Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 115
Filter
1.
Clin Oncol (R Coll Radiol) ; 30(12): 780-792, 2018 12.
Article in English | MEDLINE | ID: mdl-30318343

ABSTRACT

AIMS: Our purpose was to assess the diagnostic accuracy and prognostic value of diffusion-weighted imaging (DWI) and 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (18F-FDG-PET/CT) carried out 3-6 months after (chemo)radiotherapy in head and neck squamous cell carcinoma. MATERIALS AND METHODS: For this retrospective cohort study we included 82 patients with advanced-stage head and neck squamous cell carcinoma treated between 2012 and 2015. Primary tumours and lymph nodes were assessed separately. DWI was analysed qualitatively and quantitatively. 18F-FDG-PET/CT was evaluated using the Hopkins criteria. Dichotomous qualitative analysis was carried out for both modalities. Cox regression analysis was used for univariate analysis of recurrence-free survival (RFS). Significant univariate parameters were included in multivariate analysis. RESULTS: In 12 patients, locoregional recurrence occurred. With all imaging strategies, either single-modality or multi-modality, a high negative predictive value (NPV) was achieved (94.3-100%). In response evaluation of the primary site, the preferred strategy is 18F-FDG-PET/CT only, which resulted in a sensitivity of 85.7%, specificity of 86.5%, positive predictive value (PPV) of 37.5% and NPV of 98.5%. For response evaluation of the neck, the best results were obtained with a sequential approach only including the second modality in positive reads of the first modality. It did not matter which modality was assessed first. This strategy for lymph node assessment resulted in a sensitivity, specificity, PPV and NPV of 83.3%, 95.6%, 62.5%, and 98.5%, respectively. After correction for received treatment and human papillomavirus status, primary tumour (P = 0.009) or lymph node (P < 0.001) Hopkins score ≥4 on 18F-FDG-PET/CT remained significant predictors of RFS. CONCLUSION: For response evaluation of the primary tumour 18F-FDG-PET/CT only is the preferred strategy, whereas for the neck a sequential approach including both DWI and 18F-FDG-PET/CT resulted in the best diagnostic accuracy for follow-up after (chemo)radiotherapy. Qualitative analysis of 18F-FDG-PET/CT is a stronger predictor of RFS than DWI analysis.


Subject(s)
Chemoradiotherapy/methods , Diffusion Magnetic Resonance Imaging/methods , Fluorodeoxyglucose F18 , Head and Neck Neoplasms/pathology , Neoplasm Recurrence, Local/pathology , Positron Emission Tomography Computed Tomography/methods , Squamous Cell Carcinoma of Head and Neck/pathology , Adult , Aged , Aged, 80 and over , Female , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/therapy , Humans , Male , Middle Aged , Neoplasm Recurrence, Local/diagnostic imaging , Neoplasm Recurrence, Local/therapy , Prognosis , Radiopharmaceuticals , Retrospective Studies , Squamous Cell Carcinoma of Head and Neck/diagnostic imaging , Squamous Cell Carcinoma of Head and Neck/therapy
2.
Clin Otolaryngol ; 43(3): 875-881, 2018 06.
Article in English | MEDLINE | ID: mdl-29377508

ABSTRACT

OBJECTIVES: The detection of distant metastases is of major importance in management of head and neck squamous cell carcinoma patients. DESIGN: All patients underwent 18 FDG PET/CT for the detection of distant metastases. SETTING: Retrospective single-centre study. PARTICIPANTS: Head and neck squamous cell carcinoma patients with high-risk factors for distant metastases. MAIN OUTCOME MEASURES: Accuracy of 18 FDG PET/CT for the detection of distant metastases using clinical development of distant metastases and a minimal follow-up of twelve months as reference standard. Comparison of overall survival between patients diagnosed with distant metastases during initial screening and patients diagnosed with distant metastases during follow-up. RESULTS: In 23 (12%) of the 190 patients, 18 FDG PET/CT detected distant metastases at screening. Sensitivity and negative predictive value were 46.2% (95% CI 32.6-59.7) and 82.6% (95% CI 76.8-88.5). No difference in median overall survival from the time of distant metastases detection was found between patients diagnosed with DM during work-up or during follow-up. CONCLUSIONS: In head and neck squamous cell carcinoma patients with high-risk factors, 18 FDG PET/CT has a high negative predictive value for the detection of distant metastases and should be used in daily clinical practice, although the sensitivity is limited when long-term follow-up is used as reference standard.


