Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 321
Filter
1.
Article in English | MEDLINE | ID: mdl-38669595

ABSTRACT

OBJECTIVES: To investigate the association between varying degrees of abnormality in the uterine artery Doppler pulsatility index (UtA-PI) and adverse perinatal outcomes. METHODS: Prospective study of 33,364 women who gave birth to singleton, non-anomalous babies in Oxford, following universal measurement of UtA-PI in mid-pregnancy. Relative risk ratios for the primary outcomes of extended perinatal mortality and live birth with severe small-for-gestational-age (SGA) were calculated by multinomial logistic regression, for early preterm birth (<34+0) and late preterm/term birth (≥34+0). The risks were also investigated for iatrogenic preterm birth or a composite adverse outcome before 34+0 weeks. RESULTS: Compared with women with normal UtA-PI, the risk of extended perinatal mortality before 34+0 weeks was higher in women with UtA-PI >90th centile (RRR 4.7, 95% CI 2.7-8.0, p<0.001), but this was not demonstrated in later births. The risk of severe SGA birth was strongly associated with abnormal UtA-PI for both early births (RRR 26.0, 95% CI 11.6-58.2, p<0.001), and later births (RRR 2.3, 95% CI 1.8-2.9, p<0.001). Women with a raised UtA-PI were more likely to undergo early iatrogenic birth (RRR 7.8, 95% CI 5.5-11.2, p<0.001). For each of the outcomes and the composite outcome, the risk increased significantly in association with the degree of abnormality, through the 90th, 90-94th, 95-99th and >99th centiles (ptrend<0.001). CONCLUSIONS: An elevated UtA-PI is a key predictor of iatrogenic preterm birth, severe SGA and perinatal loss up to 34+0 weeks. It is the 90th centile that should be used, and management should be further tailored to the degree of abnormality, as pregnancies with very raised UtA-PI measurements constitute a group at extreme risk. This article is protected by copyright. All rights reserved.

2.
Ultrasound Obstet Gynecol ; 59(4): 490-496, 2022 04.
Article in English | MEDLINE | ID: mdl-34396614

ABSTRACT

OBJECTIVE: To evaluate whether clinical phenotypes of small-for-gestational-age (SGA) fetuses can be identified and used for adverse perinatal outcome risk stratification to facilitate clinical decision-making. METHODS: This was a multicenter observational cohort study conducted in two tertiary care university hospitals. SGA fetuses were classified according to maternal, fetal and placental conditions using a two-step cluster algorithm, in which fetuses with more than one condition were assigned to the cluster associated with the highest mortality risk. Delivery and perinatal outcomes were compared using chi-square test among SGA clusters, and the associations between outcomes and each cluster were evaluated by calculating odds ratios (OR), adjusted for gestational age. RESULTS: The study included 17 631 consecutive singleton pregnancies, of which 1274 (7.2%) were defined as SGA at birth according to INTERGROWTH-21st standards. Nine SGA clinical phenotypes were identified using a predefined conceptual framework. All delivery and perinatal outcomes analyzed were significantly different among the nine phenotypes. The whole SGA cohort had a three-times higher risk of perinatal mortality compared with non-SGA fetuses (1.4% vs 0.4%; P < 0.001). SGA clinical phenotypes exhibited three patterns of perinatal mortality risk: the highest risk was associated with congenital anomaly (8.3%; OR, 17.17 (95% CI, 2.17-136.12)) and second- or third-trimester hemorrhage (8.3%; OR, 9.94 (95% CI, 1.23-80.02)) clusters; medium risk was associated with gestational diabetes (3.8%; OR, 9.59 (95% CI, 1.27-72.57)), preterm birth (3.2%; OR, 4.65 (95% CI, 0.62-35.01)) and intrauterine growth restriction (3.1%; OR, 5.93 (95% CI, 3.21-10.95)) clusters; and the lowest risk was associated with the remaining clusters. Perinatal mortality rate did not differ between SGA fetuses without other clinical conditions (54.1% of SGA fetuses) and appropriate-for-gestational-age fetuses (0.1% vs 0.4%; OR, 0.41 (95% CI, 0.06-2.94); P = 0.27). SGA combined with other obstetric pathologies increased significantly the risk of perinatal mortality, as demonstrated by the increased odds of perinatal death in SGA cases with gestational diabetes compared to non-SGA cases with the same condition (OR, 24.40 (95% CI, 1.31-453.91)). CONCLUSIONS: We identified nine SGA clinical phenotypes associated with different patterns of risk for adverse perinatal outcome. Our findings suggest that considering clinical characteristics in addition to ultrasound findings could improve risk stratification and decision-making for management of SGA fetuses. Future clinical trials investigating management of fetuses with SGA should take into account clinical information in addition to Doppler parameters and estimated fetal weight. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Subject(s)
Fetal Growth Retardation , Premature Birth , Female , Fetal Growth Retardation/diagnostic imaging , Fetus , Humans , Infant, Newborn , Infant, Small for Gestational Age , Phenotype , Placenta , Pregnancy , Risk Assessment
3.
Nat Commun ; 12(1): 2660, 2021 May 11.
Article in English | MEDLINE | ID: mdl-33976209

ABSTRACT

The implementation of nano-engineered composite oxides opens up the way towards the development of a novel class of functional materials with enhanced electrochemical properties. Here we report on the realization of vertically aligned nanocomposites of lanthanum strontium manganite and doped ceria with straight applicability as functional layers in high-temperature energy conversion devices. By a detailed analysis using complementary state-of-the-art techniques, which include atom-probe tomography combined with oxygen isotopic exchange, we assess the local structural and electrochemical functionalities and we allow direct observation of local fast oxygen diffusion pathways. The resulting ordered mesostructure, which is characterized by a coherent, dense array of vertical interfaces, shows high electrochemically activity and suppressed dopant segregation. The latter is ascribed to spontaneous cationic intermixing enabling lattice stabilization, according to density functional theory calculations. This work highlights the relevance of local disorder and long-range arrangements for functional oxides nano-engineering and introduces an advanced method for the local analysis of mass transport phenomena.

4.
J Med Syst ; 45(3): 30, 2021 Jan 28.
Article in English | MEDLINE | ID: mdl-33511485

ABSTRACT

The aim of this study was to evaluate the performance of a tablet-based, digitized structured self-assessment (DSSA) of patient anamnesis (PA) prior to computed tomography (CT). Of the 317 patients consecutively referred for CT, the majority (n = 294) was able to complete the tablet-based questionnaire, which consisted of 67 items covering social anamnesis, lifestyle factors (e.g., tobacco abuse), medical history (e.g., kidney diseases), current symptoms, and the usability of the system. Patients were able to mark unclear questions for a subsequent discussion with the radiologist. Critical issues for the CT examination were structured and automatically highlighted as "red flags" (RFs) in order to improve patient interaction. RFs and marked questions were highly prevalent (69.5% and 26%). Missing creatinine values (33.3%), kidney diseases (14.4%), thyroid diseases (10.6%), metformin (5.5%), claustrophobia (4.1%), allergic reactions to contrast agents (2.4%), and pathological TSH values (2.0%) were highlighted most frequently as RFs. Patient feedback regarding the comprehensibility of the questionnaire and the tablet usability was mainly positive (90.9%; 86.2%). With advanced age, however, patients provided more negative feedback for both (p = 0.007; p = 0.039). The time effort was less than 20 min for 85.1% of patients, and faster patients were significantly younger (p = 0.046). Overall, the DSSA of PA prior to CT shows a high success rate and is well accepted by most patients. RFs and marked questions were common and helped to focus patients' interactions and reporting towards decisive aspects.


Subject(s)
Self-Assessment , Tomography, X-Ray Computed , Feedback , Humans , Surveys and Questionnaires
5.
J Matern Fetal Neonatal Med ; 33(3): 421-426, 2020 Feb.
Article in English | MEDLINE | ID: mdl-29950156

ABSTRACT

Objective: To validate an objective scoring system for middle cerebral artery (MCA) pulsed wave Doppler images.Method: From an image database of routine 36-week scans, a random sample of MCA Doppler images was selected. Two reviewers rated the images subjectively as acceptable or unacceptable. Subsequently they used an objective 6-point image scoring system and awarded one point for each of the following: (1) anatomical site, (2) magnification, (3) angle of insonation, (4) image clarity, (5) sweep speed adjustment, and (6) velocity scale and baseline adjustment. Image scores 4-6 were defined as good quality whereas 0-3 as poor. The subjective and objective agreement between the two reviewers was compared using the adjusted Kappa statistic.Results: A total of 124 images were assessed. Using objective scoring the agreement rate between reviewers increased to 91.9% (κ = 0.839) compared to subjective agreement 75.8% (κ = 0.516). The agreement for each criterion was: anatomical site 91.1% (κ = 0.823), magnification 95.2% (κ = 0.903), clarity 83.9% (κ = 0.677), angle 96.0% (κ = 0.919), sweep speed 98.4% (κ = 0.968), and velocity scale and baseline 94.4% (κ = 0.887).Conclusion: Objective assessment of MCA Doppler images using a 6-point scoring system has greater interobserver agreement than subjective assessment and could be used for MCA Doppler quality assurance.


