1.
Int J Radiat Oncol Biol Phys ; 111(4): 1011-1022, 2021 11 15.
Article in English | MEDLINE | ID: mdl-34343608

ABSTRACT

PURPOSE: To establish and investigate the effects of dose, linear energy transfer (LET), and O2 concentration on biologic response to ultrahigh dose rate (uHDR; FLASH) helium ion beams compared with standard dose rate (SDR) irradiation. METHODS AND MATERIALS: Beam delivery settings for raster-scanned helium ions at both uHDR and SDR were tuned to achieve >100 Gy/s and ∼0.1 Gy/s, respectively. For both SDR and uHDR, plan optimization and calibration for 10 × 10-mm2 fields were performed to assess in vitro response at an LET range of 4.5 to 16 keV/µm. Clonogenic survival assay was conducted at doses ranging from 2 to 12 Gy in 2 human lung epithelial cell lines (A549 and H1437). Radiation-induced nuclear γH2AX foci (RIF) were assessed in both epithelial cell lines and primary human pulmonary fibroblasts. RESULTS: Average dose rates achieved were 185 Gy/s and 0.12 Gy/s for uHDR and SDR, respectively. No differences in cellular response to SDR versus uHDR were observed for all tested doses at 21% O2, and at 2 and 4 Gy at 1% O2. In contrast, at 1% O2 and a dose threshold of ≳8 Gy cell survival was higher and correlated with reduced nuclear γH2AX RIF signal, indicating FLASH sparing effect in the investigated cell lines irradiated with uHDR compared with SDR. CONCLUSIONS: The first uHDR delivery of raster-scanned particle beams was achieved using helium ions, reaching FLASH-level dose-rates of >100 Gy/s. Baseline oxygen levels and delivered dose (≳8 Gy) play a pivotal role, irrespective of the studied cell lines, for observation of a sparing effect for helium ions.


Subject(s)
Helium , Linear Energy Transfer , Cell Line, Tumor , Cell Survival , Humans , Ions , Oxygen
2.
Rev Sci Instrum ; 85(2): 02A951, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24593530

ABSTRACT

The clinical operation at the Heidelberg Ion Beam Therapy Center (HIT) started in November 2009; since then more than 1600 patients have been treated. In a 24/7 operation scheme two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce protons and carbon ions. The modification of the low energy beam transport line and the integration of a third ion source into the therapy facility will be shown. In the last year we implemented a new extraction system at all three sources to enhance the lifetime of extraction parts and reduce preventive and corrective maintenance. The new four-electrode-design provides electron suppression as well as lower beam emittance. Unwanted beam sputtering effects which typically lead to contamination of the insulator ceramics and subsequent high-voltage break-downs are minimized by the beam guidance of the new extraction system. By this measure the service interval can be increased significantly. As a side effect, the beam emittance can be reduced allowing a less challenging working point for the ion sources without reducing the effective beam performance. This paper gives also an outlook to further enhancements at the HIT ion source testbench.


Subject(s)
Cyclotrons/instrumentation , Radiotherapy/instrumentation , Maintenance , Time Factors