Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 82
Filter
1.
Neurol India ; 70(3): 1041-1047, 2022.
Article in English | MEDLINE | ID: mdl-35864636

ABSTRACT

Background/Purpose: Following endovascular intervention for stroke, hyperattenuated areas are common in brain parenchyma and it is difficult to differentiate on non-contrast CT whether it is contrast staining or reperfusion hemorrhage. Differentiation between contrast staining from reperfusion hemorrhage is of paramount importance for early initiation of antiplatelets and/or anticoagulants to prevent reocclusion of vessel. This study demonstrates signal characteristics of contrast-staining and reperfusion hemorrhage on susceptibility weighted MRI and its role to differentiate between two. Materials/Methods: Between July 2017 to March 2019, 36 patients who presented with acute ischemic stroke due to large vessel occlusion underwent mechanical thrombectomy. Low-osmolar non-ionic (Iopromide 300 mg/L) iodinated contrast was used in all patients who underwent endovascular intervention. All patients underwent noncontrast CT brain and SWI on 3T MRI within 30 minutes of endovascular intervention. MRI was evaluated by two neuroradiologists. Reperfusion hemorrhage was defined as ECASS criteria II. Symptomatic ICH was defined as hemorrhagic transformation temporally related to a negative shift in NIHSS score >/=4. Results: Out of 36 patients, 15 had hyperattenuated areas in brain on NCCT. Out of 15, 13 patients had blooming on SWI, suggestive of bleed. Two patients had no blooming on SWI, suggestive of contrast staining. Two patients didnot show any hyperdensity on NCCT but blooming on SWI, suggestive of bleed. Conclusion: All patients with hyperdensity on NCCT secondary to bleed showed blooming on SWI whereas those with contrast staining didnot show any signal changes on SWI. Thus, it is possible to differentiate reperfusion hemorrhage from contrast staining using SWI MRI. The significance of SWI in normal CT may be low where a small bleed maynot have any clinical significance.


Subject(s)
Brain Ischemia , Ischemic Stroke , Reperfusion Injury , Stroke , Brain Ischemia/diagnostic imaging , Humans , Ischemic Stroke/diagnostic imaging , Ischemic Stroke/surgery , Magnetic Resonance Imaging , Reperfusion Injury/diagnostic imaging , Retrospective Studies , Stroke/diagnostic imaging , Stroke/surgery , Thrombectomy/adverse effects , Treatment Outcome
2.
Ann Hepatobiliary Pancreat Surg ; 23(2): 187-191, 2019 May.
Article in English | MEDLINE | ID: mdl-31225423

ABSTRACT

Arterio-portal fistulas (APFs) are characterized by anomalous communication between arteries and the portal vein (PV) system. Treatment of APF is imperative as an emergency or if there is development of portal hypertension/heart failure in chronic cases. Both endovascular and surgical managements can be attempted, however since endovascular management carries comparatively low intra and post procedural morbidity it is mostly preferred. This is a case report on endovascular management of post-traumatic pseudoaneurysm arising from bifurcation of common hepatic artery with complete disruption of the gastroduodenal artery and high-flow APF. This report describes the intraprocedure challenges in exclusion of fistula from the circulation, without disruption of portal system and anticipation of recruitment of new collateral feeders to the fistula immediate post exclusion with its embolization, which needs appropriate positioning of the catheter prior to exclusion of the fistula.

3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 2810-2813, 2017 Jul.
Article in English | MEDLINE | ID: mdl-29060482

ABSTRACT

In neonatal intensive care units performing continuous EEG monitoring, there is an unmet need for around-the-clock interpretation of EEG, especially for recognizing seizures. In recent years, a few automated seizure detection algorithms have been proposed. However, these are suboptimal in detecting brief-duration seizures (<; 30s), which frequently occur in neonates with severe neurological problems. Recently, a multi-stage neonatal seizure detector, composed of a heuristic and a data-driven classifier was proposed by our group and showed improved detection of brief seizures. In the present work, we propose to add a third stage to the detector in order to use feedback of the Clinical Neurophysiologist and adaptively retune a threshold of the second stage to improve the performance of detection of brief seizures. As a result, the false alarm rate (FAR) of the brief seizure detections decreased by 50% and the positive predictive value (PPV) increased by 18%. At the same time, for all detections, the FAR decreased by 35% and PPV increased by 5% while the good detection rate remained unchanged.


