Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Publication year range
1.
Bioing fís med cuba ; 5(1)feb.-abr. 2004. ilus, mapas, graf
Article in Spanish | CUMED | ID: cum-26123

ABSTRACT

Se desarrolló el software EMG Workplace para la exploración electroneuromiográfica con el equipo Neuronica 4. Este sistema permite la evaluación de la integridad funcional del aparato neuromuscular por medio de las técnicas de electromiografía, estudios de conducción nerviosa, Onda F, Reflejo H, Estimulación Nerviosa Repetitiva y Reflejo de Parpadeo, los cuales constituyen un poderoso instrumento para la detección de las enfermedades neuromusculares. En su desarrollo se utilizaron todas las facilidades que ofrece el lenguaje de programación Delphi, con el propósito de obtener un producto final de gran utilidad y sencillo en su manejo. El sistema incluye varias aplicaciones que se corresponden con las técnicas electroneuromiográficas más utilizadas en la clínica. Presenta las mismas posibilidades que otros equipos de la competencia y nuevas facilidades que son muy útiles para la presentación, procesamiento y almacenamiento de la información. EMGWorkplace hace más completo el trabajo con elelectromiógrafo cubano Neuronica 4. Sustituye el software desarrollado hace más de una década y que hoy en día no puede ejecutarse sobre este equipo, y lo pone a la altura de los equipos más avanzados en este campo(AU)


Subject(s)
Software , Electromyography , Neural Conduction , Neuromuscular Diseases
2.
Clin Neurophysiol ; 110(3): 390-6, 1999 Mar.
Article in English | MEDLINE | ID: mdl-10363760

ABSTRACT

OBJECTIVE: The 2D VEPs to pattern reversal (PR) and LED goggle were studied in order to obtain a stable parameter for the functional assessing of posterior visual pathways regardless of the stimulus type used. DESIGN AND METHODS: Apex c latency, bc segment amplitude (V), and bc vector orientation angle (theta) in voltage space were computed from VEPs recorded in 50 normal human beings and two patients with left posterior brain lesions, in an orthogonal Fpz-Oz and T3-T4 montage and displayed as a two channel Lissajous' trajectory. The effects of stimulus type and stimulated eye were analyzed in the normal group by a two-way ANOVA. RESULTS: The stimulated eye had no effect on any parameter. Apex c latency was slightly longer, and V was greater and more variable in the responses to goggle stimuli, but there was no significant difference in theta, oriented to mid-occipital scalp with very low variability for both stimulus types. The patients showed significant deviations of theta towards the affected hemisphere. CONCLUSIONS: The bc vector orientation (theta) is a stable parameter for the evaluation of the posterior visual pathways using both pattern reversal and LED stimuli, specially the latter, useful in unconscious or uncooperative patients.


Subject(s)
Evoked Potentials, Visual/physiology , Pattern Recognition, Automated , Adolescent , Adult , Brain/physiology , Brain Mapping , Electroencephalography , Female , Humans , Male , Middle Aged , Photic Stimulation
SELECTION OF CITATIONS
SEARCH DETAIL
...