1.
J Electromyogr Kinesiol ; 76: 102874, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38547715

ABSTRACT

The diversity in electromyography (EMG) techniques and their reporting present significant challenges across multiple disciplines in research and clinical practice, where EMG is commonly used. To address these challenges and augment the reproducibility and interpretation of studies using EMG, the Consensus for Experimental Design in Electromyography (CEDE) project has developed a checklist (CEDE-Check) to assist researchers to thoroughly report their EMG methodologies. Development involved a multi-stage Delphi process with seventeen EMG experts from various disciplines. After two rounds, consensus was achieved. The final CEDE-Check consists of forty items that address four critical areas that demand precise reporting when EMG is employed: the task investigated, electrode placement, recording electrode characteristics, and acquisition and pre-processing of EMG signals. This checklist aims to guide researchers to accurately report and critically appraise EMG studies, thereby promoting a standardised critical evaluation, and greater scientific rigor in research that uses EMG signals. This approach not only aims to facilitate interpretation of study results and comparisons between studies, but it is also expected to contribute to advancing research quality and facilitate clinical and other practical applications of knowledge generated through the use of EMG.


Subject(s)
Checklist , Consensus , Delphi Technique , Electromyography , Research Design , Electromyography/methods , Electromyography/standards , Checklist/standards , Humans , Research Design/standards , Reproducibility of Results
2.
J Electromyogr Kinesiol ; 75: 102864, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38310768

ABSTRACT

Advanced single-use dynamic EMG-torque models require burdensome subject-specific calibration contractions and have historically been assumed to produce lower error than generic models (i.e., models that are identical across subjects and muscles). To investigate this assumption, we studied generic one degree of freedom (DoF) models derived from the ensemble median of subject-specific models, evaluated across subject, DoF and joint. We used elbow (N = 64) and hand-wrist (N = 9) datasets. Subject-specific elbow models performed statistically better [5.79 ± 1.89 %MVT (maximum voluntary torque) error] than generic elbow models (6.21 ± 1.85 %MVT error). However, there were no statistical differences between subject-specific vs. generic models within each hand-wrist DoF. Next, we evaluated generic models across joints. The best hand-wrist generic model had errors of 6.29 ± 1.85 %MVT when applied to the elbow. The elbow generic model had errors of 7.04 ± 2.29 %MVT when applied to the hand-wrist. The generic elbow model was statistically better in both joints, compared to the generic hand-wrist model. Finally, we tested Butterworth filter models (a simpler generic model), finding no statistical differences between optimum Butterworth and subject-specific models. Overall, generic models simplified EMG-torque training without substantive performance degradation and provided the possibility of transfer learning between joints.


Subject(s)
Elbow Joint , Muscle, Skeletal , Humans , Muscle, Skeletal/physiology , Electromyography , Torque , Elbow/physiology , Elbow Joint/physiology , Joints
3.
J Electromyogr Kinesiol ; 72: 102807, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37552918

ABSTRACT

This tutorial intends to provide insight, instructions and "best practices" for those who are novices-including clinicians, engineers and non-engineers-in extracting electromyogram (EMG) amplitude from the bipolar surface EMG (sEMG) signal of voluntary contractions. A brief discussion of sEMG amplitude extraction from high density sEMG (HDsEMG) arrays and feature extraction from electrically elicited contractions is also provided. This tutorial attempts to present its main concepts in a straightforward manner that is accessible to novices in the field not possessing a wide range of technical background (if any) in this area. Surface EMG amplitude, also referred to as the sEMG envelope [often implemented as root mean square (RMS) sEMG or average rectified value (ARV) sEMG], quantifies the voltage variation of the sEMG signal and is grossly related to the overall neural excitation of the muscle and to peripheral parameters. The tutorial briefly reviews the physiological origin of the voluntary sEMG signal and sEMG recording, including electrode configurations, sEMG signal transduction, electronic conditioning and conversion by an analog-to-digital converter. These topics have been covered in greater detail in prior tutorials in this series. In depth descriptions of state-of-the-art methods for computing sEMG amplitude are then provided, including guidance on signal pre-conditioning, absolute value vs. square-law detection, selection of appropriate sEMG amplitude smoothing filters and attenuation of measurement noise. The tutorial provides a detailed list of best practices for sEMG amplitude estimation.