Subject(s)
Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Radiopharmaceuticals , Squamous Cell Carcinoma of Head and Neck/diagnostic imaging , Squamous Cell Carcinoma of Head and Neck/secondary , Adult , Aged , Aged, 80 and over , Early Detection of Cancer , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Squamous Cell Carcinoma of Head and Neck/mortality , Survival Rate
3.
AJNR Am J Neuroradiol ; 36(11): 2153-8, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26294647

ABSTRACT

BACKGROUND AND PURPOSE: Criteria for ultrasound-guided fine-needle aspiration cytology (USgFNAC) for the detection of occult lymph node metastasis in patients with clinically negative head and neck cancer are based on the morphology of cervical lymph nodes. To improve the selection of lymph nodes for USgFNAC, we examined the feasibility of fused freehand single-photon emission tomography ultrasound-guided fine-needle cytology (freehand SPECT-USgFNAC) of sentinel nodes in patients with early stage oral and head and neck skin cancer. MATERIALS AND METHODS: Six patients with early-stage head and neck cancer (4 oral and 2 head and neck skin cancers) and a clinically negative neck who were scheduled for transoral or local excision and a sentinel node procedure underwent USgFNAC and freehand SPECT-USgFNAC preoperatively. RESULTS: All freehand SPECT sonographic examinations were technically successful in terms of identifying sentinel nodes. All aspirates of sentinel nodes obtained by freehand SPECT-USgFNAC contained substantial radioactivity, confirming puncture of the sentinel nodes. USgFNAC evaluated 13 lymph nodes; freehand SPECT-USgFNAC, 19 nodes; and sentinel node biopsy, 13 nodes. Three sentinel nodes were histopathologically positive and were selected for aspiration cytology by freehand SPECT-USgFNAC, but not by conventional ultrasound. The cytologic examination findings of the aspirations were negative or inconclusive. CONCLUSIONS: Freehand SPECT ultrasound can identify sentinel nodes and could potentially improve USgFNAC in patients with head and neck cancer by better selection of lymph nodes at highest risk of having metastases (sentinel nodes), but its sensitivity is limited by sampling error and insufficient aspirated material for cytology.


Subject(s)
Carcinoma, Squamous Cell/pathology , Head and Neck Neoplasms/pathology , Lymphatic Metastasis/diagnostic imaging , Tomography, Emission-Computed, Single-Photon/methods , Ultrasonography, Interventional/methods , Adult , Aged , Aged, 80 and over , Biopsy, Fine-Needle/methods , Carcinoma, Squamous Cell/diagnostic imaging , Female , Head and Neck Neoplasms/diagnostic imaging , Humans , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Lymphatic Metastasis/pathology , Male , Middle Aged , Multimodal Imaging , Sensitivity and Specificity , Sentinel Lymph Node Biopsy , Squamous Cell Carcinoma of Head and Neck
4.
Int J Oral Maxillofac Surg ; 44(5): 627-31, 2015 May.
Article in English | MEDLINE | ID: mdl-25636702

ABSTRACT

Changes in cross-sectional area (CSA), volume (indicating muscle strength), and direction of the masseter and medial pterygoid muscles after surgical mandibular advancement were measured, along with the rotation of the condyles after bilateral sagittal split osteotomies (BSSOs) to advance the mandible. Measurements were done on magnetic resonance images obtained before and 2 years after surgery. CSA and volume were measured in five short-face and seven long-face patients (five males, seven females). Muscle direction was calculated in eight short-face and eight long-face patients (eight males, eight females). Short-face patients underwent BSSO only; long-face patients underwent combined BSSO and Le Fort I osteotomies. The CSA and volume decreased significantly (mean 18%) in all patients after surgery. The postoperative muscle direction was significantly more vertical (9°) in long-face patients. Rotations of the proximal segments (condyles) were minimal after 2 years. The results of this study showed that, after BSSO advancement surgery, changes in the masseter and medial pterygoid muscles are not likely to cause increased pressure on the condyles and nor are the minimal rotations of the condyles. It is concluded that neither increased muscle traction nor condylar rotations can be held responsible for progressive condylar resorption after advancement BSSO.


Subject(s)
Bone Resorption/pathology , Mandibular Condyle/pathology , Mandibular Condyle/surgery , Masseter Muscle/pathology , Masseter Muscle/surgery , Osteotomy, Sagittal Split Ramus , Pterygoid Muscles/pathology , Pterygoid Muscles/surgery , Adolescent , Adult , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Muscle Strength , Osteotomy, Le Fort , Treatment Outcome
5.
AJNR Am J Neuroradiol ; 36(4): 763-7, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25721078

