1.
Rev Sci Instrum ; 90(7): 073501, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31370478

ABSTRACT

A portable Runaway Electron Imaging and Spectrometry System (REIS) was developed in ENEA-Frascati to measure synchrotron radiation spectra from in-flight runaway electrons in tokamaks. The REIS is a wide-angle optical system collecting simultaneously visible and infrared emission spectra using an incoherent bundle of fibers, in a spectral range that spans from 500 nm to 2500 nm, and visible images using a CCD color microcamera at a rate of 25 frames/s. The REIS system is supervised and managed using a dedicated LabVIEW program to acquire data simultaneously from three spectrometers every 20 ms (configurable down to 10 ms). An overview of the REIS architecture and acquisition system and resulting experimental data obtained in FTU are presented and discussed in this paper.

2.
Regen Biomater ; 6(1): 21-28, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30740239

ABSTRACT

In the field of tissue engineering the choice of materials is of great importance given the possibility to use biocompatible polymers produced by means of biotechnology. A large number of synthetic and natural materials have been used to this purpose and processed into scaffolds using Electrospinning technique. Among materials that could be used for the fabrication of scaffold and degradable membranes, natural polymers such as collagen, elastin or fibroin offer the possibility to design structures strictly similar to the extracellular matrix (ECM). Biotechnology and genetic engineering made possible the advent of a new class of biopolymers called protein-based polymers. One example is represented by the silk-elastin-proteins that combine the elasticity and resilience of elastin with the high tensile strength of silk-fibroin and display engineered bioactive sequences. In this work, we use electrospinning technique to produce a fibrous scaffold made of the co-recombinamer Silk-ELR. Obtained fibres have been characterized from the morphological point of view. Homogeneity and morphology have been explored using Scanning Electron Microscopy. A thorough study regarding the influence of Voltage, flow rate and distance have been carried out to determine the appropriate parameters to obtain the fibrous mats without defects and with a good distribution of diameters. Cytocompatibility has also been in vitro tested. For the first time we use the co-recombinamer Silk-ELR for the fabrication of a 2.5 angioplasty balloon coating. This structure could be useful as a coated scaffold for the regeneration of intima layer of vessels.

3.
Biofabrication ; 8(4): 045009, 2016 11 15.
Article in English | MEDLINE | ID: mdl-27845938

ABSTRACT

Coronary angioplasty is the most widely used technique for removing atherosclerotic plaques in blood vessels. The regeneration of the damaged intima layer after this treatment is still one of the major challenges in the field of cardiovascular tissue engineering. Different polymers have been used in scaffold manufacturing in order to improve tissue regeneration. Elastin-mimetic polymers are a new class of molecules that have been synthesized and used to obtain small diameter fibers with specific morphological characteristics. Elastin-like polymers produced by recombinant techniques and called elastin-like recombinamers (ELRs) are particularly promising due to their high degree of functionalization. Generally speaking, ELRs can show more complex molecular designs and a tighter control of their sequence than other chemically synthetized polymers Rodriguez Cabello et al (2009 Polymer 50 5159-69, 2011 Nanomedicine 6 111-22). For the fabrication of small diameter fibers, different ELRs were dissolved in 2,2,2-fluoroethanol (TFE). Dynamic light scattering was used to identify the transition temperature and get a deep characterization of the transition behavior of the recombinamers. In this work, we describe the use of electrospinning technique for the manufacturing of an elastic fibrous scaffold; the obtained fibers were characterized and their cytocompatibility was tested in vitro. A thorough study of the influence of voltage, flow rate and distance was carried out in order to determine the appropriate parameters to obtain fibrous mats without beads and defects. Moreover, using a rotating mandrel, we fabricated a tubular scaffold in which ELRs containing different cell adhesion sequences (mainly REDV and RGD) were collected. The stability of the scaffold was improved by using genipin as a crosslinking agent. Genipin-ELRs crosslinked scaffolds  show a good stability and fiber morphology. Human umbilical vein endothelial cells  were used to assess the in vitro bioactivity of the cell adhesion domains within the backbone of the ELRs.


Subject(s)
Biocompatible Materials/chemistry , Elastin/chemistry , Nanofibers/chemistry , Tissue Scaffolds/chemistry , Amino Acid Sequence , Atherosclerosis/metabolism , Atherosclerosis/pathology , Atherosclerosis/therapy , Biocompatible Materials/pharmacology , Biocompatible Materials/therapeutic use , Cell Adhesion/drug effects , Cell Survival/drug effects , Cross-Linking Reagents/chemistry , Dynamic Light Scattering , Human Umbilical Vein Endothelial Cells , Humans , Iridoids/chemistry , Microscopy, Electron, Scanning , Polymers/chemistry , Tissue Engineering/methods
4.
Analyst ; 141(4): 1250-6, 2016 Feb 21.
Article in English | MEDLINE | ID: mdl-26738973

ABSTRACT

A novel class of probes for fluorescence detection was developed and combined to microgel particles for a high sensitive fluorescence detection of nucleic acids. A double strand probe with an optimized fluorescent-quencher couple was designed for the detection of different lengths of nucleic acids (39 nt and 100 nt). Such probe proved efficient in target detection in different contests and specific even in presence of serum proteins. The conjugation of double strand probes onto polymeric microgels allows for a sensitive detection of DNA sequences from HIV, HCV and SARS corona viruses with a LOD of 1.4 fM, 3.7 fM and 1.4 fM, respectively, and with a dynamic range of 10(-9)-10(-15) M. Such combination enhances the sensitivity of the detection of almost five orders of magnitude when compared to the only probe. The proposed platform based on the integration of innovative double strand probe into microgels particles represents an attractive alternative to conventional sensitive DNA detection technologies that rely on amplifications methods.


Subject(s)
DNA, Viral/analysis , DNA, Viral/genetics , Oligonucleotide Probes/chemistry , Base Sequence , DNA, Viral/chemistry , Fluorescent Dyes/chemistry , Gels , Limit of Detection , Oligonucleotide Probes/genetics , Spectrometry, Fluorescence
5.
Lab Chip ; 15(16): 3278-85, 2015 Aug 21.
Article in English | MEDLINE | ID: mdl-26168054

ABSTRACT

A camera-based light scattering approach coupled with a viscoelasticity-induced cell migration technique has been used to characterize the morphological properties of erythrocytes in microfluidic flows. We have obtained the light scattering profiles (LSPs) of individual living cells in microfluidic flows over a wide angular range and matched them with scattering simulations to characterize their morphological properties. The viscoelasticity-induced 3D cell alignment in microfluidic flows has been investigated by bright-field and holographic microscopy tracking, where the latter technique has been used to obtain precise cell alignment profiles in-flow. Such information allows variable cell probability control in microfluidic flows at very low viscoelastic polymer concentrations, obtaining cell measurements that are almost physiological. Our results confirm the possibility of precise, label-free analysis of individual living erythrocytes in microfluidic flows.


Subject(s)
Erythrocytes/cytology , Light , Scattering, Radiation , Cell Survival , Erythrocytes/metabolism , Humans , Microfluidic Analytical Techniques/instrumentation , Microscopy, Electron, Scanning , Temperature
6.
J Mater Chem B ; 3(1): 53-58, 2015 Jan 07.
Article in English | MEDLINE | ID: mdl-32261924

ABSTRACT

The fabrication of a scaffold able to control the positioning of AuNPs and to trap and concentrate target molecules inside them is a promising idea for a large variety of sensing applications. In this work, we designed and fabricated a scaffold of already-prepared 20 nm AuNPs encapsulated in a PNIPAAm hydrogel and utilizing surface enhanced Raman spectroscopy (SERS), we used it as a sensor with remarkably low limits of detection. In fact, as the target is trapped inside the hydrogel, the following takes place: (a) the concentration of the target increases dramatically and (b) the localization of the AuNPs and thus of the hotspots (areas with extremely high SERS enhancement factors) work synergistically, improving the sensing ability of the scaffold. The SERS enhancement ability of our scaffolds was checked with adenine, 2-naphthalenethiol and melamine molecules; the trapping efficiency was investigated for the melamine and a partition coefficient of k = 5 × 105 was found. Finally, by focusing on a single PNIPAAm hydrogel with encapsulated AuNPs, we managed to detect 10-6 M or rather 108 molecules of melamine trapped inside the scaffold.

