Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
1.
Am J Cardiol ; 176: 105-111, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35641348

ABSTRACT

New-onset left bundle branch block (NLBBB) is the most common complication after transcatheter aortic valve implantation (TAVI). Expert consensus recommends temporary transvenous pacemaker (TTVP) support for 24 hours in these patients. To date, no study has examined TTVP use during the index hospitalization in detail. Therefore, we aimed to assess TTVP use in patients with TAVI who developed NLBBB. In this prospective observational study, we performed a detailed analysis of 24-hour telemetry in patients who developed NLBBB during TAVI. Baseline characteristics and procedural and postprocedural data were recorded. The primary outcome was pacing by the TTVP. We evaluated inappropriate TTVP use, electrophysiology study findings, permanent pacemaker (PPM) implantation, and NLBBB resolution. A total of 83 patients (74.4 ± 8.7 years, 41% female) developed NLBBB during TAVI. During index hospitalization, 1 patient (1%) required TTVP because of complete heart block and received a PPM. Five of the 83 (6%) patients were inappropriately paced, and 1 patient (1%) had ventricular fibrillation, likely secondary to TTVP. A total of 34 patients (41%) underwent electrophysiology study during hospitalization, with 4 of 83 (5%) subsequently receiving a PPM. One (1%) patient died during hospitalization, and 9 patients were lost to follow-up because of the COVID-19 pandemic. Of the remaining 73 patients with a 30-day follow-up, NLBBB had resolved in 36 (49%) at 30 days, and 2 (3%) were readmitted with complete heart block and received PPM. In conclusion, in patients with TAVI who develop NLBBB, temporary pacing is rarely necessary, may carry additional risks to the patient, and prolong hospitalization time.


Subject(s)
Aortic Valve Stenosis , Atrioventricular Block , COVID-19 , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Arrhythmias, Cardiac/therapy , Atrioventricular Block/etiology , Bundle-Branch Block/epidemiology , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , COVID-19/epidemiology , Cardiac Pacing, Artificial/adverse effects , Female , Humans , Male , Pacemaker, Artificial/adverse effects , Pandemics , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
2.
Nat Med ; 28(2): 295-302, 2022 02.
Article in English | MEDLINE | ID: mdl-35177859

ABSTRACT

Complex diseases, such as coronary artery disease (CAD), are often multifactorial, caused by multiple underlying pathological mechanisms. Here, to study the multifactorial nature of CAD, we performed comprehensive clinical and multi-omic profiling, including serum metabolomics and gut microbiome data, for 199 patients with acute coronary syndrome (ACS) recruited from two major Israeli hospitals, and validated these results in a geographically distinct cohort. ACS patients had distinct serum metabolome and gut microbial signatures as compared with control individuals, and were depleted in a previously unknown bacterial species of the Clostridiaceae family. This bacterial species was associated with levels of multiple circulating metabolites in control individuals, several of which have previously been linked to an increased risk of CAD. Metabolic deviations in ACS patients were found to be person specific with respect to their potential genetic or environmental origin, and to correlate with clinical parameters and cardiovascular outcomes. Moreover, metabolic aberrations in ACS patients linked to microbiome and diet were also observed to a lesser extent in control individuals with metabolic impairment, suggesting the involvement of these aberrations in earlier dysmetabolic phases preceding clinically overt CAD. Finally, a metabolomics-based model of body mass index (BMI) trained on the non-ACS cohort predicted higher-than-actual BMI when applied to ACS patients, and the excess BMI predictions independently correlated with both diabetes mellitus (DM) and CAD severity, as defined by the number of vessels involved. These results highlight the utility of the serum metabolome in understanding the basis of risk-factor heterogeneity in CAD.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Microbiota , Bacteria/genetics , Coronary Artery Disease/genetics , Coronary Artery Disease/metabolism , Humans , Metabolome , Metabolomics/methods , Microbiota/genetics , Risk Factors
3.
Catheter Cardiovasc Interv ; 99(2): 418-423, 2022 02.
Article in English | MEDLINE | ID: mdl-33491870

ABSTRACT

OBJECTIVES: Assess the impact on fluoroscopy time and contrast use in patients with tortuous brachiocephalic/thoracic aortas undergoing right transradial coronary angiography (RTCA) and provide strategies to manage. BACKGROUND: Unfavorable anatomy with severe brachiocephalic/thoracic tortuosity, referred to as an "elephant head," remains a significant obstacle for RTCA. METHODS: We reviewed the coronary angiograms of patients who underwent RTCA and had tortuous aortas. Angiography was attempted first using a universal catheter (Tiger) and switched to a left coronary specific catheter (Judkins Left [JL]) if challenging. Fluoroscopy time, contrast volume, and greatest distance from the patient's midline to the catheter in the aorta were recorded. RESULTS: Forty-nine patients (62.6 ± 12.0 years, 69.4% male) were included. Fifteen (30.6%) patients underwent successful angiography with a Tiger catheter; 34 (69.4%) patients required switching to JL catheter. The average distance of Tiger catheters to the midline of the spine was 0.78 ± 0.41 cm versus 1.28 ± 0.44 cm (p = .001) in JL catheters. Tiger catheter use resulted in less fluoroscopy time (6.48 ± 4.73 min) and contrast use (58.87 ± 43.53 ml) than in cases switched to JL (13.26 ± 10.76 min [p = .026]; 86.5 ± 69.95 ml [(p = .017]). CONCLUSIONS: For patients undergoing RTCA with significant brachiocephalic/thoracic aorta tortuosity, "elephant head," a Tiger catheter can be used efficiently for curvatures <1 cm from the middle of the spine. We propose that for curvatures >1 cm, operators should consider immediately switching to a JL catheter.


Subject(s)
Elephants , Animals , Aorta, Thoracic/diagnostic imaging , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Coronary Angiography/adverse effects , Coronary Angiography/methods , Female , Fluoroscopy , Humans , Male , Radial Artery/diagnostic imaging , Treatment Outcome
4.
Am J Cardiol ; 160: 106-111, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34607645

ABSTRACT

The occurrence of venous thromboembolisms in patients with COVID-19 has been established. We sought to evaluate the clinical impact of thrombosis in patients with COVID-19 over the span of the pandemic to date. We analyzed patients with COVID-19 with a diagnosis of thrombosis who presented to the MedStar Health system (11 hospitals in Washington, District of Columbia, and Maryland) during the pandemic (March 1, 2020, to March 31, 2021). We compared the clinical course and outcomes based on the presence or absence of thrombosis and then, specifically, the presence of cardiac thrombosis. The cohort included 11,537 patients who were admitted for COVID-19. Of these patients, 1,248 had noncardiac thrombotic events and 1,009 had cardiac thrombosis (myocardial infarction) during their hospital admission. Of the noncardiac thrombotic events, 562 (45.0%) were pulmonary embolisms, 480 (38.5%) were deep venous thromboembolisms, and 347 (27.8%) were strokes. In the thrombosis arm, the mean age of the cohort was 64.5 ± 15.3 years, 53.3% were men, and the majority were African-American (64.9%). Patients with thrombosis tended to be older with more co-morbidities. The in-hospital mortality rate was significantly higher (16.0%) in patients with COVID-19 with concomitant non-cardiac thrombosis than in those without thrombosis (7.9%, p <0.001) but lower than in patients with COVID-19 with cardiac thrombosis (24.7%, p <0.001). In conclusion, patients with COVID-19 with thrombosis, especially cardiac thrombosis, are at higher risk for in-hospital mortality. However, this prognosis is not as grim as for patients with COVID-19 and cardiac thrombosis. Efforts should be focused on early recognition, evaluation, and intensifying antithrombotic management for these patients.


Subject(s)
COVID-19/physiopathology , Coronary Thrombosis/physiopathology , Hospital Mortality , Myocardial Infarction/physiopathology , Pulmonary Embolism/physiopathology , Stroke/physiopathology , Venous Thrombosis/physiopathology , Aged , Aged, 80 and over , COVID-19/complications , Coronary Thrombosis/complications , Female , Humans , Male , Middle Aged , Myocardial Infarction/complications , Pulmonary Embolism/complications , SARS-CoV-2 , Stroke/complications , Venous Thrombosis/complications
5.
Am J Cardiol ; 157: 42-47, 2021 10 15.
Article in English | MEDLINE | ID: mdl-34384590

