Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 141
Filter
1.
Sci Rep ; 14(1): 12618, 2024 06 01.
Article in English | MEDLINE | ID: mdl-38824189

ABSTRACT

Vascularized composite allotransplantations are complex procedures with substantial functional impact on patients. Extended preservation of VCAs is of major importance in advancing this field. It would result in improved donor-recipient matching as well as the potential for ex vivo manipulation with gene and cell therapies. Moreover, it would make logistically feasible immune tolerance induction protocols through mixed chimerism. Supercooling techniques have shown promising results in multi-day liver preservation. It consists of reaching sub-zero temperatures while preventing ice formation within the graft by using various cryoprotective agents. By drastically decreasing the cell metabolism and need for oxygen and nutrients, supercooling allows extended preservation and recovery with lower ischemia-reperfusion injuries. This study is the first to demonstrate the supercooling of a large animal model of VCA. Porcine hindlimbs underwent 48 h of preservation at - 5 °C followed by recovery and normothermic machine perfusion assessment, with no issues in ice formation and favorable levels of injury markers. Our findings provide valuable preliminary results, suggesting a promising future for extended VCA preservation.


Subject(s)
Hindlimb , Organ Preservation , Animals , Swine , Organ Preservation/methods , Cryopreservation/methods , Reperfusion Injury , Cryoprotective Agents/pharmacology
2.
Transpl Int ; 37: 12338, 2024.
Article in English | MEDLINE | ID: mdl-38813393

ABSTRACT

The current gold standard for preserving vascularized composite allografts (VCA) is 4°C static cold storage (SCS), albeit muscle vulnerability to ischemia can be described as early as after 2 h of SCS. Alternatively, machine perfusion (MP) is growing in the world of organ preservation. Herein, we investigated the outcomes of oxygenated acellular subnormothermic machine perfusion (SNMP) for 24-h VCA preservation before allotransplantation in a swine model. Six partial hindlimbs were procured on adult pigs and preserved ex vivo for 24 h with either SNMP (n = 3) or SCS (n = 3) before heterotopic allotransplantation. Recipient animals received immunosuppression and were followed up for 14 days. Clinical monitoring was carried out twice daily, and graft biopsies and blood samples were regularly collected. Two blinded pathologists assessed skin and muscle samples. Overall survival was higher in the SNMP group. Early euthanasia of 2 animals in the SCS group was linked to significant graft degeneration. Analyses of the grafts showed massive muscle degeneration in the SCS group and a normal aspect in the SNMP group 2 weeks after allotransplantation. Therefore, this 24-h SNMP protocol using a modified Steen solution generated better clinical and histological outcomes in allotransplantation when compared to time-matched SCS.


Subject(s)
Graft Survival , Organ Preservation , Perfusion , Vascularized Composite Allotransplantation , Animals , Organ Preservation/methods , Perfusion/methods , Swine , Vascularized Composite Allotransplantation/methods , Hindlimb , Composite Tissue Allografts , Models, Animal , Transplantation, Homologous , Allografts
3.
Antioxidants (Basel) ; 13(5)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38790636

ABSTRACT

Vascularized composite allografts (VCA) face ischemic challenges due to their limited availability. Reperfusion following ischemia triggers oxidative stress and immune reactions, and scavenger molecules could mitigate ischemia-reperfusion injuries and, therefore, immune rejection. We compared two scavengers in a myocutaneous flap VCA model. In total, 18 myocutaneous flap transplants were performed in Major histocompatibility complex (MHC)-defined miniature swine. In the MATCH group (n = 9), donors and recipients had minor antigen mismatch, while the animals were fully mismatched in the MISMATCH group (n = 9). Grafts were pretreated with saline, sodium iodide (NaI), or hydrogen sulfide (H2S), stored at 4 °C for 3 h, and then transplanted. Flaps were monitored until clinical rejection without immunosuppression. In the MATCH group, flap survival did not significantly differ between the saline and hydrogen sulfide treatments (p = 0.483) but was reduced with the sodium iodide treatment (p = 0.007). In the MISMATCH group, survival was similar between the saline and hydrogen sulfide treatments (p = 0.483) but decreased with the sodium iodide treatment (p = 0.007). Rhabdomyolysis markers showed lower but non-significant levels in the experimental subgroups for both the MATCH and MISMATCH animals. This study provides insightful data for the field of antioxidant-based approaches in VCA and transplantation.

