1.
Med Phys ; 46(7): 3245-3253, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31081542

ABSTRACT

PURPOSE: To study the accuracy with which proton stopping power ratio (SPR) can be determined with dual-energy computed tomography (DECT) for small structures and bone-tissue-air interfaces like those found in the head or in the neck. METHODS: Hollow cylindrical polylactic acid (PLA) plugs (3 cm diameter, 5 cm height) were 3D printed containing either one or three septa with thicknesses tsepta  = 0.8, 1.6, 3.2, and 6.4 mm running along the length of the plug. The cylinders were inserted individually into a tissue-equivalent head phantom (16 cm diameter, 5 cm height). First, DECT scans were obtained using a Siemens SOMATOM Definition Edge CT scanner. Effective atomic number (Zeff ) and electron density (ρe ) images were reconstructed from the DECT to produce SPR-CT images of each plug. Second, independent elemental composition analysis of the PLA plastic was used to determine the Zeff and ρe for calculating the theoretical SPR (SPR-TH) using the Bethe-Bloch equation. Finally, for each plug, a direct measurement of SPR (SPR-DM) was obtained in a clinical proton beam. The values of SPR-CT, SPR-TH, and SPR-DM were compared. RESULTS: The SPR-CT for PLA agreed with SPR-DM for tsepta  ≥ 3 mm (for CT slice thicknesses of 0.5, 1.0, and 3.0 mm). The density of PLA was found to decrease with thickness when tsepta  < 3 mm. As tsepta (and density) decreased, the SPR-CT values also decreased, in good agreement with SPR-DM and SPR-TH. CONCLUSION: Overall, the DECT-based SPR-CT was within 3% of SPR-TH and SPR-DM in the high-density gradient regions of the 3D-printed plugs for septa greater than ~ 3mm in thickness.


Subject(s)
Air , Phantoms, Imaging , Printing, Three-Dimensional , Protons , Tomography, X-Ray Computed/instrumentation
2.
J Radioanal Nucl Chem ; 318(1): 241-246, 2018 Oct.
Article in English | MEDLINE | ID: mdl-31327884

ABSTRACT

This work explores a novel tomographic approach to PGAA that is both quantitative and spatially resolved, adapted from a clinical "proton beam range finder" in which MeV gamma rays are imaged by coincidence measurements of Compton scattered gamma rays with multi-detector arrays. We performed preliminary measurements using a Compton camera made with CdZnTe detector arrays on a series of test samples with high-energy (> 1 MeV) gamma emission lines. 3D image reconstructions were performed on the 2.2 MeV peak from H. The image reconstruction methods were also evaluated using the emission data generated by Monte Carlo simulations under ideal conditions.

3.
Med Phys ; 44(3): 974-985, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28060414

ABSTRACT

PURPOSE: Computed Tomography (CT) imaging of the lung, reported in Hounsfield Units (HU), can be parameterized as a quantitative image biomarker for the diagnosis and monitoring of lung density changes due to emphysema, a type of chronic obstructive pulmonary disease (COPD). CT lung density metrics are global measurements based on lung CT number histograms, and are typically a quantity specifying either the percentage of voxels with CT numbers below a threshold, or a single CT number below which a fixed relative lung volume, nth percentile, falls. To reduce variability in the density metrics specified by CT attenuation, the Quantitative Imaging Biomarkers Alliance (QIBA) Lung Density Committee has organized efforts to conduct phantom studies in a variety of scanner models to establish a baseline for assessing the variations in patient studies that can be attributed to scanner calibration and measurement uncertainty. METHODS: Data were obtained from a phantom study on CT scanners from four manufacturers with several protocols at various tube potential voltage (kVp) and exposure settings. Free from biological variation, these phantom studies provide an assessment of the accuracy and precision of the density metrics across platforms solely due to machine calibration and uncertainty of the reference materials. The phantom used in this study has three foam density references in the lung density region, which, after calibration against a suite of Standard Reference Materials (SRM) foams with certified physical density, establishes a HU-electron density relationship for each machine-protocol. We devised a 5-step calibration procedure combined with a simplified physical model that enabled the standardization of the CT numbers reported across a total of 22 scanner-protocol settings to a single energy (chosen at 80 keV). A standard deviation was calculated for overall CT numbers for each density, as well as by scanner and other variables, as a measure of the variability, before and after the standardization. In addition, a linear mixed-effects model was used to assess the heterogeneity across scanners, and the 95% confidence interval of the mean CT number was evaluated before and after the standardization. RESULTS: We show that after applying the standardization procedures to the phantom data, the instrumental reproducibility of the CT density measurement of the reference foams improved by more than 65%, as measured by the standard deviation of the overall mean CT number. Using the lung foam that did not participate in the calibration as a test case, a mixed effects model analysis shows that the 95% confidence intervals are [-862.0 HU, -851.3 HU] before standardization, and [-859.0 HU, -853.7 HU] after standardization to 80 keV. This is in general agreement with the expected CT number value at 80 keV of -855.9 HU with 95% CI of [-857.4 HU, -854.5 HU] based on the calibration and the uncertainty in the SRM certified density. CONCLUSIONS: This study provides a quantitative assessment of the variations expected in CT lung density measures attributed to non-biological sources such as scanner calibration and scanner x-ray spectrum and filtration. By removing scanner-protocol dependence from the measured CT numbers, higher accuracy and reproducibility of quantitative CT measures were attainable. The standardization procedures developed in study may be explored for possible application in CT lung density clinical data.


Subject(s)
Calibration , Lung/diagnostic imaging , Tomography Scanners, X-Ray Computed/standards , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/standards , Humans , Lung/physiology , Models, Anatomic , Models, Theoretical , Phantoms, Imaging , Reproducibility of Results , Tomography, X-Ray Computed/methods , Uncertainty