Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
Add more filters










Publication year range
1.
Vet Surg ; 52(8): 1140-1149, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37534913

ABSTRACT

OBJECTIVE: To evaluate the effects of three adjunctive methods of tension band wire fixation (TBWF) on the biomechanical properties, gap formation, and failure mode in simulated canine patella tendon rupture (RPT). STUDY DESIGN: Randomized, ex vivo. SAMPLE POPULATION: Paired hindlimbs from 32 dog cadavers. METHODS: Patellar tendons (PTs) and associated bone-muscle-tendon units were harvested. Each PT was transected then sutured using a core locking loop and simple continuous epitendinous pattern. Each hindlimb was randomly assigned to one of three groups (n = 18 hindlimbs/group) using 18 gauge 316 L wire, anchored to the tibial crest distally, to perform transpatellar, suprapatellar, or combined tension band-wire (TBW) augmentation. Ten hindlimbs were utilized as control specimens. Yield, peak, and failure loads, stiffness, loads to 1 and 3 mm gap formation, and failure mode were evaluated. RESULTS: Combined transpatellar and suprapatellar TBW augmentation was superior to transpatellar or suprapatellar groups alone. Yield (p = .0008), peak (p = .004), and failure loads (p = .005) were greater for the combined group than for the transpatellar (p = .048) and suprapatellar groups (p = .01) respectively. There was no difference regarding the occurrence of 1 or 3 mm gap formation (1 mm, p = .05; 3 mm, p = .06); however, loads required to cause gap formation were greater in the combined group (p = .036). Mode of failure differed between techniques used for PT augmentation (p < .001). CONCLUSION: Combined transpatellar and suprapatellar adjunctive TBW augmentation for simulated PT repairs was biomechanically superior to either transpatellar or suprapatellar TBWF alone. CLINICAL SIGNIFICANCE: Combined suprapatellar and transpatellar TBWF may offer a viable surgical option for increased repair-site strength and greater loads to gap formation. Further studies investigating alternative techniques and materials for RPT repair augmentation are warranted.


Subject(s)
Dog Diseases , Patellar Ligament , Dogs , Animals , Patellar Ligament/surgery , Biomechanical Phenomena , Suture Techniques/veterinary , Tendons/surgery , Fracture Fixation, Internal/veterinary , Cadaver , Sutures/veterinary , Dog Diseases/surgery
2.
Vet Med Sci ; 9(4): 1513-1520, 2023 07.
Article in English | MEDLINE | ID: mdl-37291754

ABSTRACT

BACKGROUND: Transitional cell carcinoma (TCC) is the most common neoplasia affecting the canine urinary bladder. Partial cystectomy, when used adjuctively with medical management, has been shown to meaningfully extend medial survival time. Surgical stapling devices have a wide variety of uses and advantages over traditional closure methods and, to date, investigation into their use in canine partial cystectomies has not been documented. OBJECTIVE: To determine the influence of three closure techniques on ex vivo leakage pressures and leakage location following canine partial cystectomy. METHODS: Specimens were assigned to one of three closure techniques: simple continuous appositional closure with 3-0 suture, closure with a 60 mm gastrointestinal stapler with a 3.5 mm cartridge, and placement of a Cushing suture to augment the stapled closure, with each group containing 12 specimens. Mean initial leakage pressure (ILP), maximum leakage pressure (MLP), and leakage location at the time that ILP was recorded were compared between groups. RESULTS: Oversewn stapled constructs leaked at significantly higher ILP (28.5 mmHg) than those in the sutured (17 mmHg) or stapled (22.8 mmHg) group, respectively. MLP was greater in the oversewn stapled construct group compared to other groups. Leakage was detected in 97% partial cystectomies, with leakage occurring from the needle holes in 100% of the sutured closure group, from the staple holes in 100% of the stapled only group, and from the incisional line in 83% and from bladder wall rupture in 8% of the augmented staple closure group. All closure methods withstood normal physiologic cystic pressures. CONCLUSIONS: Placement of a Cushing suture to augment stapled closures improved the ability of partial cystectomies to sustain higher intravesicular pressures compared with sutured or stapled bladder closures alone. Further in vivo studies are required to determine the clinical significance of these findings and the role of stapling equipment for partial cystectomy, as well as the clinical significance of suture penetration through the urinary bladder mucosa during closure.


