Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
Add more filters










Publication year range
1.
Ann Biomed Eng ; 2024 May 17.
Article in English | MEDLINE | ID: mdl-38758460

ABSTRACT

The Circle of Willis (CoW) is a ring-like network of blood vessels that perfuses the brain. Flow in the collateral pathways that connect major arterial inputs in the CoW change dynamically in response to vessel narrowing or occlusion. Vasospasm is an involuntary constriction of blood vessels following subarachnoid hemorrhage (SAH), which can lead to stroke. This study investigated interactions between localization of vasospasm in the CoW, vasospasm severity, anatomical variations, and changes in collateral flow directions. Patient-specific computational fluid dynamics (CFD) simulations were created for 25 vasospasm patients. Computed tomographic angiography scans were segmented capturing the anatomical variation and stenosis due to vasospasm. Transcranial Doppler ultrasound measurements of velocity were used to define boundary conditions. Digital subtraction angiography was analyzed to determine the directions and magnitudes of collateral flows as well as vasospasm severity in each vessel. Percent changes in resistance and viscous dissipation were analyzed to quantify vasospasm severity and localization of vasospasm in a specific region of the CoW. Angiographic severity correlated well with percent changes in resistance and viscous dissipation across all cerebral vessels. Changes in flow direction were observed in collateral pathways of some patients with localized vasospasm, while no significant changes in flow direction were observed in others. CFD simulations can be leveraged to quantify the localization and severity of vasospasm in SAH patients. These factors as well as anatomical variation may lead to changes in collateral flow directions. Future work could relate localization and vasospasm severity to clinical outcomes like the development of infarct.

2.
Ann Biomed Eng ; 52(6): 1763-1778, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38517620

ABSTRACT

Patients with advanced heart failure are implanted with a left ventricular assist device (LVAD) as a bridge-to-transplantation or destination therapy. Despite advances in pump design, the risk of stroke remains high. LVAD implantation significantly alters intraventricular hemodynamics, where regions of stagnation or elevated shear stresses promote thrombus formation. Third generation pumps incorporate a pulsatility mode that modulates rotational speed of the pump to enhance in-pump washout. We investigated how the timing of the pulsatility mode with the cardiac cycle affects intraventricular hemodynamic factors linked to thrombus formation. Computational fluid dynamics simulations with Lagrangian particle tracking to model platelet behavior in a patient-specific left ventricle captured altered intraventricular hemodynamics due to LVAD implantation. HeartMate 3 incorporates a pulsatility mode that modulates the speed of the pump every two seconds. Four different timings of this pulsatility mode with respect to the cardiac cycle were investigated. A strong jet formed between the mitral valve and inflow cannula. Blood stagnated in the left ventricular outflow tract beneath a closed aortic valve, in the near-wall regions off-axis of the jet, and in a large counterrotating vortex near the anterior wall. Computational results showed good agreement with particle image velocimetry results. Synchronization of the pulsatility mode with peak systole decreased stasis, reflected in the intraventricular washout of virtual contrast and Lagrangian particles over time. Temporal synchronization of HeartMate 3 pulsatility with the cardiac cycle reduces intraventricular stasis and could be beneficial for decreasing thrombogenicity.


Subject(s)
Heart-Assist Devices , Hemodynamics , Models, Cardiovascular , Humans , Heart Ventricles , Computer Simulation , Thrombosis/physiopathology , Heart Failure/physiopathology
3.
ASAIO J ; 69(6): 533-543, 2023 06 01.
Article in English | MEDLINE | ID: mdl-36881637

