Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
Ther Drug Monit ; 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38648663

ABSTRACT

BACKGROUND: Cholestasis commonly occurs after orthotopic liver transplantation. It can be extrahepatic because of mechanical obstruction or intrahepatic because of various causes. During cholestasis episodes, blood concentrations of tacrolimus (TAC) metabolites may increase, potentially affecting TAC concentrations measured by immunoassays. This study aimed to simultaneously evaluate the analytical performance of 2 TAC immunoassays, a quantitative microsphere system (QMS) immunoassay, and chemiluminescence microparticle immunoassay, using liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a reference method in liver transplant recipients. METHODS: This single-center study included 265 patients who underwent orthotopic liver transplantation. In total, 942 blood samples were collected. TAC trough concentrations were measured using LC-MS/MS and 2 immunoassays in parallel. The plasma concentrations of conjugated bilirubin were measured in all samples. The results were analyzed using Bland-Altman plots and Passing-Bablok regressions. RESULTS: The Bland-Altman plot analysis showed that the TAC QMS immunoassay has a significant bias (+37%) compared with LC-MS/MS, and this bias was higher in patients with cholestasis with hyperbilirubinemia (≤+70% in patients with conjugated bilirubin >150 µmol/L). In comparison, the chemiluminescence microparticle immunoassay showed acceptable analytical performance in patients with hyperbilirubinemia (bias <10%). CONCLUSIONS: In agreement with previous findings, the TAC QMS immunoassay showed a positive bias compared with LC-MS/MS. This bias is remarkably high in patients with cholestasis and hyperbilirubinemia, suggesting the cross-reactivity of TAC metabolites with the monoclonal antibody used in the QMS immunoassay.

2.
Ann Pharm Fr ; 82(3): 575-583, 2024 May.
Article in French | MEDLINE | ID: mdl-38340805

ABSTRACT

OBJECTIVES: In a context of heparin shortage, we studied the wasted quantities in three intensive care units (ICU) of a university hospital where two electric syringe pump (ESP) heparin protocols coexist (20,000UI/48mL used in the cardiology ICU and 25,000UI/50mL use in the medical and surgical ICUs). METHOD: We performed a prospective observational study of patients treated with heparin ESP. We collected the information recorded in the prescription software connected to the ESP (dosage, start time, infusion rate, interruption times, date and time of end of treatment). We observed the ESPs, noted the time of start written on the label and the quantity remaining, and questioned nurses about the constraints that lead for changing the ESPs. RESULTS: Between 23/03/23 and 19/05/23, 164 vials of 25,000UI/5mL were used. The wasted quantity was equivalent 42 vials: 18 vials (43%) of treatment stopped, nurses practices such as changing the ESP in advance 6 vials (14%), application of the rule "discard the ESP 24hours after preparation" 9 vials (21.5%) and 9 vials (21.5%) corresponding to the 45mL discarded for the 45 ESP prepared in the cardiology ICU. CONCLUSION: More than a quarter of the heparin purchased is wasted. The results should lead to policy decisions concerning the medications supply chain, i.e. abandoning the 20,000UI/48mL protocol, supply of ready to use heparin syringes by industry or by the pharmacy. It is essential that these data be fed back to nurses' teams, in order to gather their suggestions before considering any changes of their practices.


Subject(s)
Heparin , Pharmacy , Humans , Heparin/adverse effects , Hospitals, University , Intensive Care Units , Prospective Studies
3.
Ann Pharm Fr ; 82(2): 359-368, 2024 Mar.
Article in French | MEDLINE | ID: mdl-37879563