Subject(s)
Seizures , Algorithms , Electroencephalography , Heuristics , Humans , Infant, Newborn , Infant, Newborn, Diseases
4.
Clin Transplant ; 31(3)2017 03.
Article in English | MEDLINE | ID: mdl-27935642

ABSTRACT

AIM: The aim of this study was to evaluate long-term health-related quality of life (HRQOL), changes in lifestyle, and complications in living liver donors at a single transplant center from southern India. METHODS: A total of 64 consecutive living liver donors from 2008 to 2011 were evaluated; 46 of 64 donors completed the short form 36 (SF-36) via telephonic interviews or clinic consultations. Mean follow-up was 48 months (range: 37-84 months). RESULTS: There was no mortality in the donors evaluated. Overall morbidity was 23%, which included wound infections (4.3%), incisional hernia (2.1%), biliary leak (4.3%), and nonspecific complaints regarding the incision site (15.2%). All 46 donors who completed the SF-36 had no change in career path or predonation lifestyle. A total of 40 of 46 (87%) donors had no limitations, decrements, or disability in any domain, while six of 46 (13%) had these in some domains of which general health (GH) was most severely affected. CONCLUSIONS: Living donor hepatectomy is safe with acceptable morbidity and excellent long-term HRQOL with no change in career path or significant alteration of lifestyle for donors.


Subject(s)
Liver Transplantation , Living Donors , Quality of Life , Tissue and Organ Harvesting , Adult , Female , Humans , India , Male , Middle Aged , Surveys and Questionnaires , Time Factors , Young Adult
6.
Clin Neurophysiol ; 127(9): 3014-3024, 2016 09.
Article in English | MEDLINE | ID: mdl-27472536

ABSTRACT

OBJECTIVE: After identifying the most seizure-relevant characteristics by a previously developed heuristic classifier, a data-driven post-processor using a novel set of features is applied to improve the performance. METHODS: The main characteristics of the outputs of the heuristic algorithm are extracted by five sets of features including synchronization, evolution, retention, segment, and signal features. Then, a support vector machine and a decision making layer remove the falsely detected segments. RESULTS: Four datasets including 71 neonates (1023h, 3493 seizures) recorded in two different university hospitals, are used to train and test the algorithm without removing the dubious seizures. The heuristic method resulted in a false alarm rate of 3.81 per hour and good detection rate of 88% on the entire test databases. The post-processor, effectively reduces the false alarm rate by 34% while the good detection rate decreases by 2%. CONCLUSION: This post-processing technique improves the performance of the heuristic algorithm. The structure of this post-processor is generic, improves our understanding of the core visually determined EEG features of neonatal seizures and is applicable for other neonatal seizure detectors. SIGNIFICANCE: The post-processor significantly decreases the false alarm rate at the expense of a small reduction of the good detection rate.


Subject(s)
Electroencephalography/methods , Heuristics , Infant, Newborn, Diseases/diagnosis , Infant, Newborn, Diseases/physiopathology , Seizures/diagnosis , Seizures/physiopathology , Databases, Factual/standards , Electroencephalography/standards , Heuristics/physiology , Humans , Infant, Newborn , Retrospective Studies , Support Vector Machine/standards
7.
Bioinformation ; 12(3): 149-155, 2016.
Article in English | MEDLINE | ID: mdl-28232775

ABSTRACT

Heat Shock Protein 90 was a key molecular chaperone involved in the proteome stability maintenance and its interference in many signaling networks associated with cancer progression, makes it of an important target for cancer therapeutics. The present study aimed to identify potential lead molecule among the selected heterocyclic compounds against Human Hsp90 (PDB: 1YET) through docking using GOLD 3.1 and pharmacophore studies using Discovery studio 2.1. On the basis of the GOLD Fitness scores, the compounds Q1G and T21 showed better binding affinity. Further the analyzed structure pharmacophore results are in consistence with the docking results indicating that both these compounds show antagonistic activity towards HSP90 respectively.