ABSTRACT

Thromboembolic events remain a common complication for left ventricular assist device (LVAD) patients. To prevent in-pump thrombosis, third-generation LVADs use speed modulation, which is not synchronized with the native left ventricle (LV) contractility. This study aims to investigate the effect of speed modulation on intraventricular flow patterns, and specifically, the impact of timing relative to pressure variations in the LV. Stereo-particle image velocimetry measurements were performed in a patient-derived LV implanted with an LVAD, for different timings of the speed modulation and speed. Speed modulation has a strong effect on instantaneous afterload and flowrate (-16% and +20%). The different timings of the speed modulation resulted in different flowrate waveforms, exhibiting different maxima (5.3-5.9 L/min, at constant average flowrate). Moreover, the timing of the speed modulation was found to strongly influence intraventricular flow patterns, specifically, stagnation areas within the LV. These experiments highlight, once more, the complex relationship between LVAD speed, hemodynamic resistance, and intraventricular pressure. Overall, this study demonstrates the importance of considering native LV contractility in future LVAD controls, to improve hemocompatibility and reduce the risk of thromboembolic complications.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Heart-Assist Devices/adverse effects , Hemodynamics , Heart Ventricles , Heart Failure/surgery , Heart Failure/etiology
4.
Cardiovasc Eng Technol ; 14(1): 115-128, 2023 02.
Article in English | MEDLINE | ID: mdl-35879587

ABSTRACT

PURPOSE: Computational fluid dynamics (CFD) has been used to evaluate the efficiency of endovascular treatment in coiled cerebral aneurysms. The explicit geometry of the coil mass cannot typically be incorporated into CFD simulations since the coil mass cannot be reconstructed from clinical images due to its small size and beam hardening artifacts. The existing methods use imprecise porous medium representations. We propose a new porous model taking into account the porosity heterogeneity of the coils deployed in the aneurysm. METHODS: The porosity heterogeneity of the coil mass deployed inside two patients' cerebral aneurysm phantoms is first quantified based on 3D X-ray synchrotron images. These images are also used to compute the permeability and the inertial factor arising in porous models. A new homogeneous porous model (porous crowns model), considering the coil's heterogeneity, is proposed to recreate the flow within the coiled aneurysm. Finally, the validity of the model is assessed through comparisons with coil-resolved simulations. RESULTS: The strong porosity gradient of the coil measured close to the aneurysmal wall is well captured by the porous crowns model. The permeability and the inertial factor values involved in this model are closed to the ideal homogeneous porous model leading to a mean velocity in the aneurysmal sac similar as in the coil-resolved model. CONCLUSION: The porous crowns model allows for an accurate description of the mean flow within the coiled cerebral aneurysm.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Porosity , Embolization, Therapeutic/adverse effects , Hydrodynamics
5.
J Biomech Eng ; 145(1)2023 01 01.
Article in English | MEDLINE | ID: mdl-35838329

ABSTRACT

Hemodynamic factors have long been associated with clinical outcomes in the treatment of cerebral aneurysms. Computational studies of cerebral aneurysm hemodynamics have provided valuable estimates of the mechanical environment experienced by the endothelium in both the parent vessel and aneurysmal dome walls and have correlated them with disease state. These computational-clinical studies have recently been correlated with the response of endothelial cells (EC) using either idealized or patient-specific models. Here, we present a robust workflow for generating anatomic-scale aneurysm models, establishing luminal cultures of ECs at physiological relevant flow profiles, and comparing EC responses to curvature mediated flow. We show that flow patterns induced by parent vessel curvature produce changes in wall shear stress (WSS) and wall shear stress gradients (WSSG) that are correlated with differences in cell morphology and cellular protein localization. Cells in higher WSS regions align better with the flow and display strong Notch1-extracellular domain (ECD) polarization, while, under low WSS, differences in WSSG due to curvature change were associated with less alignment and attenuation of Notch1-ECD polarization in ECs of the corresponding regions. These proof-of-concept results highlight the use of engineered cellularized aneurysm models for connecting computational fluid dynamics to the underlying endothelial biology that mediates disease.