Subject(s)
Middle Cerebral Artery/diagnostic imaging , Ultrasonography, Prenatal/standards , Female , Humans , Pregnancy , Ultrasonography, Doppler
6.
J Med Case Rep ; 13(1): 82, 2019 Mar 23.
Article in English | MEDLINE | ID: mdl-30902067

ABSTRACT

BACKGROUND: Mixed adenoneuroendocrine carcinomas are highly malignant tumors with both adenocarcinomatous and neuroendocrine components. They can originate in any organ but are more common in the rectum. Due to their rarity, current treatment recommendations for mixed adenoneuroendocrine carcinoma are based on limited data and follow general guidelines for the management of adenocarcinomas and neuroendocrine neoplasms. Uncertainty regarding the efficacy of the available local and systemic treatment strategies is a compounding issue. Even those patients with locally limited disease have a relatively short life expectancy. In this report, we describe a case of deep rectal mixed adenoneuroendocrine carcinoma with long survival after chemoradiation. CASE PRESENTATION: A 48-year-old Caucasian woman was diagnosed with a grade 3 rectal adenocarcinoma combined with a poorly differentiated large cell neuroendocrine carcinoma component and synchronous metastases (cT3cN1cM1) in both lobes of the liver in 2012. She received concomitant chemoradiotherapy followed by four additional cycles of cisplatin plus irinotecan. Initial treatment induced complete remission of the rectal tumor and liver metastases. Consequently, it was not necessary to surgically resect the primary tumor or any of the metastases. Three months after the end of treatment, one metastasis in the first segment of the liver showed regrowth, and stereotactic body radiotherapy of the metastasis and chemotherapy resulted in a clinical complete response. The patient has been recurrence-free for more than 5 years. CONCLUSIONS: Extended long-term control of a poorly differentiated metastatic (stage IV) mixed adenoneuroendocrine carcinoma is rare. The multimodal first- and second-line regimens of radiotherapy and chemotherapy described in this case report represent a new therapeutic approach. Encouraged by the results in this case, we compiled a review of the literature on mixed adenoneuroendocrine carcinoma.


Subject(s)
Adenocarcinoma/therapy , Carcinoma, Neuroendocrine/therapy , Chemoradiotherapy , Liver Neoplasms/secondary , Rectal Neoplasms/therapy , Adenocarcinoma/diagnostic imaging , Adenocarcinoma/pathology , Antineoplastic Agents/therapeutic use , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Carcinoma, Neuroendocrine/diagnostic imaging , Carcinoma, Neuroendocrine/pathology , Cisplatin/therapeutic use , Female , Humans , Irinotecan/therapeutic use , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Liver Neoplasms/therapy , Magnetic Resonance Imaging , Middle Aged , Neoplasm Staging , Rectal Neoplasms/diagnostic imaging , Rectal Neoplasms/pathology , Remission Induction , Tomography, X-Ray Computed , Topoisomerase I Inhibitors/therapeutic use
7.
Ultrasound Obstet Gynecol ; 53(2): 251-255, 2019 02.
Article in English | MEDLINE | ID: mdl-29808615

ABSTRACT

OBJECTIVES: To develop an objective image-scoring system for pulsed-wave Doppler measurement of maternal uterine and fetal umbilical arteries, and evaluate how this compares with subjective assessment. METHODS: As an extension to the INTERGROWTH-21st Project, we developed a scoring system based on six predefined criteria for uterine and umbilical artery pulsed-wave Doppler measurements. Objective evaluation using the scoring system was compared with subjective assessment which consisted of classifying an image as simply acceptable or unacceptable. Based on sample size estimation, a total of 120 umbilical and uterine artery Doppler images were selected randomly from the INTERGROWTH-21st image database. Two independent reviewers evaluated all images in a blinded fashion, both subjectively and using the six-point scoring system. Percentage agreement and kappa statistic were compared between the two methods. RESULTS: The overall agreement between reviewers was higher for objective assessment using the scoring system (agreement, 85%; adjusted kappa, 0.70) than for subjective assessment (agreement, 70%; adjusted kappa, 0.47). For the six components of the scoring system, the level of agreement (adjusted kappa) was 0.97 for anatomical site, 0.88 for sweep speed, 0.77 for magnification, 0.68 for velocity scale, 0.68 for image clarity and 0.65 for angle of insonation. CONCLUSION: In quality assessment of umbilical and uterine artery pulsed-wave Doppler measurements, our proposed objective six-point image-scoring system is associated with greater reproducibility than is subjective assessment. We recommend this as the preferred method for quality control, auditing and teaching. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Subject(s)
Ultrasonography, Doppler, Pulsed/standards , Ultrasonography, Prenatal/standards , Female , Humans , Pregnancy , Prospective Studies , Quality Control , Reproducibility of Results , Umbilical Arteries/blood supply , Umbilical Arteries/diagnostic imaging , Uterine Artery/diagnostic imaging
8.
Ultrasound Obstet Gynecol ; 54(5): 650-654, 2019 Nov.
Article in English | MEDLINE | ID: mdl-30478919