8.
J Plast Reconstr Aesthet Surg ; 69(1): 101-7, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26507862

ABSTRACT

In this study, radiographic assessment was performed to find out the effectiveness of bone regeneration following the application of recombinant human bone morphogenetic protein 7 (rhBMP-7) for the reconstruction of alveolar cleft defects in 11 cases: nine unilateral and two bilateral alveolar clefs. Reconstruction of the alveolar cleft was performed by using 3.5 mg of rhBMP-7 (Osigraft OP1) on a type I collagen carrier. Radiographs were taken 6 months post operation using a Gendex Intraoral Unit with Agfa Dentus M2 Comfort occlusal film. The amount of bony infill was graded on a Kindelan four-point scale. The patients were followed up for an average of 6.6 years. Based on the radiographic analysis, eight out of the nine unilateral alveolar cleft cases received a score of grade I and one patient had a grade II score, using the Kindelan scale. In the two bilateral alveolar clefts, only one side had bone formation. The radiographic appearance showed a normal trabecular pattern similar to the adjacent bone. Thus, rhBMP-7 was radiographically and clinically successful in regenerating the bone at the alveolar cleft which resulted in shortening of the operation time, absence of donor-site morbidity and a shorter hospital stay. The promising results of this preliminary study should encourage a phase II trial to compare bone grafts with BMP for the reconstruction of alveolar defects.


Subject(s)
Alveolar Ridge Augmentation/methods , Bone Morphogenetic Protein 7/pharmacology , Cleft Palate/surgery , Plastic Surgery Procedures/methods , Child , Cleft Lip/surgery , Female , Humans , Male , Recombinant Proteins
9.
Pediatr Transplant ; 19(3): E56-61, 2015 May.
Article in English | MEDLINE | ID: mdl-25655683

ABSTRACT

Pediatric LDLT using donors with unfavorable vascular anatomy is challenging in terms of donor safety, and complexity of reconstruction in the recipient. We describe an innovative technique of hepatic venous outflow reconstruction involving the recipient RHV, in the presence of a rudimentary RHV in the donor. The postoperative course of the donor and recipient was uneventful with satisfactory venous outflow in both. This technique avoided the use of prosthetic material, an important consideration given the recipient age and requirement for growth. This shows that donors previously considered unsuitable for donation can be utilized safely as long as principles of vascular anastomosis are adhered to. Moreover, it highlights that innovation is sometimes necessary to avoid compromise in donor safety.


Subject(s)
Hepatic Veins/surgery , Liver Failure, Acute/surgery , Liver Transplantation/methods , Liver/blood supply , Algorithms , Anastomosis, Surgical , Child , Hepatectomy/methods , Humans , Liver Failure , Living Donors , Male , Postoperative Period , Plastic Surgery Procedures/methods , Risk
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 5859-62, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26737624

ABSTRACT

Visual recognition of neonatal seizures during continuous EEG monitoring in neonatal intensive care units (NICUs) is labor-intensive, has low inter-rater agreement and requires special expertise that is not available around the clock. Development of an accurate automated seizure detection system with a low false alarm rate will support clinical decision making and alleviate significantly the workload. However, this is an ongoing difficult challenge for engineers as the neonatal EEG signal is non-stationary and often includes complex patterns of seizures and artifacts. In this study, we show an improvement of our previously developed neonatal seizure detector (developed using heuristic if-then rules). In order to improve the detection accuracy, mean phase coherence as a new feature is used to characterize artifacts and also support vector machine is applied to perform the post-processing step to remove false detections. As a result, the false alarm rate drops 42% (from 2.6 h(-1) to 1.5 h(-1)), whereas the good detection rate reduces only by 4%.


