Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 164
Filter
2.
Clin Proteomics ; 21(1): 19, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38429638

ABSTRACT

In persons with dyslipidemia, a high residual risk of cardiovascular disease remains despite lipid lowering therapy. Current cardiovascular risk prediction mainly focuses on low-density lipoprotein cholesterol (LDL-c) levels, neglecting other contributing risk factors. Moreover, the efficacy of LDL-c lowering by statins resulting in reduced cardiovascular risk is only partially effective. Secondly, from a metrological viewpoint LDL-c falls short as a reliable measurand. Both direct and calculated LDL-c tests produce inaccurate test results at the low end under aggressive lipid lowering therapy. As LDL-c tests underperform both clinically and metrologically, there is an urging need for molecularly defined biomarkers. Over the years, apolipoproteins have emerged as promising biomarkers in the context of cardiovascular disease as they are the functional workhorses in lipid metabolism. Among these, apolipoprotein B (ApoB), present on all atherogenic lipoprotein particles, has demonstrated to clinically outperform LDL-c. Other apolipoproteins, such as Apo(a) - the characteristic apolipoprotein of the emerging risk factor lipoprotein(a) -, and ApoC-III - an inhibitor of triglyceride-rich lipoprotein clearance -, have attracted attention as well. To support personalized medicine, we need to move to molecularly defined risk markers, like the apolipoproteins. Molecularly defined diagnosis and molecularly targeted therapy require molecularly measured biomarkers. This review provides a summary of the scientific validity and (patho)physiological role of nine serum apolipoproteins, Apo(a), ApoB, ApoC-I, ApoC-II, ApoC-III, ApoE and its phenotypes, ApoA-I, ApoA-II, and ApoA-IV, in lipid metabolism, their association with cardiovascular disease, and their potential as cardiovascular risk markers when measured in a multiplex apolipoprotein panel.

3.
World Neurosurg ; 184: e503-e510, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38310947

ABSTRACT

BACKGROUND: This was a cross-sectional study on the correlation between abdominal aortic calcification (AAC) and Modic changes (MC). Little is known regarding the etiology of MC in the lumbar spine. Currently, insufficient vascularization of the endplate has been proposed to contribute to the appearance of MC. Our objective was to investigate whether AAC, a marker for a poor vascular status, is associated with MC in patients suffering from degenerative disc disease. METHODS: Radiologic images of patients (n = 130) suffering from degenerative lumbar disc disease were reviewed. Type and severity of MC were assessed using magnetic resonance images, and severity of AAC was evaluated using computed tomography images or fluoroscopy. Both items were dichotomized into minimal and relevant grades. The correlation between them was studied using Spearman's correlation test, with age as a covariate. RESULTS: Of the patients, 113 (87%) demonstrated MC (31% type I, 63% type II, and 6% type III) (55% relevant grade), and 68% had AAC (44% relevant grade). Spearman statistical analysis revealed that AAC was correlated with age (P < 0.001), whereas MC were not (P = 0.142). AAC severity was significantly correlated with MC, remaining so after age adjustment (P < 0.05). While MC type I lacked correlation with AAC, MC type II were significantly correlated with AAC (0.288, P = 0.015); however, this association lost significance after adjusting for age (P = 0.057). CONCLUSIONS: AAC and MC (mainly MC type II) are associated, indicating that reduced blood supply or even a poor systemic vascularization status due to atherosclerotic disease may play a role in the formation of MC. Future studies focusing on the etiology of MC should pay more attention to patients' vascular status and determinants of abdominal aorta calcification.


Subject(s)
Atherosclerosis , Intervertebral Disc Degeneration , Vascular Calcification , Humans , Cross-Sectional Studies , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/pathology , Intervertebral Disc Degeneration/complications , Intervertebral Disc Degeneration/diagnostic imaging , Intervertebral Disc Degeneration/pathology , Lumbosacral Region/pathology , Atherosclerosis/complications , Atherosclerosis/diagnostic imaging , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/pathology , Vascular Calcification/complications , Vascular Calcification/diagnostic imaging
4.
Clin Chem Lab Med ; 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38379410

ABSTRACT

Advances in technology have transformed healthcare and laboratory medicine. Biosensors have emerged as a promising technology in healthcare, providing a way to monitor human physiological parameters in a continuous, real-time, and non-intrusive manner and offering value and benefits in a wide range of applications. This position statement aims to present the current situation around biosensors, their perspectives and importantly the need to set the framework for their validation and safe use. The development of a qualification framework for biosensors should be conceptually adopted and extended to cover digitally measured biomarkers from biosensors for advancing healthcare and achieving more individualized patient management and better patient outcome.

5.
Clin Proteomics ; 21(1): 5, 2024 Jan 24.
Article in English | MEDLINE | ID: mdl-38267848

ABSTRACT

BACKGROUND: The 2022 consensus statement of the European Atherosclerosis Society (EAS) on lipoprotein(a) (Lp(a)) recognizes the role of Lp(a) as a relevant genetically determined risk factor and recommends its measurement at least once in an individual's lifetime. It also strongly urges that Lp(a) test results are expressed as apolipoprotein (a) (apo(a)) amount of substance in molar units and no longer in confounded Lp(a) mass units (mg/dL or mg/L). Therefore, IVD manufacturers should transition to molar units. A prerequisite for this transition is the availability of an Lp(a) Reference Measurement Procedure (RMP) that allows unequivocal molecular detection and quantification of apo(a) in Lp(a). To that end an ISO 17511:2020 compliant LC-MS based and IFCC-endorsed RMP has been established that targets proteotypic peptides of apolipoprotein(a) (apo(a)) in Lp(a). The RMP is laborious and requires highly skilled operators. To guide IVD-manufacturers of immunoassay-based Lp(a) test kits in the transition from mass to molar units, a Designated Comparison Method (DCM) has been developed and evaluated. METHODS: To assess whether the DCM provides equivalent results compared to the RMP, the procedural designs were compared and the analytical performance of DCM and RMP were first evaluated in a head-to-head comparison. Subsequently, apo(a) was quantified in 153 human clinical serum samples. Both DCM and RMP were calibrated using external native calibrators that produce results traceable to SRM2B. Measurement uncertainty (MU) was checked against predefined allowable MU. RESULTS: The major difference in the design of the DCM for apo(a) is the use of only one enzymatic digestion step. The analytical performance of the DCM and RMP for apo(a) is highly similar. In a direct method comparison, equivalent results were obtained with a median regression slope 0.997 of and a median bias of - 0.2 nmol/L (- 0.2%); the intermediate imprecision of the test results was within total allowable error (TEa) (CVa of 10.2% at 90 nmol/L). CONCLUSIONS: The semi-automated, higher throughput, LC-MS-based method for Lp(a) meets the predefined analytical performance specifications and allowable MU and is hence applicable as a higher order Designated Comparison Method, which is ideally suited to guide IVD manufacturers in the transition from Lp(a) mass to molar units.

6.
Clin Microbiol Infect ; 30(2): 216-222, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37805035

ABSTRACT

OBJECTIVES: Urinary tract infection (UTI) is common among older women. However, diagnosis is challenging because of frequent chronic lower urinary tract symptoms, cognitive impairment, and a high prevalence of asymptomatic bacteriuria (ASB). Current urine diagnostics lack specificity, leading to unnecessary treatment and antimicrobial resistance. This study aimed to evaluate the diagnostic accuracy of 12 urine biomarkers for diagnosing UTI in older women. METHODS: In this case-control study, cases were women ≥65 years with ≥2 new-onset lower urinary tract symptoms, pyuria, and one uropathogen ≥104 CFU/mL. Controls were asymptomatic and classified as ASB (one uropathogen ≥105 CFU/mL), negative culture, or mixed flora. Urine biomarker concentrations were measured through liquid chromatography-mass spectrometry and ELISA. Diagnostic accuracy parameters of individual biomarkers and a biomarker model were derived from receiver operating characteristic curves. RESULTS: We included 162 community-dwelling and institutionalized older women. Five urine inflammatory biomarkers demonstrated high discriminative ability (area under the curve ≥0.80): interleukin 6, azurocidin, neutrophil gelatinase-associated lipocalin, tissue inhibitor of metalloproteinases 2, and C-X-C motif chemokine 9. Azurocidin exhibited the highest diagnostic accuracy (sensitivity 86% [95% CI 75%-93%] and specificity 89% [95% CI 82%-94%] at 16.7 ng/mmol creatinine). A combined biomarker and pyuria model showed improved diagnostic accuracy in patients with UTI and ASB, compared with pyuria alone. DISCUSSION: We identified several urine biomarkers that accurately differentiated older women with UTI from asymptomatic women, including ASB. These findings represent a potential advancement towards improved diagnostics for UTI in older women and warrant validation in a diverse population.


