Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 71
Filter
1.
Opt Lett ; 48(17): 4645-4648, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37656576

ABSTRACT

Two compact laser sources at 707 and 714 nm are realized efficiently by using a diode-pumped a-cut Nd:YVO4 laser with intracavity stimulated Raman scattering and sum-frequency generation (SFG). The fundamental wave at 1342 nm is generated by the 4F3/2 → 4I13/2 transition in Nd:YVO4 crystal. The Raman Stokes waves at 1496 and 1526 nm were obtained by placing the c-axis of the Nd:YVO4 crystal along the Ng and Nm axes of an Np-cut KGW crystal, respectively. LBO crystals with critical phase matching are used to perform the intracavity SFG of fundamental and Stokes waves. At a pump power of 36 W, the maximum output powers at 707 and 714 nm can reach 2.72 and 3.14 W, corresponding to light-to-light conversion efficiencies of 7.5% and 8.7%, respectively. The developed 707 and 714 nm laser sources are practically useful in laser trapping and cooling related to atomic strontium and radium.

2.
Opt Express ; 31(5): 8696-8703, 2023 Feb 27.
Article in English | MEDLINE | ID: mdl-36859979

ABSTRACT

Efficient diode-pumped passively Q-switched Nd:YVO4 yellow and orange lasers are developed with the pulse pumping scheme and the intracavity stimulated Raman scattering (SRS) and second harmonic generation (SHG). A Np-cut KGW is exploited in the SRS process to generate the yellow 579 nm laser or the orange 589 nm laser in a selectable way. The high efficiency is achieved by designing a compact resonator to include a coupled cavity for intracavity SRS and SHG and to provide a focused beam waist on the saturable absorber for reaching an excellent passive Q-switching. The output pulse energy and peak power can reach 0.08 mJ and 50 kW for the orange laser at 589 nm. On the other hand, the output pulse energy and peak power can be up to 0.10 mJ and 80 kW for the yellow laser at 579 nm.

3.
Opt Lett ; 48(6): 1510-1513, 2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36946965

ABSTRACT

A compact efficient continuous wave (CW) laser with selectable two wavelengths at 671 and 714 nm is developed. The laser cavity comprises an Nd-doped and an undoped YVO4 crystal to generate the fundamental wave at 1342 nm and the first-Stokes Raman wave at 1525 nm, respectively. A single LBO crystal with the cut angle in the XZ plane is designed to achieve the selectable phase-matching via the thermal tuning for the second harmonic generation (SHG) of 1342 nm and the sum frequency generation (SFG) of 1342 and 1525 nm. At a pump power of 40 W, the optimal output powers at 671 and 714 nm can reach 4.5 and 1.8 W, respectively. The present compact CW laser source at 671 and 714 nm has practical usefulness for laser spectroscopy and numerous applications.

4.
Sci Rep ; 13(1): 2556, 2023 02 13.
Article in English | MEDLINE | ID: mdl-36781924

ABSTRACT

Left ventricular hypertrophy (LVH) indicates subclinical organ damage, associating with the incidence of cardiovascular diseases. From the medical perspective, electrocardiogram (ECG) is a low-cost, non-invasive, and easily reproducible tool that is often used as a preliminary diagnosis for the detection of heart disease. Nowadays, there are many criteria for assessing LVH by ECG. These criteria usually include that voltage combination of RS peaks in multi-lead ECG must be greater than one or more thresholds for diagnosis. We developed a system for detecting LVH using ECG signals by two steps: firstly, the R-peak and S-valley amplitudes of the 12-lead ECG were extracted to automatically obtain a total of 24 features and ECG beats of each case (LVH or non-LVH) were segmented; secondly, a back propagation neural network (BPN) was trained using a dataset with these features. Echocardiography (ECHO) was used as the gold standard for diagnosing LVH. The number of LVH cases (of a Taiwanese population) identified was 173. As each ECG sequence generally included 8 to 13 cycles (heartbeats) due to differences in heart rate, etc., we identified 1466 ECG cycles of LVH patients after beat segmentation. Results showed that our BPN model for detecting LVH reached the testing accuracy, precision, sensitivity, and specificity of 0.961, 0.958, 0.966 and 0.956, respectively. Detection performances of our BPN model, on the whole, outperform 7 methods using ECG criteria and many ECG-based artificial intelligence (AI) models reported previously for detecting LVH.