ABSTRACT

BACKGROUND AND PURPOSE: Patients with human papillomavirus-positive oropharyngeal squamous cell carcinomas have a better survival rate than those with human papillomavirus-negative oropharyngeal squamous cell carcinomas. DWI characterizes biologically relevant tumor features, and the generated ADC may also provide prognostic information. We explored whether human papillomavirus status and ADC values are independent tumor characteristics. MATERIALS AND METHODS: Forty-four patients with oropharyngeal squamous cell carcinomas underwent pretreatment DWI. ADC values for the primary tumors were determined by using 3 b-values in an ROI containing the largest area of solid tumor on a single section of an axial DWI image. Human papillomavirus status was determined with p16 immunostaining, followed by high-risk human papillomavirus DNA detection on the p16-positive cases. RESULTS: Twenty-two patients were human papillomavirus-positive (50.0%). ADC values were not significantly different between human papillomavirus-negative (ADC(mean) = 1.56 [1.18-2.18] × 10(3) mm(2)/s) and human papillomavirus-positive tumors (ADC(mean) = 1.46 [1.07-2.16] × 10(3) mm(2)/s). CONCLUSIONS: No significant association between ADC and human papillomavirus status was found in oropharyngeal squamous cell carcinomas. In our study population, differences in genetic and histologic features between human papillomavirus-positive and human papillomavirus-negative oropharyngeal squamous cell carcinomas did not translate into different ADC values. Long-term follow-up studies are needed to establish whether ADC has prognostic value and whether this is independent of the human papillomavirus status.


Subject(s)
Carcinoma, Squamous Cell/pathology , Carcinoma, Squamous Cell/virology , Diffusion Magnetic Resonance Imaging/methods , Oropharyngeal Neoplasms/pathology , Oropharyngeal Neoplasms/virology , Adult , Aged , Carcinoma, Squamous Cell/mortality , Female , Humans , Male , Middle Aged , Oropharyngeal Neoplasms/mortality , Papillomavirus Infections/complications , Papillomavirus Infections/mortality , Papillomavirus Infections/pathology , Prognosis , Survival Rate
6.
Oral Oncol ; 51(3): 267-71, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25552384

ABSTRACT

BACKGROUND AND PURPOSE: Previously identified high risk factors for development of distant metastases are: three or more lymph node metastases, bilateral lymph node metastases, lymph nodes larger than 6cm, low jugular lymph node metastases, locoregional tumor recurrence and second primary tumors. The aims of this study were to validate these specific risk factors and to investigate the impact of time (i.e. during screening or follow-up) of detection of distant metastases on survival. MATERIAL AND METHODS: From a total of 301 HNSCC patients with high risk factors who were scheduled for extensive treatment and underwent pretreatment screening on distant metastases using chest CT and/or whole body PET(-CT) (in some patients combined with whole body MRI), the high risk factors, the development and time point of distant metastases and survival were analyzed. RESULTS: Forty-four percent developed distant metastases. Multivariate analysis revealed that bilateral lymph node metastases is the strongest predictive factor. Locoregional recurrence and second primary tumor were the risk factors associated with the lowest cumulative incidence. However, if the risk factor locoregional recurrence was split into local and regional recurrences, regional recurrence became a high risk factor. The more high risk factors a patient had the lower the 5-year distant metastases free survival was. Patients with distant metastases detected pretreatment has a significant worse survival (corrected for lead time bias) compared to patients with distant metastases diagnosed during follow-up. CONCLUSIONS: The validity of three or more lymph node metastases, bilateral lymph node metastases, lymph nodes larger than 6cm, low jugular lymph node metastases and regional recurrence as high risk factors for the development of distant metastases was confirmed. If more high risk factors are present the cumulative incidence of distant metastases increases significantly. The detection of distant metastases by pretreatment screening worsens the overall survival as compared to distant metastases detected during follow-up.


Subject(s)
Carcinoma, Squamous Cell/epidemiology , Head and Neck Neoplasms/epidemiology , Lymphatic Metastasis , Neoplasm Recurrence, Local/epidemiology , Neoplasms, Second Primary/epidemiology , Adult , Aged , Aged, 80 and over , Carcinoma, Squamous Cell/therapy , Disease-Free Survival , Female , Fluorodeoxyglucose F18 , Follow-Up Studies , Head and Neck Neoplasms/therapy , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Positron-Emission Tomography/methods , Prognosis , Radiopharmaceuticals , Retrospective Studies , Risk Factors , Time Factors , Tomography, X-Ray Computed/methods
7.
AJNR Am J Neuroradiol ; 36(2): 384-90, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25258365

ABSTRACT

BACKGROUND AND PURPOSE: DWI is typically performed with EPI sequences in single-center studies. The purpose of this study was to determine the reproducibility of ADC values in the head and neck region in healthy subjects. In addition, the reproducibility of ADC values in different tissues was assessed to identify the most suitable reference tissue. MATERIALS AND METHODS: We prospectively studied 7 healthy subjects, with EPI and TSE sequences, on 5 MR imaging systems at 3 time points in 2 institutions. ADC maps of EPI (with 2 b-values and 6 b-values) and TSE sequences were compared. Mean ADC values for different tissues (submandibular gland, sternocleidomastoid muscle, spinal cord, subdigastric lymph node, and tonsil) were used to evaluate intra- and intersubject, intersystem, and intersequence variability by using a linear mixed model. RESULTS: On 97% of images, a region of interest could be placed on the spinal cord, compared with 87% in the tonsil. ADC values derived from EPI-DWI with 2 b-values and calculated EPI-DWI with 2 b-values extracted from EPI-DWI with 6 b-values did not differ significantly. The standard error of ADC measurement was the smallest for the tonsil and spinal cord (standard error of measurement = 151.2 × 10(-6) mm/s(2) and 190.1 × 10(-6) mm/s(2), respectively). The intersystem difference for mean ADC values and the influence of the MR imaging system on ADC values among the subjects were statistically significant (P < .001). The mean difference among examinations was negligible (ie, <10 × 10(-6) mm/s(2)). CONCLUSIONS: In this study, the spinal cord was the most appropriate reference tissue and EPI-DWI with 6 b-values was the most reproducible sequence. ADC values were more precise if subjects were measured on the same MR imaging system and with the same sequence. ADC values differed significantly between MR imaging systems and sequences.


Subject(s)
Diffusion Magnetic Resonance Imaging , Echo-Planar Imaging , Adult , Diffusion Magnetic Resonance Imaging/instrumentation , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/instrumentation , Echo-Planar Imaging/methods , Female , Head , Healthy Volunteers , Humans , Lymph Nodes , Male , Middle Aged , Neck , Reproducibility of Results , Spinal Cord
8.
AJNR Am J Neuroradiol ; 36(2): 355-60, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25523593

ABSTRACT

BACKGROUND AND PURPOSE: Intratumoral calcifications are very important in the diagnosis of retinoblastoma. Although CT is considered superior in detecting calcification, its ionizing radiation, especially in patients with hereditary retinoblastoma, should be avoided. The purpose of our study was to validate T2*WI for the detection of calcification in retinoblastoma with ex vivo CT as the criterion standard. MATERIALS AND METHODS: Twenty-two consecutive patients with retinoblastoma (mean age, 21 months; range, 1-71 months) with enucleation as primary treatment were imaged at 1.5T by using a dedicated surface coil. Signal-intensity voids indicating calcification on T2*WI were compared with ex vivo high-resolution CT, and correlation was scored by 2 independent observers as poor, good, or excellent. Other parameters included the shape and location of the signal-intensity voids. In 5 tumors, susceptibility-weighted images were evaluated. RESULTS: All calcifications visible on high-resolution CT could be matched with signal-intensity voids on T2*WI, and correlation was scored as excellent in 17 (77%) and good in 5 (23%) eyes. In total, 93% (25/27) of the signal-intensity voids inside the tumor correlated with calcifications compared with none (0/8) of the signal-intensity voids outside the tumor. Areas of nodular signal-intensity voids correlated with calcifications in 92% (24/26), and linear signal-intensity voids correlated with hemorrhage in 67% (6/9) of cases. The correlation of signal-intensity voids on SWI was better in 4 of 5 tumors compared with T2*WI. CONCLUSIONS: Signal-intensity voids on in vivo T2*WI correlate well with calcifications on ex vivo high-resolution CT in retinoblastoma. Gradient-echo sequences may be helpful in the differential diagnosis of retinoblastoma. The combination of funduscopy, sonography, and high-resolution MR imaging with gradient-echo sequences should become the standard diagnostic approach for retinoblastoma.


Subject(s)
Calcinosis/pathology , Magnetic Resonance Imaging/methods , Retinal Neoplasms/pathology , Retinoblastoma/pathology , Tomography, X-Ray Computed , Calcinosis/diagnostic imaging , Child , Child, Preschool , Diagnosis, Differential , Female , Humans , Image Processing, Computer-Assisted , Infant , Male , Retinal Neoplasms/diagnostic imaging , Retinoblastoma/diagnostic imaging
9.
AJNR Am J Neuroradiol ; 34(4): 791-6, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23042930

ABSTRACT

BACKGROUND AND PURPOSE: 7T MR imaging has led to improved detection and classification of cortical MS lesions, mainly based on T2*-weighted gradient-echo sequences. Depiction of cortical GM by using the recommended MS imaging protocol has not yet been investigated at 7T. We aimed to investigate prospectively which recommended sequence for clinical use has the highest value at 7T, in terms of GM and WM lesion detection. MATERIALS AND METHODS: Thirty-seven patients with MS (mean age, 43.8 years; 25 women) and 7 healthy controls (mean age, 40.4 years; 5 women) underwent multicontrast 7T MR imaging including the recommended clinical 2D-T2WI, 3D-T1WI, 3D-FLAIR, and GM-specific 3D-DIR. Lesions were scored and categorized anatomically by 3 raters, in consensus. The value of sequences was evaluated lesion-wise and patient-wise (Wilcoxon signed-rank test). RESULTS: At 7T, 3D-FLAIR detected the highest number of total cortical GM lesions (217), 89% more than 3D-DIR and 87% and 224% more than 2D-T2WI and 3D-T1WI. Patient-wise analysis showed that this difference between 3D-FLAIR and 3D-DIR was statistically significant (P<.04), and most pronounced for the number of mixed lesions (P<.03). 3D-FLAIR also detected the highest number of total WM lesions (2605), but the difference with 3D-DIR and 3D-T1WI was not significant. CONCLUSIONS: When using recommended clinical sequences at 7T, the best way to detect cortical GM lesions is with 3D-FLAIR and not by GM-specific 3D-DIR or by conventional 2D-T2WI and 3D-T1WI sequences.


