Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Pers Med ; 13(7)2023 Jun 28.
Article in English | MEDLINE | ID: mdl-37511675

ABSTRACT

Arterial blood gas analysis (ABGA) is one of the few tests performed during cardiopulmonary resuscitation (CPR). There have been some studies on the prediction of survival outcomes in adult out-of-hospital cardiac arrest (OHCA) patients during CPR using ABGA results. However, in pediatric OHCA patients, the prognosis of survival outcome based on ABGA results during CPR remains unclear. We retrospectively analyzed prospectively collected data from the Korean Cardiac Arrest Resuscitation Consortium (KoCARC) registry, a multicenter OHCA registry of Republic of Korea. We analyzed 108 pediatric (age < 19 years) OHCA patients between October 2015 and June 2022. Using multivariable logistic regression, an adjusted odds ratio (aOR) was obtained to validate the ABGA results of survival to hospital admission and survival to discharge. The variables associated with survival to hospital admission were non-comorbidities (aOR 3.03, 95% confidence interval (CI) 1.22-7.53, p = 0.017) and PaO2 > 45.750 mmHg (aOR 2.69, 95% CI 1.13-6.42, p = 0.026). There was no variable that was statistically significant association with survival to discharge. PaO2 > 47.750 mmHg and non-comorbidities may serve as an independent prognostic factor for survival to hospital admission in pediatric OHCA patients. However, the number of cases analyzed in our study was relatively small, and there have been few studies investigating the association between ABGA results during CPR and the survival outcome of pediatric OHCA patients. Therefore, further large-scale studies are needed.

2.
J Pers Med ; 13(6)2023 Jun 19.
Article in English | MEDLINE | ID: mdl-37374006

ABSTRACT

Aerosols and droplets have put healthcare workers performing airway management at high risk of contracting coronavirus disease 2019 (COVID-19). Experts have developed endotracheal intubation (ETI) guidelines and protocols to protect intubators from infection. We aimed to determine whether changes in the emergency department (ED) intubation protocol to prevent COVID-19 infection were associated with first-pass success (FPS) rates in ETI. We used data from the airway management registries in two academic EDs. The study was divided into pre-pandemic (January 2018 to January 2020) and pandemic (February 2020 to February 2022) periods. We selected 2476 intubation cases, including 1151 and 1325 cases recorded before and during the pandemic, respectively. During the pandemic, the FPS rate was 92.2%, which did not change significantly, and major complications increased slightly but not significantly compared with the pre-pandemic period. The OR for the FPS of applying infection prevention intubation protocols was 0.72 (p = 0.069) in a subgroup analysis, junior emergency physicians (PGY1 residents) had an FPS of less than 80% regardless of pandemic protocol implementation. The FPS rate of senior emergency physicians in physiologically difficult airways decreased significantly during the pandemic (98.0% to 88.5%). In conclusion, the FPS rate and complications for adult ETI performed by emergency physicians using COVID-19 infection prevention intubation protocols were similar to pre-pandemic conditions.

3.
Medicina (Kaunas) ; 58(9)2022 Sep 06.
Article in English | MEDLINE | ID: mdl-36143910

ABSTRACT

Background and objectives: The optic nerve sheath diameter (ONSD) is indicative of elevated intracranial pressure. However, the usefulness of the ONSD for predicting neurologic outcomes in cardiac arrest survivals has been debatable. Reportedly, the ONSD/eyeball transverse diameter (ETD) ratio is a more reliable marker for identifying intracranial pressure than sole use of ONSD. Materials and Methods: This retrospective study aimed to investigate the prognostic value of the ONSD/ETD ratio in out-of-hospital cardiac arrest (OHCA) patients. We studied the brain computed tomography scans of adult OHCA patients with return of spontaneous circulation, who visited a single hospital connected with a Korean university between January 2015 and September 2020. We collected baseline characteristics and patient information from electronic medical records and ONSD and ETD were measured by two physicians with a pre-defined protocol. According to their neurologic outcome upon hospital discharge, patients were divided into good neurologic outcome (GNO; cerebral performance category [CPC] 1-2) and poor neurologic outcome (PNO; CPC 3-5) groups. We evaluated the ONSD/ETD ratio between the GNO and PNO groups to establish its prognostic value for neurologic outcomes. Results: Of the 100 included patients, 28 had GNO. Both the ONSD and ETD were not significantly different between the two groups (ONSD, 5.48 mm vs. 5.66 mm, p = 0.054; ETD, 22.98 mm vs. 22.61 mm, p = 0.204). However, the ONSD/ETD ratio was significantly higher in the PNO group in the univariate analysis (0.239 vs. 0.255, p = 0.014). The area under the receiver operating characteristic curve of ONSD/ETD ratio for predicting PNO was 0.66 (95% confidence interval, 0.56-0.75; p = 0.006). There was no independent relationship between the ONSD/ETD ratio and PNO in multivariate analysis (aOR = 0.000; p = 0.173). Conclusions: The ONSD/ETD ratio was more reliable than sole use of ONSD and might be used to predict neurologic outcomes in OHCA survivors.