Subject(s)
Dog Diseases , Urinary Bladder , Animals , Dogs , Cystectomy/veterinary , Dog Diseases/surgery , Sutures/veterinary , Urinary Bladder/surgery
3.
Vet Comp Orthop Traumatol ; 36(2): 75-81, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36690022

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the effect of Kirschner wire insertion angle on the biomechanical characteristics following tibial tuberosity osteotomy fixation in dogs. STUDY DESIGN: Twelve pairs of cadaveric tibia were harvested and randomly assigned to two treatment groups. Kirschner wires were placed either transversely (0 degrees) or placed caudodistally (30 degrees) with respect to the tibial tuberosity osteotomy. Each limb acted as its own respective control. Radiographic analysis allowed for the calculation of Kirschner wire insertion angle variance. Constructs were tested to monotonic failure while evaluating yield, peak, and failure forces, construct stiffness, and failure mode. RESULTS: Kirschner wire insertion angles were 1.1 ± 2.2 degrees and 30.5 ± 2.3 degrees, respectively, for 0-degree and 30-degree groups (p <0.0001). Yield (p = 0.0095), peak (p <0.024) and failure loads (p <0.030) were all significantly greater for Kirschner wires inserted at an angle of 0 degrees compared with 30 degrees. Construct stiffness did not differ regardless of insertion angle (p = 0.068). Failure mode did not differ (p = 0.87) with tibial tuberosity avulsion and Kirschner wire pull-out seen in the majority of constructs (67%). CONCLUSION: Kirschner wires placed transversely (0 degrees) for tibial tuberosity osteotomy fixation were biomechanically superior, increasing yield, peak, and failure forces by 1.6 times, 1.3 times, and 1.4 times, respectively, to those placed in a caudodistal (30 degrees) orientation. Kirschner wire insertion angle is an important consideration following tibial tuberosity osteotomy in dogs, with Kirschner wires placed at 0 degrees conferring increased resistance of the repair to construct deformation.


Subject(s)
Bone Wires , Tibia , Dogs , Animals , Tibia/surgery , Biomechanical Phenomena , Osteotomy/veterinary
4.
Am J Vet Res ; 83(7)2022 Jun 11.
Article in English | MEDLINE | ID: mdl-35930778

ABSTRACT

OBJECTIVE: To evaluate the effect of a double Krackow suture pattern (DK), with and without epitendinous suture augmentation (ES), in a canine gastrocnemius tendon (GT) model. SAMPLE: Paired GTs from 12 adult dog cadavers and 4 control GT. PROCEDURES: GTs were assigned to 2 groups (n = 12/group). Transverse tenotomy was performed and repaired with a DK or DK + ES. Yield, peak, and failure force, stiffness, occurrence of 1-and 3-mm gapping, and failure mode were examined. RESULTS: Yield, peak, and failure loads were greater for DK + ES. Yield force was 48% greater for DK + ES (mean ± SD, 149.56 ± 53.26 N) versus DK (101.27 ± 37.17 N; P = 0.017). Peak force was 45% greater for DK + ES P < 0.001). Failure force was 47% greater for DK + ES (193.752 ± 31.43 N) versus DK (131.54 ± 22.28 N; P < 0.001). Construct stiffness was 36% greater for DK + ES (P = 0.04). All 12 DK and 10 of 12 DK + ES repairs produced a 1-mm gap, with all DK and 4 DK + ES repairs producing a 3-mm gap (P < 0.001). Loads required to create a 3-mm gap were significantly greater for DK + ES (P < 0.013). Suture breakage occurred in all DK repairs, which differed from DK + ES, where suture breakage (7/12) and tissue failure (5/12; P = 0.037) predominated. CLINICAL RELEVANCE: Augmentation of a primary DK repair with an ES significantly improved construct strength in canine GT constructs while increasing loads required to cause 1- and 3-mm gap formation, respectively. ES augmentation is a simple technique modification that can be used to significantly increase construct strength, compared with DK alone.


Subject(s)
Dog Diseases , Tendon Injuries , Animals , Biomechanical Phenomena , Cadaver , Dog Diseases/surgery , Dogs , Suture Techniques/veterinary , Sutures/veterinary , Tendon Injuries/surgery , Tendon Injuries/veterinary , Tendons/surgery , Tensile Strength
5.
Am J Vet Res ; 83(9)2022 Jul 23.
Article in English | MEDLINE | ID: mdl-35895771

ABSTRACT

OBJECTIVE: To evaluate effects of loop diameter of a modified Kessler locking-loop (LL) suture on in vitro tensile strength and gapping characteristics of canine flexor tendon repairs. SAMPLE: 48 cadaveric superficial digital flexor tendons from 24 adult medium- to large-breed dogs. PROCEDURES: Flexor tendons were randomly assigned to 4 groups (n = 12/group) and repaired with 2-0 polypropylene in a LL pattern with loops measuring 1, 2, 3, or 4 mm in diameter. Biomechanical loads, gap formation between tendon ends, and failure modes were evaluated and compared between groups. RESULTS: Increasing loop diameter from 1 to 4 mm significantly increased yield (P = .048), peak (P < .001), and failure (P < .001) loads. There were no significant differences in yield, peak, and failure loads between 1- and 2-mm loops. Load to 3-mm gap formation was significantly (P < .001) greater for 4-mm loops, compared with 1-, 2-, and 3-mm loops. Failure mode did not differ significantly among experimental groups, with 46 of 48 (96%) of constructs failing because of suture breakage. CLINICAL RELEVANCE: Loop diameter of a LL suture pattern is an important biomechanical variable that influences construct biomechanics of canine tendon suture repairs. Loop diameters > 3 mm are recommended when the size of the tendon allows. Further studies are necessary to determine the in vivo effect of these findings, particularly the effects on tendon blood supply.


