Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Infect Control Hosp Epidemiol ; 42(9): 1098-1104, 2021 09.
Article in English | MEDLINE | ID: mdl-33441207

ABSTRACT

BACKGROUND: Data on short-term peripheral intravenous catheter-related bloodstream infections per 1,000 peripheral venous catheter days (PIVCR BSIs per 1,000 PVC days) rates from Latin America are not available, so they have not been thoroughly studied. METHODS: International Nosocomial Infection Control Consortium (INICC) members conducted a prospective, surveillance study on PIVCR BSIs from January 2010 to March 2018 in 100 intensive care units (ICUs) among 41 hospitals, in 26 cities of 9 countries in Latin America (Argentina, Brazil, Colombia, Costa Rica, Dominican-Republic, Ecuador, Mexico, Panama, and Venezuela). The Centers for Disease Control and Prevention (CDC) National Health Safety Network (NHSN) definitions were applied, and INICC methodology and INICC Surveillance Online System software were used. RESULTS: In total, 10,120 ICU patients were followed for 40,078 bed days and 38,262 PVC days. In addition, 79 PIVCR BSIs were identified, with a rate of 2.06 per 1,000 PVC days (95% confidence interval [CI], 1.635-2.257). The average length of stay (ALOS) of patients without a PIVCR BSI was 3.95 days, and the ALOS was 5.29 days for patients with a PIVCR BSI. The crude extra ALOS was 1.34 days (RR, 1.33; 95% CI, 1.0975-1.6351; P = .040).The mortality rate in patients without PIVCR BSI was 3.67%, and this rate was 6.33% in patients with a PIVCR BSI. The crude extra mortality was 1.70 times higher. The microorganism profile showed 48.5% gram-positive bacteria (coagulase-negative Staphylococci 25.7%) and 48.5% gram-negative bacteria: Acinetobacter spp, Escherichia coli, and Klebsiella spp (8.5% each one), Pseudomonas aeruginosa (5.7%), and Candida spp (2.8%). The resistances of Pseudomonas aeruginosa were 0% to amikacin and 50% to meropenem. The resistance of Acinetobacter baumanii to amikacin was 0%, and the resistance of coagulase-negative Staphylococcus to oxacillin was 75%. CONCLUSIONS: Our PIVCR BSI rates were higher than rates from more economically developed countries and were similar to those of countries with limited resources.


Subject(s)
Cross Infection , Sepsis , Argentina , Brazil , Catheters , Colombia , Costa Rica , Cross Infection/epidemiology , Dominican Republic/epidemiology , Ecuador/epidemiology , Humans , Intensive Care Units , Latin America/epidemiology , Mexico , Panama , Prospective Studies , Venezuela
2.
Infect Control Hosp Epidemiol ; 39(4): 445-451, 2018 04.
Article in English | MEDLINE | ID: mdl-29427997

ABSTRACT

OBJECTIVE To analyze the impact of the International Nosocomial Infection Control Consortium (INICC) Multidimensional Approach (IMA) and the INICC Surveillance Online System (ISOS) on central line-associated bloodstream infection (CLABSI) rates in 14 intensive care units (ICUs) in Argentina from January 2014 to April 2017. DESIGN This prospective, pre-post surveillance study of 3,940 ICU patients was conducted in 11 hospitals in 5 cities in Argentina. During our baseline evaluation, we performed outcome and process surveillance of CLABSI applying Centers for Disease Control and Prevention/National Health Safety Network (CDC/NHSN) definitions. During the intervention, we implemented the IMA through ISOS: (1) a bundle of infection prevention practice interventions, (2) education, (3) outcome surveillance, (4) process surveillance, (5) feedback on CLABSI rates and consequences, and (6) performance feedback of process surveillance. Bivariate and multivariate regression analyses were performed using a logistic regression model to estimate the effect of the intervention on the CLABSI rate. RESULTS During the baseline period, 5,118 CL days and 49 CLABSIs were recorded, for a rate of 9.6 CLABSIs per 1,000 central-line (CL) days. During the intervention, 15,659 CL days and 68 CLABSIs were recorded, for a rate of 4.1 CLABSIs per 1,000 CL days. The CLABSI rate was reduced by 57% (incidence density rate: 0.43; 95% confidence interval, 0.34-0.6; P<.001). CONCLUSIONS Implementing IMA through ISOS was associated with a significant reduction in the CLABSI rate in ICUs in Argentina. Infect Control Hosp Epidemiol 2018;39:445-451.


Subject(s)
Bacteremia , Catheter-Related Infections , Central Venous Catheters/adverse effects , Cross Infection , Infection Control , Argentina/epidemiology , Bacteremia/epidemiology , Bacteremia/etiology , Bacteremia/prevention & control , Catheter-Related Infections/epidemiology , Catheter-Related Infections/etiology , Catheter-Related Infections/prevention & control , Cross Infection/epidemiology , Cross Infection/prevention & control , Humans , Incidence , Infection Control/methods , Infection Control/organization & administration , Outcome and Process Assessment, Health Care , Program Evaluation/statistics & numerical data , Risk Factors
3.
Am J Infect Control ; 46(6): 674-679, 2018 06.
Article in English | MEDLINE | ID: mdl-29329916

ABSTRACT

BACKGROUND: To analyze the impact of the International Nosocomial Infection Control Consortium (INICC) multidimensional approach (IMA) on ventilator-associated pneumonia (VAP) rates in 11 hospitals within 5 cities of Argentina from January 2014-April 2017. METHODS: A multicenter, prospective, before-after surveillance study was conducted through the use of International Nosocomial Infection Control Consortium Surveillance Online System. During baseline, we performed outcome surveillance of VAP applying the definitions of the Centers for Disease Control andPrevention's National Healthcare Safety Network. During intervention, we implemented the IMA, which included a bundle of infection prevention practice interventions, education, outcome surveillance, process surveillance, feedback on VAP rates and consequences, and performance feedback of process surveillance. Bivariate and multivariate regression analyses were performed using a logistic regression model to estimate the effect of the intervention. RESULTS: We recorded 3,940 patients admitted to 14 intensive care units. At baseline, there were 19.9 VAPs per 1,000 mechanical ventilator (MV)-days-with 2,920 MV-days and 58 VAPs, which was reduced during intervention to 9.4 VAPs per 1,000 MV-days-with 9,261 MV-days and 103 VAPs. This accounted for a 52% rate reduction (incidence density rate, 0.48; 95% confidence interval, 0.3-0.7; P .001). CONCLUSIONS: Implementing the IMA was associated with significant reductions in VAP rates in intensive care units within Argentina.


Subject(s)
Cross Infection/epidemiology , Cross Infection/prevention & control , Infection Control/methods , Intensive Care Units , Pneumonia, Ventilator-Associated/epidemiology , Pneumonia, Ventilator-Associated/prevention & control , Adult , Aged , Aged, 80 and over , Argentina/epidemiology , Cities/epidemiology , Female , Hospitals , Humans , Incidence , Male , Middle Aged , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL