Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Circ Genom Precis Med ; 17(1): e004285, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38059363

ABSTRACT

BACKGROUND: Few clinical data are available on NEXN mutation carriers, and the gene's involvement in cardiomyopathies or sudden death has not been fully established. Our objectives were to assess the prevalence of putative pathogenic variants in NEXN and to describe the phenotype and prognosis of patients carrying the variants. METHODS: DNA samples from consecutive patients with cardiomyopathy or sudden cardiac death/sudden infant death syndrome/idiopathic ventricular fibrillation were sequenced with a custom panel of genes. Index cases carrying at least one putative pathogenic variant in the NEXN gene were selected. RESULTS: Of the 9516 index patients sequenced, 31 were carriers of a putative pathogenic variant in NEXN only, including 2 with double variants and 29 with a single variant. Of the 29 unrelated probands with a single variant (16 males; median age at diagnosis, 32.0 [26.0-49.0] years), 21 presented with dilated cardiomyopathy (prevalence, 0.33%), and 3 presented with hypertrophic cardiomyopathy (prevalence, 0.14%). Three patients had idiopathic ventricular fibrillation, and there were 2 cases of sudden infant death syndrome (prevalence, 0.46%). For patients with dilated cardiomyopathy, the median left ventricle ejection fraction was 37.5% (26.25-50.0) at diagnosis and improved with treatment in 13 (61.9%). Over a median follow-up period of 6.0 years, we recorded 3 severe arrhythmic events and 2 severe hemodynamic events. CONCLUSIONS: Putative pathogenic NEXN variants were mainly associated with dilated cardiomyopathy; in these individuals, the prognosis appeared to be relatively good. However, severe and early onset phenotypes were also observed-especially in patients with double NEXN variants. We also detected NEXN variants in patients with hypertrophic cardiomyopathy and sudden infant death syndrome/idiopathic ventricular fibrillation, although a causal link could not be established.


Subject(s)
Cardiomyopathies , Cardiomyopathy, Dilated , Cardiomyopathy, Hypertrophic , Sudden Infant Death , Ventricular Fibrillation , Male , Infant , Humans , Adult , Middle Aged , Cardiomyopathy, Dilated/genetics , Prevalence , Cardiomyopathies/diagnosis , Phenotype , Cardiomyopathy, Hypertrophic/genetics , Cardiomyopathy, Hypertrophic/complications , Death, Sudden, Cardiac/etiology , Prognosis , Microfilament Proteins/genetics
2.
Heart Rhythm ; 21(3): 313-320, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37956775

ABSTRACT

BACKGROUND: The efficacy of beta-blocker treatment in type 3 long QT syndrome (LQT3) remains debated. OBJECTIVES: The purpose of this study was to test the hypothesis that beta-blocker use is associated with cardiac events (CEs) in a French cohort of LQT3 patients. METHODS: All patients with a likely pathogenic/pathogenic variant in the SCN5A gene (linked to LQT3) were included and followed-up. Documented ventricular tachycardia/ventricular fibrillation, torsades de pointes, aborted cardiac arrest, sudden death, and appropriate shocks were considered as severe cardiac events (SCEs). CEs also included syncope. RESULTS: We included 147 patients from 54 families carrying 23 variants. Six of the patients developed symptoms before the age of 1 year and were analyzed separately. The 141 remaining patients (52.5% male; median age at diagnosis 24.0 years) were followed-up for a median of 11 years. The probabilities of a CE and an SCE from birth to the age of 40 were 20.5% and 9.9%, respectively. QTc prolongation (hazard ratio [HR] 1.12 [1.0-1.2]; P = .005]) and proband status (HR 4.07 [1.9-8.9]; P <.001) were independently associated with the occurrence of CEs. Proband status (HR 8.13 [1.7-38.8]; P = .009) was found to be independently associated with SCEs, whereas QTc prolongation (HR 1.11 [1.0-1.3]; P = .108) did not reach statistical significance. The cumulative probability of the age at first CE/SCE was not lower in patients treated with a beta-blocker. CONCLUSION: In agreement with the literature, proband status and lengthened QTc were associated with a higher risk of CEs. Our data do not show a protective effect of beta-blocker treatment.