Subject(s)
Suture Techniques , Tendon Injuries , Animals , Biomechanical Phenomena , Cadaver , Dogs , Suture Techniques/veterinary , Tendon Injuries/surgery , Tendon Injuries/veterinary , Tensile Strength
6.
Am J Vet Res ; 83(9)2022 Jul 23.
Article in English | MEDLINE | ID: mdl-35895776

ABSTRACT

OBJECTIVE: To evaluate the influence of superficial digital flexor tendon (SDFT) graft augmentation on the biomechanical properties and resistance to gap formation in a canine gastrocnemius tendon repair model. SAMPLE POPULATION: 28 canine cadaveric hind limbs. PROCEDURES: Respective hindlimbs from each dog were randomized to one of two groups (n = 14/group) using a 3-loop-pulley (3LP) pattern alone or 3LP + SDFT graft augmentation. Biomechanical parameters evaluated included yield, peak, and failure loads; tensile loads required to create 1- and 3-mm gap formations; and mode of construct failure. RESULTS: Mean yield and failure loads for the 3LP + SDFT graft group were 483.6 ± 148.0 N and 478.3 ± 147.9 N, respectively, and were greater compared to the 3LP group (34.2 ± 6.7 N and 34.0 ± 8.0 N, P < .0001). Loads to both 1- and 3-mm gap formations for the 3LP + SDFT graft group were greater compared to 3LP alone (P < .001). Failure modes did not differ between groups (P = .120), with constructs failing most commonly by suture pulling through opposed tendinous tissues whereas SDFT grafts remained intact. CLINICAL RELEVANCE: SDFT graft augmentation increased yield, peak, and failure forces 14-fold across all examined biomechanical variables compared to the 3LP group. The 3LP + SDFT graft group required 3.6X and 6.5X greater loads to cause a 1- and 3-mm gap, respectively, between tendon ends. These data support the biomechanical advantages of SDFT graft augmentation to increase repair-site strength and to promote resistance to gap formation of the tenorrhaphy. Additional in vivo studies are required to determine the effect of SDFT augmentation on clinical function and active limb use after graft harvest in dogs.


Subject(s)
Dog Diseases , Tendon Injuries , Animals , Dogs , Biomechanical Phenomena , Dog Diseases/surgery , Suture Techniques/veterinary , Tendon Injuries/surgery , Tendon Injuries/veterinary , Tendons/surgery , Tensile Strength
7.
Am J Vet Res ; 83(8)2022 Jun 28.
Article in English | MEDLINE | ID: mdl-35895778

ABSTRACT

OBJECTIVE: To compare the biomechanical properties and gapping characteristics following loop modification of a 3-loop-pulley (3LP) pattern in an ex vivo canine common calcaneal tendon (CCT) avulsion repair model. SAMPLE: 56 skeletally mature hindlimbs from 28 canine cadavers. PROCEDURES: The CCTs were randomized to 1 of 4 experimental groups (n = 14/group) then sharply transected at the teno-osseous junction. Groups consisted of a 3LP, 4-loop-pulley (4LP), 5-loop-pulley (5LP), or 6-loop-pulley (6LP) pattern with loops placed 60° apart using size-0 polypropylene. Yield, peak, and failure loads, construct stiffness, loads to produce a 3-mm teno-osseous gap, and failure mode were evaluated and compared between groups. RESULTS: Yield (P = 0.001), peak (P < 0.001), and failure loads (P < 0.001), construct stiffness (P < 0.001), and loads to 3-mm gap formation (P = 0.005) were all significantly greater for 6LP compared to all other groups. Mode of failure did not differ among groups (P = 0.733) with 75% (42/56) of repairs failing by mechanism of core sutures pulling through the tendinous tissue. Pattern modification by increasing the number of loops increased the repair site strength by 1.4, 1.6, and 1.8 times for 4LP, 5LP, and 6LP compared to 3LP, respectively. CLINICAL RELEVANCE: Increasing the number of suture loops compared to a traditional 3LP repair is a relatively simple technique modification that significantly increases teno-osseous repair site strength and loads required to cause 3-mm gap formation. The results of this study justify further focused investigation of increasing the number of suture loops in vivo for teno-osseous CCT repair in dogs.


Subject(s)
Dog Diseases , Tendon Injuries , Animals , Biomechanical Phenomena , Cadaver , Dog Diseases/surgery , Dogs , Suture Techniques/veterinary , Sutures/veterinary , Tendon Injuries/surgery , Tendon Injuries/veterinary , Tendons/surgery , Tensile Strength
8.
Vet Surg ; 51(5): 801-808, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35614547