Subject(s)
Cardiovascular Diseases , Hypertrophy, Left Ventricular , Humans , Artificial Intelligence , Electrocardiography/methods , Echocardiography/adverse effects , Cardiovascular Diseases/complications
5.
ACS Appl Mater Interfaces ; 15(8): 10812-10819, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36802479

ABSTRACT

Heterogeneous integration of monolayers is an emergent route of spatially combining materials with available platforms for unprecedented properties. A long-standing challenge along this route is to manipulate interfacial configurations of each unit in stacking architecture. A monolayer of transition metal dichalcogenides (TMDs) offers an embodiment of studying interface engineering of integrated systems because optoelectronic performances generally trade off with each other due to interfacial trap states. While ultrahigh photoresponsivity of TMDs phototransistors has been realized, a long response time commonly appears and hinders applications. Here, fundamental processes in excitation and relaxation of the photoresponse are studied and correlated with interfacial traps of the monolayer MoS2. A mechanism for the onset of saturation photocurrent and the reset behavior in the monolayer photodetector is illustrated based on device performances. Electrostatic passivation of interfacial traps is achieved with the bipolar gate pulse and significantly reduces the response time for photocurrent to reach saturated states. This work paves the way toward fast-speed and ultrahigh-gain devices of stacked two-dimensional monolayers.

6.
Rev Sci Instrum ; 93(8): 084501, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-36050105

ABSTRACT

We report on a holoscope axion search experiment near 19.6 µeV from the Taiwan Axion Search Experiment with Haloscope collaboration. This experiment is carried out via a frequency-tunable cavity detector with a volume V = 0.234 liter in a magnetic field B0 = 8 T. With a signal receiver that has a system noise temperature Tsys ≅ 2.2 K and an experiment time of about one month, the search excludes values of the axion-photon coupling constant gaγγ ≳ 8.1 × 10-14 GeV-1, a factor of 11 above the Kim-Shifman-Vainshtein-Zakharov benchmark model, at the 95% confidence level in the mass range of 19.4687-19.8436 µeV. We present the experimental setup and procedures to accomplish this search.

7.
Phys Rev Lett ; 129(11): 111802, 2022 Sep 09.
Article in English | MEDLINE | ID: mdl-36154404

ABSTRACT

This Letter reports on the first results from the Taiwan Axion Search Experiment with a Haloscope, a search for axions using a microwave cavity at frequencies between 4.707 50 and 4.798 15 GHz. Apart from the nonaxion signals, no candidates with a significance of more than 3.355 were found. The experiment excludes models with the axion-two-photon coupling |g_{aγγ}|≳8.1×10^{-14} GeV^{-1}, a factor of eleven above the benchmark Kim-Shifman-Vainshtein-Zakharov model, in the mass range 19.4687

8.
Entropy (Basel) ; 24(2)2022 Jan 29.
Article in English | MEDLINE | ID: mdl-35205510

ABSTRACT

The resonant modes generated from the modern Chladni experiment are systematically confirmed to intimately correspond to the maximum entropy states obtained from the inhomogeneous Helmholtz equation for the square and equilateral triangle plates. To investigate the origin of maximum entropy states, the inhomogeneous Helmholtz equation is modified to consider the point interaction coming from the driving oscillator. The coupling strength associated with the point interaction is characterized by a dimensionless factor α. The δ potential of the point interaction is numerically modelled by a truncated basis with an upper index N. The asymptotic behavior for the upper index N is thoroughly explored to verify that the coupling strength of α = 1.0 can make the theoretical resonant modes agree excellently with the maximum entropy states as N→∞. It is further authenticated that nearly the same resonant modes can be obtained by using a larger coupling strength α when a smaller upper index N is exploited in the calculation.

9.
Phys Rev E ; 103(4-1): 042138, 2021 Apr.
Article in English | MEDLINE | ID: mdl-34005981

ABSTRACT

Electric circuits influenced by thermal noise are analogous to confined Brownian particles and can be an alternative and convenient scheme for studying stochastic thermodynamics. Here we experimentally demonstrate an effective technique of generating tunable potentials for Brownian dynamics in an electric circuit, realized by external controlled feedback. We present two illustrative examples of one-dimensional virtual potentials: static harmonic potential and time-varying double-well potential. The thermal noises of both cases undergo equivalent Brownian dynamics as if they were in the authentic potentials as long as the feedback is fast enough to respond to the designed potentials. The results show that the electric circuit provides a simple, effective, and programmable scheme to study the feedback-controlled virtual potential.

10.
Phys Rev E ; 103(2-1): 022128, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33735993

ABSTRACT

We study the nonequilibrium steady-state (NESS) dynamics of two-dimensional Brownian gyrators under harmonic and nonharmonic potentials via computer simulations and analyses based on the Fokker-Planck equation, while our nonharmonic cases feature a double-well potential and an isotropic quartic potential. In particular, we report two simple methods that can help understand gyrating patterns. For harmonic potentials, we use the Fokker-Planck equation to survey the NESS dynamical characteristics; i.e., the NESS currents gyrate along the equiprobability contours and the stationary point of flow coincides with the potential minimum. As a contrast, the NESS results in our nonharmonic potentials show that these properties are largely absent, as the gyrating patterns are very distinct from those of corresponding probability distributions. Furthermore, we observe a critical case of the double-well potential, where the harmonic contribution to the gyrating pattern becomes absent, and the NESS currents do not circulate about the equiprobability contours near the potential minima even at low temperatures.

11.
Nanoscale Res Lett ; 15(1): 61, 2020 Mar 12.
Article in English | MEDLINE | ID: mdl-32166402

ABSTRACT

Nanoelectronics of two-dimensional (2D) materials and related applications are hindered with critical contact issues with the semiconducting monolayers. To solve these issues, a fundamental challenge is selective and controllable fabrication of p-type or ambipolar transistors with a low Schottky barrier. Most p-type transistors are demonstrated with tungsten selenides (WSe2) but a high growth temperature is required. Here, we utilize seeding promoter and low pressure CVD process to enhance sequential WSe2 growth with a reduced growth temperature of 800 °C for reduced compositional fluctuations and high hetero-interface quality. Growth behavior of the sequential WSe2 growth at the edge of patterned graphene is discussed. With optimized growth conditions, high-quality interface of the laterally stitched WSe2-graphene is achieved and characterized with transmission electron microscopy (TEM). Device fabrication and electronic performances of the laterally stitched WSe2-graphene are presented.

12.
Opt Lett ; 44(13): 3202-3205, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31259921

ABSTRACT

An efficient LED pumping module is explored for the demonstration of energy scaling of passively Q-switched output to millijoule high-pulse-energy level. For the free-running operation at fundamental wavelength, the highest optical conversion efficiency of 23.7% is reached. By using a Cr4+:YAG crystal as the saturable absorber, the passively Q-switched output energy is up to 14.5 mJ in a compact setup. The laser resonator is further optimized to shorten the output pulse width and to obtain better mode quality. The pulse width of the Q-switched emission is as short as 25 ns, and the peak power is up to 0.7 MW. With such a highly efficient configuration, the extracavity second-harmonic generation at 532 nm can be achieved with 4.5 mJ pulse energy.

13.
Opt Express ; 27(13): 18190-18200, 2019 Jun 24.
Article in English | MEDLINE | ID: mdl-31252766

ABSTRACT

We demonstrate the direct generation of visible vortex beams at 640 nm and 607 nm by employing an off-axis pumping scheme in a diode end-pumped Pr3+:YLF laser. A detailed numerical analysis, based on the coherent superposition of Hermite-Gaussian modes with different amplitudes and phases, is perfectly consistent with the experimentally observed lasing modes. The maximum vortex output powers have been measured to be 808 mW and 211 mW at a pump power of 3.16 W, for the wavelengths of 640 nm and 607 nm, respectively. We also demonstrate the handedness control of the generated vortex beam. Such a visible vortex laser can potentially be applied in super-resolution fluorescent microscopes and micro-fabrication research.

14.
Sci Rep ; 9(1): 8235, 2019 Jun 03.
Article in English | MEDLINE | ID: mdl-31160646

ABSTRACT

We implement a logic switch by using a graphene acoustoelectric transducer at room temperature. We operate two pairs of inter-digital transducers (IDTs) to launch surface acoustic waves (SAWs) on a LiNbO3 substrate and utilize graphene as a channel material to sustain acoustoelectric current Iae induced by SAWs. By cooperatively tuning the input power on the IDTs, we can manipulate the propagation direction of Iae such that the measured Iae can be deliberately controlled to be positive, negative, or even zero. We define the zero-crossing Iae as [Formula: see text], and then demonstrate that Iae can be switched with a ratio [Formula: see text] at a rate up to few tens kHz. Our device with an accessible operation scheme provides a means to convert incoming acoustic waves modulated by digitized data sequence onto electric signals with frequency band suitable for digital audio modulation. Consequently, it could potentially open a route for developing graphene-based logic devices in large-scale integration electronics.