Subject(s)
Muscle, Skeletal , Humans , Electromyography/methods , Muscle, Skeletal/physiology , Electrodes
4.
Sci Rep ; 13(1): 7750, 2023 05 12.
Article in English | MEDLINE | ID: mdl-37173370

ABSTRACT

The advent of mobile devices, wearables and digital healthcare has unleashed a demand for accurate, reliable, and non-interventional ways to measure continuous blood pressure (BP). Many consumer products claim to measure BP with a cuffless device, but their lack of accuracy and reliability limit clinical adoption. Here, we demonstrate how multimodal feature datasets, comprising: (i) pulse arrival time (PAT); (ii) pulse wave morphology (PWM), and (iii) demographic data, can be combined with optimized Machine Learning (ML) algorithms to estimate Systolic BP (SBP), Diastolic BP (DBP) and Mean Arterial Pressure (MAP) within a 5 mmHg bias of the gold standard Intra-Arterial BP, well within the acceptable limits of the IEC/ANSI 80601-2-30 (2018) standard. Furthermore, DBP's calculated using 126 datasets collected from 31 hemodynamically compromised patients had a standard deviation within 8 mmHg, while SBP's and MAP's exceeded these limits. Using ANOVA and Levene's test for error means and standard deviations, we found significant differences in the various ML algorithms but found no significant differences amongst the multimodal feature datasets. Optimized ML algorithms and key multimodal features obtained from larger real-world data (RWD) sets could enable more reliable and accurate estimation of continuous BP in cuffless devices, accelerating wider clinical adoption.


Subject(s)
Blood Pressure Determination , Photoplethysmography , Humans , Blood Pressure/physiology , Reproducibility of Results , Algorithms , Machine Learning , Pulse Wave Analysis
5.
Sensors (Basel) ; 23(8)2023 Apr 13.
Article in English | MEDLINE | ID: mdl-37112294

ABSTRACT

Wearable wireless biomedical sensors have emerged as a rapidly growing research field. For many biomedical signals, multiple sensors distributed about the body without local wired connections are required. However, designing multisite systems at low cost with low latency and high precision time synchronization of acquired data is an unsolved problem. Current solutions use custom wireless protocols or extra hardware for synchronization, forming custom systems with high power consumption that prohibit migration between commercial microcontrollers. We aimed to develop a better solution. We successfully developed a low-latency, Bluetooth low energy (BLE)-based data alignment method, implemented in the BLE application layer, making it transferable between manufacturer devices. The time synchronization method was tested on two commercial BLE platforms by inputting common sinusoidal input signals (over a range of frequencies) to evaluate time alignment performance between two independent peripheral nodes. Our best time synchronization and data alignment method achieved absolute time differences of 69 ± 71 µs for a Texas Instruments (TI) platform and 477 ± 490 µs for a Nordic platform. Their 95th percentile absolute errors were more comparable-under 1.8 ms for each. Our method is transferable between commercial microcontrollers and is sufficient for many biomedical applications.

6.
Article in English | MEDLINE | ID: mdl-36875964

ABSTRACT

Most transradial prosthesis users with conventional "Sequential" myoelectric control have two electrode sites which control one degree of freedom (DoF) at a time. Rapid EMG co-activation toggles control between DoFs (e.g., hand and wrist), providing limited function. We implemented a regression-based EMG control method which achieved simultaneous and proportional control of two DoFs in a virtual task. We automated electrode site selection using a short-duration (90 s) calibration period, without force feedback. Backward stepwise selection located the best electrodes for either six or 12 electrodes (selected from a pool of 16). We additionally studied two, 2-DoF controllers: "Intuitive" control (hand open-close and wrist pronation-supination controlled virtual target size and rotation, respectively) and "Mapping" control (wrist flexion-extension and ulnar-radial deviation controlled virtual target left-right and up-down movement, respectively). In practice, a Mapping controller would be mapped to control prosthesis hand open-close and wrist pronation-supination. Eleven able-bodied subjects and 4 limb-absent subjects completed virtual target matching tasks (fixed target moves to a new location after being "matched," and subject immediately pursues) and fixed (static) target tasks. For all subjects, both 2-DoF controllers with 6 optimally-sited electrodes had statistically better target matching performance than Sequential control in number of matches (average of 4-7 vs. 2 matches, p< 0.001) and throughput (average of 0.75-1.25 vs. 0.4 bits/s, p< 0.001), but not overshoot rate and path efficiency. There were no statistical differences between 6 and 12 optimally-sited electrodes for both 2-DoF controllers. These results support the feasibility of 2-DoF simultaneous, proportional myoelectric control.

7.
Sensors (Basel) ; 23(5)2023 Feb 23.
Article in English | MEDLINE | ID: mdl-36904670

ABSTRACT

Wireless wearable sensor systems for biomedical signal acquisition have developed rapidly in recent years. Multiple sensors are often deployed for monitoring common bioelectric signals, such as EEG (electroencephalogram), ECG (electrocardiogram), and EMG (electromyogram). Compared with ZigBee and low-power Wi-Fi, Bluetooth Low Energy (BLE) can be a more suitable wireless protocol for such systems. However, current time synchronization methods for BLE multi-channel systems, via either BLE beacon transmissions or additional hardware, cannot satisfy the requirements of high throughput with low latency, transferability between commercial devices, and low energy consumption. We developed a time synchronization and simple data alignment (SDA) algorithm, which was implemented in the BLE application layer without the need for additional hardware. We further developed a linear interpolation data alignment (LIDA) algorithm to improve upon SDA. We tested our algorithms using sinusoidal input signals at different frequencies (10 to 210 Hz in increments of 20 Hz-frequencies spanning much of the relevant range of EEG, ECG, and EMG signals) on Texas Instruments (TI) CC26XX family devices, with two peripheral nodes communicating with one central node. The analysis was performed offline. The lowest average (±standard deviation) absolute time alignment error between the two peripheral nodes achieved by the SDA algorithm was 384.3 ± 386.5 µs, while that of the LIDA algorithm was 189.9 ± 204.7 µs. For all sinusoidal frequencies tested, the performance of LIDA was always statistically better than that of SDA. These average alignment errors were quite low-well below one sample period for commonly acquired bioelectric signals.


Subject(s)
Biosensing Techniques , Wearable Electronic Devices , Wireless Technology , Algorithms
8.
J Electromyogr Kinesiol ; 69: 102753, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36731399

ABSTRACT

Bilateral movement is widely used for calibration of myoelectric prosthesis controllers, and is also relevant as rehabilitation therapy for patients with motor impairment and for athletic training. Target tracking and/or force matching tasks can be used to elicit such bilateral movement. Limited descriptive accuracy data exist in able-bodied subjects for bilateral target tracking or dominant vs non-dominant dynamic force matching tasks requiring more than one degree of freedom (DoF). We examined dynamic trajectory (0.75 Hz band-limited, white, uniform random) constant-posture, hand open-close, wrist pronation-supination target tracking and matching tasks. Tasks were normalized to maximum voluntary contraction (MVC), spanning a ± 30% MVC force range, in four 1-DoF and 2-DoF tasks: (1, 2) unilateral dominant limb tracking with/without visual feedback, and (3, 4) bilateral dominant/non-dominant limb tracking with mirror visual feedback. In 12 able-bodied subjects, unilateral tracking error with visual feedback averaged 10-15 %MVC, but up to 30 %MVC without visual feedback. Bilateral matching error averaged âˆ¼10 %MVC and was affected little by visual feedback type, so long as feedback was provided. In 1-DoF bilateral tracking, the dominant side had statistically lower error than the non-dominant side. In 2-DoF bilateral tracking, the side providing mirror visual feedback exhibited lower error than the opposite side. In 2-DoF tasks (assumed to be more challenging than their constituent 1-DoF tracking tasks), hand grip force errors grew disproportionately larger than those of each wrist DoF. In unilateral 1-DoF tasks, both hand vs target and wrist vs target latency averaged 250-350 ms. In unilateral 2-DoF tasks, wrist vs target latency also averaged 250-350 ms, while hand vs target latency averaged > 500 ms. These results provide guidance on bilateral 2-DoF hand-wrist performance in target tracking, and dominant vs non-dominant force matching tasks.