7.
Analyst ; 139(20): 5239-46, 2014 Oct 21.
Article in English | MEDLINE | ID: mdl-25133272

ABSTRACT

A straightforward way to measure separated micrometric sized particles in microfluidic flow is reported. The light scattering profile (LSP) of each single particle is fully characterized by using a CMOS-camera based small angle light scattering (SALS) apparatus, ranging from 2° up to 30°. To ensure controlled particle passage through the incident laser, a viscoelastic 3D alignment effect by viscoelastic induced particle migration has been implemented in a simple and cost-effective microfluidic device. Different polystyrene particle sizes are measured in microfluidic flows and the obtained scattering signatures are matched with the Lorenz-Mie based scattering theory. The results confirm the possibility of using this apparatus for real multiplex particle analyses in microfluidic particle flows.


Subject(s)
Microfluidic Analytical Techniques/methods , Polystyrenes/chemistry , Elasticity , Light , Particle Size , Refractometry , Scattering, Radiation , Viscosity
8.
J Colloid Interface Sci ; 389(1): 220-9, 2013 Jan 01.
Article in English | MEDLINE | ID: mdl-23031494

ABSTRACT

There is a growing interest in identifying biomacromolecules such as proteins and peptides to functionalize metallic surfaces through noncovalent binding. One method for functionalizing materials without fundamentally changing their inherent structure is using biorecognition moieties. Here, we proved a general route to select a biomolecule adhesive motif for surface functionalization by comprehensively screening phage displayed peptides. In particular, we selected a genetically engineered M13 bacteriophage and a linear dodecapeptide derived from its pIII domain for recognizing gold surfaces in a specific and selective manner. In the phage context, we demonstrated the adhesive motif was capable to adsorb on gold in a preferential way with a morphological and viscoelastic signature of the adsorbed layer as evidenced by QCM-D and AFM investigations. Out of the phage context, the linear dodecapeptide is reproducibly found to adhere to the gold surface, and by quantitative SPR measurements, high affinity constants (K(eq)~10(6)M(-1), binding energy ~-8 kcal/mol) were determined. We proved that the interactions occurring at gold interface were mainly hydrophobic as a consequence of high frequency of hydrophobic residues in the peptide sequence. Moreover, by CD, molecular dynamics and steered molecular dynamics, we demonstrated that the molecular flexibility only played a minor role in the peptide adsorption. Such noncovalent but specific modification of inorganic surfaces through high affinity biomolecule adsorption represents a general strategy to modulate the functionality of multipurpose metallic surfaces.


Subject(s)
Bacteriophage M13/chemistry , Gold/chemistry , Peptide Library , Peptides/chemistry , Adsorption , Amino Acid Sequence , Bacteriophage M13/genetics , Bacteriophage M13/ultrastructure , Genetic Engineering , Hydrophobic and Hydrophilic Interactions , Surface Plasmon Resonance , Surface Properties
9.
Biomacromolecules ; 13(11): 3510-21, 2012 Nov 12.
Article in English | MEDLINE | ID: mdl-23030686

ABSTRACT

The requirement of a multifunctional scaffold for tissue engineering capable to offer at the same time tunable structural properties and bioactive interface is still unpaired. Here we present three-dimensional (3D) biodegradable polymeric (PCL) scaffolds with controlled morphology, macro-, micro-, and nano-mechanical performances endowed with bioactive moieties (RGD peptides) at the surface. Such result was obtained by a combination of rapid prototyping (e.g., 3D fiber deposition) and surface treatment approach (aminolysis followed by peptide coupling). By properly designing process conditions, a control over the mechanical and biological performances of the structure was achieved with a capability to tune the value of compressive modulus (in the range of 60-90 MPa, depending on the specific lay-down pattern). The macromechanical behavior of the proposed scaffolds was not affected by surface treatment preserving bulk properties, while a reduction of hardness from 0.50-0.27 GPa to 0.1-0.03 GPa was obtained. The penetration depth of the chemical treatment was determined by nanoindentation measurements and confocal microscopy. The efficacy of both functionalization and the following bioactivation was monitored by analytically quantifying functional groups and/or peptides at the interface. NIH3T3 fibroblast adhesion studies evidenced that cell attachment was improved, suggesting a correct presentation of the peptide. Accordingly, the present work mainly focuses on the effect of the surface modification on the mechanical and functional performances of the scaffolds, also showing a morphological and analytical approach to study the functionalization/bioactivation treatment, the distribution of immobilized ligands, and the biological features.


Subject(s)
Polyesters/chemistry , Tissue Engineering/methods , Tissue Scaffolds , 3T3 Cells , Animals , Biocompatible Materials/chemistry , Cell Adhesion , Cell Line , Materials Testing , Mice , Polymers/chemistry , Surface Properties
10.
Radiol Med ; 117(3): 507-18, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22228130

ABSTRACT

PURPOSE: The efficient use of computed tomography (CT) and magnetic resonance imaging (MRI) equipment necessitates establishing adequate quality-control (QC) procedures. In particular, the accuracy of slice thickness (ST) requires scan exploration of phantoms containing test objects (plane, cone or spiral). To simplify such procedures, a novel phantom and a computerised LabView-based procedure have been devised, enabling determination of full width at half maximum (FWHM) in real time. MATERIALS AND METHODS: The phantom consists of a polymethyl methacrylate (PMMA) box, diagonally crossed by a PMMA septum dividing the box into two sections. The phantom images were acquired and processed using the LabView-based procedure. RESULTS: The LabView (LV) results were compared with those obtained by processing the same phantom images with commercial software, and the Fisher exact test (F test) was conducted on the resulting data sets to validate the proposed methodology. CONCLUSIONS: In all cases, there was no statistically significant variation between the two different procedures and the LV procedure, which can therefore be proposed as a valuable alternative to other commonly used procedures and be reliably used on any CT and MRI scanner.


Subject(s)
Magnetic Resonance Imaging , Tomography, X-Ray Computed , Phantoms, Imaging , Polymethyl Methacrylate , Quality Control
12.
Int J Artif Organs ; 31(12): 1017-26, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19115193

ABSTRACT

The present review aims to describe the potential applications of gene delivery systems to tissue engineering and central nervous system diseases. Some key experimental work has been done with interesting results, but the subject is far from being fully explored. The combined approach of gene therapy and material science has a huge potential to improve the therapeutic approaches now available for a wide range of medical applications. Focus is given to this multidisciplinary strategy in neurodegenerative pathologies, where the use of polymeric matrices as gene carriers might make a crucial difference.


Subject(s)
Central Nervous System Diseases/therapy , Gene Transfer Techniques , Genetic Therapy , Tissue Engineering , Biocompatible Materials , Humans , Polymers
13.
Rev Sci Instrum ; 78(10): 105102, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17979453

ABSTRACT

A laser fringe projection system based on a pair of identical acousto-optic TeO(2) deflectors operated at the same frequency and using tangential phase matching anisotropic interaction is demonstrated, achieving large bandwidth and high efficiency. A 40 MHz bandwidth and an acousto-optic efficiency higher than 60% have been measured at wavelength of 514 nm. The specific pris-matic configuration of the in-house developed deflectors greatly facilitates optical alignment of the instrument. The spatial period of the interference fringes can be dynamically controlled over almost one decade by tuning the frequency of the acoustic carriers.