Subject(s)
Intracranial Aneurysm , Endothelial Cells , Endothelium/metabolism , Hemodynamics/physiology , Humans , Hydrodynamics , Models, Cardiovascular , Stress, Mechanical
6.
J Biomech Eng ; 145(4)2023 04 01.
Article in English | MEDLINE | ID: mdl-36173034

ABSTRACT

The Circle of Willis (CoW) is a redundant network of blood vessels that perfuses the brain. The ringlike anatomy mitigates the negative effects of stroke by activating collateral pathways that help maintain physiological perfusion. Previous studies have investigated the activation of these pathways during embolic stroke and internal carotid artery occlusion. However, the role of collateral pathways during cerebral vasospasm-an involuntary constriction of blood vessels after subarachnoid hemorrhage-is not well-documented. This study presents a novel technique to create patient-specific computational fluid dynamics (CFD) simulations of the Circle of Willis before and during vasospasm. Computed tomographic angiography (CTA) scans are segmented to model the vasculature, and transcranial Doppler ultrasound (TCD) measurements of blood flow velocity are applied as boundary conditions. Bayesian analysis leverages information about the uncertainty in the measurements of vessel diameters and velocities to find an optimized parameter set that satisfies mass conservation and that is applied in the final simulation. With this optimized parameter set, the diameters, velocities, and flow rates fall within typical literature values. Virtual angiograms modeled using passive scalar transport agree closely with clinical angiography. A sensitivity analysis quantifies the changes in collateral flow rates with respect to changes in the inlet and outlet flow rates. This analysis can be applied in the future to a cohort of patients to investigate the relationship between the locations and severities of vasospasm, the patient-to-patient anatomical variability in the Circle of Willis, and the activation of collateral pathways.


Subject(s)
Circle of Willis , Hydrodynamics , Circle of Willis/diagnostic imaging , Bayes Theorem , Collateral Circulation/physiology , Cerebrovascular Circulation/physiology , Blood Flow Velocity/physiology
7.
J Fluid Mech ; 9152021 May 25.
Article in English | MEDLINE | ID: mdl-34658417

ABSTRACT

The flow in a spherical cavity on a curved round pipe is a canonical flow that describes well the flow inside a sidewall aneurysm on an intracranial artery. Intracranial aneurysms are often treated with a flow-diverting stent (FDS), a low-porosity metal mesh that covers the entrance to the cavity, to reduce blood flow into the aneurysm sac and exclude it from mechanical stresses imposed by the blood flow. Successful treatment is highly dependent on the degree of reduction of flow inside the cavity, and the resulting altered fluid mechanics inside the aneurysm following treatment. Using stereoscopic particle image velocimetry, we characterize the fluid mechanics in a canonical configuration representative of an intracranial aneurysm treated with a FDS: a spherical cavity on the side of a curved round pipe covered with a metal mesh formed by an actual medical FDS. This porous mesh coverage is the focus of Part 2 of the paper, characterizing the effects of parent vessel Re, De and pulsatility, Wo, on the fluid dynamics, compared with the canonical configuration with no impediments to flow into the cavity that is described in Part 1 (Chassagne et al., J. Fluid Mech., vol. 915, 2021, A123). Coverage with a FDS markedly reduces the flow Re in the aneurysmal cavity, creating a viscous-dominated flow environment despite the parent vessel Re > 100. Under steady flow conditions, the topology that forms inside the cavity is shown to be a function of the parent vessel De. At low values of De, flow enters the cavity at the leading edge and remains attached to the wall before exiting at the trailing edge, a novel behaviour that was not found under any conditions of the high-Re, unimpeded cavity flow described in Part 1. Under these conditions, flow in the cavity co-rotates with the direction of the free-stream flow, similar to Stokes flow in a cavity. As De increases, the flow along the leading edge begins to separate, and the recirculation zone grows with increasing De, until, above De ≈ 180, the flow inside the cavity is fully recirculating, counter-rotating with respect to the free-stream flow. Under pulsatile flow conditions, the vortex inside the cavity progresses through the same cycle - switching from attached and co-rotating with the free-stream flow at the beginning of the cycle (low velocity and positive acceleration) to separated and counter-rotating as De reaches a critical value. The location of separation within the harmonic cycle is shown to be a function of both De and Wo. The values of aneurysmal cavity Re based on both the average velocity and the circulation inside the cavity are shown to increase with increasing values of De, while Wo is shown to have little influence on the time-averaged metrics. As De increases, the strength of the secondary flow in the parent vessel grows, due to the inertial instability in the curved pipe, and the flow rate entering the cavity increases. Thus, the effectiveness of FDS treatment to exclude the aneurysmal cavity from the haemodynamic stresses is compromised for aneurysms located on high-curvature arteries, i.e. vessels with high De, and this can be a fluid mechanics criterion to guide treatment selection.