ABSTRACT

Cardiac involvement in coronavirus disease 2019 (COVID-19) has been established. This is manifested by troponin elevation and associated with worse patient prognosis. We evaluated whether patient outcomes improved as experience accumulated during the pandemic. We analyzed COVID-19-positive patients with myocardial injury (defined as troponin elevation) who presented to the MedStar Health system (11 hospitals in Washington, DC, and Maryland) during the "Early Phase" of the pandemic (March 1 - June 30, 2020) and compared their characteristics and outcomes to the COVID-19-positive patients with the presence of troponin elevation in the "Later Phase" of the pandemic (October 1, 2020 - January 31, 2021). The cohort included 788 COVID-19-positive admitted patients for whom troponin was elevated, 167 during the "Early Phase" and 621 during the "Later Phase." Maximum troponin-I in the "Early Phase" was 13.46±34.72 ng/mL versus 11.21±20.57 ng/mL in the "Later Phase" (p = 0.553). In-hospital mortality was significantly higher in the "Later Phase" (50.3% vs. 24.6%; p<0.001), as were incidence of intensive-care-unit admission (77.8% vs. 46.1%; p<0.001) and need for mechanical ventilation (61.7% versus 28%; p<0.001). In addition, more "Early Phase" patients underwent coronary angiography (6% vs. 2.3%; p=0.013). Finally, 3% of "Early Phase" and 0.8% of "Later Phase" patients underwent percutaneous coronary intervention (p=0.025). In conclusion, treatment outcomes have significantly improved since the beginning of the pandemic in COVID-19-positive patients with troponin elevation. This may be attributed to awareness, severity of the disease, improvements in therapies, and provider experience.


Subject(s)
COVID-19/epidemiology , Myocardial Infarction/therapy , Troponin I/blood , Aged , Aged, 80 and over , Clinical Competence , Cohort Studies , Coronary Angiography/statistics & numerical data , District of Columbia/epidemiology , Female , Hospital Mortality , Humans , Intensive Care Units , Male , Maryland/epidemiology , Middle Aged , Myocardial Infarction/epidemiology , Pandemics , Patient Admission/statistics & numerical data , Percutaneous Coronary Intervention/statistics & numerical data , Respiration, Artificial/statistics & numerical data
6.
Cardiovasc Revasc Med ; 33: 62-67, 2021 12.
Article in English | MEDLINE | ID: mdl-34247983

ABSTRACT

Despite contemporary advances in stent technology, in-stent restenosis (ISR) remains a common issue following percutaneous coronary intervention. A novel classification system based on the underlying mechanism of action of restenosis was recently introduced. The Waksman In-Stent Restenosis Classification characterizes different patterns of ISR to best delineate the type of restenosis and help guide treatment. Intravascular imaging with either intravascular ultrasound or optical coherence tomography allows for real-time evaluation of ISR. We herein provide an illustrative review of the Waksman In-Stent Restenosis Classification.


Subject(s)
Coronary Restenosis , Drug-Eluting Stents , Percutaneous Coronary Intervention , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Coronary Vessels , Humans , Percutaneous Coronary Intervention/adverse effects , Stents , Treatment Outcome
7.
Am J Cardiol ; 152: 132-137, 2021 08 01.
Article in English | MEDLINE | ID: mdl-34103158

ABSTRACT

End-stage liver disease (ESLD) is increasingly prevalent and shares many risk factors with coronary artery disease (CAD). No specific guidelines exist for pre-liver transplant evaluation of CAD, and pretransplant cardiovascular testing varies widely. The aim of this study is to characterize pre-transplant cardiac testing practices with post-transplant clinical outcomes. We retrospectively reviewed patients undergoing initial liver transplantation at our transplant center between January 2015 and March 2019. Patients with previous liver transplantation or multi-organ transplantation were excluded. Electronic medical records were reviewed for relevant demographic and clinical data. We included 285 patients with a mean follow-up of 2.4 years. Of 274 patients (96.1%) with pre-transplant transthoracic echocardiogram (TTE), 18 (6.6%) were abnormal. Non-invasive ischemic testing was performed in 193 (68%) patients: 165 (58%) underwent stress TTE, 24 (8%) underwent myocardial perfusion imaging, 3 underwent coronary computed tomography, and 1 underwent exercise electrocardiogram. Sixteen patients (6%) had left heart catheterization of which 10 (63%) were abnormal and 5 proceeded to revascularization before transplant. There were 4 (1.4%) deaths within 30 days of transplant and 23 deaths (8.1%) in total. ST-elevation myocardial infarction was seen in 1 patient within 30 days and 1 patient after 30 days (0.7% total). No cardiovascular deaths were observed. Among patients undergoing liver transplantation, pre-transplantation cardiovascular testing is exceedingly common and post-transplant cardiovascular complications are rare. Additional research is needed to determine the optimal testing and surveillance in this patient population.