Subject(s)
Acoustics , Lenses , Lighting/instrumentation , Refractometry/instrumentation , Equipment Design , Equipment Failure Analysis , Lighting/methods , Refractometry/methods , Reproducibility of Results , Sensitivity and Specificity
14.
J Mater Sci Mater Med ; 18(4): 653-60, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17546428

ABSTRACT

In the present study, the synthesis of a semi-Interpenetrating Polymer Network (semi-IPN) incorporating linear poly-(epsilon-caprolactone) (PCL) into cross-linked poly-(2-hydroxyethylmethacrilate) (PHEMA) reinforced with hydroxyapatite (HA) has been described. The aim of this study was to improve the mechanical and biological performance of the PHEMA/PCL in the hydrated state, for orthopaedic applications. The swelling behaviour, mechanical (compressive and tensile) and surface chemical-physical (morphology, stoichiometric composition) characterisation of the novel HA reinforced composite based on PHEMA/PCL polymer matrix, PHEMA/PCL 70/30 (w/w) + 50% (w/w) HA (PHEMA/PCL/HA), were evaluated. Furthermore, a preliminary in vitro biological evaluation was also performed on the composite using a fully characterised primary human osteoblast-like (HOB) cell model. The inclusion of HA in the composite improved the mechanical performance in the swollen state, with values of elastic modulus in a similar range to that of trabecular bone. The composite surfaces showed a porous, irregular topography with the presence of: oxygen (O), carbon (C); phosphorous (P); calcium (Ca) where the Ca/P ratio was 1.78. Biological evaluation indicated undetectable weight loss of the sample, no release of toxic leachables from the composite and pH values within an acceptable range for cell growth. The results indicate that the novel PHEMA/PCL/HA composite is a promising candidate as filler or substitute for spongy bone for orthopaedic applications.


Subject(s)
Biocompatible Materials/chemistry , Caproates/chemistry , Chemistry, Physical/methods , Durapatite/chemistry , Lactones/chemistry , Polyhydroxyethyl Methacrylate/chemistry , Cells, Cultured , Compressive Strength , Electron Probe Microanalysis , Formazans/metabolism , Humans , Hydrogen-Ion Concentration , Osteoblasts/cytology , Osteoblasts/metabolism , Osteoblasts/ultrastructure , Polymers/chemistry , Porosity , Surface Properties , Tensile Strength , Tetrazolium Salts/metabolism , Water/chemistry
15.
Biomaterials ; 28(20): 3101-9, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17412415

ABSTRACT

The ability of a cellular construct to guide and promote tissue repair strongly relies on three components, namely, cell, scaffold and growth factors. We aimed to investigate the osteopromotive properties of cellular constructs composed of poly-epsilon-caprolactone (PCL) and rabbit bone marrow stromal cells (BMSCs), or BMSCs engineered to express bone morphogenetic protein 4 (BMP4). Highly porous biodegradable PCL scaffolds were obtained via phase inversion/salt leaching technique. BMSCs and transfected BMSCs were seeded within the scaffolds by using an alternate flow perfusion system and implanted into non-critical size defects in New Zealand rabbit femurs. In vivo biocompatibility, osteogenic and angiogenic effects induced by the presence of scaffolds were assessed by histology and histomorphometry of the femurs, retrieved 4 and 8 weeks after surgery. PCL without cells showed scarce bone formation at the scaffold-bone interface (29% bone/implant contact and 62% fibrous tissue/implant contact) and scarce PCL resorption (16%). Conversely, PCL seeded with autologous BMSCs stimulated new tissue formation into the macropores of the implant (20%) and neo-tissue vascularization. Finally, the BMP4-expressing BMSCs strongly favoured osteoinductivity of cellular constructs, as demonstrated by a more extensive bone/scaffold contact.