Subject(s)
Seizures , Algorithms , Artifacts , Electroencephalography , Humans , Infant, Newborn , Infant, Newborn, Diseases , Support Vector Machine
11.
World J Gastroenterol ; 20(37): 13369-81, 2014 Oct 07.
Article in English | MEDLINE | ID: mdl-25309070

ABSTRACT

Despite inception over 15 years ago and over 3000 completed procedures, laparoscopic liver resection has remained mainly in the domain of selected centers and enthusiasts. Requirement of extensive open liver resection (OLR) experience, in-depth understanding of anatomy and considerable laparoscopic technical expertise may have delayed wide application. However healthy scepticism of its actual benefits and presence of a potential publication bias; concern about its safety and technical learning curve, are probably equally responsible. Given that a large proportion of our work, at least in transplantation is still OLR, we have attempted to provide an entirely unbiased, mature opinion of its pros and cons in the current invited review. We have divided this review into two sections as we believe they merit separate attention on technical and ethical grounds. The first part deals with laparoscopic liver resection (LLR) in patients who present with benign or malignant liver pathology, wherein we have discussed its overall outcomes; its feasibility based on type of pathology and type of resection and included a small section on application of LLR in special scenarios like cirrhosis. The second part deals with the laparoscopic living donor hepatectomy (LDH) experience to date, including its potential impact on transplantation in general. Donor safety, graft outcomes after LDH and criterion to select ideal donors for LLR are discussed. Within each section we have provided practical points to improve safety in LLR and attempted to reach reasonable recommendations on the utilization of LLR for units that wish to develop such a service.


Subject(s)
Hepatectomy/methods , Laparoscopy , Liver Transplantation/methods , Living Donors , Hepatectomy/adverse effects , Humans , Laparoscopy/adverse effects , Liver Transplantation/adverse effects , Postoperative Complications/etiology , Risk Factors , Treatment Outcome
12.
Heart Lung Circ ; 23(1): e16-9, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23948290

ABSTRACT

Papillary muscle rupture is now a rare complication of acute myocardial infarction. Posteromedial papillary muscle rupture is more common than anterolateral papillary muscle rupture. The posteromedial papillary muscle is usually supplied from a branch of the right coronary artery. We present a case of posteromedial papillary muscle rupture due to an isolated left anterior descending artery lesion. This was diagnosed on the fifth day post infarction. The patient progressed to mitral valve replacement and coronary artery bypass grafting to the left anterior descending artery. We believe this unusual arterial supply to the posteromedial papillary muscle is due to an apex forming left anterior descending artery coupled with an apically located posteromedial papillary muscle.


Subject(s)
Coronary Vessels , Heart Valve Prosthesis Implantation , Mitral Valve , Myocardial Infarction , Papillary Muscles , Aged , Coronary Vessels/pathology , Coronary Vessels/surgery , Humans , Male , Mitral Valve/pathology , Mitral Valve/surgery , Myocardial Infarction/complications , Myocardial Infarction/pathology , Myocardial Infarction/surgery , Papillary Muscles/pathology , Papillary Muscles/surgery , Rupture, Spontaneous
13.
Liver Transpl ; 18(1): 82-8, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22006832

ABSTRACT

Liver transplantation (LT) for human immunodeficiency virus (HIV)-positive recipients with end-stage liver disease has become an accepted practice. However, because these patients are increasingly being recognized as prothrombotic, we reviewed their posttransplant thrombotic complications. Because morphological changes might be responsible in part for this prothrombotic state, we also conducted a histopathological review of explants from HIV-positive patients. Between 1990 and 2010, 24 of 3502 recipients (including 23 adults) were HIV-positive at LT. These patients and their postoperative courses were reviewed with a particular focus on vascular complications, risk factors, and outcomes. Another patient in whom HIV was detected 12 years after LT was also examined. Among the 24 HIV-positive LT recipients (17 males and 22 whole liver grafts; median age = 40 years), 5 developed arterial complications [including 3 cases of hepatic artery thrombosis (HAT), 1 case of generalized arteriopathy (on angiography), and 1 case of endoarteritis (on histological analysis)]. Multiple arterial anastomoses were performed in 8 of the 24 recipients, and HAT occurred twice within this anastomosis group. The outcomes of the 3 patients with HAT included retransplantation, biliary stenting for ischemic cholangiopathy followed by retransplantation, and observation only. In addition, 5 separate venous thrombotic events were detected in the 24 recipients during this period. Moreover, the delayed-HIV recipient developed delayed HAT and subsequently ischemic cholangiopathy and was being assessed for retransplantation at the time of this writing. In conclusion, the prothrombotic state associated with combined HIV and liver disease is a cause of morbidity after LT: 8 of the 24 recipients (33%) in this series suffered vascular thrombotic complications. There is a potential increase in the risk of HAT: the rate for the HIV-positive cohort was higher than the rate for historical HIV-negative controls [12% versus 3.2%, P = 0.016 (Fisher's exact test)]. The minimization of complex arterial reconstruction, coagulopathy screening, and risk-adapted antithrombotic chemoprophylaxis appear to be reasonable precautions.


Subject(s)
Fibrinolytic Agents/therapeutic use , HIV Infections/complications , HIV Infections/surgery , Liver Diseases/surgery , Liver Diseases/virology , Liver Transplantation , Thrombosis/prevention & control , Adult , Child , Cohort Studies , Female , Humans , Incidence , Kaplan-Meier Estimate , Liver/pathology , Liver/surgery , Liver/virology , Longitudinal Studies , Male , Retrospective Studies , Risk Factors , Survival Rate , Thrombosis/epidemiology , Thrombosis/mortality , Treatment Outcome , Vascular Diseases/epidemiology , Vascular Diseases/mortality , Vascular Diseases/prevention & control
14.
Clin Neurophysiol ; 122(12): 2345-54, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21705269

ABSTRACT

OBJECTIVE: The description and evaluation of algorithms using Independent Component Analysis (ICA) for automatic removal of ECG, pulsation and respiration artifacts in neonatal EEG before automated seizure detection. METHODS: The developed algorithms decompose the EEG using ICA into its underlying sources. The artifact source was identified using the simultaneously recorded polygraphy signals after preprocessing. The EEG was reconstructed without the corrupting source, leading to a clean EEG. The impact of the artifact removal was measured by comparing the performance of a previously developed seizure detector before and after the artifact removal in 13 selected patients (9 having artifact-contaminated and 4 having artifact-free EEGs). RESULTS: A significant decrease in false alarms (p=0.01) was found while the Good Detection Rate (GDR) for seizures was not altered (p=0.50). CONCLUSIONS: The techniques reduced the number of false positive detections without lowering sensitivity and are beneficial in long term EEG seizure monitoring in the presence of disturbing biological artifacts. SIGNIFICANCE: The proposed algorithms improve neonatal seizure monitoring.


Subject(s)
Algorithms , Artifacts , Electroencephalography/methods , Seizures/diagnosis , Humans , Infant, Newborn , Sensitivity and Specificity
15.
Clin Neurophysiol ; 122(8): 1490-9, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21396883

ABSTRACT

OBJECTIVE: To validate an improved automated electroencephalography (EEG)-based neonatal seizure detection algorithm (NeoGuard) in an independent data set. METHODS: EEG background was classified into eight grades based on the evolution of discontinuity and presence of sleep-wake cycles. Patients were further sub-classified into two groups; gpI: mild to moderate (grades 1-5) and gpII: severe (grades 6-8) EEG background abnormalities. Seizures were categorised as definite and dubious. Seizure characteristics were compared between gpI and gpII. The algorithm was tested on 756 h of EEG data from 24 consecutive neonates (median 25 h per patient) with encephalopathy and recorded seizures during continuous monitoring (cEEG). No selection was made regarding the quality of EEG or presence of artefacts. RESULTS: Seizure amplitudes significantly decreased with worsening EEG background. Seizures were detected with a total sensitivity of 61.9% (1285/2077). The detected seizure burden was 66,244/97,574 s (67.9%). Sensitivity per patient was 65.9%, with a mean positive predictive value (PPV) of 73.7%. After excluding four patients with severely abnormal EEG background, and predominantly having dubious seizures, the algorithm showed a median sensitivity per patient of 86.9%, PPV of 89.5% and false positive rate of 0.28 h(-1). Sensitivity tended to be better for patients in gpI. CONCLUSIONS: The algorithm detects neonatal seizures well, has a good PPV and is suited for cEEG monitoring. Changes in electrographic characteristics such as amplitude, duration and rhythmicity in relation to deteriorating EEG background tend to worsen the performance of automated seizure detection. SIGNIFICANCE: cEEG monitoring is important for detecting seizures in the neonatal intensive care unit (NICU). Our automated algorithm reliably detects neonatal seizures that are likely to be clinically most relevant, as reflected by the associated EEG background abnormality.