ABSTRACT

OBJECTIVE: To evaluate the influence of barbed suture oversew of the transverse staple line during functional end-to-end stapled anastomosis (FEESA) in dogs. STUDY DESIGN: Randomized, experimental, ex vivo. ANIMALS OR SAMPLE POPULATION: Grossly normal jejunal segments from 14 adult canine cadavers. METHODS: Ninety-eight jejunal segments (n = 14/FEESA group, n = 14 controls) were harvested and randomly assigned to a control group, FEESA + monofilament suture oversew, FEESA + unidirectional barbed suture oversew or FEESA + bidirectional barbed suture oversew. Oversew techniques were performed using a Cushing suture pattern. Initial (ILP) and maximum leakage pressure (MLP), repair time (s), and location of observed leakage were recorded. RESULTS: No differences were detected in ILP (p = .439) or MLP (p = .644) respectively between experimental groups. Repairs times using barbed suture were ~ 18% faster (~25 s faster; p < .001) compared to monofilament suture. There was no difference between barbed suture types (p = .697). Mean ILP (p < .001) and MLP (p < .0001) were 6.6x and 5.1x greater respectively in the control group. Leakage location occurred predominately at the crotch of the FEESA in all groups. CONCLUSION: FEESAs closed with a transverse staple line oversew using barbed suture, regardless of barb orientation, were completed faster and resulted in similar resistance to anastomotic leakage compared to monofilament suture. CLINICAL SIGNIFICANCE: Oversewing the transverse staple line following FEESA using barbed suture offers similar resistance to anastomotic leakage, and may be associated with decreased surgical times in dogs compared to monofilament suture. Further studies are necessary to determine the benefits of barbed suture use in both open and laparoscopic gastrointestinal surgical applications following FEESA in dogs.


Subject(s)
Digestive System Surgical Procedures , Dog Diseases , Anastomosis, Surgical/methods , Anastomosis, Surgical/veterinary , Anastomotic Leak/veterinary , Animals , Digestive System Surgical Procedures/veterinary , Dogs , Suture Techniques/veterinary , Sutures/veterinary
9.
Vet Surg ; 51(4): 688-696, 2022 May.
Article in English | MEDLINE | ID: mdl-35277992

ABSTRACT

OBJECTIVE: To determine the influence of bone-tunnel anchoring technique on teno-osseous repair of the common calcanean tendon (CCT) in dogs. STUDY DESIGN: Randomized, ex vivo, biomechanical. POPULATION: Forty-two skeletally mature canine hindlimbs. METHODS: Canine hindlimbs were dissected to produce a model simulating avulsion of the CCT and accessory tendons from the calcaneus. Hindlimbs were randomized to 1 of 3 anchoring techniques (n = 14/group): a single transverse tunnel (TT), vertical tunnels (VT), or modified bone tunnels (MT) for teno-osseous repair in a 3-loop-pulley (3LP) pattern using 0 USP polypropylene. Yield, peak and failure loads, construct stiffness, loads to produce a 3 mm teno-osseous gap, and failure modes were compared between groups. RESULTS: The only difference detected consisted of TT constructs yielding at loads 25% higher than MT constructs (P = .027). CONCLUSION: Although yield loads were lower in MT constructs than other groups, the bone-tunnel anchoring techniques tested here did not appear to influence the biomechanical properties or gapping characteristics of teno-osseous repairs in this canine CCT avulsion model. CLINICAL SIGNIFICANCE: All drilling techniques and bone-tunnel orientations tested in the study reported here offer viable options to reattach the CCT to the calcaneus. Surgeons should evaluate how bone-tunnel orientation may affect placement of adjunctive fixation methods to stabilize the talocrural joint after primary CCT repair in dogs.


Subject(s)
Achilles Tendon , Dog Diseases , Tendon Injuries , Achilles Tendon/surgery , Animals , Biomechanical Phenomena , Cadaver , Dog Diseases/surgery , Dogs , Suture Techniques/veterinary , Tendon Injuries/surgery , Tendon Injuries/veterinary
10.
Am J Vet Res ; 83(4): 305-311, 2022 Jan 28.
Article in English | MEDLINE | ID: mdl-35092666

ABSTRACT

OBJECTIVE: To evaluate the effects of using an internal fixation plate to augment primary 3-loop pulley (3LP) repair of canine gastrocnemius tendons (GTs). SAMPLE: 48 cadaveric GTs from 24 adult dogs. PROCEDURES: GTs were dissected free from other tissues, transected, and randomly assigned to 4 groups (n = 12/group). GTs were repaired with 2-0 polypropylene with a 3LP repair alone or a 3LP repair augmented with a 3-hole veterinary cuttable plate (3VCP), a 5-hole veterinary cuttable plate (5VCP), or a 7-hole veterinary cuttable plate (7VC P). Biomechanical loads, construct stiffness, gap formation, and failure modes were compared between groups. RESULTS: Yield, peak, and failure loads were all significantly increased for the 5VCP and 7VCP groups, compared with the 3LP alone group. Increasing plate length from 3VCP to 5VCP and from 3VCP to 7VCP increased yield, peak, and failure loads. No differences were found between the 3LP and 3VCP groups with regard to yield and peak loads, but failure load was increased in the 3VCP group. Loads to create 1-mm and 3-mm gaps were significantly greater for the 5VCP and 7VCP groups, compared with the 3LP alone and 3VCP groups. Mode of plate attachment failure differed among groups. CLINICAL RELEVANCE: Tendon plate augmentation may be a viable surgical option to increase the strength of the tenorrhaphy in dogs. However, in vivo studies evaluating the effects of plate augmentation on the tendon blood supply and progression of healing are needed prior to clinical application.