Subject(s)
Heart Arrest , Long QT Syndrome , Humans , Male , Young Adult , Adult , Female , Electrocardiography , Long QT Syndrome/drug therapy , Long QT Syndrome/genetics , Long QT Syndrome/diagnosis , Syncope , Heart Arrest/complications , Adrenergic beta-Antagonists/therapeutic use
3.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Article in English | MEDLINE | ID: mdl-37558371

ABSTRACT

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Subject(s)
Defibrillators, Implantable , Heart Defects, Congenital , Transposition of Great Vessels , Humans , Female , Young Adult , Adult , Middle Aged , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Cohort Studies , Treatment Outcome , Retrospective Studies , Heart Defects, Congenital/complications , Heart Defects, Congenital/therapy
4.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37470443

ABSTRACT

AIMS: Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF. METHODS AND RESULTS: This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days-3 months), and non-early PsAF (>3-12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation. Sinus rhythm (SR) and AF voltage maps were created with the Advisor HD Grid™ Mapping Catheter, Sensor Enabled™ for each subject, and the presence of low-voltage area (LVA) (low-voltage cutoffs: 0.1-1.5 mV) was investigated. Follow-up visits were at 3, 6, and 12 months, with a 24-h Holter monitor at 12 months. A Cox proportional hazards model identified associations between mapping data and 12-month recurrence after a single PVI procedure. The study enrolled 300 subjects (113 PAF, 86 early PsAF, and 101 non-early PsAF) at 18 centres. At 12 months, 75.5% of subjects were free from AF/atrial flutter (AFL)/atrial tachycardia (AT) recurrence. Univariate analysis found that arrhythmia recurrence did not correlate with AF diagnosis, but LVA was significantly correlated. Low-voltage area (<0.5 mV) >28% of the left atrium in SR [hazard ratio (HR): 4.82, 95% confidence interval (CI): 2.08-11.18; P = 0.0003] and >72% in AF (HR: 5.66, 95% CI: 2.34-13.69; P = 0.0001) was associated with a higher risk of AF/AFL/AT recurrence at 12 months. CONCLUSION: Larger extension of LVA was associated with an increased risk of arrhythmia recurrence. These subjects may benefit from substrate modification beyond PVI.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Heart Rate , Treatment Outcome , Electrophysiologic Techniques, Cardiac , Recurrence , Time Factors , Heart Atria , Atrial Flutter/diagnosis , Atrial Flutter/surgery , Atrial Flutter/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods
5.
J Am Heart Assoc ; 12(6): e025368, 2023 03 21.
Article in English | MEDLINE | ID: mdl-36926933

ABSTRACT

Background Cardiac adrenergic receptor gene polymorphisms have the potential to influence risk of developing ventricular fibrillation (VF) during ST-segment-elevation myocardial infarction, but no previous study has comprehensively investigated those most likely to alter norepinephrine release, signal transduction, or biased signaling. Methods and Results In a case-control study, we recruited 953 patients with ST-segment-elevation myocardial infarction without previous cardiac history, 477 with primary VF, and 476 controls without VF, and genotyped them for ADRB1 Arg389Gly and Ser49Gly, ADRB2 Gln27Glu and Gly16Arg, and ADRA2C Ins322-325Del. Within each minor allele-containing genotype, haplotype, or 2-genotype combination, patients with incident VF were compared with non-VF controls by odds ratios (OR) of variant frequencies referenced against major allele homozygotes. Of 156 investigated genetic constructs, 19 (12.2%) exhibited significantly (P<0.05) reduced association with incident VF, and none was associated with increased VF risk except for ADRB1 Gly389 homozygotes in the subset of patients not receiving ß-blockers. ADRB1 Gly49 carriers (prevalence 23.0%) had an OR (95% CI) of 0.70 (0.49-0.98), and the ADRA2C 322-325 deletion (Del) carriers (prevalence 13.5%) had an OR of 0.61 (0.39-0.94). When present in genotype combinations (8 each), both ADRB1 Gly49 carriers (OR, 0.67 [0.56-0.80]) and ADRA2C Del carriers (OR, 0.57 [0.45- 0.71]) were associated with reduced VF risk. Conclusions In ST-segment-elevation myocardial infarction, the adrenergic receptor minor alleles ADRB1 Gly49, whose encoded receptor undergoes enhanced agonist-mediated internalization and ß-arrestin interactions leading to cardioprotective biased signaling, and ADRA2C Del322-325, whose receptor causes disinhibition of norepinephrine release, are associated with a lower incidence of VF. Registration URL: https://clinicaltrials.gov; Unique identifier: NCT00859300.