8.
J Fluid Mech ; 9152021 May 25.
Article in English | MEDLINE | ID: mdl-34024939

ABSTRACT

Flow in side-wall cerebral aneurysms can be ideally modelled as the combination of flow over a spherical cavity and flow in a curved circular pipe, two canonical flows. Flow in a curved pipe is known to depend on the Dean number De, combining the effects of Reynolds number, Re, and of the curvature along the pipe centreline, κ. Pulsatility in the flow introduces a dependency on the Womersley number Wo. Using stereo PIV measurements, this study investigated the effect of these three key non-dimensional parameters, by modifying pipe curvature (De), flow-rate (Re), and pulsatility frequency (Wo), on the flow patterns in a spherical cavity. A single counter-rotating vortex was observed in the cavity for all values of pipe curvature κ and Re, for both steady and pulsatile inflow conditions. Increasing the pipe curvature impacted both the flow patterns in the pipe and the cavity, by shifting the velocity profile towards the cavity opening and increasing the flow rate into the cavity. The circulation in the cavity was found to collapse well with only the Dean number, for both steady and pulsatile inflows. For pulsatile inflow, the counter-rotating vortex was unstable and the location of its centre over time was impacted by the curvature of the pipe, as well as the Re and the Wo in the freestream. The circulation in the cavity was higher for steady inflow than for the equivalent average Reynolds and Dean number pulsatile inflow, with very limited impact of the Womersley in the range studied.

9.
J Biomech Eng ; 143(7)2021 07 01.
Article in English | MEDLINE | ID: mdl-33665669

ABSTRACT

As frequency of endovascular treatments for intracranial aneurysms increases, there is a growing need to understand the mechanisms for coil embolization failure. Computational fluid dynamics (CFD) modeling often simplifies modeling the endovascular coils as a homogeneous porous medium (PM), and focuses on the vascular wall endothelium, not considering the biomechanical environment of platelets. These assumptions limit the accuracy of computations for treatment predictions. We present a rigorous analysis using X-ray microtomographic imaging of the coils and a combination of Lagrangian (platelet) and Eulerian (endothelium) metrics. Four patient-specific, anatomically accurate in vitro flow phantoms of aneurysms are treated with the same patient-specific endovascular coils. Synchrotron tomography scans of the coil mass morphology are obtained. Aneurysmal hemodynamics are computationally simulated before and after coiling, using patient-specific velocity/pressure measurements. For each patient, we analyze the trajectories of thousands of platelets during several cardiac cycles, and calculate residence times (RTs) and shear exposure, relevant to thrombus formation. We quantify the inconsistencies of the PM approach, comparing them with coil-resolved (CR) simulations, showing the under- or overestimation of key hemodynamic metrics used to predict treatment outcomes. We fully characterize aneurysmal hemodynamics with converged statistics of platelet RT and shear stress history (SH), to augment the traditional wall shear stress (WSS) on the vascular endothelium. Incorporating microtomographic scans of coil morphology into hemodynamic analysis of coiled intracranial aneurysms, and augmenting traditional analysis with Lagrangian platelet metrics improves CFD predictions, and raises the potential for understanding and clinical translation of computational hemodynamics for intracranial aneurysm treatment outcomes.