ABSTRACT

OBJECTIVES: To determine whether hospital computerised physician order entry (CPOE) systems contribute to securing intravenous potassium chloride (KCl) prescriptions with reference to the recommendations issued by French healthcare agencies. METHODS: We sent a questionnaire to the members of the Association pour le Digital et l'Information en Pharmacie. RESULTS: More than three quarters of the 84 responses received involving 23 CPOE systems indicate that it is possible to: prescribe an ampoule of concentrated potassium chloride 10% 10mL intravenously without any diluents (80%); prescribe 4g of KCl in a bag of 500mL of NaCl 0,9% (98%); prescribe a solution that contains 6 grams of KCl per liter (94%); prescribe the administration of an injectable ampoule orally by means of a free text comment (83%). Nearly half of the responses indicate that it is possible to prescribe: concentrated KCl ampoules as administration solvent (50%); an injectable vial to be administered by oral route (52%). CONCLUSION: At least 23 hospital CPOE systems are unable to secure the prescriptions of injectable KCl. This finding lifts the veil on an unthought, namely the role of CPOE systems in securing high-risk medications. In order to solve this problem, it should be mandatory that health information technology vendors pay particular attention to these drugs. With regard to injectable KCl, the utilisation of a dilution vehicle, maximum concentration and maximum infusion flow rate are the first four constraints to be satisfied.


Subject(s)
Medical Order Entry Systems , Potassium , Humans , Potassium Chloride , Medication Errors , Hospitals
4.
Ann Cardiol Angeiol (Paris) ; 72(4): 101645, 2023 Oct.
Article in French | MEDLINE | ID: mdl-37660586

ABSTRACT

OBJECTIVES: Several protocols for administering heparin by electric syringe pump can coexist within the same hospital. This puts patients at risk of medication errors. In our hospital trust, two preparation protocols coexist (20000UI/48mL and 25000UI/50mL). The objective is to relate the work carried out with prescribers and nurses to retain only one protocol. METHODS: We questioned prescribers and nurses about the differences between the two protocols in terms of the simplicity of implementation and the risk of error to which nurses are exposed when preparing the syringe. Contextual information (heparin shortage, waste) was given in order to support the answers. RESULTS: According to the 96 nurses and 82 prescribers who responded, the protocol to use is 25000IU/50mL for 98% and 83% of them respectively. The 20000IU/48mL protocol was considered the riskiest due to the possibility of mistakenly collecting 5mL instead of the required 4mL. Given the heparin shortage, the waste inherent to the 20000IU/48mL protocol reinforced this choice. CONCLUSIONS: The consultation of nurses and prescribers allowed the choice of a protocol with very strong agreement. This work also brought to light what appears to be a medical misconception, namely that the non-concerted choice by physicians of a mode of administration of a drug can put nurses in a situation to make preparation errors more frequently. This emphasizes that nurses must be stakeholders in the decision-making processes that affect their practice.

6.
Ann Pharm Fr ; 81(6): 1054-1071, 2023 Nov.
Article in French | MEDLINE | ID: mdl-37356663

ABSTRACT

Prescribing errors related to computerized physician order entry are current and may have serious consequences for patients. They can be detected by pharmacists during prescriptions analysis and lead to pharmacist's interventions. In France, few monocentric studies have studied Pharmacist Interventions triggered by prescribing errors identified as System-Related Errors (PISREs) in French hospitals. However, their respective analysis method prevent any comparison between computerized physician order entry systems in order to identify the safest and rule out the most dangerous. A computerized physician prescribing error related to the software is characterized by its causes, consequences and mechanism of occurrence. US researchers have developed and validated a tool to classify and illustrate these three characteristics. The objectives of this article are to present this tool, to propose a French adaptation and to describe the perspectives analyze and understand prescription errors related to computerized physician order entry based on data of Act-IP©. The adaptation was performed using PISREs extracted from the Act-IP© observatory of the French Society of Clinical Pharmacy. Each item of the codification is illustrated with an example of PI. We are considering a training plan in order to allow wide use of this tool. Once adopted this tool, the next step will be to organize a prospective multicenter study including as many computerized prescription order entry systems as possible. The aim of this study will be identifying the safest systems. Consequently, it will then be possible to have arguments to qualify the most dangerous and thus propose their withdrawal from the market.