15.
Opt Lett ; 44(2): 327-330, 2019 Jan 15.
Article in English | MEDLINE | ID: mdl-30644892

ABSTRACT

The design criterion of thermal conductivity for the GaAs/AlAs distributed Bragg reflector (DBR) superlattice structure was thoroughly investigated to precisely analyze the thermal behaviors of the optically pumped vertically external cavity surface-emitting laser (VECSEL). A finite element model with detailed configuration of a VECSEL gain chip was constructed to fulfill the analysis. A 1060 nm VECSEL with different pump conditions was further demonstrated to verify the finite element analysis. At the VECSEL thermal rollover point, the analysis results show that the model with the superlattice property predicts more precise temperature values than that using a bulk composite property. It reveals that the accurate determination of the thermal conductivity of the DBR superlattice is significantly important for the VECSEL thermal analysis.

16.
IEEE J Biomed Health Inform ; 23(5): 2127-2137, 2019 09.
Article in English | MEDLINE | ID: mdl-30369456

ABSTRACT

Erectile dysfunction (ED) affects millions of men worldwide. Men with ED generally complain failure to attain or maintain an adequate erection during sexual activity. The prevalence of ED is strongly correlated with age, affecting about 40% of men at age 40 and nearly 70% at age 70. A variety of chronic diseases, including diabetes, ischemic heart disease, congestive heart failure, hypertension, depression, chronic renal failure, obstructive sleep apnea, prostate disease, gout, and sleep disorder, were reported to be associated with ED. In this study, data retrieved from a subset of the National Health Insurance Research Database of Taiwan were used for designing the clinical decision support system (CDSS) for predicting ED incidences in men. The positive cases were male patients aged 20-65 who were diagnosed with ED between January 2000 and December 2010 confirmed by at least three outpatient visits or at least one inpatient visit, while the negative cases were randomly selected from the database without a history of ED and were frequency (1:1), age, and index year matched with the ED patients. Data of a total of 2832 ED patients and 2832 non-ED patients, each consisting of 41 features including index age, 10 comorbidities, and 30 other comorbidity-related variables, were retrieved for designing the predictive models. Integrated genetic algorithm and support vector machine was adopted to design the CDSSs with two experiments of independent training and testing (ITT) conducted to verify their effectiveness. In the 1st ITT experiment, data extracted from January 2000 till December 2005 (61.51%, 1742 positive cases and 1742 negative cases) were used for training and validating and the data retrieved from January 2006 till December 2010 were used for testing (38.49%), whereas in the 2nd ITT experiment, data in the training set (77.78%) were extracted from January 2000 till Deceber 2007 and those in the testing set (22.22%) were retrieved afterward. Tenfold cross validation and three different objective functions were adopted for obtaining the optimal models with best predictive performance in the training phase. The testing results show that the CDSSs achieved a predictive performance with accuracy, sensitivity, specificity, g-mean, and area under ROC curve of 74.72%-76.65%, 72.33%-83.76%, 69.54%-77.10%, 0.7468-0.7632, and 0.766-0.817, respectively. In conclusion, the CDSSs designed based on cost-sensitive objective functions as well as salient comorbidity-related features achieve satisfactory predictive performance for predicting ED incidences.


Subject(s)
Decision Support Systems, Clinical , Erectile Dysfunction/diagnosis , Adult , Aged , Algorithms , Databases, Factual , Humans , Male , Middle Aged , Support Vector Machine , Young Adult
17.
Opt Lett ; 43(23): 5753-5756, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-30499985

ABSTRACT

A novel scheme to realize a mode-locked laser with a narrow spectral linewidth is demonstrated by exploiting a reflected Fabry-Perot (FP) cavity to introduce an intense FP effect. Stable continuous-wave mode-locked operation is achieved with the repetition rate of 48 MHz and the maximum average output power of 2.6 W under an incident pump power of 11.9 W. The mode-locked pulse width is systematically investigated by varying the optical thickness of the reflected FP cavity. The pulse duration is experimentally found to be in a range of 0.8 to 2.6 ns. The experimental results reveal that the reflected FP cavity is the key factor leading to the pulse generation in the nanosecond regime. This Letter is believed to provide a promising method for generating optical pulses with narrow spectral linewidths.