Subject(s)
Intracranial Aneurysm
10.
Article in English | MEDLINE | ID: mdl-33747785

ABSTRACT

Parkes Weber syndrome is a fast-flow and slow-flow vascular anomaly with limb overgrowth that can lead to congestive heart failure and limb ischemia. Current management strategies have focused on symptom management with focal embolization. A pediatric case with early onset heart failure is reported. We discuss the use of computational fluid dynamics (CFD) modeling to guide a surgical management strategy in a toddler with an MAP2K1 mutation.

11.
Ann Biomed Eng ; 49(5): 1318-1332, 2021 May.
Article in English | MEDLINE | ID: mdl-33128182

ABSTRACT

Stroke has become the main cause of mortality and morbidity in patients treated with Left Ventricular Assist Devices (LVADs). The hemodynamics of the left ventricle are altered by the implantation of an LVAD, with the increase of thrombogenic flow patterns, such as stagnation regions. Time-resolved stereo particle image velocimetry (Stereo-PIV) measurements of the flow inside a patient-specific model of the left ventricle (LV) implanted with an LVAD were performed. The effects of LVAD speed, peripheral resistance and afterload were investigated. The impact of activating the LVAD pulsatility mode (periodic speed modulation) was also evaluated. Analysis of the velocity measurements in two orthogonal planes revealed stagnation zones which may be favorable to thrombus formation. Increasing LVAD speed, despite increasing the flow rate through the inflow cannula, does not automatically result in smaller stagnation regions. These results demonstrated the strong interdependence of peripheral resistance, afterload and flow through the LVAD. As a consequence, the pulsatility mode showed very limited effect on overall flow rate. However, it did reduce the size of high stagnation areas. This study showed how LVAD speed, peripheral resistance and afterload impact the complex intraventricular flow patterns in a ventricle implanted with an LVAD and quantify their thrombogenic risk.


Subject(s)
Heart Ventricles , Heart-Assist Devices , Ventricular Function, Left , Hemodynamics , Humans , Patient-Specific Modeling , Rheology
12.
ESC Heart Fail ; 7(6): 4241-4246, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33001579

ABSTRACT

AIMS: Optimal blood pressure (BP) control is imperative to reduce complications, especially strokes, in continuous flow ventricular assist device (VAD) patients. Doppler BP has been shown to be an accurate and reliable non-invasive BP measurement method in HeartMate II and HVAD patients. We examined whether Doppler BP is also accurate in patients with the HeartMate 3 VAD. METHODS AND RESULTS: In a prospective, longitudinal cohort of HeartMate 3 patients, arterial line BP and simultaneously measured Doppler opening pressure were obtained. Correlation and agreement between Doppler opening pressure and arterial line mean arterial pressure (MAP) versus systolic blood pressure (SBP) were analysed, as well as the effect of pulse pressure on the accuracy of Doppler opening pressure. A total of 589 pairs of simultaneous Doppler opening pressure and arterial line pressure readings were obtained in 43 patients. Doppler opening pressure had good correlation with intra-arterial MAP (r = 0.754) and more closely approximated MAP than SBP (mean error 2.0 vs. -8.6 mmHg). Pulse pressure did not have a clinically significant impact on the accuracy of the Doppler BP method. These results in HeartMate 3 patients are very similar to previous results in HeartMate II and HVAD patients. CONCLUSIONS: Doppler BP method should be the default non-invasive BP measurement method in continuous flow VAD patients including patients implanted with the HeartMate 3.

