Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 9(1): 16484, 2019 11 11.
Article in English | MEDLINE | ID: mdl-31712687

ABSTRACT

The urinary tissue inhibitor of metalloproteinases-2 and insulin-like growth factor-binding protein 7 ([TIMP-2]∙[IGFBP7]) have been introduced to improve risk prediction of severe acute kidney injury (AKI) within 12 hours of measurement. We performed a prospective cohort study to evaluate if the predictive value of [TIMP-2]∙[IGFBP7] for AKI might continue after 12 hours. We enrolled 442 critically ill adult patients from June to December 2016. Urine samples were collected at admission for [TIMP-2]∙[IGFBP7] measurement. Baseline patient characteristics were recorded including patients' demographics, prior health history, and the main reason for admission to build a logistic regression model to predict AKI. AKI occurrence differed between patients with [TIMP-2]∙[IGFBP7] ≤0.3 and >0.3 (ng/ml)2/1000 (31.9% and 68.10% respectively; p < 0.001). Patients with AKI had higher biomarker values compared to those without AKI (0.66 (0.21-2.84) vs 0.22 (0.08-0.63) (ng/ml)2/1000; p < 0.001). [TIMP-2]∙[IGFBP7] at ICU admission had a lower performance in predicting AKI at any stage within 48 hours and 7 days after measurement (area under the receiver operating characteristic curve (AUC) equal to 0.70 (95%CI 0.65-0.76), AUC 0.68 (95%CI 0.63-0.73)). In the logistic regression model, 0.1 (ng/ml)2/1000-unit increment was likely to increase the risk of AKI by 2% (p = 0.002).


Subject(s)
Acute Kidney Injury/diagnosis , Acute Kidney Injury/urine , Biomarkers , Tissue Inhibitor of Metalloproteinase-2/urine , Acute Kidney Injury/etiology , Adult , Aged , Aged, 80 and over , Critical Care , Female , Hospitalization , Humans , Intensive Care Units , Kidney Function Tests , Male , Middle Aged , Odds Ratio , ROC Curve , Risk Assessment , Risk Factors , Time Factors
2.
Clin Kidney J ; 12(2): 300-307, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30976412

ABSTRACT

BACKGROUND: Since 2005, three human clinical trials have been performed with the Wearable Artificial Kidney (WAK) and Wearable Ultrafiltration (WUF) device. The lack of an adequate vascular access (VA) has been pointed out as the main limitation to their implementation. Based on the current level of understanding, we will make the first conceptual proposal of an adequate VA suitable for the WAK and the WUF. METHODS: All the literature related to WAK and WUF was reviewed. Based on eight main publications the VA major characteristics were defined: a mean blood flow of 100 mL/min; the capability to allow prolonged and frequent dialysis treatments, without interfering in activities of daily living (ADL); safe and convenient connection/disconnection systems; reduced risk of biofilm formation and coagulation; high biocompatibility. A research was done in order to answer to each necessary technological prerequisites. RESULTS: The use of a device similar to a CVC with a 5Fr lumen, seems to be the most feasible option. Totally subcutaneous port devices, like the LifeSite(R) or Dialock (R) systems can be a solution to allow WAK or WUF to operate continuously while patients carry out their ADL. Recently, macromolecules that reduce the risk of thrombosis and infection and are integrated into a CVC have been developed and have the capability of overcoming these major limitations. CONCLUSION: With an adequate VA, portable HD devices can be acceptable options to address several unmet clinical needs of HD patients.

SELECTION OF CITATIONS
SEARCH DETAIL