Subject(s)
Hand Strength , Wrist , Humans , Wrist/physiology , Hand Strength/physiology , Muscle, Skeletal/physiology , Upper Extremity , Hand/physiology
9.
J Electromyogr Kinesiol ; 68: 102726, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36571885

ABSTRACT

The analysis of single motor unit (SMU) activity provides the foundation from which information about the neural strategies underlying the control of muscle force can be identified, due to the one-to-one association between the action potentials generated by an alpha motor neuron and those received by the innervated muscle fibers. Such a powerful assessment has been conventionally performed with invasive electrodes (i.e., intramuscular electromyography (EMG)), however, recent advances in signal processing techniques have enabled the identification of single motor unit (SMU) activity in high-density surface electromyography (HDsEMG) recordings. This matrix, developed by the Consensus for Experimental Design in Electromyography (CEDE) project, provides recommendations for the recording and analysis of SMU activity with both invasive (needle and fine-wire EMG) and non-invasive (HDsEMG) SMU identification methods, summarizing their advantages and disadvantages when used during different testing conditions. Recommendations for the analysis and reporting of discharge rate and peripheral (i.e., muscle fiber conduction velocity) SMU properties are also provided. The results of the Delphi process to reach consensus are contained in an appendix. This matrix is intended to help researchers to collect, report, and interpret SMU data in the context of both research and clinical applications.


Subject(s)
Muscle, Skeletal , Research Design , Humans , Electromyography/methods , Muscle, Skeletal/physiology , Consensus , Motor Neurons/physiology , Action Potentials/physiology
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2864-2869, 2022 07.
Article in English | MEDLINE | ID: mdl-36085874

ABSTRACT

Neurological trauma, such as stroke, traumatic brain injury (TBI), spinal cord injury, and cerebral palsy can cause mild to severe upper limb impairments. Hand impairment makes it difficult for individuals to complete activities of daily living, especially bimanual tasks. A robotic hand orthosis or hand exoskeleton can be used to restore partial function of an intact but impaired hand. It is common for upper extremity prostheses and orthoses to use electromyography (EMG) sensing as a method for the user to control their device. However some individuals with an intact but impaired hand may struggle to use a myoelectrically controlled device due to potentially confounding muscle activity. This study was conducted to evaluate the application of conventional EMG control techniques as a robotic orthosis/exoskeleton user input method for individuals with mild to severe hand impairments. Nine impaired subjects and ten healthy subjects were asked to perform repeated contractions of muscles in their forearm and then onset analysis and feature classification were used to determine the accuracy of the employed EMG techniques. The average accuracy for contraction identification across employed EMG techniques was 95.4% ± 4.9 for the healthy subjects and 73.9% ± 13.1 for the impaired subjects with a range of 47.0% ± 19.1 - 91.6% ± 8.5. These preliminary results suggest that the conventional EMG control technologies employed in this paper may be difficult for some impaired individuals to use due to their unreliable muscle control.


Subject(s)
Activities of Daily Living , Self-Help Devices , Electromyography , Hand , Humans , Upper Extremity
11.
Article in English | MEDLINE | ID: mdl-35895640

ABSTRACT

Estimating the finger forces from surface electromyography (sEMG) is essential for diverse applications (e.g., human-machine interfacing). The performance of pre-trained sEMG-force models degenerates significantly when applied on a second day, due to the large cross-day variation of sEMG characteristics. Previous studies mainly employed transfer learning algorithms to tackle this problem. However, transfer learning algorithms normally require data collected on the second day for model calibration, increasing the inconvenience in practical use. In this work, we investigated the effect of model regularization on this issue. Specifically, 256-channel high-density sEMG (HDsEMG) signals with varying finger forces were collected on different days (3-25 days apart). We applied randomly generated channel perturbations ("masks") to feature maps of randomly selected channels in training dataset. The channel masks of the training set were generated randomly and independently in each narrow time window (~20 ms). We assumed that by learning from randomly masked feature maps (randomness is the central aspect), the model would not be biased by a small number of features but would be based on learning from a global perspective, therefore avoiding overfitting to the within-day EMG patterns. Moore-Penrose inverse model regularization was also employed as a baseline method, with results showing that cross-day EMG-force models require a higher tolerance parameter compared with within-day applications. In combination with the Moore-Penrose inverse model regularization, further applying random channel masks to the training set significantly improved model performance in cross-day validation.