Subject(s)
Coronary Angiography/statistics & numerical data , Echocardiography/statistics & numerical data , End Stage Liver Disease/surgery , Exercise Test/statistics & numerical data , Liver Transplantation/methods , Myocardial Infarction/epidemiology , Postoperative Complications/epidemiology , Preoperative Care/statistics & numerical data , Adult , Aged , Cardiac Catheterization , Cardiovascular Diseases/mortality , Computed Tomography Angiography , Female , Humans , Male , Middle Aged , Mortality , Myocardial Perfusion Imaging/statistics & numerical data , Myocardial Revascularization/statistics & numerical data , Non-ST Elevated Myocardial Infarction/epidemiology , Retrospective Studies , ST Elevation Myocardial Infarction/epidemiology
8.
Cardiovasc Revasc Med ; 33: 45-48, 2021 12.
Article in English | MEDLINE | ID: mdl-34088598

ABSTRACT

BACKGROUND: Cardiac involvement in coronavirus disease 2019 (COVID-19) is known, manifested by troponin elevation, and these patients have a worse prognosis than patients without myocardial injury. METHODS: We analyzed COVID-19-positive patients who presented to the MedStar Health system (11 hospitals in Washington, DC, and Maryland) during the pandemic (March 1-September 30, 2020). We compared renal function and subsequent in-hospital clinical outcomes based on the presence or absence of troponin elevation. The primary outcome was the incidence of acute kidney injury in COVID-19 patients with troponin elevation. We also evaluated in-hospital mortality, overall and based on the presence and absence of both troponin elevation and renal dysfunction. RESULTS: The cohort included 3386 COVID-19-positive admitted patients for whom troponin was drawn. Of these patients, 195 had troponin elevation (defined as ≥1.0 ng/mL), mean age was 61 ± 16 years, and 51% were men. In-hospital mortality was significantly higher (53.8%) in COVID-19-positive patients with concomitant troponin elevation than in those without troponin elevation (14.5%; p < 0.001). COVID-19-positive patients with troponin elevation had a higher prevalence of renal dysfunction (58.5%) than those without troponin elevation (23.4%; p < 0.001). Further analysis demonstrated that having both troponin elevation and renal dysfunction carried the worst in-hospital prognosis (in-hospital mortality 57.9%; intensive-care-unit admission 76.8%; ventilation requirement 63.2%), as compared to the absence or presence of either. CONCLUSION: COVID-19 patients with troponin elevation are at higher risk for worsening renal function, and these patients subsequently have worse in-hospital clinical outcomes. Efforts should focus on early recognition, evaluation, and intensifying care of these patients.


Subject(s)
COVID-19 , Kidney Diseases/virology , Troponin/blood , Aged , COVID-19/complications , COVID-19/mortality , Female , Hospital Mortality , Humans , Male , Middle Aged , Pandemics , Retrospective Studies
9.
Cardiovasc Revasc Med ; 33: 7-12, 2021 12.
Article in English | MEDLINE | ID: mdl-34078581