13.
Ann Biomed Eng ; 48(1): 490-501, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31549329

ABSTRACT

Flow-diverting stents (FDS) are used to treat cerebral aneurysms. They promote the formation of a stable thrombus within the aneurysmal sac and, if successful, isolate the aneurysmal dome from mechanical stresses to prevent rupture. Platelet activation, a mechanism necessary for thrombus formation, is known to respond to biomechanical stimuli, particularly to the platelets' residence time and shear stress exposure. Currently, there is no reliable method for predicting FDS treatment outcomes, either a priori or after the procedure. Eulerian computational fluid dynamic (CFD) studies of aneurysmal flow have searched for predictors of endovascular treatment outcome; however, the hemodynamics of thrombus formation cannot be fully understood without considering the platelets' trajectories and their mechanics-triggered activation. Lagrangian analysis of the fluid mechanics in the aneurysmal vasculature provides novel metrics by tracking the platelets' residence time (RT) and shear history (SH). Eulerian and Lagrangian parameters are compared for 19 patient-specific cases, both pre- and post-treatment, to assess the degree of change caused by the FDS and subsequent treatment efficacy.


Subject(s)
Blood Platelets/physiology , Intracranial Aneurysm/therapy , Stents , Computer Simulation , Hemodynamics , Humans , Models, Biological
14.
Neuromodulation ; 23(3): 373-379, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31124218

ABSTRACT

OBJECTIVE: To evaluate the effect of a single session of tDCS over the primary motor cortex of the lower limb (M1-LL) vs. placebo on the walking performance in chronic hemiplegic patients. PATIENTS AND METHODS: Randomized, cross-over, double-blinded study. Eighteen patients with initially complete hemiplegia and poststroke delay >6 months were included. Each patient received a single session of anodal stimulation (2 mA, 20 min) over M1-LL (a-tDCS condition) and a pseudostimulation session (SHAM condition). The order of the two sessions was randomly assigned, with an 11-day interval between the two sessions. The anodal electrode was centered on the hotspot identified with Transcranial magnetic stimulation. The cathode was placed above the contralesional orbitofrontal cortex. Walking performance was evaluated with the Wade test and the 6-minute walk test (6MWT), gait parameters with GAITRite, and balance with posturography. These tests were performed during and 1 hour after the stimulation. Baseline assessments were performed the day before and 10 days after each session. RESULTS: The comparison between the 6MWT under a-tDCS vs. SHAM conditions demonstrated a nonsignificant positive effect of the stimulation by 15% during stimulation (p = 0.360) and a significant positive effect of 25% 1 hour after stimulation (p = 0.038). No significant differences were observed for the other evaluations. DISCUSSION: These results showed a significant positive effect of a single session of anodal tDCS of the M1-LL in chronic hemiplegic patients. This proof-of-concept study supports the conduct of clinical studies evaluating the effectiveness of a walking training program associated with iterative tDCS stimulation. CONFLICT OF INTEREST: The authors reported no conflict of interest.


Subject(s)
Hemiplegia/therapy , Stroke Rehabilitation/methods , Transcranial Direct Current Stimulation/methods , Walking , Double-Blind Method , Electrodes , Female , Hemiplegia/etiology , Humans , Male , Middle Aged , Motor Cortex/physiology , Treatment Outcome
15.
ASAIO J ; 66(7): 766-773, 2020 07.
Article in English | MEDLINE | ID: mdl-31453832

ABSTRACT

Left ventricular assist device (LVAD) use has continued to grow. Despite recent advances in technology, LVAD patients continue to suffer from devastating complications, including stroke and device thrombosis. Among several variables affecting thrombogenicity, we hypothesize that insertion depth of the inflow cannula into the left ventricle (LV) influences hemodynamics and thrombosis risk. Blood flow patterns were studied in a patient-derived computational model of the LV, mitral valve (MV), and LVAD inflow cannula using unsteady computational fluid dynamics (CFD). Hundreds of thousands of platelets were tracked individually, for two inflow cannula insertion depth configurations (12 mm-reduced and 27 mm-conventional) using platelet-level (Lagrangian) metrics to quantify thrombogenicity. Particularly in patients with small LV dimensions, the deeper inflow cannula insertion resulted in much higher platelet shear stress histories (SH), consistent with markedly abnormal intraventricular hemodynamics. A larger proportion of platelets in this deeper insertion configuration was found to linger in the domain for long residence times (RT) and also accumulated much higher SH. The reduced inflow depth configuration promoted LV washout and reduced platelet SH. The increase of both SH and RT in the LV demonstrates the impact of inflow cannula depth on platelet activation and increased stroke risk in these patients. Inflow cannula depth of insertion should be considered as an opportunity to optimize surgical planning of LVAD therapy.