Subject(s)
Bacteriuria , Lower Urinary Tract Symptoms , Pyuria , Urinary Tract Infections , Humans , Female , Aged , Male , Pyuria/diagnosis , Case-Control Studies , Urinary Tract Infections/drug therapy , Bacteriuria/drug therapy , Biomarkers
7.
Circulation ; 149(3): 192-203, 2024 01 16.
Article in English | MEDLINE | ID: mdl-37632469

ABSTRACT

BACKGROUND: Lipoprotein(a) is a risk factor for cardiovascular events and modifies the benefit of PCSK9 (proprotein convertase subtilisin/kexin type 9) inhibitors. Lipoprotein(a) concentration can be measured with immunoassays reporting mass or molar concentration or a reference measurement system using mass spectrometry. Whether the relationships between lipoprotein(a) concentrations and cardiovascular events in a high-risk cohort differ across lipoprotein(a) methods is unknown. We compared the prognostic and predictive value of these types of lipoprotein(a) tests for major adverse cardiovascular events (MACE). METHODS: The ODYSSEY OUTCOMES trial (Evaluation of Cardiovascular Outcomes After an Acute Coronary Syndrome During Treatment With Alirocumab) compared the PCSK9 inhibitor alirocumab with placebo in patients with recent acute coronary syndrome. We compared risk of a MACE in the placebo group and MACE risk reduction with alirocumab according to baseline lipoprotein(a) concentration measured by Siemens N-latex nephelometric immunoassay (IA-mass; mg/dL), Roche Tina-Quant turbidimetric immunoassay (IA-molar; nmol/L), and a noncommercial mass spectrometry-based test (MS; nmol/L). Lipoprotein(a) values were transformed into percentiles for comparative modeling. Natural cubic splines estimated continuous relationships between baseline lipoprotein(a) and outcomes in each treatment group. Event rates were also determined across baseline lipoprotein(a) quartiles defined by each assay. RESULTS: Among 11 970 trial participants with results from all 3 tests, baseline median (Q1, Q3) lipoprotein(a) concentrations were 21.8 (6.9, 60.0) mg/dL, 45.0 (13.2, 153.8) nmol/L, and 42.2 (14.3, 143.1) nmol/L for IA-mass, IA-molar, and MS, respectively. The strongest correlation was between IA-molar and MS (r=0.990), with nominally weaker correlations between IA-mass and MS (r=0.967) and IA-mass and IA-molar (r=0.972). Relationships of lipoprotein(a) with MACE risk in the placebo group were nearly identical with each test, with estimated cumulative incidences differing by ≤0.4% across lipoprotein(a) percentiles, and all were incrementally prognostic after accounting for low-density lipoprotein cholesterol levels (all spline P≤0.0003). Predicted alirocumab treatment effects were also nearly identical for each of the 3 tests, with estimated treatment hazard ratios differing by ≤0.07 between tests across percentiles and nominally less relative risk reduction by alirocumab at lower percentiles for all 3 tests. Absolute risk reduction with alirocumab increased with increasing lipoprotein(a) measured by each test, with significant linear trends across quartiles. CONCLUSIONS: In patients with recent acute coronary syndrome, 3 lipoprotein(a) tests were similarly prognostic for MACE in the placebo group and predictive of MACE reductions with alirocumab at the cohort level. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01663402.