ABSTRACT

BACKGROUND: Prospective bicuspid low-risk transcatheter aortic valve replacement (TAVR) registries' data demonstrated encouraging short-term results. Detailed data on transcatheter heart valve (THV) geometry after deployment using contemporary devices are lacking. This study sought to examine valve geometry after TAVR in patients with bicuspid aortic stenosis (AS). METHODS: The study population was patients from the LRT (Low Risk TAVR) trial who underwent TAVR using the SAPIEN 3 THV for bicuspid and tricuspid AS. THV geometry measured on 30-day computed tomography (CT) included valve height, angle, depth, and eccentricity. Additionally, THV hemodynamics and outcomes post-TAVR were compared among patients with bicuspid and tricuspid AS. RESULTS: A total of 107 patients from the LRT trial using the SAPIEN 3 THV were included in our analysis. On 30-day CT, the valve height ratio (1.07 vs. 1.07; p = 0.348), depths (right [5.6 mm vs. 6.2 mm; p = 0.223], left [5.3 mm vs. 4.4 mm; p = 0.082] and non [4.8 mm vs. 4.5 mm; p = 0.589] coronary cusps), eccentricities (1.08 vs. 1.07; p = 0.9550), and angles (except the right [3.9 degrees vs. 6.3 degrees; p = 0.003] and left [3.6 degrees vs. 6.0 degrees; p = 0.007]) were similar between bicuspid and tricuspid patients. Hemodynamics, stroke, and mortality were similar at 1 year. CONCLUSION: Despite challenging bicuspid anatomy of the aortic valve, our comprehensive CT analysis supports similar THV geometry between patients with bicuspid and tricuspid AS undergoing TAVR using the SAPIEN 3 THV in low-risk patients. This translated to excellent short-term clinical outcomes and THV hemodynamics in both aortic valve morphologies. TRIAL REGISTRY: NCT02628899, https://clinicaltrials.gov/ct2/show/NCT02628899.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prospective Studies , Prosthesis Design , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
11.
Am Heart J ; 238: 59-65, 2021 08.
Article in English | MEDLINE | ID: mdl-33961829

ABSTRACT

BACKGROUND: To date, there are no real-world studies comparing cangrelor to glycoprotein IIb/IIIa inhibitors (GPI) during percutaneous coronary intervention (PCI). Thus, we performed this study to evaluate the safety and effectiveness of cangrelor compared to GPI during PCI. METHODS: We identified patients who underwent PCI at our institution who received either cangrelor or GPI during PCI. Patients already on GPI or cangrelor prior to PCI or who received both cangrelor and GPI were excluded. Baseline demographics and clinical outcomes were extracted. Major bleeding is defined as a composite of major hematoma >4 cm, hematocrit drop >15, and gastrointestinal bleeding. RESULTS: A total of 2072 patients received adjunctive antiplatelet therapy during PCI (cangrelor [n=478]; GPI [n=1594]). Patients' mean age was 61±12 years. Most (66%) presented with acute coronary syndrome. Patients who received cangrelor were older and had a higher percentage of acute coronary syndrome and lower baseline hematocrit in comparison with patients who received GPI. Procedural success was achieved in 94% of patients, with no difference between groups. Major bleeding events (1.7% vs. 5.1%, P=.001), any vascular complication rates, and hospital length of stay were significantly lower in the cangrelor group. In-hospital ischemic events did not differ between groups. On regression analysis, patients on cangrelor were noted to have significantly lower major bleeding events (OR 0.23; 95% CI, 0.09-0.59). CONCLUSIONS: Balancing ischemic and bleeding risks with adjunctive antiplatelet drugs is of prime importance during PCI. Our real-world analysis shows that cangrelor is safe and effective when compared to GPI during PCI.


Subject(s)
Adenosine Monophosphate/analogs & derivatives , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors/therapeutic use , Platelet Glycoprotein GPIIb-IIIa Complex/antagonists & inhibitors , Purinergic P2Y Receptor Antagonists/therapeutic use , Acute Coronary Syndrome/blood , Adenosine Monophosphate/adverse effects , Adenosine Monophosphate/therapeutic use , Female , Gastrointestinal Hemorrhage/chemically induced , Hematocrit , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Humans , Length of Stay , Male , Middle Aged , Platelet Aggregation Inhibitors/adverse effects , Purinergic P2Y Receptor Antagonists/adverse effects , Retrospective Studies , ST Elevation Myocardial Infarction/epidemiology
12.
Am J Cardiol ; 151: 45-50, 2021 07 15.
Article in English | MEDLINE | ID: mdl-34030883