Subject(s)
Algorithms , Fingers , Electromyography/methods , Humans , Least-Squares Analysis
12.
Article in English | MEDLINE | ID: mdl-35349446

ABSTRACT

Recent research has advanced two degree-of-freedom (DoF), simultaneous, independent and proportional control of hand-wrist prostheses using surface electromyogram signals from remnant muscles as the control input. We evaluated two such regression-based controllers, along with conventional, sequential two-site control with co-contraction mode switching (SeqCon), in box-block, refined-clothespin and door-knob tasks, on 10 able-bodied and 4 limb-absent subjects. Subjects operated a commercial hand and wrist using a socket bypass harness. One 2-DoF controller (DirCon) related the intuitive hand actions of open-close and pronation-supination to the associated prosthesis hand-wrist actions, respectively. The other (MapCon) mapped myoelectrically more distinct, but less intuitive, actions of wrist flexion-extension and ulnar-radial deviation. Each 2-DoF controller was calibrated from separate 90 s calibration contractions. SeqCon performed better statistically than MapCon in the predominantly 1-DoF box-block task (>20 blocks/minute vs. 8-18 blocks/minute, on average). In this task, SeqCon likely benefited from an ability to easily focus on 1-DoF and not inadvertently trigger co-contraction for mode switching. The remaining two tasks require 2-DoFs, and both 2-DoF controllers each performed better (factor of 2-4) than SeqCon. We also compared the use of 12 vs. 6 optimally-selected EMG electrodes as inputs, finding no statistical difference. Overall, we provide further evidence of the benefits of regression-based EMG prosthesis control of 2-DoFs in the hand-wrist.


Subject(s)
Artificial Limbs , Wrist , Electromyography , Hand/physiology , Humans , Muscle, Skeletal/physiology , Wrist/physiology , Wrist Joint/physiology
13.
J Electromyogr Kinesiol ; 64: 102656, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35344841

ABSTRACT

High-density surface electromyography (HDsEMG) can be used to measure the spatial distribution of electrical muscle activity over the skin. As this distribution is associated with the generation and propagation of muscle fiber action potentials, HDsEMG is processed to extract information on regional muscle activation, muscle fiber characteristics and behaviour of individual motor units. This matrix, developed by the Consensus for Experimental Design in Electromyography (CEDE) project, summarizes recommendations on the use of HDsEMG in experimental studies. For each application, recommendations are included regarding electrode montage, electrode type and configuration, electrode location and orientation, data analysis, and interpretation. Cautions and reporting standards are also included. The steps of the Delphi process to reach consensus are contained in an appendix. This matrix is intended to help researchers when collecting, reporting, and interpreting HDsEMG data. It is hoped that this document will be used to generate new empirical evidence to improve how HDsEMG is used in research and in clinical applications.


Subject(s)
Muscle, Skeletal , Research Design , Consensus , Electrodes , Electromyography , Humans , Muscle, Skeletal/physiology
14.
Sensors (Basel) ; 21(15)2021 Jul 30.
Article in English | MEDLINE | ID: mdl-34372403

ABSTRACT

To facilitate the broader use of EMG signal whitening, we studied four whitening procedures of various complexities, as well as the roles of sampling rate and noise correction. We separately analyzed force-varying and constant-force contractions from 64 subjects who completed constant-posture tasks about the elbow over a range of forces from 0% to 50% maximum voluntary contraction (MVC). From the constant-force tasks, we found that noise correction via the root difference of squares (RDS) method consistently reduced EMG recording noise, often by a factor of 5-10. All other primary results were from the force-varying contractions. Sampling at 4096 Hz provided small and statistically significant improvements over sampling at 2048 Hz (~3%), which, in turn, provided small improvements over sampling at 1024 Hz (~4%). In comparing equivalent processing variants at a sampling rate of 4096 Hz, whitening filters calibrated to the EMG spectrum of each subject generally performed best (4.74% MVC EMG-force error), followed by one universal whitening filter for all subjects (4.83% MVC error), followed by a high-pass filter whitening method (4.89% MVC error) and then a first difference whitening filter (4.91% MVC error)-but none of these statistically differed. Each did significantly improve from EMG-force error without whitening (5.55% MVC). The first difference is an excellent whitening option over this range of contraction forces since no calibration or algorithm decisions are required.