Subject(s)
Cerebral Cortex/pathology , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Multiple Sclerosis/pathology , Adolescent , Adult , Female , Humans , Male , Middle Aged , Prospective Studies , Severity of Illness Index , Young Adult
10.
AJNR Am J Neuroradiol ; 33(11): 2129-35, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22627800

ABSTRACT

BACKGROUND AND PURPOSE: Noninvasive evaluation of retinoblastoma treatment response has become more important due to increased use of eye-sparing treatments. We evaluated the relation between DCE-MR imaging and histopathologic parameters to determine the value of DCE-MR imaging in assessing tumor angiogenesis and prognostic features. MATERIALS AND METHODS: Fifteen consecutive patients with retinoblastoma (mean age, 24 months; range, 2-70 months) undergoing enucleation as the primary treatment (15 eyes) were scanned at 1.5T by using dedicated surface coils. Pretreatment DCE-MR imaging of the most affected eye was evaluated by 2 observers by using curve-pattern analysis, with the first 5 minutes of each curve and the full time-series described as κ(5min) and κ(17min), respectively. Assessed histopathologic and immunologic parameters included optic nerve invasion, choroid invasion, MVD, tumor necrosis, and expression of VEGF and Flt-1. RESULTS: The median value of κ(5min) was 1.28 (range, 0.87-2.07) and correlated positively with MVD (P = .008). The median value of κ(17min) was 1.33 (range, 0.35-3.08) and correlated negatively with tumor necrosis (P = .002). Other histopathologic and immunohistopathologic parameters did not correlate with DCE-MR imaging parameters. Interobserver agreement was 0.53 for κ(5min) and 0.91 for κ(17min). CONCLUSIONS: In retinoblastoma, the early phase of the DCE time curve positively correlates with MVD, while the presence of late enhancement is correlated with necrosis. Thus, the potential for DCE-MR imaging to noninvasively assess tumor angiogenesis and necrosis in retinoblastoma is promising and warrants further investigation.


Subject(s)
Magnetic Resonance Imaging/methods , Neovascularization, Pathologic/complications , Neovascularization, Pathologic/pathology , Retinal Neoplasms/complications , Retinal Neoplasms/pathology , Retinoblastoma/complications , Retinoblastoma/pathology , Child , Child, Preschool , Contrast Media , Female , Humans , Infant , Male , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic
11.
Int J Oral Maxillofac Surg ; 41(9): 1131-6, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22525894

ABSTRACT

This study analysed the effects of change of direction of masseter (MAS) and medial pterygoid muscles (MPM) and changes of moment arms of MAS, MPM and bite force on static and dynamic loading of the condyles after surgical mandibular advancement. Rotations of the condyles were assessed on axial MRIs. 16 adult patients with mandibular hypoplasia were studied. The mandibular plane angle (MPA) was <39° in Group I (n=8) and >39° in Group II (n=8). All mandibles were advanced with a bilateral sagittal split osteotomy (BSSO). In Group II, BSSO was combined with Le Fort I osteotomy. Pre and postoperative moment arms of MAS, MPM and bite force were used in a two-dimensional model to assess static loading of the condyles. Pre and postoperative data on muscle cross-sectional area, volume and direction were introduced in three-dimensional dynamic models of the masticatory system to assess the loading of the condyles during opening and closing. Postsurgically, small increases of static condylar loading were calculated. Dynamic loading decreased slightly. Minor rotations of the condyles were observed. The results do not support the idea that increased postoperative condylar loading is a serious cause for condylar resorption or relapse.