7.
Int J Med Inform ; 175: 105091, 2023 07.
Article in English | MEDLINE | ID: mdl-37182411

ABSTRACT

OBJECTIVE: Two tools are currently available in the literature to evaluate the usability of medication alert systems, the instrument for evaluating human factors principles in medication-related decision support alerts (I-MeDeSA) and the tool for evaluating medication alerting systems (TEMAS). This study aimed to compare their convergent validity, perceived usability, usefulness, strengths, and weaknesses, as well as users' preferences. METHOD: To evaluate convergent validity, two experts mapped TEMAS' items against I-MeDeSA's items with respect to the usability dimensions they target. To assess perceived usability, usefulness, strengths, and weaknesses of both tools, staff with expertise in their medication alerting system were asked to use French versions of the TEMAS and I-MeDeSA. After the use of each tool, participants were asked to complete the System Usability Scale (SUS) and answer questions about the understandability and usefulness of each tool. Finally, participants were asked to name their preferred tool. Numeric scores were statistically compared. Free-text responses were analyzed using an inductive approach. RESULTS: Forty-five participants from 10 hospitals took part in the study. In terms of convergent validity, I-MeDeSA focuses more on the usability of the graphical user interface while TEMAS considers a wider range of usability principles. Both tools have a fair level of perceived usability (I-MeDeSA' SUS score = 61.85 and TEMAS' SUS score = 62.87), but results highlight that revisions are necessary to both tools to improve their usability. Participants found TEMAS more useful than I-MeDeSA (t = -3.63, p =.005) and had a clear preference for TEMAS to identify problems in formative evaluation (39 of 45; 0.867, p <.001) and to compare the usability of alert systems during the procurement process (36 of 45; 0.8, p <.001). CONCLUSIONS: The TEMAS is perceived as more useful and is preferred by participants. The I-MeDeSA seems more relevant for quick evaluations that focus on the graphical user interface. The TEMAS seems to be more suitable for in-depth usability evaluations of alert systems. Even if both tools are perceived to be equally usable, they suffer from wording, instructional, and organizational problems that hinder their use. The results of this study will be used to improve the design of I-MeDeSA and TEMAS.


Subject(s)
Decision Support Systems, Clinical , Medical Order Entry Systems , Humans , User-Computer Interface
9.
BMJ Open ; 11(10): e045778, 2021 10 11.
Article in English | MEDLINE | ID: mdl-34635512

ABSTRACT

OBJECTIVES: Computerised physician order entry (CPOE) systems facilitate the review of medication orders by pharmacists. Reports have emerged that show conception flaws or the misuse of CPOE systems generate prescribing errors. We aimed to characterise pharmacist interventions (PIs) triggered by prescribing errors identified as system-related errors (PISREs) in French hospitals. DESIGN: This was a cross-sectional observational study based on PIs prospectively documented in the Act-IP observatory database from January 2014 to December 2018. SETTING: PISREs from 319 French computerised healthcare facilities were analysed. PARTICIPANTS: Among the 319 French hospitals, 232 (72.7%) performed SRE interventions, involving 652 (51%) pharmacists. RESULTS: Among the 331 678 PIs recorded, 27 058 were qualified as due to SREs (8.2%). The main drug-related problems associated with PISREs were supratherapeutic (27.5%) and subtherapeutic dosage (17.2%), non-conformity with guidelines/contraindications (22.4%) and improper administration (17.9%). The PI prescriber acceptation rate was 78.9% for SREs vs 67.6% for other types of errors. The PISRE ratio was estimated relative to the total number of PIs. Concerning the certification status of CPOE systems, the PISRE ratio was 9.4% for non-certified systems vs 5.5% for certified systems (p<0.001). The PISRE ratio for senior pharmacists was 9.2% and that for pharmacy residents 5.4% (p<0.001). Concerning prescriptions made by graduate prescribers and those made by residents, the PISRE ratio was 8.4% and 7.8%, respectively (p<0.001). CONCLUSION: Computer-related prescribing errors are common. The PI acceptance rate by prescribers was higher than that observed for PIs that were not CPOE related. This suggests that physicians consider the potential clinical consequences of SREs for patients to be more frequently serious than interventions unrelated to CPOE. CPOE medication review requires continual pharmacist diligence to catch these errors. The significantly lower PISRE ratio for certified software should prompt patient safety agencies to undertake studies to identify the safest software and discard software that is potentially dangerous.