Subject(s)
Brain Waves/physiology , Electroencephalography/methods , Electronic Data Processing/methods , Seizures/diagnosis , Algorithms , Female , Humans , Infant , Infant, Newborn , Male , Reproducibility of Results , Retrospective Studies , Seizures/physiopathology
16.
JOP ; 12(1): 32-6, 2011 Jan 05.
Article in English | MEDLINE | ID: mdl-21206098

ABSTRACT

CONTEXT: With patients surviving longer after pancreatic resection, the challenges now is the management of the unresolved longer-term issues. CASE REPORT: A 53-year-old woman with painless obstructive jaundice, underwent a pylorous preserving pancreaticoduodenectomy for a pT3N0M0 ampullary adenocarcinoma in 2001 (patchy chronic pancreatitis with mucinous metaplasia of background pancreatic duct epithelium and acinar atrophy were noted). Despite adjuvant chemotherapy, at month 54 she required a pulmonary wedge resection for metastatic adenocarcinoma, followed by a pulmonary relapse at 76 months when she underwent 6 neoadjuvant cycles of gemcitabine/capecitabine and a left pneumonectomy. Finally 7 years after the initial Whipple's, a single 18F fluorodeoxyglucose (FDG) avid pancreatic tail lesion led to completion pancreatectomy for a well-differentiated ductal adenocarcinoma with clear resection margins albeit peripancreatic adipose tissue infiltration. On review all resected tumour cells had identical immunophenotype (CK7+/CK20-/MUC1+/MUC2-) as that of the primary. She is currently asymptomatic on follow-up. CONCLUSIONS: These findings suggest that in selected cases even in the presence of pulmonary metastasis, repeat resections could result in long-term survival of patients with metachronous ampullary cancer. Second, even ampullary tumours maybe should be regarded as index tumors in the presence of ductal precursor lesions in the resection specimen. Three distant metastases, particularly if long after the initial tumour, should instigate a search for metachronous tumour, especially in the presence of field change in the initial specimen. Risk-adapted follow-up protocols with recognition of such factors could result in cost-effective surveillance and potentially improved outcomes.


Subject(s)
Adenocarcinoma/secondary , Lung Neoplasms/secondary , Neoplasms, Second Primary/pathology , Pancreatic Neoplasms/pathology , Pancreatic Neoplasms/surgery , Adenocarcinoma/drug therapy , Adenocarcinoma/surgery , Chemotherapy, Adjuvant , Combined Modality Therapy , Female , Humans , Lung Neoplasms/drug therapy , Lung Neoplasms/surgery , Middle Aged , Neoplasms, Second Primary/diagnosis , Pancreaticoduodenectomy , Pneumonectomy , Treatment Outcome
17.
HPB (Oxford) ; 12(6): 389-95, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20662789