Subject(s)
Biocompatible Materials/chemistry , Bone Marrow Cells/cytology , Bone Morphogenetic Proteins/metabolism , Caproates/chemistry , Femur/surgery , Lactones/chemistry , Stromal Cells/cytology , Animals , Biocompatible Materials/metabolism , Bone Marrow Cells/metabolism , Bone Morphogenetic Protein 4 , Bone Morphogenetic Proteins/genetics , Cell Transplantation/methods , Femur/growth & development , Femur/metabolism , Genetic Vectors/genetics , Osteogenesis , Polymers/chemistry , Rabbits , Stromal Cells/metabolism , Stromal Cells/transplantation , Time Factors , Tissue Engineering/methods , Transfection , Transplantation, Autologous
16.
Int J Nanomedicine ; 2(4): 689-96, 2007.
Article in English | MEDLINE | ID: mdl-18203435

ABSTRACT

The non-specific adhesion of spherical micro- and nano-particles to a cell substrate is investigated in a parallel plate flow chamber. Differently from prior in-vitro analyses, the total volume of the particles injected into the flow chamber is kept fixed whilst the particle diameter is changed in the range 0.5-10 microm. It is shown that: (i) the absolute number of particles adherent to the cell layer per unit surface decreases with the size of the particle as d(-1.7); (ii) the volume of the particles adherent per unit surface increases with the size of the particles as d(+1.3). From these results and considering solely non-specific particles, the following hypothesis are generated (i) use the smallest possible particles in biomedical imaging and (ii) use the largest possible particles in drug delivery.


Subject(s)
Cell Adhesion/physiology , Endothelial Cells/physiology , Flow Injection Analysis/methods , Microspheres , Models, Biological , Adhesiveness , Cells, Cultured , Computer Simulation , Humans , Particle Size , Shear Strength
17.
J Appl Biomater Biomech ; 5(3): 149-57, 2007.
Article in English | MEDLINE | ID: mdl-20799184

ABSTRACT

Scaffold design plays a pivotal role in tissue engineering and regenerative medicine approaches for creating biological alternatives for implants. The crucial aspect in scaffold design consists of the development of highly porous scaffolds, with strict control of porosity features (porosity degree and pore sizes), continuing to provide an adequate mechanical response, mainly in compressive loading, both in vitro and in vivo conditions. A study was undertaken of three-dimensional (3D) porous scaffolds obtained from poly epsilon-caprolactone solution through the phase inversion/salt leaching technique. In particular, the influence of structural porosity features on mechanical response was investigated to establish the correlation between structural parameters and compressive response. Scaffold porosity features can be controlled by changing the amount and size of the porogen agent used. Mechanical response in compression is consistent with porosity features: elastic modulus calculated in the toe region range (0-0.1 of total strain) shows an increase from 0.24-1.85 MPa coherently, with a reduction in pore volume fraction from 84.9 to 45.7%. Such behavior can be predicted by using analytical models for the determination of the elastic modulus of cellular solids based on the morphological assumption of cubic cell structure (cubic open cell (COC) and cubic closed cells (CCC)). Compressive behavior prediction offered by the proposed models is in agreement with the experimental results in the case of higher pore volume fractions according to the theoretical results of other investigators.

18.
Int J Artif Organs ; 29(7): 719-25, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16874679

ABSTRACT

Porous poly(epsilon-caprolactone) (PCL) is used as long-term bioresorbable scaffold for bone tissue engineering. The bone regeneration process can be enhanced by addition of carbonated apatites (AP). This study was aimed at evaluating the influence of the PCL/AP ratio on the in vitro degradation and bioactivity of PCL-AP composites. To this purpose, PCL-AP samples were synthesised with the following PCL/AP weight/weight ratios: 50/50, 60/40 and 75/25. Vibrational IR and Raman spectroscopies coupled to thermogravimetry (TG) and differential scanning calorimetry (DSC) were used to investigate the in vitro degradation mechanism in different media: 0.01 M NaOH solution (pH=12), saline phosphate buffer at pH 7.5 (SPB), esterase in SPB and simulated body fluid (SBF) at pH 7.5. The latter medium was used to evaluate the bioactivity of the composites. A control PCL sample was analysed before the addition of the AP component. As regards the untreated samples, the method of synthesis utilised for preparing the composite was found to enhance the crystallinity degree. The AP component revealed to be constituted of a B-type carbonated hydroxyapatite with a 3% carbonate content. After 28 days of treatment, the samples showed different degradation patterns and extents depending on the degradation medium, the starting PCL crystallinity and composite composition. Weight measurements, Raman and TG analyses revealed deposition of an apatitic phase on all the composites immersed in SBF. Therefore, all the samples displayed a good bioactivity; the sample which showed the most pronounced apatitic deposition was 50/50, i.e. that containing the highest amount of AP.