ABSTRACT

The prognosis of left circumflex (LC) versus non-LC in-stent restenosis (ISR) ostial lesions following treatment has not been assessed. We aimed to assess this prognosis. Anecdotally, treatment of ostial LC ISR has been associated with high recurrence rates. We performed a retrospective analysis of patients from our institution who underwent coronary intervention of an ostial ISR lesion between 2003 and 2018. The primary endpoint was target lesion revascularization (TLR) and major adverse cardiovascular events (MACE). Overall, 563 patients underwent ostial ISR lesion intervention, 144 for an ostial LC ISR lesion. Compared to patients with ostial ISR in non-LC lesions, patients with ostial LC ISR were older, had higher rates of diabetes mellitus and previous coronary bypass surgery. At 1-year follow-up, TLR-MACE rates were 26.6% in the LC group versus 18.4% in the non-LC group (p = 0.036). The TLR rate was also higher in the LC group compared to the non-LC group (p = 0.0498). Univariate and multivariate analyses demonstrated a higher TLR-MACE rate for LC versus non-LC ostial ISR lesions. In conclusion, our study shows increased event rates after treatment of LC versus non-LC ISR lesions. Further studies should be done to assess the optimal treatment approach for ostial LC ISR.


Subject(s)
Angioplasty, Balloon, Coronary , Brachytherapy , Coronary Artery Disease/surgery , Coronary Restenosis/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention , Postoperative Complications/therapy , Aged , Atherectomy, Coronary , Female , Hemorrhage/epidemiology , Hospital Mortality , Humans , Male , Metals , Myocardial Infarction/epidemiology , Postoperative Complications/epidemiology , Proportional Hazards Models , Recurrence , Stents , Stroke/epidemiology , Treatment Outcome , Ultrasonography, Interventional
16.
Catheter Cardiovasc Interv ; 98(3): 572-577, 2021 09.
Article in English | MEDLINE | ID: mdl-33539651

ABSTRACT

OBJECTIVES: We analyzed post-marketing surveillance data from the United States Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database for suture-based vascular closure devices (VCDs) - Perclose ProGlide (Abbott, Chicago, Illinois) and Prostar XL (Abbott). BACKGROUND: Suture-based VCDs are mostly used for large-bore femoral arterial access-site closure. Real-world, contemporary experience on the most commonly reported complications and modes of failure associated with these devices is limited. METHODS: Post-marketing surveillance data from the FDA MAUDE database, for the ProGlide system and for the Prostar XL system, were analyzed, yielding 827 Perclose ProGlide reports and 175 Prostar XL reports. RESULTS: Of the 827 reports of major complications involving the Perclose ProGlide devices, 404 reports involved injury, and one involved death related to the device. In the Prostar XL analysis, 94 reports involved injury, and one involved death. Bleeding from vessel injury was the most common adverse outcome described with both devices, followed by hematoma and thrombus. Surgical repair was the most commonly used treatment strategy. In terms of device malfunction, suture-related malfunction (212 reports) was most commonly seen in the Perclose ProGlide group, while failed deployment was most commonly seen in the Prostar XL group. CONCLUSIONS: Our analysis of the MAUDE database demonstrates that in real-world practice, suture-based VCDs were found to be associated with complications, including vascular injury, difficulties with the device itself, and even death. Ongoing user education and pre-procedural patient selection are important to minimize risks associated with suture-based vascular closure devices.


Subject(s)
Vascular Closure Devices , Femoral Artery/surgery , Humans , Sutures , Treatment Outcome , United States , United States Food and Drug Administration
17.
Cardiovasc Revasc Med ; 27: 63-66, 2021 06.
Article in English | MEDLINE | ID: mdl-33402323

ABSTRACT

BACKGROUND/PURPOSE: The MANTA vascular closure device (VCD) is the first commercially available dedicated closure device for large-bore femoral arterial access-site closure and was approved by the United States Food and Drug Administration (FDA) in February 2019. Real-world data on the most commonly reported complications and modes of failure associated with the MANTA closure device are limited. We analyzed post-marketing surveillance data from FDA's Manufacturer and User Facility Device Experience (MAUDE) database for the MANTA VCD (Teleflex, Wayne, Pennsylvania). METHODS/MATERIALS: Post-marketing surveillance data from the FDA MAUDE database from February 2019 through March 2020 were analyzed, yielding 170 reports. RESULTS: Of the 170 reports of major complications involving MANTA devices, 141 reports involved either injury (136) or death (5) related to the device. Of the 141 reports, bleeding was the most common adverse outcome described (45), followed by vessel occlusion (30) and vessel dissection (21). Device malfunction incidents (29 reports) were reported in 4 main categories: failed deployment (16 reports), malposition of the collagen (9), insufficient information (3), and device dislocation (1). CONCLUSIONS: Our analysis of the MAUDE database demonstrates that in real-world practice, the MANTA VCD was found to be associated with complications, including death, vascular injury, and difficulties with the device itself. Ongoing user education, proctoring, and pre-procedural patient selection are important to minimize risks associated with the MANTA VCD.