Subject(s)
Bite Force , Mandibular Advancement/methods , Mandibular Condyle/physiology , Osteotomy, Sagittal Split Ramus/methods , Temporomandibular Joint/physiology , Adolescent , Adult , Biomechanical Phenomena , Dental Stress Analysis , Female , Humans , Male , Masseter Muscle/physiology , Mastication/physiology , Middle Aged , Models, Anatomic , Osteotomy, Le Fort/methods , Pterygoid Muscles/physiology , Range of Motion, Articular , Young Adult
12.
Int J Oral Maxillofac Surg ; 41(8): 922-9, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22418077

ABSTRACT

This study evaluated whether surgical mandibular advancement procedures induced a change in the direction and the moment arms of the masseter (MAS) and medial pterygoid (MPM) muscles. Sixteen adults participated in this study. The sample was divided in two groups: Group I (n=8) with a mandibular plane angle (mpa) <39° and Group II (n=8) with an mpa >39°. Group I patients were treated with a bilateral sagittal split osteotomy (BSSO). Those in Group II were treated with a BSSO combined with a Le Fort I osteotomy. Pre- and postoperative direction and moment arms of MAS and MPM were compared in these groups. Postsurgically, MAS and MPM in Group II showed a significantly more vertical direction in the sagittal plane. Changes of direction in the frontal plane and changes of moment arms were insignificant in both groups. This study demonstrated that bimaxillary surgery in patients with an mpa >39° leads to a significant change of direction of MAS and MPM in the sagittal plane.


Subject(s)
Magnetic Resonance Imaging/methods , Mandibular Advancement/methods , Masseter Muscle/pathology , Pterygoid Muscles/pathology , Adolescent , Adult , Cephalometry/methods , Chin/surgery , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Mandible/pathology , Mandible/surgery , Mandibular Condyle/pathology , Middle Aged , Orthognathic Surgical Procedures/methods , Osteotomy, Le Fort/methods , Osteotomy, Sagittal Split Ramus/methods , Rotation , Vertical Dimension , Young Adult
13.
AJNR Am J Neuroradiol ; 33(7): 1239-46, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22322615

ABSTRACT

BACKGROUND AND PURPOSE: Several studies have reported on the clinical utility of DWI in head and neck cancer, but none of these studies compared HASTE with EPI-DWI in patients with head and neck cancer. The aim of our study was to compare detection and delineation of primary tumors and lymph nodes by using HASTE and EPI-DWI techniques in patients with HNSCC. MATERIALS AND METHODS: Twelve patients with HNSCC and a total of 12 primary tumors and 77 visualized lymph nodes on MR imaging underwent DWI by using both EPI-based and HASTE techniques. Interobserver agreement for detection, delineation, and ADC values of primary tumors and lymph nodes was assessed by 2 radiologists, and artifacts for both DWI techniques were described. RESULTS: The number of lesions (primary tumors and lymph nodes) identified on pretreatment EPI-DWI was higher compared with pretreatment HASTE-DWI, with means of total lesions of 88.5 and 69.0, respectively. Delineation of lesions was also better on pretreatment EPI-DWI compared with pretreatment HASTE-DWI, with means of well-delineated lesions of 80.5 and 27.5, respectively. Both EPI- and HASTE-DWI showed good interobserver agreement between radiologists of ADC values in lesions with ICC values of 0.79 and 0.92, respectively. Intraobserver agreement for ADC values in lesions assessed with EPI- versus HASTE-DWI techniques was low, with ICC values of 0.31 and 0.42, respectively. Significant interobserver disagreement concerning detection was only seen with HASTE-DWI, and none of the DWI techniques showed significant interobserver disagreements regarding delineation. EPI-DWI was more prone to susceptibility artifacts than HASTE-DWI: Ninety-one percent of primary tumors and 16% of lymph nodes were affected by susceptibility artifacts on pretreatment EPI-DWI, whereas these artifacts were not seen on HASTE-DWI. CONCLUSIONS: Primary tumors and lymph nodes are more easily visualized on EPI-DWI compared with HASTE-DWI. EPI-DWI has geometric distortion, however, which has a negative effect on interobserver agreement of ADC values.


Subject(s)
Carcinoma/pathology , Carcinoma/secondary , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Head and Neck Neoplasms/pathology , Aged , Fourier Analysis , Humans , Image Enhancement/methods , Lymphatic Metastasis , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
14.
AJNR Am J Neuroradiol ; 33(1): 110-8, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22033715

