive to pointing instability of pulsed lasers because no hard (physical) aperture is employed as in the usual Z-scan. In addition, the numerical calculations involved here and the measurement of the beam radius are simplified since we do not measure the transmittance through an aperture and it is not subject to mathematical artifacts related to a normalization process, especially when the diffracted light intensity is very low.

SELECTION OF CITATIONS
SEARCH DETAIL
...