4.
Transplantation ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722685

ABSTRACT

BACKGROUND: Warm ischemia time (WIT) and ischemia-reperfusion injury are limiting factors for vascularized composite allograft (VCA) transplantation. Subnormothermic machine perfusion (SNMP) has demonstrated the potential to extend WIT in organ transplantation. This study evaluates the effect of SNMP on VCA viability after prolonged WIT. METHODS: Rat hindlimbs underwent WIT for 30, 45, 60, 120, 150, or 210 min, followed by 3-h SNMP. Monitoring of perfusion parameters and outflow determined the maximum WIT compatible with limb viability after SNMP. Thereafter, 2 groups were assessed: a control group with inbred transplantation (Txp) after 120 min of WIT and an experimental group that underwent WIT + SNMP + Txp. Graft appearance, blood gas, cytokine levels, and histology were assessed for 21 d. RESULTS: Based on potassium levels, the limit of WIT compatible with limb viability after SNMP is 120 min. Before this limit, SNMP reduces potassium and lactate levels of WIT grafts to the same level as fresh grafts. In vivo, the control group presented 80% graft necrosis, whereas the experimental group showed no necrosis, had better healing (P = 0.0004), and reduced histological muscle injury (P = 0.012). Results of blood analysis revealed lower lactate, potassium levels, and calcium levels (P = 0.048) in the experimental group. Both groups presented an increase in interleukin (IL)-10 and IL-1b/IL-1F2 with a return to baseline after 7 to 14 d. CONCLUSIONS: Our study establishes the limit of WIT compatible with VCA viability and demonstrates the effectiveness of SNMP in restoring a graft after WIT ex vivo and in vivo, locally and systemically.

5.
Bioengineering (Basel) ; 11(4)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38671744

ABSTRACT

Reconstructive techniques to repair severe tissue defects include the use of autologous fasciocutaneous flaps, which may be limited due to donor site availability or lead to complications such as donor site morbidity. A number of synthetic or natural dermal substitutes are in use clinically, but none have the architectural complexity needed to reconstruct deep tissue defects. The perfusion decellularization of fasciocutaneous flaps is an emerging technique that yields a scaffold with the necessary composition and vascular microarchitecture and serves as an alternative to autologous flaps. In this study, we show the perfusion decellularization of porcine fasciocutaneous flaps using sodium dodecyl sulfate (SDS) at three different concentrations, and identify that 0.2% SDS results in a decellularized flap that is efficiently cleared of its cellular material at 86%, has maintained its collagen and glycosaminoglycan content, and preserved its microvasculature architecture. We further demonstrate that the decellularized graft has the porous structure and growth factors that would facilitate repopulation with cells. Finally, we show the biocompatibility of the decellularized flap using human dermal fibroblasts, with cells migrating as deep as 150 µm into the tissue over a 7-day culture period. Overall, our results demonstrate the promise of decellularized porcine flaps as an interesting alternative for reconstructing complex soft tissue defects, circumventing the limitations of autologous skin flaps.

6.
J Surg Res ; 298: 137-148, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38603944

ABSTRACT

INTRODUCTION: Vascularized Composite Allografts (VCA) are usually performed in a full major histocompatibility complex mismatch setting, with a risk of acute rejection depending on factors such as the type of immunosuppression therapy and the quality of graft preservation. In this systematic review, we present the different immunosuppression protocols used in VCA and point out relationships between acute rejection rates and possible factors that might influence it. METHODS: This systematic review was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. We systematically searched Medline (PubMed), Embase, and The Cochrane Library between November 2022 and February 2023, using following Mesh Terms: Transplant, Transplantation, Hand, Face, Uterus, Penis, Abdominal Wall, Larynx, and Composite Tissue Allografts. All VCA case reports and reviews describing multiple case reports were included. RESULTS: We discovered 211 VCA cases reported. The preferred treatment was a combination of antithymocyte globulins, mycophenolate mofetil (MMF), tacrolimus, and steroids; and a combination of MMF, tacrolimus, and steroids for induction and maintenance treatment, respectively. Burn patients showed a higher acute rejection rate (P = 0.073) and were administered higher MMF doses (P = 0.020). CONCLUSIONS: In contrast to previous statements, the field of VCA is not rapidly evolving, as it has encountered challenges in addressing immune-related concerns. This is highlighted by the absence of a standardized immunosuppression regimen. Consequently, more substantial data are required to draw more conclusive results regarding the immunogenicity of VCAs and the potential superiority of one immunosuppressive treatment over another. Future efforts should be made to report the VCA surgeries comprehensively, and muti-institutional long-term prospective follow-up studies should be performed to compare the number of acute rejections with influencing factors.