Subject(s)
Apatites/metabolism , Bone and Bones/metabolism , Caproates/metabolism , Lactones/metabolism , Tissue Engineering , Crystallization , Extracellular Matrix/metabolism , Humans , Spectrum Analysis , Spectrum Analysis, Raman , Vibration
19.
Ann Biomed Eng ; 34(4): 633-41, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16568349

ABSTRACT

The effective longitudinal diffusion of nanovectors along non-permeable and permeable capillaries has been studied considering the contribution of molecular and convective diffusion based on the Taylor's theory of shear dispersion. The problem is of importance in the transport of nanovectors used for the intravascular delivery of drugs and contrast agents. It has been shown that for a given capillary size and hemodynamic conditions a critical radius acr exists for which the effective longitudinal diffusion along the capillary has a minimum: Nanovectors with a < acr diffuse mainly by Brownian diffusion whereas nanovectors with a < acr diffuse mainly by convection and the effective diffusion coefficient grows with a. In permeable conduits, the effective diffusion reduces significantly compared to normal non-leaky vessels and it has been derived that acr grows almost linearly with the hydraulic permeability Lp of blood vessels. It has been shown that the blood conduits with the largest effective longitudinal diffusivity could be preferentially targeted by the circulating vectors. Based on these findings, the following strategies are proposed to increase the number of nanovectors targeting the tumor vessels: (i) The use of nanovectors with a critical radius for normal vessels, (ii) the injecting of bolus of nanovectors with different radii, and (iii) the normalization of the tumor vasculature. Finally, it has been emphasized that the size of the vector should be selected depending on the body district where the tumoral mass is developing and on the type, malignancy, and state of the tumor.


Subject(s)
Models, Cardiovascular , Nanostructures , Neoplasms/blood supply , Animals , Drug Delivery Systems , Humans , Neoplasms/drug therapy
20.
J Biomed Mater Res A ; 76(1): 151-62, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16258959

ABSTRACT

Polycaprolactone (PCL), a semicrystalline linear resorbable aliphatic polyester, is a good candidate as a scaffold for bone tissue engineering, due to its biocompatibility and biodegradability. However, the poor mechanical properties of PCL impair its use as scaffold for hard tissue regeneration, unless mechanical reinforcement is provided. To enhance mechanical properties and promote osteoconductivity, hydroxyapatite (HA) particles were added to the PCL matrix: three PCL-based composites with different volume ratio of HA (13%, 20%, and 32%) were studied. Mechanical properties and structure were analysed, along with biocompatibility and osteoconductivity. The addition of HA particles (in particular in the range of 20% and 32%) led to a significant improvement in mechanical performance (e.g., elastic modulus) of scaffold. Saos-2 cells and osteoblasts from human trabecular bone (hOB) retrieved during total hip replacement surgery were seeded onto 3D PCL samples for 1-4 weeks. Following the assessment of cell viability, proliferation, morphology, and ALP release, HA-loaded PCL was found to improve osteoconduction compared to the PCL alone. The results indicated that PCL represents a potential candidate as an efficient substrate for bone substitution through an accurate balance between structural/ mechanical properties of polymer and biological activities.


Subject(s)
Biocompatible Materials , Bone Regeneration/drug effects , Durapatite , Osteoblasts/drug effects , Polyesters , Alkaline Phosphatase/metabolism , Biocompatible Materials/administration & dosage , Biomechanical Phenomena , Bone Regeneration/physiology , Cell Line , Cell Proliferation/drug effects , Durapatite/administration & dosage , Humans , Materials Testing , Microscopy, Electron, Scanning , Osteoblasts/cytology , Osteoblasts/physiology , Particle Size , Polyesters/administration & dosage , Surface Properties , Tissue Engineering
SELECTION OF CITATIONS
SEARCH DETAIL
...