Subject(s)
Vascular Closure Devices , Databases, Factual , Femoral Artery , Hemorrhage/etiology , Humans , Treatment Outcome , United States , United States Food and Drug Administration
18.
Cardiovasc Revasc Med ; 27: 90-94, 2021 06.
Article in English | MEDLINE | ID: mdl-33414080

ABSTRACT

BACKGROUND/PURPOSE: We present three recent cases at our institution that demonstrate early, aggressive in-stent restenosis (ISR) of double-kissing (DK) crush technique despite careful adherence to the technique and compliance of the patient. There are multiple percutaneous coronary intervention strategies for left main (LM) coronary artery bifurcation disease. The DK crush technique has gained popularity for the treatment of complex bifurcation lesions, including distal LM bifurcations. METHODS/MATERIALS: We reviewed clinical and procedural characteristics of three recent patients who presented at our tertiary center with non-ST-elevation myocardial infarction (NSTEMI) in the setting of early, aggressive ISR of DK crush. All patients underwent imaging-guided DK crush stenting with full adherence to all steps of the technique. RESULTS: The median age was 65 years, median follow-up was 8 months from initial DK crush, and all three patients presented with NSTEMI. Patients had significant ISR in both limbs of the bifurcation involving aggressive tissue proliferation. These patients were treated differently: intracoronary brachytherapy, direct stenting, and coronary artery bypass grafting. CONCLUSIONS: DK crush for unprotected LM distal bifurcation can result in aggressive ISR with tissue proliferation and target vessel failure despite adhering to all steps of the technique. More research is warranted before DK crush is adopted as the default technique for bifurcation lesions.


Subject(s)
Coronary Artery Disease , Coronary Restenosis , Drug-Eluting Stents , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Humans , Prospective Studies , Stents , Treatment Outcome
19.
Cardiovasc Revasc Med ; 27: 57-62, 2021 06.
Article in English | MEDLINE | ID: mdl-33071196

ABSTRACT

BACKGROUND/PURPOSE: Coronary artery calcification is a marker of advanced atherosclerosis and a predictor of adverse clinical outcomes. Rotational atherectomy (RA) can effectively modify calcified lesions, optimizing procedural outcomes. We interrogated the most commonly reported adverse events involving rotational atherectomy systems (Rotablator and Rotapro) by analyzing post-marketing surveillance data from the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database. METHODS/MATERIALS: We queried MAUDE from September 1, 2016, through December 31, 2019. After excluding duplicate reports, we included 363 reports for Rotablator and 63 reports for Rotapro in the final analysis. RESULTS: Percentages represent the proportion of total submitted MAUDE reports. The most commonly reported complications for Rotablator and Rotapro included dissection (2.7% and 6.3%, respectively) and perforation (4.1% and 19%, respectively). The most commonly reported device-related issues included detachment or structural damage, or both, for Rotablator (39.1%) and entrapment of the device component for Rotapro (47.6%). The most commonly damaged device component was the Rotawire, whereas the most commonly entrapped device component was the Rotaburr for both device configurations. Rotablator and Rotapro device-related complications were most commonly reported for the left anterior descending artery. CONCLUSION: An analysis of the MAUDE database demonstrates that in real-world practice, RA devices are associated with important complications. Ongoing surveillance of safety profiles, patient outcomes, and failure modes of RA devices is warranted. Our analysis provides important insights into the mechanisms of failure of RA devices and associated complications but cannot verify causality.


Subject(s)
Atherectomy, Coronary , Coronary Artery Disease , Atherectomy, Coronary/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Databases, Factual , Humans , Risk Factors , Treatment Outcome , United States , United States Food and Drug Administration
SELECTION OF CITATIONS
SEARCH DETAIL
...