ABSTRACT

OBJECTIVE: To evaluate whether an automated tool can recognize a structure of interest and measure fetal head circumference (HC), abdominal circumference (AC) and femur length (FL) on frozen two-dimensional ultrasound images. METHODS: Ultrasound examinations were performed in 100 singleton pregnancies between 20 and 40 weeks of gestation, ensuring an even distribution throughout gestational age. In each pregnancy, three standard biometric variables (HC, AC, FL) were measured each in three different images obtained for this purpose (i.e. nine independent image acquisitions). An algorithm (Philips Research) was used to detect the structure of interest and automatically place calipers for measurement. Caliper placement was assessed in two ways. First, subjective clinical assessment was performed to determine whether the caliper placement was correct, and caliper position was classified as 'acceptable for clinical use', 'minor adjustment required' or 'major adjustment required'. Second, the resulting automatic measurements were compared with manual measurements, taken in real time. Mean difference errors were calculated and expressed as percentages to correct for fetal growth with advancing gestation. RESULTS: After exclusion of one pregnancy due to missing images, a total of 891 images (297 for each biometric variable) from 99 pregnancies were analyzed. The algorithm failed to place calipers for the AC in nine images, whereas there were no failures in caliper placement for measurement of HC and FL. On subjective quality assessment of automatic caliper placement, in 475 (53.3%) images position of the calipers was judged to be clinically acceptable and did not require any adjustment, while in 317 (35.6%) and 90 images (10.1%) minor and major adjustments were required, respectively. The mean error between manual and automatic measurement of HC was -0.21 cm corresponding to a percentage error of -0.81% with 95% limits of agreement (LOA) between -3.73% and 2.12%. For AC and FL measurements, the mean error was, respectively, 0.72 cm (percentage error, 2.40%) with LOA between -9.48% and 14.27%, and 0.21 cm (percentage error, 3.76%) with LOA between -8.38% and 15.91%. CONCLUSIONS: The automated tool identified correctly the biometric variable of interest in 99% of frozen images. The resulting measurements had a high degree of accuracy and compared well with previously published manual-to-manual agreement. The measurements exhibited bias, with the automated tool underestimating biometry; this could be overcome by further improvements in the algorithm. Nevertheless, adjustable calipers for manual correction remains a requirement. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Subject(s)
Biometry/instrumentation , Fetal Development , Fetus/diagnostic imaging , Adolescent , Adult , Algorithms , Automation , Female , Femur/diagnostic imaging , Femur/embryology , Gestational Age , Head/diagnostic imaging , Head/embryology , Humans , Pregnancy , Ultrasonography, Prenatal/methods , Waist Circumference , Young Adult
9.
Ultrasound Obstet Gynecol ; 52(1): 66-71, 2018 07.
Article in English | MEDLINE | ID: mdl-28600829

ABSTRACT

OBJECTIVE: Although no clear evidence exists, many international guidelines advocate early-term delivery of small-for-gestational-age (SGA) fetuses. The aim of this study was to determine whether a risk-stratification protocol in which low-risk SGA fetuses are managed expectantly beyond 37 weeks affects perinatal and maternal outcomes. METHODS: This was an impact study examining data collected over a 39-month period (1 January 2013 to 30 April 2016) at a tertiary referral unit. The study included women who were referred to the fetal medicine unit with a singleton non-anomalous fetus diagnosed antenatally as SGA (estimated fetal weight < 10th centile) from 36 + 0 weeks' gestation. In 2014, a protocol for management of SGA was introduced, which included risk stratification with surveillance and expectant management after 37 weeks for lower-risk babies (protocol group). This was compared with the previous strategy, which recommended delivery at around 37 weeks (pre-protocol group). Primary outcome was neonatal composite adverse outcome. RESULTS: In the pre-protocol group, there were 138 SGA babies; in the protocol group there were 143. Mean gestational ages at delivery were 37.4 weeks in the pre-protocol group and 38.2 weeks in the protocol group (P = 0.04). The incidence of neonatal composite adverse outcome was lower in the protocol group (9% vs 22%; P < 0.01), as was neonatal unit admission (13% vs 39%; P < 0.01). Induction of labor and Cesarean section rates were lower, and vaginal delivery rate (83% vs 60%; P < 0.01) was higher, in the protocol group. Most of the differences were as a result of delayed delivery of SGA babies that were stratified as low risk. CONCLUSIONS: The findings of this study suggest that protocol-based management of SGA babies may improve outcome, and that identification of moderate SGA should not in isolation prompt delivery. Larger numbers are required to assess any impact on perinatal mortality. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Subject(s)
Cesarean Section/statistics & numerical data , Delivery, Obstetric/statistics & numerical data , Fetal Growth Retardation/diagnostic imaging , Fetal Weight/physiology , Adult , Clinical Protocols , Female , Fetal Growth Retardation/physiopathology , Gestational Age , Humans , Infant, Newborn , Infant, Small for Gestational Age , Pregnancy , Pregnancy Outcome , Pregnancy Trimester, Third , Retrospective Studies , Risk Assessment , Time Factors
10.
Clin Neuroradiol ; 28(3): 367-376, 2018 Sep.
Article in English | MEDLINE | ID: mdl-28265679

ABSTRACT

PURPOSE: To evaluate the performance of an innovative image processing approach for detection of T2-weighted hyperintense multiple sclerosis (MS) lesions. METHODS: In this study 20 consecutive patients with inflammatory demyelinating lesions were retrospectively evaluated of whom 10 patients featured progressive disease and 10 a stable lesion load. 3 mm transversal FLAIRfusion imaging was processed and archived. Image processing was performed through landmark-based 3D co-registration of the previous and current isotropic FLAIR examination followed by inversion of image contrast. Thereby, the hyperintense signals of the unchanged MS plaques extinguish each other, while newly developed lesions appear bright on FLAIRfusion. Diagnostic performance was evaluated by 4 experienced readers. Consensus reading supplied the reference standard. Sensitivity, specificity, NPV (negative predictive value), PPV (positive predictive value), interreader agreement and reading time were the outcome measures analyzed. RESULTS: Combined sensitivity was 100% at a specificity of 88.2%, with PPV ranging from 83.3% to 90.1% and NPV at 100%. Reading time was nearly 5­fold faster than conventional side by side comparison (35.6 s vs. 163.7 s, p < 0.001). Cohen's kappa was excellent (>0.75; p < 0.001) and Cronbach's alpha was 0.994. CONCLUSION: FLAIRfusion provides reliable detection of newly developed MS lesions along with strong interreader agreement across all levels of expertise in 35 s of reading time.


Subject(s)
Brain/diagnostic imaging , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Multiple Sclerosis/diagnostic imaging , Adult , Female , Germany , Humans , Male , Middle Aged , Reading , Retrospective Studies , Sensitivity and Specificity , Young Adult
11.
Ultrasound Obstet Gynecol ; 52(4): 494-500, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29266519

ABSTRACT

OBJECTIVE: To investigate whether abdominal circumference growth velocity (ACGV) improves the prediction of perinatal outcome in small-for-gestational-age (SGA) fetuses beyond that afforded by estimated fetal weight (EFW) and cerebroplacental ratio (CPR). METHODS: A cohort of 235 singleton SGA fetuses at 36-38 weeks' gestation was examined. ACGV, EFW and CPR centiles were calculated. ACGV centile was determined using data from a large database of 19-21- and 36-38-week scans in an unselected population. Binary variables of ACGV < 10th , EFW < 3rd and CPR < 5th centiles were defined as abnormal. Two composite adverse outcomes (CAO) were explored: CAO-1 defined as at least one of umbilical artery pH < 7.10, 5-min Apgar score < 7 or neonatal unit admission, and CAO-2 that included in addition hypoglycemia, intrapartum fetal distress and perinatal death. Univariate and multivariate logistic regression analyses were performed to analyze the relationship between the three risk factors and their predictive value for CAO. The change in screening performance afforded by adding ACGV to EFW and CPR was assessed and receiver-operating characteristics (ROC) curves were calculated. RESULTS: ACGV < 10th centile was an independent risk factor for CAO. The sensitivity, specificity, positive and negative likelihood ratios of a predictive model based on EFW < 3rd centile and CPR < 5th centile were, respectively, 51%, 70%, 1.71 and 0.69 for CAO-1 and 41%, 70%, 1.39 and 0.83 for CAO-2. After addition of ACGV < 10th centile to the model, the respective values were 82%, 46%, 1.54 and 0.38 for CAO-1 and 71%, 47%, 1.34 and 0.62 for CAO-2. Using continuous variables, the areas under the ROC curves improved marginally from 0.669 (95% CI, 0.604-0.729) to 0.741 (95% CI, 0.677-0.798) for CAO-1 and from 0.646 (95% CI, 0.580-0.707) to 0.700 (95% CI, 0.633-0.759) for CAO-2 after addition of ACGV to the model. CONCLUSIONS: ACGV is a risk factor for adverse neonatal outcome that is independent of EFW and of CPR, although any improvement in the prediction of adverse outcome is not statistically significant. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Subject(s)
Abdomen/diagnostic imaging , Fetal Development/physiology , Fetal Growth Retardation/physiopathology , Infant, Small for Gestational Age/growth & development , Ultrasonography, Prenatal , Abdomen/embryology , Biometry , Female , Fetal Growth Retardation/diagnostic imaging , Gestational Age , Humans , Infant, Newborn , Pregnancy , Pregnancy Outcome , Prospective Studies , Stillbirth
12.
Ultrasound Obstet Gynecol ; 52(3): 332-339, 2018 Sep.
Article in English | MEDLINE | ID: mdl-28718938

ABSTRACT

OBJECTIVE: To assess a comprehensive package of ultrasound quality control in the Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project, a large multicenter study of fetal growth. METHODS: Quality control (QC) measures were performed for 20 313 ultrasound scan images obtained prospectively from 4321 fetuses at 14-41 weeks' gestation in eight geographical locations. At the time of each ultrasound examination, three fetal biometric variables (head circumference (HC), abdominal circumference (AC) and femur length (FL)) were measured in triplicate on separately generated images. All measurements were taken in a blinded fashion. QC had two elements: (1) qualitative QC: visual assessment by sonographers at each study site of their images based on specific criteria, with 10% of images being re-assessed at the Oxford-based Ultrasound Quality Unit (compared using an adjusted kappa statistic); and (2) quantitative QC: assessment of measurement data by comparing the first, second and third measurements (intraobserver variability), remeasurement of caliper replacement in 10% (interobserver variability), both by Bland-Altman plots and plotting frequency histograms of the SD of triplicate measurements and assessing how many were above or below 2 SD of the expected distribution. The system allowed the sonographers' performances to be monitored regularly. RESULTS: A high level of agreement between self- and external scoring was demonstrated for all measurements (κ = 0.99 (95% CI, 0.98-0.99) for HC, 0.98 (95% CI, 0.97-0.99) for AC and 0.96 (95% CI, 0.95-0.98) for FL). Intraobserver 95% limits of agreement (LoA) of ultrasound measures for HC, AC and FL were ± 3.3%, ± 5.6% and ± 6.2%, respectively; the corresponding values for interobserver LoA were ± 4.4%, ± 6.0% and ± 5.6%. The SD distribution of triplicate measurements for all biometric variables showed excessive variability for three of 31 sonographers, allowing prompt identification and retraining. CONCLUSIONS: Qualitative and quantitative QC monitoring was feasible and highly reproducible in a large multicenter research study, which facilitated the production of high-quality ultrasound images. We recommend that the QC system we developed is implemented in future research studies and clinical practice. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Subject(s)
Fetal Development , Observer Variation , Quality Control , Ultrasonography, Prenatal/standards , Abdomen/diagnostic imaging , Abdomen/embryology , Biometry/methods , Feasibility Studies , Female , Femur/diagnostic imaging , Femur/embryology , Head/diagnostic imaging , Head/embryology , Humans , Population Surveillance , Pregnancy , Prospective Studies , Waist Circumference
13.
Z Rheumatol ; 76(7): 580-588, 2017 Sep.
Article in German | MEDLINE | ID: mdl-28681117

ABSTRACT

BACKGROUND: Non-invasive imaging modalities are used for the morphological and functional evaluation and diagnosis of gout; however, none of these methods are sufficiently sensitive or specific for the diagnosis of gout. By the use of dual-energy computed tomography (DECT) the direct visualization of sodium urate deposition is now possible. Moreover, it is possible to show the different pathological situations, disease activity and monitoring of tophaceous gout. The positive DECT scan became one of the 2015 ACR/EULAR classification criteria for gout 2 years ago. MATERIAL AND METHODS: The literature search from 2009-2017 in PubMed, with the search criteria "Dual Energy CT and Gout" revealed 77 publications on the DECT method. RESULTS: The DECT technique has a high sensitivity (90-100%) and a high specificity (83-89%) for diagnosing gout. The development of a semiquantitative scoring method also enables measurement of the severity of urate deposits at specific sites. CONCUSION: The gold standard for the diagnosis of gout is still the detection of monosodium urate monohydrate crystals by polarizing microscopy after a joint punction; however with the DECT it is possible to non-invasively visualize, measure and score urate deposition and is therefore suitable for estimating the severity and prognosis. Although not clinical validated, DECT may sometimes help to detect gout. More studies should be conducted.


Subject(s)
Gout/diagnostic imaging , Tomography, X-Ray Computed/methods , Crystallization , Follow-Up Studies , Gout/classification , Gout/therapy , Humans , Joints/diagnostic imaging , Prognosis , Uric Acid
14.
Clin Ter ; 168(3): e194-e198, 2017.
Article in English | MEDLINE | ID: mdl-28612896

ABSTRACT

BACKGROUND: Redo surgery for recurrent goiter is still now, even in experienced hands, followed by higher morbidity than primary total thyroidectomy. Suppressive Levothyroxine therapy failed to improve the recurrence rate, while inducing a subclinical hyperthyroidism. Aim of this study is to verify morbidity after total thyroidectomy for benign thyroid diseases, both primary and after recurrence. MATERIALS AND METHODS: A series of 20 cases of total thyroidectomy for recurrent benign diseases (RG), performed between January 2001 and December 2013 was compared with 225 cases of primary total thyroidectomy (PT) . Cancers, even incidentally diagnosed, were excluded. At least a 12 months follow up was accomplished. Due to the small size of the sample for RG, statistical analysis was performed by Fisher test only. RESULTS: Postoperative complications were Transient hypocalcemia: 5 (25%) in RG and 18 (8%) in PT, Permanent hypocalcemia only 2 (10%) in RG (significant for p <0,05), Transient RLN deficit 5 (25 %) in RG and 6 (2.6%) in PT (significant for p< 0.05). CONCLUSIONS: Differences in incidence of perioperative complications cannot be advocated to justify a less than total thyroidectomy even in benign disease setting. The need for a redo surgery with its burden of morbidity is per se a good reason to avoid a conservative surgery. Further, suppressive therapy with Levothyroxine often fails to avoid recurrence, inducing in some cases a specific morbidity. Our experience confirms the results of our previous experiences and of literature on this topic: the best management of recurrent goiter is its prevention by primary total thyroidectomy.


Subject(s)
Goiter/surgery , Thyroid Diseases/surgery , Thyroidectomy , Aged , Aged, 80 and over , Female , Goiter/epidemiology , Humans , Hyperthyroidism/complications , Incidence , Male , Morbidity , Postoperative Complications/epidemiology , Recurrence , Reoperation , Retrospective Studies , Thyroid Diseases/complications , Thyroidectomy/methods
15.
Eur Rev Med Pharmacol Sci ; 20(24): 5242-5248, 2016 12.
Article in English | MEDLINE | ID: mdl-28051242

ABSTRACT

OBJECTIVE: To evaluate the oncologic safety of colonic self-expandable metal stents (SEMS) in obstructive colon cancer. PATIENTS AND METHODS: We retrospectively reviewed all the patients who were treated with endoscopic placement of a self-expandable metallic stent (SEMS) at our institution. RESULTS: A total of 26 patients were identified during the study period, of which 24 patients (92.30%) were treated with SEMS as a bridge-to-surgery and 2 (7.69%) as palliation. In 22 cases (80.76%), the stenosis was localized to the left side. Clinical success with resolution of bowel obstructions was achieved in 22 (84.61%) patients within a short period of time. Among patients treated successfully with SEMS insertion as bridge to surgery (n = 22), 20 (90.9%) underwent one-stage surgery with primary anastomosis while 2 patients (9.09%) underwent colostomy due to intraoperative evidence of a covered perforation by cancer tissue in the pelvis. Patients with subclinical perforation developed an early peritoneal carcinomatosis, 10 patients treated with curative intent subsequently developed liver metastasis after 24 months. CONCLUSIONS: We reported an overall poor outcome among patients treated with the insertion of SEMS. This led us to think that, in some cases, occlusion may be better than a "silent" perforation.


Subject(s)
Colonic Neoplasms/surgery , Intestinal Obstruction/surgery , Stents , Humans , Metals , Pilot Projects , Retrospective Studies , Treatment Outcome
16.
J Mater Chem B ; 4(11): 2051-2058, 2016 Mar 21.
Article in English | MEDLINE | ID: mdl-32263082

ABSTRACT

In this study, the antibacterial efficacy of NO-releasing porous silicon nanoparticles (pSiNPs) is reported. NO-releasing pSiNPs were produced via the conjugation of S-nitrosothiol (SNO) and S-nitrosoglutathione (GSNO) donors to the nanoparticle surfaces. The release of the conjugated NO caused by the decomposition of the conjugated SNO and GSNO was boosted in the presence of ascorbic acid. The released NO was bactericidal to Gram-positive (Staphylococcus aureus) and Gram-negative bacteria (Escherichia coli), and eliminated bacterial growth within 2 h of incubation without compromising the viability of mammalian cells. These results demonstrate the advantages of NO-releasing pSiNPs for antibacterial applications, for example, in chronic wound treatment.

17.
Chem Commun (Camb) ; 51(20): 4279-82, 2015 Mar 11.
Article in English | MEDLINE | ID: mdl-25673366

ABSTRACT

Poly(2-oxazoline)s are emerging revolutionary biomaterials, exhibiting comparable and even superior properties to well-established counterparts. Overcoming current tedious wet synthesis methods, we report solvent-free and substrate independent, plasma polymerised nanoscale biocompatible polyoxazoline coatings capable of controlling protein and cell adhesion, and significantly reducing biofilm build up.


Subject(s)
Biocompatible Materials/chemistry , Oxazoles/chemistry , Biocompatible Materials/pharmacology , Cell Adhesion , Cell Survival , Cells, Cultured , Fibroblasts/drug effects , Fibroblasts/metabolism , Humans , Interleukin-6/metabolism , Macrophages/drug effects , Oxazoles/pharmacology , Polyamines/chemistry , Polymerization , Serum Albumin, Bovine/chemistry , Tumor Necrosis Factor-alpha/metabolism
18.
Chem Commun (Camb) ; 51(10): 1838-41, 2015 Feb 04.
Article in English | MEDLINE | ID: mdl-25522209

ABSTRACT

Herein, we report a novel and solvent-free technique for the encapsulation of pharmaceuticals that allows achieving controllable release rates. This method utilizes the deposition of a plasma polymer coating of controlled chemistry and thickness on the outer surface of drug particles placed under continuous agitation.


Subject(s)
Capsules/chemistry , Delayed-Action Preparations , Drug Compounding/methods , Ampicillin/chemistry , Microbial Sensitivity Tests , Molecular Structure , Polymers/chemistry , Solvents/chemistry , Surface Properties
19.
J Mater Chem B ; 3(21): 4325-4329, 2015 Jun 07.
Article in English | MEDLINE | ID: mdl-32262774

ABSTRACT

In this report, we employed surface-initiated atom transfer radical polymerisation to graft thermo-responsive copolymers of oligo(ethylene glycol) methacrylates from the surface of diatom biosilica microcapsules. We demonstrate the application of the resulting composites for thermo-responsive drug delivery.

20.
Eur Rev Med Pharmacol Sci ; 18(2 Suppl): 24-7, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25535187

ABSTRACT

INTRODUCTION: Pseudocyst formation commonly follows pancreatitis, but erosion into the spleen is rare and potentially life threatening. We report a case of an intrasplenic pancreatic pseudocyst treated laparoscopically with distal pancreatectomy and splenectomy. METHODS: A 50 year old male with a history of chronic alcoholic pancreatitis, presented with abdominal pain for 3 months, worsening over the past several days. A CT scan showed a broad 9 cm subcapsular fluid collection suspicious for an intra-splenic pseudocyst. The patient underwent laparoscopic distal pancreatectomy and splenectomy. RESULTS: There were no intraoperative complications and the patient was discharged on day 8. The final pathology revealed a benign cystic lesion measuring 9 x 6 x 3 cm that was not communicating with the pancreatic duct, and 2 smaller pseudocysts in the pancreatic body and tail. A previous scan did not reveal any abnormalities in the spleen, and showed the other pancreatic pseudocysts. At 8 month follow up the patients was symptom free, with no new pseudocysts. CONCLUSIONS: Splenic parenchyma involvement is an unusual complication of pancreatic pseudocyst. The optimal treatment is controversial. Percutaneous drainage carries a high recurrence rate and risk of hemorrhage. Open surgery is effective, but associated with significant morbidity. Laparoscopy offers an effective method of treatment without the potential complication of a large abdominal incision.


Subject(s)
Pancreatic Pseudocyst/surgery , Splenic Diseases/surgery , Drainage/methods , Humans , Laparoscopy/methods , Male , Middle Aged , Pancreatectomy/methods , Pancreatic Pseudocyst/pathology , Pancreatitis, Alcoholic/pathology , Splenectomy/methods , Splenic Diseases/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...