Subject(s)
ST Elevation Myocardial Infarction , Ventricular Fibrillation , Humans , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/genetics , Case-Control Studies , Polymorphism, Genetic , Receptors, Adrenergic/genetics , Norepinephrine
6.
Heart Rhythm ; 20(2): 252-260, 2023 02.
Article in English | MEDLINE | ID: mdl-36309156

ABSTRACT

BACKGROUND: In repaired tetralogy of Fallot (TOF), little is known about characteristics of patients with rapid ventricular tachycardia (VT). Also, whether patients with a first episode of nonrapid VT may subsequently develop rapid VT or ventricular fibrillation (VF) has not been addressed. OBJECTIVES: The objectives of this study were to compare patients with rapid VT/VF with those with nonrapid VT and to assess the evolution of VT cycle lengths (VTCLs) overtime. METHODS: Data were analyzed from a nationwide registry including all patients with TOF and implantable cardioverter-defibrillator (ICD) since 2000. Patients with ≥1 VT episode with VTCL ≤250 ms (240 beats/min) formed the rapid VT/VF group. RESULTS: Of 144 patients (mean age 42.0 ± 12.7 years; 104 [72%] men), 61 (42%) had at least 1 VT/VF episode, including 28 patients with rapid VT/VF (46%), during a median follow-up of 6.3 years (interquartile range 2.2-10.3 years). Compared with patients in the nonrapid VT group, those in the rapid VT/VF group were significantly younger at ICD implantation (35.2 ± 12.6 years vs 41.5 ± 11.2 years; P = .04), had more frequently a history of cardiac arrest (8 [29%] vs 2 [6%]; P = .02), less frequently a history of atrial arrhythmia (11 [42%] vs 22 [69%]; P = .004), and higher right ventricular ejection fraction (43.3% ± 10.3% vs 36.6% ± 11.2%; P = .04). The median VTCL of VT/VF episodes was 325 ms (interquartile range 235-429 ms). None of the patients with a first documented nonrapid VT episode had rapid VT/VF during follow-up. CONCLUSION: Patients with TOF and rapid VT/VF had distinct clinical characteristics. The relatively low variation of VTCL over time suggests a room for catheter ablation without a backup ICD in selected patients with well-tolerated VT.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Tetralogy of Fallot , Male , Humans , Adult , Middle Aged , Female , Stroke Volume , Tetralogy of Fallot/complications , Tetralogy of Fallot/surgery , Follow-Up Studies , Ventricular Function, Right , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Ventricular Fibrillation
7.
JACC Clin Electrophysiol ; 8(10): 1304-1314, 2022 10.
Article in English | MEDLINE | ID: mdl-36266008