Subject(s)
Dog Diseases , Tendon Injuries , Animals , Dogs , Biomechanical Phenomena , Cadaver , Dog Diseases/surgery , Fracture Fixation, Internal/veterinary , Suture Techniques/veterinary , Tendon Injuries/surgery , Tendon Injuries/veterinary , Tendons/surgery , Tensile Strength
11.
Vet Surg ; 51(4): 697-705, 2022 May.
Article in English | MEDLINE | ID: mdl-35020207

ABSTRACT

OBJECTIVE: To determine the influence of anastomotic crotch suture augmentation on leakage pressures and leakage location following intestinal functional end-to-end stapled anastomosis (FEESA) in dogs. STUDY DESIGN: Ex vivo, randomized, experimental. SAMPLE POPULATION: Chilled jejunal segments from 3 adult dogs. METHODS: Jejunal specimens were tested within 24 hours of collection. A FEESA was performed and randomly assigned to 1 of 4 treatment groups (n = 12/group): (1) no crotch suture (NCS); (2) simple interrupted crotch suture (SICS); (3) two simple interrupted crotch sutures (TCS) placed laterally on opposing jejunal limbs; (4) simple continuous crotch suture (SCCS) augmentation. Crotch sutures were performed using 3-0 USP polydioxanone. Initial (ILP) and maximal (MLP) leakage pressures (Mean ± SD mm Hg) and leakage location were recorded and compared between groups. RESULTS: Initial leakage pressure was greater after placement of TCS (37.8 ± 6.4, P < .039) and SCCS (47.6 ± 11.0, P < .002) than NCS (27.1 ± 2.5) and SICS (33.0 ± 6.0). Maximal leakage pressure was greater in specimens including SICS, TCS, and SCCS than those without crotch suture augmentation (P < .043). Leakage occurred at the anastomotic crotch in 8/12 NCS, 6/12 SICS, 11/12 TCS, and 12/12 SCCS constructs (P < .001). CONCLUSION: Augmentation of FEESA with TCS and SCCS increased ILP and decreased the occurrence of leakage from the anastomotic crotch, while all methods of anastomotic crotch augmentation increased MLP. CLINICAL SIGNIFICANCE: Augmenting the FEESA with crotch suture(s) improved the resistance of the jejunal anastomosis to leakage in normal cadaveric segments. Placing 2 crotch sutures or use of a simple continuous pattern for anastomotic augmentation appeared to be superior to the placement of a single suture.


Subject(s)
Suture Techniques , Sutures , Anastomosis, Surgical/methods , Anastomosis, Surgical/veterinary , Animals , Dogs , Jejunum/surgery , Neurosurgical Procedures/veterinary , Suture Techniques/veterinary , Sutures/veterinary
12.
Cell Rep ; 37(13): 110128, 2021 12 28.
Article in English | MEDLINE | ID: mdl-34965412

ABSTRACT

Microglia, the resident macrophages in the central nervous system, express receptors for classical neurotransmitters, such as γ-aminobutyric acid (GABA) and glutamate, suggesting that they sense synaptic activity. To detect microglial Ca2+ responses to neuronal activity, we generate transgenic mouse lines expressing the fluorescent Ca2+ indicator GCaMP6m, specifically in microglia and demonstrate that electrical stimulation of the Schaffer collateral pathway results in microglial Ca2+ responses in early postnatal but not adult hippocampus. Preceding the microglial responses, we also observe similar Ca2+ responses in astrocytes, and both are sensitive to tetrodotoxin. Blocking astrocytic glutamate uptake or GABA transport abolishes stimulation-induced microglial responses as well as antagonizing the microglial GABAB receptor. Our data, therefore, suggest that the neuronal activity-induced glutamate uptake and the release of GABA by astrocytes trigger the activation of GABAB receptors in microglia. This neuron, astrocyte, and microglia communication pathway might modulate microglial activity in developing neuronal networks.


Subject(s)
Calcium/metabolism , Glutamic Acid/metabolism , Hippocampus/metabolism , Microglia/metabolism , Neurons/metabolism , Receptors, GABA/metabolism , gamma-Aminobutyric Acid/metabolism , Animals , Animals, Newborn , Electric Stimulation , Female , Male , Mice , Mice, Inbred C57BL , Mice, Transgenic
13.
Am J Vet Res ; 82(12): 942-947, 2021 Nov 26.
Article in English | MEDLINE | ID: mdl-34727071