Subject(s)
Composite Tissue Allografts , Graft Rejection , Immunosuppressive Agents , Vascularized Composite Allotransplantation , Humans , Graft Rejection/immunology , Graft Rejection/prevention & control , Composite Tissue Allografts/immunology , Composite Tissue Allografts/transplantation , Immunosuppressive Agents/therapeutic use , Vascularized Composite Allotransplantation/adverse effects , Vascularized Composite Allotransplantation/methods , Immunosuppression Therapy/methods , Immunosuppression Therapy/adverse effects , Acute Disease
7.
Heliyon ; 10(6): e26806, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38515684

ABSTRACT

Background: Thermography can be used in pre-operative planning of free perforator flap surgeries. Thermography assesses skin temperature by measuring the quantity of infrared radiation observed. In this meta-analysis, authors assess the sensitivity of smartphone-based thermal imaging (SBTI) in the detection of perforators and analyze the difference between static and dynamic imaging. Materials and methods: Authors followed the PRISMA guidelines for systematic reviews and meta-analyses. The meta package in R was used to conduct the meta-analysis. The "metaprop" function was used to calculate the overall sensitivity estimate and 95% confidence interval. The "metaprop.one" function was used to calculate subgroup estimates for static and dynamic study types. The "metareg" function was used to conduct meta-regression analyses to explore sources of heterogeneity. Results: This study includes seven articles with 1429 perforators being evaluated. The overall proportion of the sensitivities was estimated to be 0.8754 (95% CI: 0.7542; 0.9414) using a random effects model. The heterogeneity of the studies was high, as indicated by the tau^2 value of 1.2500 (95% CI: 0.4497; 8.4060) and the I^2 value of 92.6% (95% CI: 88.1%; 95.4%). The pooled sensitivity for static imaging was 0.8636 (95%CI: 0.6238-0.9603) with a tau^2 of 2.0661 and a tau of 1.4374, while the pooled sensitivity for dynamic imaging was slightly higher (p = 0.7016) at 0.8993 (95%CI: 0.7412-0.9653) with a smaller tau^2 of 0.8403 and a tau of 0.9167. Conclusion: Further studies need to confirm that SBTI is a reliable and convenient technique for detecting perforators for the pre-operative planning of free perforator flap surgeries.

8.
J Vis Exp ; (204)2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38465950

ABSTRACT

Burn wound healing is a complex and long process. Despite extensive experience, plastic surgeons and specialized teams in burn centers still face significant challenges. Among these challenges, the extent of the burned soft tissue can evolve in the early phase, creating a delicate balance between conservative treatments and necrosing tissue removal. Thermal burns are the most common type, and burn depth varies depending on multiple parameters, such as temperature and exposure time. Burn depth also varies in time, and the secondary aggravation of the "shadow zone" remains a poorly understood phenomenon. In response to these challenges, several innovative treatments have been studied, and more are in the early development phase. Nanoparticles in modern wound dressings and artificial skin are examples of these modern therapies still under evaluation. Taken together, both burn diagnosis and burn treatments need substantial advancements, and research teams need a reliable and relevant model to test new tools and therapies. Among animal models, swine are the most relevant because of their strong similarities in skin structure with humans. More specifically, Yucatan minipigs show interesting features such as melanin pigmentation and slow growth, allowing for studying high phototypes and long-term healing. This article aims to describe a reliable and reproducible protocol to study multi-depth burn wounds in Yucatan minipigs, enabling long-term follow-up and providing a relevant model for diagnosis and therapeutic studies.


Subject(s)
Skin , Wound Healing , Swine , Animals , Humans , Swine, Miniature , Wound Healing/physiology , Bandages , Disease Models, Animal
9.
J Burn Care Res ; 45(3): 601-607, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38401148

ABSTRACT

The treatment of postburn hypopigmentation was primarily surgical before the advent of new technologies. Medical devices and therapies are emerging to manage scar sequelae that can be disfiguring and associated with severe psychosocial impact. These innovations have been poorly investigated for hypopigmentation, but they represent a real hope. We reviewed all articles published on Pubmed up to June 2022. Included studies had to specifically focus on treating postburn hypopigmented scars. All articles evaluating transient solutions such as make-up, and articles describing inflammation-linked hypopigmentation with no etiological details or no burn injury history were excluded. Through this review, we have highlighted 6 different types of nonsurgical treatments reported in postburn leukoderma potentially allowing definitive results. Electrophoto-biomodulation or E light (combining intensive pulsed light, radiofrequency, and cooling), topical daylight psoralen UVA therapy, and lasers (fractional lasers using pulse energies or CO2FL devices, lasers-assisted drug delivery as local bimatoprost and tretinoin or pimecrolimus) have been explored with encouraging results in hypopigmented burns. Finally, other promising medical strategies include using FK506, a nonsteroidal anti-inflammatory drug, to induce melanogenesis or using melanocyte-stimulating hormones with fractional laser-assisted drug deliveries, which are expected to emerge soon.


Subject(s)
Burns , Hypopigmentation , Humans , Hypopigmentation/etiology , Hypopigmentation/therapy , Burns/complications , Burns/therapy , Laser Therapy , Cicatrix/therapy , Cicatrix/etiology , Phototherapy/methods
10.
Ann Transl Med ; 12(1): 15, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38304901

ABSTRACT

Background and Objective: Mastectomy is a primary treatment for breast cancer patients, and both autologous and implant-based reconstructive techniques have shown excellent results. In recent years, advancements in bioengineering have led to a proliferation of innovative approaches to breast reconstruction. This article comprehensively explores the promising perspectives offered by bioengineering and tissue engineering in the field of breast reconstruction. Methods: A literature review was conducted between April and June 2023 on PubMed and Google Scholar Databases. All English and French articles related to bioengineering applied to the field of breast reconstruction were included. We used the Evidence-Based Veterinary Medicine Association (EBVM) Toolkit 14 checklist for narrative reviews as a quality assurance measure and the Scale for the Assessment of Narrative Review Articles (SANRA) tool to self-assess our methodology. Key Content and Findings: Over 130 references related to breast bioengineering were included. The analysis revealed four key applications: enhancing the quality of the skin envelope, improving the viability of fat grafting, creating breast shape and volume via bio-printing, and optimizing nipple reconstruction through engineering techniques. The primary identified approaches revolved around establishing structural support and enhancing cellular viability. Structural techniques predominantly involved the implementation of 3D printed, decellularized, or biocompatible material scaffolds. Meanwhile, promoting cellular content trophicity primarily focused on harnessing the regenerative potential of adipose-derived stem cells (ADSCs) and increasing the tissue's survivability and cell trophicity. Conclusions: Tissue and bioengineering hold immense promise in the field of breast reconstruction, offering a diverse array of approaches. By combining existing techniques with novel advancements, they have the potential to significantly enhance the therapeutic options available to plastic and reconstructive surgeons.

11.
Int J Pharm ; 653: 123858, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38286196

ABSTRACT

Solid organ and vascularized composite allograft transplantation are pivotal in enhancing both life expectancy and quality of life. However, the significant risk of donor tissue rejection requires lifelong immunosuppressive therapy. Tacrolimus, a common component of immunosuppressive regimens, offers effectiveness in preventing organ rejection but poses challenges due to its narrow therapeutic window and toxicity, making it essential to carefully monitor its concentration. Tacrolimus trough levels are currently measured in blood, requiring frequent blood draws from patients, and results are available after 3 to 6 h. To address the need for a fast, minimally-invasive, and simple method to monitor tacrolimus concentrations, we have assessed a new device for at-home analysis, the Immunosuppressant Drug Monitor (IDM) that can extract, identify and quantify tacrolimus in saliva within 15 min. We included males and females hospitalized at Massachusetts General Hospital Transplant Unit, between the ages of 21 and 65 years, and treated with Tacrolimus. Informed consent, demographic and treatment data were collected. Each subject was asked to provide a 5 mL saliva sample that was de-identified and processed by the IDM, while a 5 mL blood sample was drawn and supplied to the MGH clinical lab for analysis by the current standard, immunoassays. The predicted tacrolimus concentration found in saliva was compared to the blood trough level results. 62 samples from 31 different patients were obtained. The male to female ratio and ethnicity distribution were well balanced. The majority of patients were within 30 days of initiating tacrolimus treatment. After IDM calibration and exclusion, 21 samples were measured by the IDM. Using an exponential function fit, the IDM showed a correlation of R2 = 0.39 between the saliva Test Line absorption and the measured tacrolimus concentration in blood, with an average absolute error of 1.8 ng/mL. Our results demonstrate a clear correlation between blood and saliva measurements. The IDM provided promising results to monitor immunosuppressant drug concentrations in patients after transplantation. Future larger studies will further develop the correlation, and the IDM's potential impact on patient outcomes.


Subject(s)
Immunosuppressive Agents , Tacrolimus , Humans , Male , Female , Young Adult , Adult , Middle Aged , Aged , Saliva , Quality of Life
12.
J Reconstr Microsurg ; 40(1): 78-86, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37040875

ABSTRACT

BACKGROUND: Lower extremity free flap failure rates are higher than in other areas of the body. While prior studies assessed the effect of intraoperative technical variables, these generally investigated individual variables and did not examine relationships between the many individual technical decisions made during free tissue reconstruction. Our purpose was to investigate the effect of variation in intraoperative microsurgical techniques on flap outcomes in a diverse cohort of patients requiring lower extremity free flap coverage. METHODS: Consecutive patients undergoing free flap reconstruction of the lower extremity at two level 1 trauma centers from January 2002 to January 2020 were identified using Current Procedural Terminology codes, followed by a review of medical records. Information regarding demographics and comorbidities, indications, intraoperative technical details, and complications was collected. Outcomes of interest included an unplanned return to the operating room, arterial thrombosis, venous thrombosis, partial flap failure, and total flap failure. Bivariate analysis was performed. RESULTS: In total, 410 patients underwent 420 free tissue transfers. The median follow-up time was 17 months (interquartile ranges: 8.0-37). Total flap failure occurred in 4.9% (n = 20), partial flap failure in 5.9% (n = 24), and unplanned reoperation in 9.0% (n = 37), with arterial thrombosis in 3.2% (n = 13) and venous thrombosis in 5.4% (n = 22). Overall complications were significantly associated with recipient artery choice, with arteries other than PT and AT/DP having a higher rate (p = 0.033), and with arterial revisions (p = 0.010). Total flap failure was also associated with revision of the arterial anastomosis (p = 0.035), and partial flap failure was associated with recipient artery choice (p = 0.032). CONCLUSION: Many interoperative options and techniques are available when performing microvascular lower extremity reconstruction that leads to equally high success rates. However, the use of arterial inflow outside of the posterior tibial and anterior tibial arteries leads to a higher overall complication rate and partial flap failure rate. Intraoperative revision of the arterial anastomosis portends poorly for ultimate flap survival.


Subject(s)
Free Tissue Flaps , Venous Thrombosis , Humans , Free Tissue Flaps/blood supply , Treatment Outcome , Retrospective Studies , Lower Extremity/surgery , Lower Extremity/injuries , Postoperative Complications
13.
Bioengineering (Basel) ; 10(12)2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38136006

ABSTRACT

Machine perfusion has developed rapidly since its first use in solid organ transplantation. Likewise, reconstructive surgery has kept pace, and ex vivo perfusion appears as a new trend in vascularized composite allotransplants preservation. In autologous reconstruction, fasciocutaneous flaps are now the gold standard due to their low morbidity (muscle sparing) and favorable functional and cosmetic results. However, failures still occasionally arise due to difficulties encountered with the vessels during free flap transfer. The development of machine perfusion procedures would make it possible to temporarily substitute or even avoid microsurgical anastomoses in certain complex cases. We performed oxygenated acellular sub-normothermic perfusions of fasciocutaneous flaps for 24 and 48 h in a porcine model and compared continuous and intermittent perfusion regimens. The monitored metrics included vascular resistance, edema, arteriovenous oxygen gas differentials, and metabolic parameters. A final histological assessment was performed. Porcine flaps which underwent successful oxygenated perfusion showed minimal or no signs of cell necrosis at the end of the perfusion. Intermittent perfusion allowed overall better results to be obtained at 24 h and extended perfusion duration. This work provides a strong foundation for further research and could lead to new and reliable reconstructive techniques.

14.
Bioengineering (Basel) ; 10(12)2023 Dec 18.
Article in English | MEDLINE | ID: mdl-38136031

ABSTRACT

Autonomization is a physiological process allowing a flap to develop neo-vascularization from the reconstructed wound bed. This phenomenon has been used since the early application of flap surgeries but still remains poorly understood. Reconstructive strategies have greatly evolved since, and fasciocutaneous flaps have progressively replaced muscle-based reconstructions, ensuring better functional outcomes with great reliability. However, plastic surgeons still encounter challenges in complex cases where conventional flap reconstruction reaches its limitations. Furthermore, emerging bioengineering applications, such as decellularized scaffolds allowing a complex extracellular matrix to be repopulated with autologous cells, also face the complexity of revascularization. The objective of this article is to gather evidence of autonomization phenomena. A systematic review of flap autonomization is then performed to document the minimum delay allowing this process. Finally, past and potential applications in bio- and tissue-engineering approaches are discussed, highlighting the potential for in vivo revascularization of acellular scaffolds.

15.
Ann Transl Med ; 11(11): 392, 2023 Oct 25.
Article in English | MEDLINE | ID: mdl-37970607

ABSTRACT

Background: Ehlers-Danlos syndrome (EDS) is a rare genetic disorder that causes abnormal collagen structure and production, seriously impacting the quality of connective tissues. Reconstructive surgery can be challenging in affected patients, and additional precautions should be taken for microsurgical transfers. Case Description: This case aimed to describe the management of a 27-year-old man with vascular EDS and a history of heavy smoking who developed a voluminous enterocutaneous fistula after multiple abdominal surgeries. Due to the high surgical risk of flap failure resulting from the patient's condition, the large full-thickness abdominal defect, and the lack of locoregional reconstructive options, a two-stage free latissimus dorsi flap reconstruction was performed. A left myocutaneous free latissimus dorsi flap (sized 10 cm × 25 cm) was transferred and anastomosed to the left superficial femoral artery and the proximal part of the rerouted greater saphenous vein. The flap was folded, sutured to itself, and left in place for 8 days. Once the flap's viability was confirmed, complete small bowel liberation with resection of the enterocutaneous fistula and end-to-end primary anastomosis were performed by the visceral surgeons. The latissimus dorsi flap was unfolded and moved cephalically to cover the defect. No complications were reported on the flap. A fistula recurrence occurred on postoperative day 9 but was successfully addressed within 6 weeks using a combination of nasogastric tube aspiration, somatostatin, antibiotics, and negative pressure therapy. Follow-up at 6 months showed complete wound healing with no further complications. Conclusions: This report suggests the two-stage free flap transfer strategy to manage a voluminous full-thickness abdominal wall defect in a patient with vascular EDS. This approach allowed for optimal tissue coverage and full abdominal restoration while minimizing the risk of complications.

16.
Plast Reconstr Surg Glob Open ; 11(8): e5205, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37636329

ABSTRACT

Penile amputation is a surgical emergency where practical and timely perioperative management is crucial for ensuring a successful outcome. Tenuous viability of penile and scrotal skin has been well described in the literature, with a putative mechanism attributed to the transection of distal branches of the external pudendal artery. Although the perforasomes critical to penile replantation have been debated, this case report details a patient who successfully recovered sensation and function with minimal necrosis after penile replantation. Surgically, this was facilitated by intentional drain placement, aggressive debridement beyond the zone of injury, and planned redundancies with dorsal artery/vein anastomoses via interposition grafts of the dorsal penile vessels alone.

17.
J Plast Reconstr Aesthet Surg ; 86: 8-14, 2023 11.
Article in English | MEDLINE | ID: mdl-37643527

ABSTRACT

INTRODUCTION: Genital affirmation surgery (GAS) requests are consistently increasing in demand. The gold standard is penile skin inversion, using cutaneous grafting for neovagina creation. The aim is to achieve the most realistic results both physically and functionally. Different studies have contradictory results, and the use of lubrication is insufficiently clear, while the use of sigmoidoplasty has been defended for constant lubrication. AIMS: Our aim was to evaluate transgender women's sexual function and lubrication after vaginoplasty by penile skin inversion. METHODS: We performed a prospective study on 45 patients who underwent primary penile inversion vaginoplasty. Participants answered two questionnaires during the follow-up consultation: the Female Sexual Function Index (FSFI) and an 18-item custom questionnaire. RESULTS: The average FSFI score of our patients was 28.9, up to the cut-off defining a sexual disorder. Compared to the Wylomanski control group, no differences were found for the FSFI score and in the subgroups. Considering lubrication, 69% of the patients were satisfied or very satisfied with their lubrication. Furthermore, 53% reported a fluid release at each orgasm. CONCLUSION: This study reported high satisfaction for both sexuality and lubrication, proning against penile inversion's GAS bad reputation concerning postoperative lubrication. A squirting effect was described for the first time and was present in 53% of our transpatients.


Subject(s)
Sex Reassignment Surgery , Transgender Persons , Humans , Female , Sex Reassignment Surgery/methods , Prospective Studies , Lubrication , Sexuality , Vagina/surgery , Surveys and Questionnaires
19.
J Med Case Rep ; 17(1): 321, 2023 Jul 26.
Article in English | MEDLINE | ID: mdl-37491356

ABSTRACT

BACKGROUND: Hemorrhage is an uncommon complication of liposuction that may be trauma-induced by the cannula on the subcutaneous perforators. It usually resolves spontaneously with external compression and results in mild to moderate ecchymosis on the liposuction site. However, in sporadic cases, active bleeding may persist and require urgent intervention for hemostasis. CASE PRESENTATION: We report the case of a 60-year-old White female who developed a massive hematoma in the hour following liposuction of the right internal thigh, with active bleeding in the subcutaneous plane reported on contrast-enhanced computed tomography. The initial angiogram was conducted in the right common femoral artery and showed active bleeding from a profunda artery perforator. After careful selective catheterization of the feeding artery using a 2.0-French microcatheter, 0.3 mL of Onyx 34 was injected. Control angiography showed no immediate complication and confirmed the exclusion of the pseudoaneurysm. No postoperative event occurred. Blood pressure and hemoglobin levels remained stable throughout the episode. CONCLUSIONS: Although liposuction is a very common procedure in plastic surgery, hemorrhagic complications may occur and require urgent hemostasis. This case suggests a vital place for interventional radiology in the management of hemorrhagic complications after liposuction.


Subject(s)
Embolization, Therapeutic , Lipectomy , Humans , Female , Middle Aged , Lipectomy/adverse effects , Thigh , Embolization, Therapeutic/methods , Angiography , Hemorrhage/surgery , Rupture/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery
20.
J Vis Exp ; (196)2023 06 30.
Article in English | MEDLINE | ID: mdl-37458471

ABSTRACT

Blood samples are required in most experimental animal designs to assess various hematological parameters. This paper presents two procedures for blood collection in rats: the lateral tail vein puncture and the dorsal penile vein puncture, which offer significant advantages over other previously described techniques. This study shows that these two procedures allow for fast sampling (under 10 min) and yield sufficient blood volumes for most assays (202 µL ± 67.7 µL). The dorsal penile vein puncture must be done under anesthesia, whereas the lateral tail vein puncture can be done on a conscious, restrained animal. Alternating these two techniques, therefore, enables blood draw in any situation. While it is always recommended for an operator to be assisted during a procedure to ensure animal welfare, these techniques require only a single operator, unlike most blood sampling methods that require two. Moreover, whereas these previously described methods (e.g., jugular stick, subclavian vein blood draw) require extensive prior training to avoid harm to or death of the animal, tail vein and dorsal penile vein puncture are rarely fatal. For all these reasons, and according to the context (e.g., for studies including male rats, during the perioperative or immediate postoperative period, for animals with thin tail veins), both techniques can be used alternately to enable repeated blood draws.


Subject(s)
Blood Specimen Collection , Tail , Rats , Male , Animals , Tail/surgery , Tail/blood supply , Blood Specimen Collection/methods , Punctures , Animals, Laboratory , Subclavian Vein , Jugular Veins
SELECTION OF CITATIONS
SEARCH DETAIL
...