Subject(s)
Medical Order Entry Systems , Cross-Sectional Studies , Drug Prescriptions , Hospitals , Humans , Medication Errors , Pharmacists
10.
Eur J Hosp Pharm ; 28(4): 193-200, 2021 07.
Article in English | MEDLINE | ID: mdl-33883205

ABSTRACT

OBJECTIVES: Clinical pharmacists' interventions (PIs) are an important element in ensuring good pharmaceutical care. We aimed to develop and validate a comprehensive multidimensional tool for assessing the potential impact of PIs for daily practice of medication review. METHODS: Experts of the French Society of Clinical Pharmacy (SFPC) developed the CLinical, Economic and Organisational (CLEO) tool, consisting of three independent dimensions concerning clinical, economic and organisational impact. They were asked to analyse 30 scenarios of PIs, and re-rated 10 PIs with a washout of 1 month (internal validation). Then, seven external experts not involved in the development of the tool rated 60 scenarios collected when using the CLEO in daily practice. Inter- and intra-rater reliabilities were determined by calculation of the intra-class correlation (ICCA,1). Users' satisfaction and acceptability of the tool were assessed on a 7-level Likert scale with a 17-item questionnaire. RESULTS: For internal reliability, the inter-rater reliability for the CLEO tool was good for clinical dimensions (ICCA,1=0.693), excellent for economic dimensions (ICCA,1=0.815) and fair for organisational dimensions (ICCA,1=0.421); and the intra-rater reliability was good for clinical dimensions (ICCA,1=0.822), excellent for economic dimensions (ICCA,1=0.918) and good for organisational dimensions (ICCA,1=0.738). For external reliability, the inter-rater reliability was good for clinical dimensions (ICCA,1=0.649), excellent for economic dimensions (ICCA,1=0.814) and fair for organisational dimensions (ICCA,1=0.500). CLEO was viewed as relevant (mean±SD 4.93±1.27), acceptable (4.81±1.78), practicable (5.56±1.45) and precise (5.38±1.47). CONCLUSIONS: CLEO is a comprehensive tool assessing clinical, economic and organisational impacts of PIs which has been developed, validated and was reliable and feasible for use in routine clinical practice.


Subject(s)
Pharmacists , Pharmacy Service, Hospital , Humans , Reproducibility of Results , Surveys and Questionnaires
11.
J Clin Pharm Ther ; 46(4): 1041-1045, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33629438

ABSTRACT

WHAT IS KNOWN AND OBJECTIVE: Proton pump inhibitors (PPI) have become essential in the management of upper gastrointestinal disorders, yet they are prescribed without an indication in up to 89% of cases and the number of prescribed PPIs is on the rise. A working group developed several multifaceted strategies in our multihospital trust to curb inappropriate PPI use. We describe herein these strategies and assess their impact on PPI consumption in a hospital belonging to this trust. METHODS: From 2012 to 2019, our actions included the publication and presentation of a review of emergent PPI side effects, the development of an appropriate use leaflet, medication audits, journal club meetings, and prescription analysis. We considered that a decrease in PPI consumption could be a relevant surrogate criterion for the appropriation and acceptance of these interventions; this was assessed from 2012 to 2019 and expressed as defined daily dose (DDD)/1000 patient-days. RESULTS AND DISCUSSION: There was a clear downward trend in the consumption of PPIs, both in medical and surgical wards. The overall PPI use decreased by 17.1% (from 566 to 468 DDD/1000 patient-days). IV PPI consumption dropped by 37.7% (from 146 to 91 DDD/1000 patient-days), while oral PPIs consumption decreased by 10% (from 420 to 378 DDD/1000 patient-days). WHAT IS NEW AND CONCLUSION: Sustained strategies aimed at curbing PPI overprescribing led to a sustained decrease in PPI consumption in our hospital. This decrease encourages us to pursue this strategy and to diversify our actions.