ABSTRACT

OBJECTIVE: To evaluate the effect of knot location on the biomechanical strength and gapping characteristics of ex vivo canine gastrocnemius tenorrhaphy constructs. SAMPLE: 36 cadaveric gastrocnemius tendons from 18 adult dogs. PROCEDURES: Tendons were randomly assigned to 3 groups (12 tendons/group) and sharply transected and repaired by means of a core locking-loop suture with the knot at 1 of 3 locations (exposed on the external surface of the tendon, buried just underneath the external surface of the tendon, or buried internally between the apposed tendon ends). All repairs were performed with size-0 polypropylene suture. All constructs underwent a single load-to-failure test. Yield, failure, and peak forces, mode of failure, and forces required for 1- and 3-mm gap formation were compared among the 3 knot-location groups. RESULTS: Mean yield, failure, and peak forces and mean forces required for 1- and 3-mm gap formation did not differ significantly among the 3 groups. The mode of failure also did not differ significantly among the 3 groups, and the majority (33/36 [92%]) of constructs failed owing to the suture pulling through the tendinous substance. CONCLUSIONS AND CLINICAL RELEVANCE: Final knot location did not significantly affect the biomechanical strength and gapping characteristics of canine gastrocnemius tenorrhaphy constructs. Therefore, all 3 evaluated knot locations may be acceptable for tendon repair in dogs. In vivo studies are necessary to further elucidate the effect of knot location in suture patterns commonly used for tenorrhaphy on tendinous healing and collagenous remodeling at the repair site.


Subject(s)
Plastic Surgery Procedures/veterinary , Tendons , Animals , Dogs , Orthopedic Procedures/veterinary , Tendons/surgery , Tensile Strength
14.
Am J Vet Res ; 82(12): 948-954, 2021 Nov 26.
Article in English | MEDLINE | ID: mdl-34714764

ABSTRACT

OBJECTIVE: To determine the effects of 2-, 4-, 6- and 8-strand suture repairs on the biomechanical properties of canine gastrocnemius tenorrhaphy constructs in an ex vivo model. SAMPLE: 56 cadaveric gastrocnemius musculotendinous units from 28 adult large-breed dogs. PROCEDURES: Tendons were randomly assigned to 4 repair groups (2-, 4-, 6- or 8-strand suture technique; n = 14/group). Following tenotomy, repairs were performed with the assigned number of strands of 2-0 polypropylene suture in a simple interrupted pattern. Biomechanical testing was performed. Yield, peak, and failure loads, the incidence of 1- and 3-mm gap formation, forces associated with gap formation, and failure modes were compared among groups. RESULTS: Yield, peak, and failure forces differed significantly among groups, with significantly greater force required as the number of suture strands used for tendon repair increased. The force required to create a 1- or 3-mm gap between tendon ends also differed among groups and increased significantly with number of strands used. All constructs failed by mode of suture pull-through. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that increasing the number of suture strands crossing the repair site significantly increases the tensile strength of canine gastrocnemius tendon repair constructs and their resistance to gap formation. Future studies are needed to assess the effects of multistrand suture patterns on tendon glide function, blood supply, healing, and long-term clinical function in dogs to inform clinical decision-making.


Subject(s)
Suture Techniques/veterinary , Sutures , Tendons , Animals , Dogs , Sutures/veterinary , Tendons/surgery
15.
Vet Surg ; 50(7): 1502-1509, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34405426

ABSTRACT

OBJECTIVE: To evaluate the influence of preconstructed effector loop location using a barbed unidirectional suture on leakage pressures following canine enterotomy closure. STUDY DESIGN: Randomized, experimental, cadaveric. ANIMALS OR SAMPLE POPULATION: Grossly normal jejunal segments from three canine cadavers. METHODS: Jejunal segments were harvested and randomly assigned based upon effector loop location from the beginning of the incisional line. Groups (n = 12/group) included 0 mm, 5 mm, 10 mm, 15 mm, and intact controls (n = 6/group), repaired using a 3-0 unidirectional barbed suture in a simple continuous pattern. Initial leakage pressure (ILP), maximum intraluminal pressure (MIP), repair time, and leakage location were recorded. RESULTS: Mean ILP for 0 mm group (24.42 ± 8.43 mmHg) was lower (p ≤ .001) compared to all experimental groups with ILP ~40% lower. There was no difference in MIP among experimental groups (p = .239). Repair time increased (p < .0001) as the distance of the effector loop increased ≥5 mm from the beginning of the incisional line. Leakage location differed among groups (p < .001) with leakage in the 0 mm group from the incisional line (75%), compared to leakage from predominantly from the suture holes in other groups, respectively. CONCLUSION: Effector loop location influenced ILP and leakage location. Effector loops placed at the beginning of the incisional line (0 mm) decreased ILP compared to loops placed at 5, 10, and 15 mm. CLINICAL SIGNIFICANCE: Effector loop location using a unidirectional barbed suture should be placed ≥5 mm from beginning of the incisional line for enterotomy closure. Further in vivo studies are necessary to determine the clinical significance of these findings.