ABSTRACT

OBJECTIVES: The reported median diagnostic yield from endoscopic ultrasound (EUS) fine-needle aspiration (FNA) cytology is 78% (range 39-93%). The aim of this study is to describe a single-centre experience in the diagnostic work-up of solid pancreatic and peripancreatic masses without the benefit of an onsite cytopathologist. METHODS: In a consecutive series of 429 EUS examinations performed over a 12-month period by a single operator, 108 were on non-cystic pancreatic or biliary lesions. Data were collected prospectively and the accuracy of FNA was assessed retrospectively using either surgery or repeat imaging as the benchmark in the presence or absence of malignancy. RESULTS: Of the 108 FNAs, 102 (94%) were diagnostic, four were falsely negative (FN) and two were atypical and considered equivocal. There were 78 pancreatic lesions, of which 65 were true positives (TP), 11 true negatives (TN) and two FN, giving an overall accuracy of 97% (76/78). Of nine periampullary lesions, two were TP, six were TN and one was FN, giving an overall accuracy of 89% (8/9). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of EUS-FNA for pancreatic and periampullary lesions combined were 96%, 100%, 100% [95% confidence interval (CI) 95-100%], 85% (95% CI 62-97%) and 97%, respectively. There were 21 bile duct lesions, of which 10 were TP, eight TN, two atypical and one FN, giving an overall accuracy of 86% (18/21). The sensitivity, specificity, PPV, NPV and accuracy of EUS-FNA for biliary lesions were 91%, 100%, 100% (95% CI 69-100%), 91% (95% CI 59-100%) and 95%, respectively. CONCLUSIONS: The diagnostic accuracy of EUS-FNA for pancreatic lesions in our series was 97% and the PPV for the three subgroups of lesion type was 100%; these figures are comparable with the best rates reported in the literature, despite the absence of onsite cytopathology. These rates are potentially a direct result of high-volume practice, dedicated endosonography and cytopathology. These results show that it is possible to achieve high rates of accuracy in places where logistical issues make it impossible to maintain a cytopathologist in the endoscopy suite. In addition, our results contribute to the limited, collective global experience on the effectiveness of EUS-FNA in periampullary and biliary lesions.


Subject(s)
Biopsy, Fine-Needle , Endosonography , Pancreas/pathology , Pancreatic Neoplasms/diagnosis , Ultrasonography, Interventional/methods , England , False Negative Reactions , Humans , Pancreas/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Predictive Value of Tests , Prognosis , Retrospective Studies , Sensitivity and Specificity
18.
Methods Inf Med ; 49(5): 473-8, 2010.
Article in English | MEDLINE | ID: mdl-20526524

ABSTRACT

BACKGROUND: A common cause for damage to the neonatal brain is a shortage in the oxygen supply to the brain or asphyxia. Neonatal seizures are the most frequent manifestation of neonatal neurologic disorders. Multichannel EEG recordings allow topographic localization of seizure foci. OBJECTIVES: We want to objectively determine the spatial distribution of the seizure on the scalp, the location in time and order the dominant sources in the brain based on their strength. METHODS: In this paper we combine a method based on higher order CP-decomposition with subsequent singular value decomposition (SVD). RESULTS: We illustrate the abilities of the method on simulated as well as on real neonatal seizure EEG. CONCLUSIONS: The proposed method provides reliable time and spatial information about the seizure, gives a clear overview of what is going on in the EEG and allows easy interpretation.


Subject(s)
Electroencephalography/methods , Models, Neurological , Seizures/classification , Signal Processing, Computer-Assisted , Algorithms , Asphyxia Neonatorum/complications , Humans , Infant, Newborn , Seizures/diagnosis , Seizures/etiology
19.
Liver Transpl ; 16(6): 742-7, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20517908

ABSTRACT

In the presence of anatomical variants such as an accessory or replaced (A/R) right hepatic artery (RHA), a conflict of interest can arise during organ retrieval between liver and pancreatic teams. This angiographic study examines the anatomy of the inferior pancreaticoduodenal artery (IPDA), its relation to the A/R RHA, and the implications for the use of livers and pancreases from multiorgan donors. Gastrointestinal angiograms performed in our institution for unrelated indications were reviewed, and the relevant arteries, their diameters, the distances between origins, the time at which variants were found, and the blood supply to relevant solid organs were recorded. A review of 122 angiograms identified 100 patients in whom both the superior mesenteric artery (SMA) and the celiac axis were cannulated synchronously; these patients composed our study cohort. The IPDA was identified in 95% of the cases. There were 8 patients with a replaced RHA and 4 with an accessory RHA. In all 12, the IPDA had an SMA origin; 3 of these shared a common origin with the A/R RHA on the SMA. In the rest, the mean distance between them was 29 mm (range = 17.8-48.3 mm). All anomalous arteries found were segmental vessels. In conclusion, the A/R RHA incidence in our series was 12%, and no case had an IPDA originating from the A/R RHA. Separate accessory RHA and IPDA origins potentially allow an uncompromised accessory RHA (with its Carrel patch) without risk of prejudice to the pancreatic graft if retrieval is accurately performed. Rarely (3%), there is a common origin between the A/R RHA and the IPDA, and back-bench reconstruction would be required to allow the use of both the liver and pancreas.


Subject(s)
Angiography, Digital Subtraction , Hepatic Artery/diagnostic imaging , Hepatic Artery/surgery , Liver/blood supply , Liver/surgery , Pancreas/blood supply , Pancreas/surgery , Tissue and Organ Harvesting , Adult , Aged , Aged, 80 and over , Celiac Artery/diagnostic imaging , Celiac Artery/surgery , Female , Hepatic Artery/abnormalities , Humans , Liver Transplantation , Male , Mesenteric Artery, Superior/diagnostic imaging , Mesenteric Artery, Superior/surgery , Middle Aged , Pancreas Transplantation , Retrospective Studies , Tissue Donors/supply & distribution , Young Adult
20.
Surg Endosc ; 24(8): 2031-8, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20177941

ABSTRACT

BACKGROUND: Gastric band erosion is a well-reported complication after laparoscopic adjustable gastric banding (LAGB). The published literature is limited and inconclusive with regard to its management. The authors therefore reviewed all band erosions detected during a 5-year period in a high-volume bariatric practice. Because a significant proportion of the band insertions (65%) were undertaken by an operator beyond his learning curve, the authors hoped to gain a mature, comprehensive understanding of this significant complication. METHODS: The authors retrospectively reviewed the operative log of the operating theaters in their obesity surgery unit to find all the operations performed on LAGB patients for erosion from January 2003 to December 2007. The clinical notes and electronic records for each patient were reviewed. These data were cross-referenced against the authors' obesity surgery database, and denominator data such as the total number operations performed and demographics were found. Finally, postoperative outcomes were collated from the outpatient follow-up data and telephonic interviews, and the results were analyzed. RESULTS: From January 2003 to December 2007, a single surgeon performed 865 LAGBs in the authors' unit. The authors identified 18 operations performed for LAGB erosions. The 18 patients (one referred from elsewhere, 14 women) formed the final study cohort (median preoperative body mass index [BMI], 46 kg/m(2)). Of the 17 erosions, 15 occurred relatively early in the series. The patients with the 213 Swedish adjustable gastric bands experienced 12 erosions (incidence, 5.6%) compared with 6 erosions with the 652 LAP-BANDs (incidence, 0.9%). The median time to presentation was 7 months (range, 1-60 months). However, 55% of the erosions (n = 10) occurred within the first year, and only 10% occurred after the second year. The most common presenting symptom was pain followed by weight regain. None of the patients experienced peritonitis. After surgical management of the erosion, three patients had a second LAGB and at this writing are well. Of the remaining patients, 11 are well, but 6 of these patients have returned to their previous weight (4 patients were lost to follow-up evaluation). CONCLUSIONS: The overall incidence of LAGB erosions in our series was 1.96%. This incidence fell with increasing experience to 0.5% after the initial 300 bands were excluded from the analysis (3 band erosions in the last 565 band insertions). However, further increases in incidence are likely with a longer follow-up period. The most common presentation was abdominal pain followed by weight regain and port-site sepsis. In the authors' hands, laparoscopic omental plugging and band removal through a separate anterior gastrotomy appear to be effective methods for dealing with band erosions. Band erosion is a significant source of morbidity, with at least one-third of the erosion patients in our series not achieving their final goal of weight loss despite appropriate treatment. This study highlights the need for a future prospective randomized study to clarify the apparent strong influence of band design and construction on the etiopathogenesis of band erosion.


Subject(s)
Gastroplasty/adverse effects , Gastroplasty/methods , Laparoscopy , Adult , Aged , Female , Gastroplasty/instrumentation , Humans , Male , Middle Aged , Postoperative Complications/etiology , Postoperative Complications/therapy , Retrospective Studies , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL