Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Equine Vet J ; 51(4): 489-494, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30353944

ABSTRACT

BACKGROUND: Control of equine infectious anaemia (EIA) currently depends on serological diagnosis of infected equids. However, recently infected equids may not produce detectable anti-EIAV antibodies up to 157 days post infection and so present a high transmission risk. Therefore, direct nucleic acid detection methods are urgently needed to improve EIAV surveillance and management programs in counties where the disease is endemic. OBJECTIVES: To evaluate a field-deployable, reverse transcription-insulated isothermal PCR (RT-iiPCR) assay targeting the conserved 5' untranslated region (5' UTR)/exon 1 of the tat gene of EIAV. STUDY DESIGN: The analytical and clinical performance of the newly developed EIAV RT-iiPCR was evaluated by comparison with a EIAV real-time RT-PCR (RT-qPCR) along with the AGID test. METHODS: Analytical sensitivity was determined using in vitro transcribed RNA containing the target area of the 5' UTR/tat gene and samples from two EIAV-positive horses. Specificity was verified using nine common equine viruses. Clinical performance was evaluated by comparison with EIAV RT-qPCR and AGID using samples derived from 196 inapparent EIAV carrier horses. RESULTS: EIAV RT-iiPCR did not react with other commonly encountered equine viruses and had equivalent sensitivity (95% detection limit of eight genome equivalents), with a concordance of 95.41% to conventional EIAV RT-qPCR. However, the RT-qPCR and RT-iiPCR had sensitivities of 43.75 and 50.00%, respectively, when compared to the AGID test. MAIN LIMITATIONS: Low viral loads commonly encountered in inapparent EIAV carriers may limit the diagnostic sensitivity of RT-PCR-based tests. CONCLUSIONS: Although EIAV RT-iiPCR is not sufficiently sensitive to replace the current AGID test, it can augment control efforts by identifying recently exposed or "serologically silent" equids, particularly as the latter often represent a significant transmission risk because of high viral loads. Furthermore, the relatively low cost and field-deployable design enable utilisation of EIAV RT-iiPCR even in remote regions.


Subject(s)
Equine Infectious Anemia/diagnosis , Infectious Anemia Virus, Equine/isolation & purification , RNA, Viral/isolation & purification , Reverse Transcriptase Polymerase Chain Reaction/veterinary , Animals , Equine Infectious Anemia/blood , Equine Infectious Anemia/virology , Horses , Reverse Transcriptase Polymerase Chain Reaction/methods , Sensitivity and Specificity , Serologic Tests
SELECTION OF CITATIONS
SEARCH DETAIL
...