Subject(s)
Elbow Joint , Elbow , Algorithms , Electromyography , Humans , Isometric Contraction , Muscle Contraction , Muscle, Skeletal , Posture
15.
J Electromyogr Kinesiol ; 59: 102565, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34102383

ABSTRACT

Consensus on the definition of common terms in electromyography (EMG) research promotes consistency in the EMG literature and facilitates the integration of research across the field. This paper presents a matrix developed within the Consensus for Experimental Design in Electromyography (CEDE) project, providing definitions for terms used in the EMG literature. The definitions for physiological and technical terms that are common in EMG research are included in two tables, with key information on each definition provided in a comment section. A brief outline of some basic principles for recording and analyzing EMG is included in an appendix, to provide researchers new to EMG with background and context for understanding the definitions of physiological and technical terms. This terminology matrix can be used as a reference to aid researchers new to EMG in reviewing the EMG literature.


Subject(s)
Muscle, Skeletal , Research Design , Consensus , Electromyography , Humans
16.
Article in English | MEDLINE | ID: mdl-34018935

ABSTRACT

We provide an open access dataset of High densitY Surface Electromyogram (HD-sEMG) Recordings (named "Hyser"), a toolbox for neural interface research, and benchmark results for pattern recognition and EMG-force applications. Data from 20 subjects were acquired twice per subject on different days following the same experimental paradigm. We acquired 256-channel HD-sEMG from forearm muscles during dexterous finger manipulations. This Hyser dataset contains five sub-datasets as: (1) pattern recognition (PR) dataset acquired during 34 commonly used hand gestures, (2) maximal voluntary muscle contraction (MVC) dataset while subjects contracted each individual finger, (3) one-degree of freedom (DoF) dataset acquired during force-varying contraction of each individual finger, (4) N-DoF dataset acquired during prescribed contractions of combinations of multiple fingers, and (5) random task dataset acquired during random contraction of combinations of fingers without any prescribed force trajectory. Dataset 1 can be used for gesture recognition studies. Datasets 2-5 also recorded individual finger forces, thus can be used for studies on proportional control of neuroprostheses. Our toolbox can be used to: (1) analyze each of the five datasets using standard benchmark methods and (2) decompose HD-sEMG signals into motor unit action potentials via independent component analysis. We expect our dataset, toolbox and benchmark analyses can provide a unique platform to promote a wide range of neural interface research and collaboration among neural rehabilitation engineers.


Subject(s)
Access to Information , Benchmarking , Electromyography , Fingers , Forearm , Humans , Muscle, Skeletal
17.
IEEE J Biomed Health Inform ; 25(4): 1070-1079, 2021 04.
Article in English | MEDLINE | ID: mdl-32991293

ABSTRACT

With the soaring development of body sensor network (BSN)-based health informatics, information security in such medical devices has attracted increasing attention in recent years. Employing the biosignals acquired directly by the BSN as biometrics for personal identification is an effective approach. Noncancelability and cross-application invariance are two natural flaws of most traditional biometric modalities. Once the biometric template is exposed, it is compromised forever. Even worse, because the same biometrics may be employed as tokens for different accounts in multiple applications, the exposed template can be used to compromise other accounts. In this work, we propose a cancelable and cross-application discrepant biometric approach based on high-density surface electromyogram (HD-sEMG) for personal identification. We enrolled two accounts for each user. HD-sEMG signals from the right dorsal hand under isometric contractions of different finger muscles were employed as biometric tokens. Since isometric contraction, in contrast to dynamic contraction, requires no actual movement, the users' choice to login to different accounts is greatly protected against impostors. We realized a promising identification accuracy of 85.8% for 44 identities (22 subjects × 2 accounts) with training and testing data acquired 9 days apart. The high identification accuracy of different accounts for the same user demonstrates the promising cancelability and cross-application discrepancy of the proposed HD-sEMG-based biometrics. To the best of our knowledge, this is the first study to employ HD-sEMG in personal identification applications, with signal variation across days considered.