Subject(s)
Academic Medical Centers/organization & administration , Inappropriate Prescribing/prevention & control , Pharmacy Service, Hospital/organization & administration , Practice Patterns, Physicians'/statistics & numerical data , Proton Pump Inhibitors/administration & dosage , Humans
12.
Rech Soins Infirm ; (141): 78-86, 2020 06.
Article in French | MEDLINE | ID: mdl-32988194

ABSTRACT

Despite its proven dangers, the ward stock drug distribution system predominates in French hospitals. This system allows 12 million injectable ampoules of concentrated potassium chloride to circulate uncontrolled each year. Such a situation is absurd for the following reasons : 1) injected by mistake, concentrated potassium kills within seconds ; 2) the true incidence of potassium-related fatalities and incidents is unknown ; 3) fatal intravenous injection of potassium produces no specific anatomical changes and subtle, if any, findings at autopsy ; 4) it is used for capital punishment by lethal injection in various countries ; and 5) healthcare worker serial killers benefit from the fact that potassium is not identifiable in post-mortem examinations and that investigations to find the murderer are complex and of uncertain outcome. Other medications classed as high-risk have similar characteristics to those of concentrated potassium solutions. Injectable potassium can therefore be regarded as emblematic of the lack of safety of the drug use process in French hospitals. The priority measure to protect patients from this deadly risk is to remove these drugs from uncontrolled ward stocks and to provide premixed potassium solutions. Evidence of the increased safety of the unit dose drug dispensing system should compel health policy makers to systematically implement it, thus bringing the drug use process into compliance with existing French and European regulations.


Subject(s)
Patient Safety/standards , Potassium Chloride/poisoning , Drug and Narcotic Control , France , Hospitals , Humans , Injections , Potassium Chloride/administration & dosage , Potassium Chloride/chemistry
13.
Clin Drug Investig ; 40(10): 897-899, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32779119

ABSTRACT

During the ongoing pandemic of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), more attention should be paid to the balance of risks and benefits associated with proton pump inhibitors for the following reasons. One of the main functions of gastric juice is to inactivate swallowed microorganisms, thereby inhibiting infectious agents from reaching the intestine. Studies have documented that proton pump inhibitors are a risk factor for rotavirus, influenza virus, norovirus, and Middle East respiratory syndrome coronavirus infections, and are associated with an increased risk of acute gastroenteritis during periods of highest circulation of enteric viruses. In light of the evidence for gastrointestinal infection implying a fecal-oral transmission of SARS-CoV-2 and given the magnitude of the SARS-CoV-2/coronavirus disease 2019 pandemic, associated with the widespread misuse of proton pump inhibitors, this suggests that we should not rule out the hypothesis that patients treated with proton pump inhibitors may be more at risk of being infected by SARS-CoV-2.


Subject(s)
Betacoronavirus/drug effects , Coronavirus Infections/epidemiology , Pneumonia, Viral/epidemiology , Proton Pump Inhibitors/adverse effects , Betacoronavirus/physiology , COVID-19 , Coronavirus Infections/chemically induced , Gastric Acid/physiology , Humans , Middle East Respiratory Syndrome Coronavirus/drug effects , Middle East Respiratory Syndrome Coronavirus/physiology , Pandemics , Pneumonia, Viral/chemically induced , Risk Factors , SARS-CoV-2
14.
Rech Soins Infirm ; 141(2): 78-86, 2020.
Article in French | MEDLINE | ID: mdl-35724035

ABSTRACT

Despite its proven dangers, the ward stock drug distribution system predominates in French hospitals. This system allows 12 million injectable ampoules of concentrated potassium chloride to circulate uncontrolled each year. Such a situation is absurd for the following reasons : 1) injected by mistake, concentrated potassium kills within seconds ; 2) the true incidence of potassium-related fatalities and incidents is unknown ; 3) fatal intravenous injection of potassium produces no specific anatomical changes and subtle, if any, findings at autopsy ; 4) it is used for capital punishment by lethal injection in various countries ; and 5) healthcare worker serial killers benefit from the fact that potassium is not identifiable in post-mortem examinations and that investigations to find the murderer are complex and of uncertain outcome. Other medications classed as high-risk have similar characteristics to those of concentrated potassium solutions. Injectable potassium can therefore be regarded as emblematic of the lack of safety of the drug use process in French hospitals. The priority measure to protect patients from this deadly risk is to remove these drugs from uncontrolled ward stocks and to provide premixed potassium solutions. Evidence of the increased safety of the unit dose drug dispensing system should compel health policy makers to systematically implement it, thus bringing the drug use process into compliance with existing French and European regulations.

16.
Soins ; 63(827): 10-14, 2018.
Article in French | MEDLINE | ID: mdl-30008357

ABSTRACT

The packaging of the medication and the writing on the label can be the cause of medication errors. Errors in the intake of sodium chloride and potassium chloride have notably been due to the fact that the label of the infusion solute did not explicitly indicate the quantities present in the 500 mL and 1 000 mL bottles. Moreover, the meaning of the description comprising the term 'q.s.p. 1 000 mL' was not known by some of the nursing staff. These two factors, combined with the possibility of prescribing predefined order sets, have led to medication errors which have given rise to a study of how practices can be improved.


Subject(s)
Medical Order Entry Systems , Medication Errors/prevention & control , Drug Labeling , France , Humans , Patient Safety
18.
Res Social Adm Pharm ; 13(6): 1184-1185, 2017 11.
Article in English | MEDLINE | ID: mdl-27888092

ABSTRACT

Over the past 25 years in various countries, researchers have developed tools for recording pharmacist's interventions (PIs) and observational databases aimed at the exhaustive collection of these interventions. The large amount of published data contrasts strikingly with the fact that little attention has been paid to defining the different types of PIs from a theoretical point of view. Whatever the paper we read on this topic, each PI is presented as necessary and appropriate. We suggest this customary approach is biased and that the reality is somewhat more subtle. In order to better reflect the real world, we propose a new approach to the classification of PIs that is based on whether they are present or absent in observational databases, and we explain how to identify the absent ones. Present and absent PIs can be subdivided in two additional categories: appropriate and inappropriate ones. This additional classification should encourage pharmacists to critically examine and evaluate their practice and subsequently improve their ability to identify drug related problems in clinical practice.


Subject(s)
Documentation/classification , Pharmacists/organization & administration , Professional Role , Databases, Factual , Humans
19.
Transplantation ; 100(12): 2671-2681, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27547868

ABSTRACT

BACKGROUND: Doppler ultrasound (DUS) arterial abnormalities (DAA) after orthotopic liver transplantation (OLT) often represent a sign of hepatic artery (HA) complication (HAC). The standard management of DAA involves computed tomographic angiography (CTA) followed by invasive vascular intervention (IVI) or observation. We evaluated the contribution of systemic vasodilators (SVD) to the management of DAA after OLT. METHODS: Between 2005 and 2015, 91 of 514 OLT recipients developed DAA (defined by HA resistive index [HARI] <0.5) and received oral SVDs. Doppler ultrasound was performed 2 days later, and patients were assigned to 3 groups accordingly: the normalization group (HARI >0.5), improvement group (HARI increase of >0.1 but value <0.5), or nonresponse group. We analyzed the contribution of this strategy to predict clinically significant HAC, defined as thrombosis or HAC requiring IVI. RESULTS: A clinically significant HAC (4 thromboses, 35 HACs requiring IVI) was found in 2.9% (n = 1/34), 32.1% (n = 9/28), and 100% (n = 29/29) of patients in the normalization, improvement, and nonresponse groups, respectively (P < 0.001). On multivariate analysis, absence of HARI normalization after SVD and time to DAA longer than 30 days were associated with clinically significant HAC. Specificity and accuracy of DUS after SVD increased from 88.1% to 95.1% and from 88.9% to 95.1% (P < 0.001), without altering its sensitivity (97.7% vs 95.5%, P = 1.000). CONCLUSIONS: The use of SVD improves the diagnostic performance of DUS for clinically significant HAC after OLT. It allows identifying patients at low risk for HAC, for whom CTA could be avoided, and helps choosing between observation and IVI in patients with inconclusive CTA.


Subject(s)
Liver Failure/diagnostic imaging , Liver Failure/surgery , Liver Transplantation , Vasodilator Agents/therapeutic use , Adult , Anastomosis, Surgical , Angiography , Arteries/pathology , Computed Tomography Angiography , Female , Hepatic Artery/diagnostic imaging , Hepatic Artery/pathology , Humans , Male , Middle Aged , Multivariate Analysis , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Thrombosis/diagnostic imaging , Treatment Outcome , Ultrasonography, Doppler , Vascular Diseases/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...