ABSTRACT

BACKGROUND: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far. OBJECTIVES: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs). METHODS: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years) were enrolled from 40 centers, including 49 women (29.7%). Among the 9,692 patients with TOF recorded in the national database, the proportion of women with ICDs was estimated to be 1.1% (95% CI: 0.8%-1.5%) vs 2.2% (95% CI: 1.8%-2.6%) in men (P < 0.001). The clinical profiles of patients at implantation, including the number of risk factors for ventricular arrhythmias, were similar between women and men. During a median follow-up period of 6.8 years (IQR: 2.5-11.4 years), 78 patients (47.3%) received at least 1 appropriate ICD therapy, without significant difference in annual incidences between women (12.1%) and men (9.9%) (HR: 1.22; 95% CI: 0.76-1.97; P = 0.40). The risk for overall ICD-related complications was similar in women and men (HR: 1.33; 95% CI: 0.81-2.19; P = 0.30), with 24 women (49.0%) experiencing at least 1 complication. CONCLUSIONS: Our findings suggest that women with TOF at high risk for sudden cardiac death have similar benefit/risk balance from ICD therapy compared with men. Whether ICD therapy is equally offered to at-risk women vs men warrants further evaluation in TOF as well as in other congenital heart disease populations. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Subject(s)
Defibrillators, Implantable , Heart Defects, Congenital , Tetralogy of Fallot , Humans , Female , Male , Adult , Middle Aged , Defibrillators, Implantable/adverse effects , Tetralogy of Fallot/complications , Cohort Studies , Sex Characteristics , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Heart Defects, Congenital/complications
8.
JACC Clin Electrophysiol ; 7(10): 1285-1293, 2021 10.
Article in English | MEDLINE | ID: mdl-33933408

ABSTRACT

OBJECTIVES: This study aimed to assess the impact of pulmonary valve replacement (PVR) on ventricular arrhythmias burden in a population of tetralogy of Fallot (TOF) patients with continuous cardiac monitoring by implantable cardioverter-defibrillators (ICDs). BACKGROUND: Sudden cardiac death is a major cause of death in TOF, and right ventricular overload is commonly considered to be a potential trigger for ventricular arrhythmias. METHODS: Data were analyzed from a nationwide French ongoing study (DAI-T4F) including all TOF patients with an ICD since 2000. Survival data with recurrent events were used to compare the burden of appropriate ICD therapies before and after PVR in patients who underwent PVR over the study period. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years, 70.1% male) were included from 40 centers. Over a median follow-up period of 6.8 (interquartile range: 2.5 to 11.4) years, 26 patients (15.8%) underwent PVR. Among those patients, 18 (69.2%) experienced at least 1 appropriate ICD therapy. When considering all ICD therapies delivered before (n = 62) and after (n = 16) PVR, the burden of appropriate ICD therapies was significantly lower after PVR (HR: 0.21; 95% confidence interval [CI]: 0.08 to 0.56; p = 0.002). Respective appropriate ICD therapies rates per 100 person-years were 44.0 (95% CI: 35.7 to 52.5) before and 13.2 (95% CI: 7.7 to 20.5) after PVR (p < 0.001). In the overall cohort, PVR before ICD implantation was also independently associated with a lower risk of appropriate ICD therapy in primary prevention patients (HR: 0.29 [95% CI: 0.10 to 0.89]; p = 0.031). CONCLUSIONS: In this cohort of high-risk TOF patients implanted with an ICD, the burden of appropriate ICD therapies was significantly reduced after PVR. While optimal indications and timing for PVR are debated, these findings suggest the importance of considering ventricular arrhythmias in the overall decision-making process. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Subject(s)
Cardiac Surgical Procedures , Defibrillators, Implantable , Pulmonary Valve , Tetralogy of Fallot , Adult , Arrhythmias, Cardiac/therapy , Female , Humans , Male , Middle Aged , Pulmonary Valve/surgery , Tetralogy of Fallot/surgery
9.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Article in English | MEDLINE | ID: mdl-32998542

ABSTRACT

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Subject(s)
Defibrillators, Implantable/trends , Tetralogy of Fallot/epidemiology , Tetralogy of Fallot/therapy , Adult , Female , Follow-Up Studies , Humans , Male , Registries
SELECTION OF CITATIONS
SEARCH DETAIL
...