Subject(s)
Out-of-Hospital Cardiac Arrest , Adult , Humans , Intracranial Pressure , Optic Nerve/diagnostic imaging , Out-of-Hospital Cardiac Arrest/complications , Out-of-Hospital Cardiac Arrest/therapy , Prognosis , Retrospective Studies , Ultrasonography
4.
Article in English | MEDLINE | ID: mdl-34207432

ABSTRACT

The optic nerve sheath diameter (ONSD) can help predict the neurologic outcomes of patients with post-cardiac arrest (CA) return of spontaneous circulation (ROSC). We aimed to investigate the effect of ONSD changes before and after CA on neurologic outcomes in patients with ROSC after CA using brain computed tomography (CT). The study included patients hospitalized after CA, who had undergone pre- and post-CA brain CT between January 2001 and September 2020. The patients were divided into good and poor neurologic outcome (GNO and PNO, respectively) groups based on their neurologic outcome at hospital discharge. We performed between-group comparisons of the amount and rate of ONSD changes in brain CT and calculated the area under the curve (AUC) to determine their predictive value for neurologic outcomes. Among the 96 enrolled patients, 25 had GNO. Compared with the GNO group, the PNO group showed a significantly higher amount (0.30 vs. 0.63 mm; p = 0.030) and rate (5.26 vs. 12.29%; p = 0.041) of change. The AUC for predicting PNO was 0.64 (95% confidence interval = 0.53-0.73; p = 0.04), and patients with a rate of ONSD change >27.2% had PNO with 100% specificity and positive predictive value. Hence, ONSD changes may predict neurologic outcomes in patients with post-CA ROSC.


Subject(s)
Heart Arrest , Optic Nerve , Humans , Neuroimaging , Optic Nerve/diagnostic imaging , Predictive Value of Tests , Tomography, X-Ray Computed
5.
Biomed Res Int ; 2015: 961782, 2015.
Article in English | MEDLINE | ID: mdl-26161424

ABSTRACT

OBJECTIVES: Early airway management is very important for severely ill patients. This study aimed to investigate the efficacy of face to face intubation in four different types of laryngoscopes (Macintosh laryngoscope, Pentax airway scope (AWS), Glidescope video laryngoscope (GVL), and C-MAC video laryngoscope (C-MAC)). METHOD: Ninety-five nurses and emergency medical technicians were trained to use the AWS, C-MAC, GVL and Macintosh laryngoscope with standard airway trainer manikin and face to face intubation. We compared VCET (vocal cord exposure time), tube pass time, 1st ventilation time, VCET to tube pass time, tube pass time to 1st ventilation time, and POGO (percentage of glottis opening) score. In addition, we compared success rate according to the number of attempts and complications. RESULT: VCET was similar among all laryngoscopes and POGO score was higher in AWS. AWS and Macintosh blade were faster than GVL and C-MAC in total intubation time. Face to face intubation success rate was lower in GVL than other laryngoscopes. CONCLUSION: AWS and Macintosh were favorable laryngoscopes in face to face intubation. GVL had disadvantage performing face to face intubation.


Subject(s)
Intubation, Intratracheal/methods , Laryngoscopes , Laryngoscopy/methods , Vocal Cords/physiopathology , Adult , Clinical Competence , Female , Health Personnel , Humans , Male , Manikins , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...