ABSTRACT

BACKGROUND: There is conflicting evidence regarding the safety and efficacy of transcatheter aortic valve implantation (TAVI) procedures in patients with severe aortic stenosis and low left ventricular ejection fraction (EF). The primary aim of this study was to determine the impact of TAVI on short- and long-term mortality in patients with low EF (EF <50%); the secondary aim was to analyze the impact of TAVI procedure on EF recovery in the same setting of patients. METHODS AND RESULTS: Twenty-six studies enrolling 6898 patients with severe aortic stenosis undergoing TAVI procedure were included in the meta-analysis and analyzed for 30-day, 6-month and 1-year all-cause and cardiovascular mortality; a further meta-analysis was also performed in patients with low EF to assess EF changes post TAVI. In low EF patients, both all-cause and cardiovascular short- and long-term mortality were significantly higher when compared to patients with normal EF (30-day-all-cause mortality: 0.13; 95% confidence interval [CI]: 0.01 to 0.25, I(2)=49.65, Q=21.85; 1-year-all-cause mortality: 0.25; 95% [CI]: 0.16 to 0.34, I(2)=25.57, Q=16.12; 30-day-cardiovascular mortality: 0.03; 95% [CI]: -0.31 to 0.36, I(2)=66.84, Q=6.03; 1-year-cardiovascular mortality: 0.29; 95% [CI]: 0.12 to 0.45, I(2)=0.00, Q=1.88). Nevertheless, in low EF patients TAVI was associated with a significant recovery of EF, which started at discharge and proceeded up to 1-year-follow-up. CONCLUSIONS: Patients with low EF severe aortic stenosis have higher mortality following TAVI compared to normal EF patients, despite a significant and sustained improvement in EF.


Subject(s)
Aortic Valve Stenosis/mortality , Severity of Illness Index , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/etiology , Clinical Trials as Topic/mortality , Humans , Mortality/trends
2.
Clin Physiol Funct Imaging ; 33(2): 117-21, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23383689

ABSTRACT

PURPOSE: Worldwide left ventricular (LV) twist is measured by 2D speckle tracking acquiring apical short axis at a LV level where papillary muscles are no longer visible; however, we hypothesized that this methodological recommendation is not enough accurate to obtain a reliable measurement of apical rotation. METHODS: We measured twist and untwist rate in 30 healthy subjects by following the earlier method. By 3D echocardiography, we identified two LV apex levels: (i) 3D Apex, defined as the last apical slice at which LV cavity was visible; (ii) 2D Apex, defined as the level where diameters are equal to those of apical LV short axis used for twist analysis in the same subject. The ratio between the distance of 2D Apex and 3D Apex from LV base was calculated and expressed as percentage (2D Apex/3D Apex). RESULTS: 2D Apex/3D Apex was strongly related to the magnitude of twist and untwisting rate (r = 0·82, P<0·001; r = -0·46, P = 0·015, respectively). The only determinant of twist was 2D Apex/3D Apex (r(2)  = 0·68; r = 0·82; F ratio: 52·6, P<0·001); whereas untwisting rate was influenced by 2D Apex/3D Apex and age (r(2)  = 0·42; r = 0·65; F ratio: 7·7; P = 0·003 for 2D Apex/3D Apex; and P = 0·011 for age). CONCLUSIONS: Left ventricular apical level acquisition, even when recorded in a standard manner, determines variability of twist mechanics measurements. Thus, current anatomical markers used to identify LV apex for twist analysis are not reliable and need different standardization. 3D echocardiography may help in such standardization.


Subject(s)
Echocardiography, Doppler/methods , Heart Ventricles/diagnostic imaging , Myocardial Contraction , Ventricular Function, Left , Adult , Biomechanical Phenomena , Echocardiography, Doppler/standards , Female , Humans , Linear Models , Male , Middle Aged , Predictive Value of Tests , Reference Values , Reproducibility of Results , Torsion, Mechanical , Young Adult
3.
Echocardiography ; 27(6): 608-12, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20412271

ABSTRACT

BACKGROUND: Aortic valve sclerosis (AVS) is a marker of cardiovascular risk; its prevalence increases in elderly and in patients with hypertension and/or coronary arterial disease (CAD). There are no data available in patients with peripheral arterial disease (PAD) and with both CAD and PAD. METHODS: To investigate the presence of AVS, 57 patients with stable CAD, 38 with PAD, and 62 with CAD + PAD where studied by echocardiography. RESULTS: The prevalence of AVS progressively increased within groups (P = 0.005). The prevalence of AVS in PAD doubled that in CAD group (42.1% vs. 22.8%, P < 0.05). PAD patients had a 4.634 (95% CI: 1.02-17.88; P = 0.026) fold increased risk of AVS compared to CAD. Also CAD + PAD group had a higher prevalence of aortic sclerosis when compared to CAD group (50.8% vs. 22.8%, P = 0.001). CAD + PAD showed a 3.799 (95% CI: 1.26-11.45; P < 0 .01) fold greater risk of aortic sclerosis than CAD group. There were no differences in AVS prevalence between CAD + PAD and PAD group (50.8% vs. 42.1%; P = 0.36). Age was related to AVS in both analysis (PAD vs. CAD and CAD + PAD vs. CAD: OR = 1.09, 95% CI: 1.02-1.16, P = 0.011 and OR = 1.13, 95% CI: 1.07-1.21; P < 0.001) but no classical cardiovascular risk factors. CONCLUSIONS: PAD patients have an elevated prevalence of AVS greater than CAD patients. In patients with both disease, the prevalence of AVS is similar to that of patients with PAD alone.


Subject(s)
Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Echocardiography/statistics & numerical data , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/epidemiology , Aged , Comorbidity , Female , Humans , Incidence , Italy/epidemiology , Male , Middle Aged , Sclerosis
4.
Eur J Echocardiogr ; 10(5): 716-7, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19454553

ABSTRACT

We present a case of a mechanical mitral valve thrombosis in a 37-year-old woman occurred 2 days after a Caesarean delivery. The patient stopped warfarin and initiated low-molecular-weight heparin 1 week before the programmed delivery. Subsequently the diagnosis of thrombosis, heparin infusion was started however unsuccessfully and eventually patient was referred for cardiac surgery.


Subject(s)
Cesarean Section , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/etiology , Echocardiography, Transesophageal , Heart Valve Prosthesis/adverse effects , Adult , Anticoagulants/administration & dosage , Electrocardiography , Female , Humans