Subject(s)
Digestive System Surgical Procedures , Sutures , Anastomosis, Surgical/veterinary , Animals , Digestive System Surgical Procedures/veterinary , Dogs , Pressure , Suture Techniques/veterinary , Sutures/veterinary
16.
Vet Surg ; 50(6): 1316-1325, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34228367

ABSTRACT

OBJECTIVE: To compare the biomechanical properties and gapping characteristics of four novel tenorrhaphy patterns in a canine flexor tendon model. STUDY DESIGN: Ex vivo, randomized, biomechanical study. SAMPLE POPULATION: Superficial digital flexor tendons of 60 forelimbs (30 dogs). METHODS: Each tendon was transected 25 mm distal to its musculotendinous junction prior to tenorrhaphy with 2-0 polypropylene. Repair patterns included the three-loop pulley (3LP, control), exposed double-cross-lock (ExDCrL), embedded double-cross-lock (EmDCrL), triple-circle-lock (TCiL), and Modified-Tang patterns (MTang) were randomly assigned to each experimental group (n = 12/group). Yield, peak, and failure loads, gap formation and failure modes were compared. RESULTS: Tendons repaired with ExDCrL (p < .0001), EmDCrL (p < .0001), and MTang (p < .0001) sustained yield, peak, and failure loads ~2.2x, ~2.0x, and ~1.9x, respectively, greater than those repaired with 3LP. Loads to 1 and 3 mm gapping were also higher for ExDCrL (p < .0001), EmDCrL (p < .0004), and MTang constructs (p < .0017) compared to 3LP. Although TCiL constructs sustained higher loads, their resistance to gap formation did not differ from that of 3LP repairs. Failure mode differed between groups (p < .0001), EmDCrL, ExDCrL, MTang, and TCiL constructs failing predominantly by suture breakage compared to 3LP repairs that failed by suture pull-through. CONCLUSION: Use of novel patterns ExDCrL, EmDCrL, and MTang improved resistance to loads and gap formation and were biomechanically superior compared to 3LP in healthy canine tendon repairs. CLINICAL SIGNIFICANCE: These results justify in vivo evaluation of ExDCrL, EmDCrL, or MTang pattern for tenorrhaphy in dogs.


Subject(s)
Dog Diseases , Tendon Injuries , Animals , Biomechanical Phenomena , Cadaver , Dogs , Random Allocation , Suture Techniques/veterinary , Sutures/veterinary , Tendon Injuries/surgery , Tendon Injuries/veterinary , Tensile Strength
17.
Vet Surg ; 50(5): 1128-1136, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33959989

ABSTRACT

OBJECTIVE: To determine the effect of a novel barbed suture pattern (NBSP) compared to a three-loop-pulley (3LP) with and without epitendinous suture (ES) augmentation on the biomechanical strength and gap formation of repaired canine tendons. STUDY DESIGN: Ex vivo, cadaveric, randomized, experimental study. SAMPLE POPULATION: Forty, adult superficial digital flexor tendons (SDFT). METHODS: SDFT were randomly assigned to one of four groups (n = 10/group). Sharp tenotomy was performed and repaired with 3LP, NBSP, 3LP + ES, and NBSP + ES. Constructs were tested to failure while evaluating yield, peak, and failure loads, loads at 1 and 3 mm gap formation, and failure mode. RESULTS: Constructs augmented with ES sustained 80% greater yield (p < .001), peak (p < .001), and failure (p < .001) loads, with no difference between 3LP + ES and NBSP + ES constructs regarding peak (p = .614), and failure forces (p = .865). Loads resulting in 1 and 3 mm gap formation were greater when constructs were augmented with an ES (p ≤ .003). Failure mode differed between groups (p < .001), occurring predominantly due to suture pull-through in 3LP and NBSP groups compared to tissue failure distant to the repair site in ES augmented constructs. CONCLUSION: Tendons repaired with the NBSP used in this study resisted similar forces as those repaired with 3LP. Augmentation with an ES improved the biomechanical properties of repaired constructs, including resistance to gap formation. CLINICAL RELEVANCE: The NBSP repair tested here may be advantageous over monofilament suture repair as it uses a similar-sized barbed core suture but eliminates the requirement for knot tying.


Subject(s)
Dog Diseases/surgery , Suture Techniques/veterinary , Tendon Injuries/veterinary , Tendons/surgery , Animals , Biomechanical Phenomena , Cadaver , Dogs , Forelimb , Plastic Surgery Procedures/veterinary , Sutures , Tendon Injuries/surgery , Tenotomy/veterinary , Tensile Strength
18.
Am J Vet Res ; 82(6): 510-515, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34032486

ABSTRACT

OBJECTIVE: To determine the effect of epitendinous suture (ES) caliber on the tensile strength of flexor tendon repairs in cadaveric specimens from dogs. SAMPLE: 60 cadaveric superficial digital flexor tendons (SDFTs) from 30 skeletally mature dogs. PROCEDURES: Specimens were randomly assigned to 5 suture caliber groups (n = 12 SDFTs/group). After sharp transection, SDFTs were repaired by placement of a simple continuous circumferential ES created with size-0, 2-0, 3-0, 4-0, or 5-0 polypropylene suture. Constructs were preloaded to 2 N and load tested to failure. Loads at yield, peak, and failure and mode of failure were compared among groups by statistical methods. RESULTS: Yield, peak, and failure loads for SDFT repair constructs were positively correlated with ES caliber and did not differ between the size-0 and 2-0 groups on pairwise comparisons. Yield load was significantly greater for size-0, 2-0, and 3-0 groups than for the 4-0 and 5-0 groups. Peak and failure loads were significantly greater for the size-0 and 2-0 groups than for the remaining groups. Most size-0 (12/12), 2-0 (12/12), and 3-0 (10/12) group constructs failed because of ES pull-through; several constructs in the 4-0 group (5/12) and most in the 5-0 group (11/12) failed because of ES breakage. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested size-0 and 2-0 sutures should be considered when placing an ES for flexor tendon repairs in dogs. However, in vivo studies are needed determine the effects of increasing ES caliber on clinical outcomes for dogs undergoing these procedures.


Subject(s)
Dog Diseases , Tendon Injuries , Animals , Biomechanical Phenomena , Cadaver , Dogs , Suture Techniques/veterinary , Sutures/veterinary , Tendon Injuries/surgery , Tendon Injuries/veterinary , Tendons/surgery , Tensile Strength
19.
Vet Surg ; 50(5): 1147-1156, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33942332

ABSTRACT

OBJECTIVE: To evaluate the effect of accessory tendon graft (ATG) augmentation as an adjunct to a core locking-loop (LL) and epitendinous suture (ES) repair in a gastrocnemius tendon (GT) model. STUDY DESIGN: Randomized, ex vivo, biomechanical. POPULATION: Twenty-two canine GT musculotendinous constructs. METHODS: GT repair constructs were randomly divided into two groups (n = 10/group). After transection, paired GT were repaired with LL + ES alone or with concurrent ATG augmentation. Yield, peak and failure loads, tensile loads required to create 1 and 3 mm gapping, and failure modes were evaluated. Four GT were used as intact controls for validation of testing methodology. ATG constructs were compared to LL + ES and control specimens. RESULTS: Yield (p < .0001), peak (p = .0001) and failure loads (p = .0003) were greater when ATG was used for repair. Greater force was required to cause 1 mm (p = .0001) and 3 mm (p = .0002) gap formation in the ATG group, however, the frequency of gap formation did not differ between groups. All repaired constructs failed exclusively by suture pull-through. CONCLUSION: Autologous ATG augmentation as an adjunct to primary GT repair increased yield, peak and failure forces by approximately 1.6×, 1.9×, 1.8× respectively and required 2.1× greater force to cause 1 and 3 mm formation respectively compared to LL + ES repairs alone. CLINICAL SIGNIFICANCE: ATG augmentation should be considered as an autologous method to support and strengthen the primary GT repair. These results justify studies to determine the effect of ATG on clinical function following graft harvest in dogs.


Subject(s)
Dog Diseases/surgery , Plastic Surgery Procedures/veterinary , Tendon Injuries/veterinary , Animals , Biomechanical Phenomena , Cadaver , Dogs , Hindlimb , Muscle, Skeletal/surgery , Orthopedic Procedures/veterinary , Suture Techniques/veterinary , Sutures/veterinary , Tendon Injuries/surgery , Tendons/surgery , Tensile Strength , Transplantation, Autologous/veterinary
20.
Vet Comp Orthop Traumatol ; 34(4): 248-256, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33792007

ABSTRACT

OBJECTIVE: This study aimed to evaluate the effect of increasing the number of suture strands traversing the transection site, level of suture purchase and depth of suture penetrance on the biomechanical properties of repaired gastrocnemius tendons. STUDY DESIGN: Thirty-eight adult cadaveric gastrocnemius tendons were randomized, transected and repaired with either two-, four- or six-strand locking multi-level repair. Tensile loads required to create a 1 and 3 mm gap, yield, peak and failure loads and failure mode were analysed. Significance was set at p < 0.05. RESULTS: Mean ± standard deviation yield, peak and failure force for six-strand repairs was 90.6 ± 22.1 N, 111.4 ± 15.2 N and 110.3 ± 15.1 N respectively. This was significantly greater compared with both four-strand (55.0 ± 8.9 N, 72.9 ± 7.8 N and 72.1 ± 8.2 N) and two-strand repairs (24.7 ± 8.3 N, 36.5 ± 6.0 N and 36.1 ± 6.3 N) respectively (p < 0.001). Occurrence of 3 mm gap formation was significantly less using six-strand repairs (p < 0.001). Mode of failure did not differ between groups with all repairs (36/36; 100%) failing by suture pull-through. CONCLUSION: Pattern modification by increasing the number of suture strands crossing the repair site, increasing points of suture purchase from the transection site and depth of suture penetrance is positively correlated with repair site strength while significantly reducing the occurrence of gap formation in a canine cadaveric model. Additional studies in vivo are recommended to evaluate their effect on tendinous healing, blood supply and glide resistance prior to clinical implementation.


Subject(s)
Dog Diseases , Lacerations , Animals , Biomechanical Phenomena , Cadaver , Dogs , Lacerations/surgery , Lacerations/veterinary , Suture Techniques/veterinary , Sutures , Tendons/surgery , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL
...