ABSTRACT

BACKGROUND AND PURPOSE: Retinoblastoma may exhibit variable hyperintensities on DWI, resulting in different values in the ADC maps, depending on their histology and cellularity. However, EP-based DWI has susceptibility artifacts and image distortions, which make DWI of the orbit a challenging technique. The aim of this study was to investigate the feasibility of single-shot turbo spin-echo (HASTE) DWI in the evaluation of children with retinoblastoma and to assess the value of ADC maps in differentiating viable and necrotic tumor tissue. MATERIALS AND METHODS: Two radiologists assessed conventional MR images, DWI, and ADC maps of 17 patients with retinoblastoma (n = 17 eyes). Non-EP DWI was performed by using a HASTE sequence with b-values of 0 and 1000 s/mm(2). ADC values were measured for enhancing and nonenhancing tumor tissue. ADC maps were compared with histopathologic findings regarding tumor differentiation and viability. RESULTS: On DWI, vital tumor tissue showed hyperintensity with negligible intensity of surrounding vitreous. The difference in mean (range) ADC values between enhancing (1.03 [0.72-1.22] × 10(-3) mm(2) s(-1)) and nonenhancing (1.47 [0.99-1.80] × 10(-3) mm(2) s(-1)) parts of retinoblastoma was statistically significant (P < .0005). Nonenhancing tumor parts showed a significantly lower ADC compared with vitreous (2.67 [2.24-3.20]×10(-3) mm(2) s(-1)) (P < .0005) and subretinal fluid (2.20 [1.76-2.96] × 10(-3) mm(2) s(-1)) (P < .0005). Histopathologically, low ADC values (enhancing tumor part) correlated to viable tumor tissue, whereas intermediate ADC values (nonenhancing tumor parts) correlated to necrotic tumor tissue. CONCLUSIONS: HASTE DWI allowed adequate characterization of retinoblastoma, and ADC is a helpful tool to differentiate viable and necrotic tumor tissue and might be valuable in monitoring the response to eye-preserving therapies.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Retinal Neoplasms/pathology , Retinoblastoma/pathology , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Pilot Projects , Reproducibility of Results , Sensitivity and Specificity , Spin Labels
15.
Pituitary ; 15 Suppl 1: S46-8, 2012 Dec.
Article in English | MEDLINE | ID: mdl-21660520

ABSTRACT

In this case report we describe a 38 year-old-female with galactorrhea several months after the birth of an anencephalic child. She had hyperpolactemia and imaging of the pituitary gland revealed a midline defect and a nasopharyngeal mass compatible with a meningo-(hypophyso-) encephalocele and possibly an ectopic teratoma or desmoid. She was treated with dopamine agonists for 10 years and after cessation of therapy her prolactin levels remain normal. The nasopharyngeal mass remained unchanged over time and there were no signs of hypopituitarism. The hyperprolactinemia at presentation was probably caused by earlier pregnancy and stalk dysfunction due to traction by the mass. With decline of pituitary size, after starting dopamine agonists, the traction probably reduced resulting in a normal prolactin level. Our patient was warned against manipulation in de nose, because this could damage the meningo-encephalocele. An MRI will be preformed every 2 years to monitor changes in de mass.


Subject(s)
Hyperprolactinemia/diagnosis , Nose/pathology , Adult , Dopamine Agonists/therapeutic use , Female , Humans , Hyperprolactinemia/drug therapy , Pituitary Gland/pathology
17.
Horm Res Paediatr ; 75(6): 403-11, 2011.
Article in English | MEDLINE | ID: mdl-21273761

ABSTRACT

BACKGROUND: In adults with Prader-Willi syndrome (PWS), limited information is available about pituitary function, more specifically the prevalence of growth hormone deficiency (GHD). The aim of this study was to gain more insight into endocrine function in PWS adults, with emphasis on GH secretion. METHODS: 15 randomly selected adult PWS individuals were included and 14 healthy brothers and sisters served as a control group. Main outcome measures were IGF-I, IGFBP-3 and peak GH level after a combined GHRH-arginine test. Other pituitary hormone deficits are diagnosed based on serum levels of the concerning hormones. The size of the pituitary gland was measured on MRI images. RESULTS: In PWS adults, IGF-I levels were low and IGFBP-3 levels normal when compared to healthy controls. GHD was diagnosed in 8-38% of the PWS patients, depending on the criteria used. Hypogonadism was present in 87% of the patients. Hypothyroidism and adrenal insufficiency could also be demonstrated. Anterior pituitary size was lower in PWS individuals when compared to healthy controls. CONCLUSION: In this study, pituitary hormone deficiencies are demonstrated in a considerable number of adults with PWS, hypogonadism and GHD being most prominent. Furthermore, the anterior pituitary is smaller in comparison with healthy controls.


Subject(s)
Human Growth Hormone/metabolism , Pituitary Gland/metabolism , Prader-Willi Syndrome/physiopathology , Adiposity , Adolescent , Adult , Arginine , Case-Control Studies , Endocrine Glands/physiopathology , Female , Growth Hormone-Releasing Hormone , Human Growth Hormone/deficiency , Humans , Insulin-Like Growth Factor I/metabolism , Male , Organ Size , Pituitary Gland/pathology , Pituitary Gland/physiopathology , Pituitary Hormones/deficiency , Prader-Willi Syndrome/pathology , Young Adult
18.
AJNR Am J Neuroradiol ; 31(8): 1385-9, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20413604

ABSTRACT

BACKGROUND AND PURPOSE: Although pineoblastoma is the main brain abnormality associated with hereditary retinoblastoma, recent studies suggest an association with pineal cysts. This association is important because some pineoblastomas mimic pineal cysts. If there is a relationship, then radiologists should be aware of it because diagnostic confusion is possible. Mental retardation and congenital brain anomalies are also reported in patients with retinoblastoma, mostly in combination with 13q deletion syndrome. In this retrospective study, the presence of brain abnormalities on MR images in a large group of consecutive patients with retinoblastoma is evaluated. MATERIALS AND METHODS: Brain MR images of 168 patients with retinoblastoma from 1989 to 2009 were evaluated by 2 radiologists for tumors, structural anomalies, myelinization, and coincidental findings. Clinical records were reviewed for laterality, heredity, and the presence of the 13q deletion syndrome. RESULTS: The hereditary group (patients with bilateral and unilateral proved RB1-germline mutation) included 90 (54%) of 168 patients. Seven patients had 13q deletion syndrome. Normal findings on brain MR images were seen in 150 (89%) patients. Five pineoblastomas were detected, all in patients with hereditary retinoblastoma (5.5% in the hereditary subgroup). Nine pineal cysts were detected (2.2% in the hereditary subgroup). Corpus callosum agenesis was found in 1 patient and a Dandy-Walker variant in 1 patient, both in combination with 13q deletion syndrome. CONCLUSIONS: Pineoblastoma is associated with hereditary retinoblastoma, and structural brain abnormalities are restricted to patients with the 13q deletion syndrome. The incidence of pineal cysts in patients with retinoblastomas is similar to that in healthy children and is not associated with hereditary retinoblastoma.


Subject(s)
Brain Neoplasms/pathology , Magnetic Resonance Imaging , Pineal Gland/pathology , Pinealoma/pathology , Retinal Neoplasms/pathology , Retinoblastoma/pathology , Aicardi Syndrome/genetics , Aicardi Syndrome/pathology , Brain/abnormalities , Brain Neoplasms/congenital , Brain Neoplasms/genetics , Child, Preschool , Chromosome Deletion , Chromosome Disorders/pathology , Chromosomes, Human, Pair 13 , Dandy-Walker Syndrome/genetics , Dandy-Walker Syndrome/pathology , Female , Humans , Infant , Infant, Newborn , Male , Pinealoma/congenital , Pinealoma/genetics , Retinal Neoplasms/congenital , Retinal Neoplasms/genetics , Retinoblastoma/congenital , Retinoblastoma/genetics
20.
AJNR Am J Neuroradiol ; 31(2): 237-45, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19833805

ABSTRACT

BACKGROUND AND PURPOSE: AES contrast-enhancement is recognized in a substantial number of retinoblastoma-affected eyes. We retrospectively investigated the histopathologic basis of AES contrast-enhancement on MR images in retinoblastoma. MATERIALS AND METHODS: Pretreatment contrast-enhanced MR images were obtained from 42 children with retinoblastoma. Forty-two enucleated eyes were included in this study, AES enhancement was evaluated by using a 3-point score, and these data were correlated with clinical, MR imaging, and histopathologic findings. Additionally, 14 specimens were immunohistochemically analyzed for CD31, VEGF, and Flt-1 expression. Statistical correlations with AES enhancement were assessed by using a linear-by-linear association test and univariate and multivariate ordinal regressions. RESULTS: The degree of abnormal AES enhancement was moderate in 15 (36%) eyes and strong in 14 (33%) eyes, whereas 13 (31%) eyes showed normal AES enhancement. In multivariate analysis, the degree of AES enhancement showed statistically significant correlations with iris surface-vessel count (P = .05) and optic nerve invasion (P = .04) in the enucleated eye and with tumor volume (P = .02) as detected on MR imaging. No significant associations between AES enhancement and VEGF expression in the iris were observed. Flt-1 (P = .04) staining in iris stroma and IA as detected with CD31 staining (P = .009) both yielded a statistically significant positive correlation with abnormal AES enhancement. CONCLUSIONS: The degree of abnormal AES enhancement on MR imaging in retinoblastoma reflects angiogenesis in the iris. AES enhancement is also a hallmark of advanced retinoblastoma because its degree correlates with tumor volume and optic nerve invasion.


Subject(s)
Anterior Chamber/pathology , Contrast Media , Eye Neoplasms/pathology , Magnetic Resonance Imaging/methods , Neovascularization, Pathologic/pathology , Retinoblastoma/pathology , Biopsy , Child, Preschool , Eye Enucleation , Eye Neoplasms/blood supply , Eye Neoplasms/metabolism , Female , Follow-Up Studies , Humans , Immunohistochemistry , Infant , Male , Neovascularization, Pathologic/metabolism , Platelet Endothelial Cell Adhesion Molecule-1/metabolism , Retinoblastoma/blood supply , Retinoblastoma/metabolism , Retrospective Studies , Vascular Endothelial Growth Factor A/metabolism , Vascular Endothelial Growth Factor Receptor-1/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...