Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biosensors (Basel) ; 13(7)2023 Jul 13.
Article in English | MEDLINE | ID: mdl-37504127

ABSTRACT

Biopotential electrodes play an integral role within smart wearables and clothing in capturing vital signals like electrocardiogram (ECG), electromyogram (EMG), and electroencephalogram (EEG). This study focuses on dry e-textile electrodes (E1-E6) and a laser-cut knit electrode (E7), to assess their impedance characteristics under varying contact forces and moisture conditions. Synthetic perspiration was applied using a moisture management tester and impedance was measured before and after exposure, followed by a 24 h controlled drying period. Concurrently, the signal-to-noise ratio (SNR) of the dry electrode was evaluated during ECG data collection on a healthy participant. Our findings revealed that, prior to moisture exposure, the impedance of electrodes E7, E5, and E2 was below 200 ohm, dropping to below 120 ohm post-exposure. Embroidered electrodes E6 and E4 exhibited an over 25% decrease in mean impedance after moisture exposure, indicating the impact of stitch design and moisture on impedance. Following the controlled drying, certain electrodes (E1, E2, E3, and E4) experienced an over 30% increase in mean impedance. Overall, knit electrode E7, and embroidered electrodes E2 and E6, demonstrated superior performance in terms of impedance, moisture retention, and ECG signal quality, revealing promising avenues for future biopotential electrode designs.


Subject(s)
Electrocardiography , Textiles , Humans , Electric Impedance , Electrodes
2.
Ergonomics ; 60(7): 997-1007, 2017 Jul.
Article in English | MEDLINE | ID: mdl-27562913

ABSTRACT

Range of motion (ROM) can be restricted by wearing stiff and bulky clothing. This is particularly true of firefighter suits that are constructed using fabric layers to provide thermal protection from fire. This study developed an evaluation technique to quantify the loss of mobility associated with wearing firefighters' protective suits that were deliberately selected to represent similar ergonomic design features. The ROM of 10 firefighters was measured using electro-goniometers attached to their bodies while they wore uniforms and a reference outfit, and performed specific movements. The most restrictive uniform is the Bulky suit that contained additional layers of materials in sleeves and on the knees. The Traditional Suit was more ROM restrictive than Ergonomic. The subjective evaluation of suits supported the objective assessments provided by the electro-goniometers. A 3-D body scanning technique was employed to establish a correlation between the bulkiness of firefighter outfits and subject ROM. Practitioner Summary: This study presents a methodology for measurements of range of motion (ROM) in firefighters wearing personal protective equipment (PPE). Even small differences in designs of PPE may impact firefighters' ROM, which can be detected by electro-goniometers providing measurements if they are attached along the joint to measure limb angular movement.


Subject(s)
Ergonomics/methods , Firefighters , Movement/physiology , Personal Protective Equipment/adverse effects , Range of Motion, Articular/physiology , Adult , Equipment Design/adverse effects , Humans , Male , Middle Aged , Musculoskeletal Diseases/etiology , North Carolina , Occupational Diseases/etiology
SELECTION OF CITATIONS
SEARCH DETAIL