19.
Urology ; 119: 62-69, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29894774

ABSTRACT

OBJECTIVE: To assess effectiveness of the video-based m-health system providing videos dictated by physicians for health education and symptom self-management for patients with Interstitial cystitis/bladder pain syndrome (IC/BPS). METHODS: An m-health system was designed to provide videos for weekly health education and symptom flare self-management. O'Leary-Sant index and visual analogue scale as well as SF-36 health survey were administrated to evaluate the disease severity and quality of life (QoL), respectively. A total of 60 IC/BPS patients were recruited and randomly assigned to either control group (30 patients) or study group (30 patients) in sequence depending on their orders to visit our urological clinic. Patients in both control and study groups received regular treatments, while those in the study group received additional video-based intervention. Statistical analyses were conducted to compare the outcomes between baseline and postintervention for both groups. The outcomes of video-based intervention were also compared with the text-based intervention conducted in our previous study. RESULTS: After video-based intervention, patients in the study group exhibited significant effect manifested in all disease severity and QoL assessments except the pain visual analogue scale, while no significance was found in the control group. Moreover, the study group exhibited more significant net improvements than the control group in 7 SF-36 constructs, except the mental health. The limitations include short intervention duration (8 weeks) and different study periods between text-based and video-based interventions. CONCLUSION: Video-based intervention is effective in improving the QoL of IC/BPS patients and outperforms the text-based intervention even in a short period of intervention.


Subject(s)
Cystitis, Interstitial/therapy , Health Education , Self Care , Symptom Flare Up , Telemedicine , Adult , Female , Humans , Middle Aged , Video Recording
20.
J Healthc Eng ; 2018: 9621640, 2018.
Article in English | MEDLINE | ID: mdl-29765586

ABSTRACT

More than 1 billion people suffer from chronic respiratory diseases worldwide, accounting for more than 4 million deaths annually. Inhaled corticosteroid is a popular medication for treating chronic respiratory diseases. Its side effects include decreased bone mineral density and osteoporosis. The aims of this study are to investigate the association of inhaled corticosteroids and fracture and to design a clinical support system for fracture prediction. The data of patients aged 20 years and older, who had visited healthcare centers and been prescribed with inhaled corticosteroids within 2002-2010, were retrieved from the National Health Insurance Research Database (NHIRD). After excluding patients diagnosed with hip fracture or vertebrate fractures before using inhaled corticosteroid, a total of 11645 patients receiving inhaled corticosteroid therapy were included for this study. Among them, 1134 (9.7%) were diagnosed with hip fracture or vertebrate fracture. The statistical results showed that demographic information, chronic respiratory diseases and comorbidities, and corticosteroid-related variables (cumulative dose, mean exposed daily dose, follow-up duration, and exposed duration) were significantly different between fracture and nonfracture patients. The clinical decision support systems (CDSSs) were designed with integrated genetic algorithm (GA) and support vector machine (SVM) by training and validating the models with balanced training sets obtained by random and cluster-based undersampling methods and testing with the imbalanced NHIRD dataset. Two different objective functions were adopted for obtaining optimal models with best predictive performance. The predictive performance of the CDSSs exhibits a sensitivity of 69.84-77.00% and an AUC of 0.7495-0.7590. It was concluded that long-term use of inhaled corticosteroids may induce osteoporosis and exhibit higher incidence of hip or vertebrate fractures. The accumulated dose of ICS and OCS therapies should be continuously monitored, especially for patients with older age and women after menopause, to prevent from exceeding the maximum dosage.


Subject(s)
Adrenal Cortex Hormones/adverse effects , Decision Support Systems, Clinical , Hip Fractures/diagnosis , Respiration Disorders/drug therapy , Spinal Fractures/diagnosis , Administration, Inhalation , Adrenal Cortex Hormones/administration & dosage , Adult , Aged , Algorithms , Area Under Curve , Bone Density/drug effects , Comorbidity , Databases, Factual , Female , Hip Fractures/complications , Humans , Insurance, Health/statistics & numerical data , Male , Middle Aged , Osteoporosis/chemically induced , Prevalence , Prospective Studies , Respiration Disorders/complications , Software , Spinal Fractures/complications , Support Vector Machine , Taiwan/epidemiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...