Subject(s)
Biometry , Fingers , Electromyography , Humans , Movement
18.
IEEE J Biomed Health Inform ; 25(3): 647-655, 2021 03.
Article in English | MEDLINE | ID: mdl-32750937

ABSTRACT

The ability to expertly control different fingers contributes to hand dexterity during object manipulation in daily life activities. The macroscopic spatial patterns of muscle activations during finger movements using global surface electromyography (sEMG) have been widely researched. However, the spatial activation patterns of microscopic motor units (MUs) under different finger movements have not been well investigated. The present work aims to quantify MU spatial activation patterns during movement of distinct fingers (index, middle, ring and little finger). Specifically, we focused on extensor muscles during extension contractions. Motor unit action potentials (MUAPs) during movement of each finger were obtained through decomposition of high-density sEMG (HD-sEMG). First, we quantified the spatial activation patterns of MUs for each finger based on 2-dimension (2-D) root-mean-square (RMS) maps of MUAP grids after spike-triggered averaging. We found that these activation patterns under different finger movements are distinct along the distal-proximal direction, but with partial overlap. Second, to further evaluate MU separability, we classified the spatial activation pattern of each individual MU under distinct finger movement and associated each MU with its corresponding finger with Regularized Uncorrelated Multilinear Discriminant Analysis (RUMLDA). A high accuracy of MU-finger classification tested on 12 subjects with a mean of 88.98% was achieved. The quantification of MU spatial activation patterns could be beneficial to studies of neural mechanisms of the hand. To the best of our knowledge, this is the first work which manages to quantify MU behaviors under different finger movements.


Subject(s)
Fingers , Muscle, Skeletal , Electrodes , Electromyography , Humans , Movement
19.
IEEE Trans Neural Syst Rehabil Eng ; 28(12): 3040-3050, 2020 12.
Article in English | MEDLINE | ID: mdl-33196443

ABSTRACT

System identification models relating forearm electromyogram (EMG) signals to phantom wrist radial-ulnar deviation force, pronation-supination moment and/or hand open-close force (EMG-force) are hampered by lack of supervised force/moment output signals in limb-absent subjects. In 12 able-bodied and 7 unilateral transradial limb-absent subjects, we studied three alternative supervised output sources in one degree of freedom (DoF) and 2-DoF target tracking tasks: (1) bilateral tracking with force feedback from the contralateral side (non-dominant for able-bodied/ sound for limb-absent subjects) with the contralateral force as the output, (2) bilateral tracking with force feedback from the contralateral side with the target as the output, and (3) dominant/limb-absent side unilateral target tracking without feedback and the target used as the output. "Best-case" EMG-force errors averaged ~ 10% of maximum voluntary contraction (MVC) when able-bodied subjects' dominant limb produced unilateral force/moment with feedback. When either bilateral tracking source was used as the model output, statistically larger errors of 12-16 %MVC resulted. The no-feedback alternative produced errors of 25-30 %MVC, which was nearly half the tested force range of ± 30 %MVC. Therefore, the no-feedback model output was not acceptable. We found little performance variation between DoFs. Many subjects struggled to perform 2-DoF target tracking.


Subject(s)
Wrist Joint , Wrist , Electromyography , Forearm , Hand , Humans , Muscle, Skeletal
20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 369-373, 2020 07.
Article in English | MEDLINE | ID: mdl-33018005

ABSTRACT

Single-use EMG-force models (i.e., a new model is trained each time the electrodes are donned) are used in various areas, including ergonomics assessment, clinical biomechanics, and motor control research. For one degree of freedom (1-DoF) tasks, input-output (black box) models are common. Recently, black box models have expanded to 2-DoF tasks. To facilitate efficient training, we examined parameters of black box model training methods in 2-DoF force-varying, constant-posture tasks consisting of hand open-close combined with one wrist DoF. We found that approximately 40-60 s of training data is best, with progressively higher EMG-force errors occurring for progressively shorter training durations. Surprisingly, 2-DoF models in which the dynamics were universal across all subjects (only channel gain was trained to each subject) generally performed 15-21% better than models in which the complete dynamics were trained to each subject. In summary, lower error EMG-force models can be formed through diligent attention to optimization of these factors.


Subject(s)
Hand , Wrist , Electromyography , Posture , Wrist Joint