Subject(s)
Cannula/adverse effects , Catheterization/methods , Heart-Assist Devices/adverse effects , Models, Cardiovascular , Thrombosis/etiology , Cardiovascular Surgical Procedures/adverse effects , Cardiovascular Surgical Procedures/methods , Catheterization/adverse effects , Heart Ventricles/physiopathology , Hemodynamics/physiology , Humans , Hydrodynamics , Stress, Mechanical
16.
ESC Heart Fail ; 6(4): 793-798, 2019 08.
Article in English | MEDLINE | ID: mdl-31099483

ABSTRACT

AIMS: Accurate blood pressure (BP) measurement in continuous-flow ventricular assist device (CF-VAD) patients is imperative to reduce stroke risk. This study assesses the accuracy of the Doppler opening pressure method compared with the gold standard arterial line method in CF-VAD patients. METHODS AND RESULTS: In a longitudinal cohort of HeartMate II and HVAD patients, arterial line BP and simultaneously measured Doppler opening pressure were obtained. Overall correlation, agreement between Doppler opening pressure and arterial line mean vs. systolic pressure, and the effect of arterial pulsatility on the accuracy of Doppler opening pressure were analysed. A total of 1933 pairs of Doppler opening pressure and arterial line pressure readings within 1 min of each other were identified in 154 patients (20% women, mean age 55 ± 15, 50% HeartMate II and 50% HVAD). Doppler opening pressure had good correlation with invasive mean arterial pressure (r = 0.742, P < 0.0001) and more closely approximated mean than systolic BP (mean error 2.4 vs. -8.4 mmHg). Arterial pulsatility did not have a clinically significant effect on the accuracy of the Doppler opening pressure method. CONCLUSIONS: Doppler opening pressure should be the standard non-invasive method of BP measurement in CF-VAD patients.


Subject(s)
Blood Pressure Determination/methods , Heart Failure/physiopathology , Heart Failure/therapy , Heart-Assist Devices , Ultrasonography, Doppler , Adult , Aged , Cohort Studies , Female , Humans , Longitudinal Studies , Male , Middle Aged
17.
IEEE Trans Biomed Eng ; 65(2): 449-457, 2018 02.
Article in English | MEDLINE | ID: mdl-29346112

ABSTRACT

OBJECTIVE: To develop a new method for the prediction of interface pressure applied by medical compression bandages. METHODS: A finite element simulation of bandage application was designed, based on patient-specific leg geometries. For personalized interface pressure prediction, a model reduction approach was proposed, which included the parametrization of the leg geometry. Pressure values computed with this reduced model were then confronted to experimental pressure values. RESULTS: The most influencing parameters were found to be the bandage tension, the skin-to-bandage friction coefficient and the leg morphology. Thanks to the model reduction approach, it was possible to compute interface pressure as a linear combination of these parameters. The pressures computed with this reduced model were in agreement with experimental pressure values measured on 66 patients' legs. CONCLUSION: This methodology helps to predict patient-specific interface pressure applied by compression bandages within a few minutes whereas it would take a few days for the numerical simulation. The results of this method show less bias than Laplace's Law, which is for now the only other method for interface pressure computation.


Subject(s)
Compression Bandages , Leg/physiopathology , Patient-Specific Modeling , Adult , Female , Finite Element Analysis , Friction/physiology , Humans , Lymphatic Diseases/therapy , Male , Middle Aged , Pressure , Vascular Diseases/therapy
18.
J Vasc Surg Venous Lymphat Disord ; 5(6): 851-858, 2017 11.
Article in English | MEDLINE | ID: mdl-29037358

ABSTRACT

OBJECTIVE: The objective of this study was to investigate the pressure applied by superimposed bandages and to compare it with the pressure applied by single-component bandages. METHODS: Six different bandages, composed of one elastic bandage, one nonelastic bandage, or both, were applied in a spiral pattern on both legs of 25 patients at risk of venous thrombosis as a consequence of central or peripheral motor deficiency. Pressure was measured at four measurement points on the leg (B1 and C on the medial and lateral sides of the leg) and in three positions: supine, sitting, and standing. RESULTS: The two single bandages applied similar pressure in the supine position. Their superimposition showed different pressure levels (P < .05) but similar static stiffness index, depending on the order in which the bandage components were applied on the leg. The highest interface pressure was measured at point B1 on the medial side of the leg. This point also showed the highest pressure increase from supine to standing position. The pressure applied by the superimposition of two bandages was computed as a linear combination of the pressure applied by each single component (with a constant term set to 0). However, this linear combination did not properly fit the experimental pressure measurements. CONCLUSIONS: The order of bandage application showed a significant impact on interface pressure. However, the poor correlation between the pressure applied by each bandage component and the pressure resulting from their superimposition underlined the poor understanding of interface pressure generated by the superimposition of compression bandages and should lead to further investigations.


Subject(s)
Compression Bandages , Venous Thrombosis/prevention & control , Adult , Aged , Female , Humans , Male , Middle Aged , Posture , Pressure , Young Adult
19.
Ann Biomed Eng ; 44(10): 3096-3108, 2016 10.
Article in English | MEDLINE | ID: mdl-27026575

ABSTRACT

Compression of the lower leg by bandages is a common treatment for the advanced stages of some venous or lymphatic pathologies. The outcomes of this treatment directly result from the pressure generated onto the limb. Various bandage configurations are proposed by manufacturers: the study of these configurations requires the development of reliable methods to predict pressure distribution applied by compression bandages. Currently, clinicians and manufacturers have no dedicated tools to predict bandage pressure generation. A numerical simulation approach is presented in this work, which includes patient-specific leg geometry and bandage. This model provides the complete pressure distribution over the leg. The results were compared to experimental pressure measurements and pressure values computed with Laplace's law. Using an appropriate surrogate model, this study demonstrated that such simulation is appropriate to account for phenomena which are neglected in Laplace's law, like geometry changes due to bandage application.


Subject(s)
Compression Bandages , Leg , Models, Biological , Pressure , Adult , Female , Humans , Middle Aged
20.
Ann Biomed Eng ; 43(12): 2967-77, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26063162

ABSTRACT

Compression therapy with stockings or bandages is the most common treatment for venous or lymphatic disorders. The objective of this study was to investigate the influence of bandage mechanical properties, application technique and subject morphology on the interface pressure, which is the key of this treatment. Bandage stretch and interface pressure measurements (between the bandage and the leg) were performed on 30 healthy subjects (15 men and 15 women) at two different heights on the lower leg and in two positions (supine and standing). Two bandages were applied with two application techniques by a single operator. The statistical analysis of the results revealed: no significant difference in pressure between men and women, except for the pressure variation between supine and standing positions; a very strong correlation between pressure and bandage mechanical properties (p < 0.00001) and between pressure and bandage overlapping (p < 0.00001); a significant pressure increase from supine to standing positions (p < 0.0001). Also, it showed that pressure tended to decrease when leg circumference increased. Overall, pressure applied by elastic compression bandages varies with subject morphology, bandage mechanical properties and application technique. A better knowledge of the impact of these parameters on the applied pressure may lead to a more effective treatment.


Subject(s)
Compression Bandages , Leg/physiology , Pressure , Adult , Female , Humans , Male , Posture
SELECTION OF CITATIONS
SEARCH DETAIL
...