Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
2.
Eur J Cardiothorac Surg ; 54(3): 460-466, 2018 09 01.
Article in English | MEDLINE | ID: mdl-29514183

ABSTRACT

OBJECTIVES: Transapical off-pump NeoChord repair is a novel minimally invasive surgical procedure to treat degenerative mitral valve regurgitation. The aim was to evaluate 1-year clinical results of the NeoChord procedure in a consecutive cohort of patients. METHODS: Between February 2013 and July 2016, 213 patients were enrolled in the NeoChord Independent International Registry. All patients presented severe mitral regurgitation due to flail/prolapse of 1 or both leaflets, and they all completed postoperative echocardiographic assessment up to 1 year. We identified the primary end point as composed of procedural success, freedom from mortality, stroke, reintervention, recurrence of severe mitral regurgitation, rehospitalization and decrease of at least 1 New York Heart Association functional class at 1-year follow-up. We also compared outcomes according to the anatomical classification (Type A: isolated central posterior leaflet disease; Type B: posterior multisegment disease; Type C: anterior, bileaflet, paracommissural disease with/without leaflet/annular calcifications). RESULTS: The median age was 68 years (interquartile range 56-77), and the median EuroSCORE II was 1.05% (interquartile range 0.67-1.76). The number of Type A, B and C patients was 82 (38.5%), 98 (46%) and 33 (15.5%), respectively. Procedural success was achieved in 206 (96.7%) patients. At 1-year follow-up, overall survival was 98 ± 1%. Composite end point was achieved in 84 ± 2.5% for the overall population and 94 ± 2.6%, 82.6 ± 3.8% and 63.6 ± 8.4% in Type A, Type B and Type C patients, respectively (P < 0.0001). CONCLUSIONS: These results demonstrate that the NeoChord procedure is safe, effective and reproducible. Clinical and echocardiographic efficacy is maintained up to 1 year with significant differences among the anatomical groups. Specific anatomical selection criteria are necessary to achieve stable results.


Subject(s)
Coronary Artery Bypass, Off-Pump , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Aged , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Bypass, Off-Pump/methods , Coronary Artery Bypass, Off-Pump/statistics & numerical data , Echocardiography , Female , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis/statistics & numerical data , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/statistics & numerical data , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/epidemiology , Postoperative Complications , Registries , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...