Subject(s)
Acute Coronary Syndrome , Anticholesteremic Agents , Hydroxymethylglutaryl-CoA Reductase Inhibitors , Humans , Proprotein Convertase 9 , Cholesterol, LDL , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/drug therapy , Acute Coronary Syndrome/epidemiology , Lipoprotein(a) , Treatment Outcome , Anticholesteremic Agents/therapeutic use , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use
8.
J Thromb Haemost ; 22(4): 1236-1248, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38128762

ABSTRACT

Calibration of prothrombin time (PT) in terms of international normalized ratio (INR) has been outlined in "Guidelines for thromboplastins and plasmas used to control oral anticoagulant therapy" (World Health Organization, 2013). The international standard ISO 17511:2020 presents requirements for manufacturers of in vitro diagnostic (IVD) medical devices (MDs) for documenting the calibration hierarchy for a measured quantity in human samples using a specified IVD MD. The objective of this article is to define an unequivocal, metrologically traceable calibration hierarchy for the INR measured in plasma as well as in whole blood samples. Calibration of PT and INR for IVD MDs according to World Health Organization guidelines is similar to that in cases where there is a reference measurement procedure that defines the measurand for value assignment as described in ISO 17511:2020. We conclude that, for PT/INR standardization, the optimal calibration hierarchy includes a primary process to prepare an international reference reagent and measurement procedure that defines the measurand by a value assignment protocol conforming to clause 5.3 of ISO 17511:2020. A panel of freshly prepared human plasma samples from healthy adult individuals and patients on vitamin K antagonists is used as a commutable secondary calibrator as described in ISO 17511:2020. A sustainable metrologically traceable calibration hierarchy for INR should be based on an international protocol for value assignment with a single primary reference thromboplastin and the harmonized manual tilt tube technique for clotting time determination. The primary international reference thromboplastin reagent should be used only for calibration of successive batches of the secondary reference thromboplastin reagent.


Subject(s)
Chemistry, Clinical , Thromboplastin , Adult , Humans , Prothrombin Time , International Normalized Ratio , Calibration , Anticoagulants/therapeutic use , Reference Standards , Fibrinolytic Agents/therapeutic use , Indicators and Reagents , Communication , Vitamin K
9.
J Am Heart Assoc ; 12(15): e030405, 2023 08.
Article in English | MEDLINE | ID: mdl-37489721

ABSTRACT

Concern continues about whether the measurement of apolipoprotein B (apoB) is adequately standardized, and therefore, whether apoB should be applied widely in clinical care. This concern is misplaced. Our objective is to explain why and what the term "standardization" means. To produce clinically valid results, a test must accurately, precisely, and selectively measure the marker of interest. That is, it must be standardized. Accuracy refers to how closely the result obtained with 1 method corresponds to the result obtained with the standard method, precision to how reproducible the result is on repeated testing, and selectivity to how susceptible the method is to error by inclusion of other classes of lipoprotein particles. Multiple expert groups have determined that the measurement of apoB is adequately standardized for clinical care, and that apoB can be measured inexpensively, using widely available automated methods, more accurately, precisely, and selectively than low-density lipoprotein cholesterol or non-high-density lipoprotein cholesterol. ApoB is a standard superior to low-density lipoprotein cholesterol and high-density lipoprotein cholesterol because it is a defined molecule, whereas the cholesterol markers are the mass of cholesterol within lipoprotein particles defined by their density, not by their molecular structure. Nevertheless, the standardization of apoB is being further improved by the application of mass spectrophotometric methods, whereas the limitations in the standardization and, therefore, the accurate, precise, and selective measurement of low-density lipoprotein cholesterol and high-density lipoprotein cholesterol are unlikely to be overcome. We submit that greater accuracy, precision, and selectivity in measurement is a decisive advantage for apoB in the modern era of intensive lipid-lowering therapies.


Subject(s)
Apolipoproteins B , Cholesterol , Cholesterol, LDL , Apolipoprotein B-100 , Cholesterol, HDL , Lipoproteins , Apolipoprotein A-I
10.
Clin Chem ; 69(8): 924-935, 2023 08 02.
Article in English | MEDLINE | ID: mdl-37477911

ABSTRACT

BACKGROUND: We explored the potential of emerging and conventional urinary kidney injury biomarkers in recipients of living donor (LD) or donation after circulatory death (DCD) kidney transplantation, patients with chronic kidney disease (CKD), and individuals from the general population. METHODS: Urine samples from kidney allograft recipients with mild (LD; n = 199) or severe (DCD; n = 71) ischemia-reperfusion injury (IRI) were analyzed for neutrophil gelatinase-associated lipocalin (NGAL), insulin-like growth factor-binding protein 7 (IGFBP7), tissue inhibitor of metalloproteinases 2 (TIMP2), kidney injury molecule-1 (KIM-1), chemokine C-X-C motif (CXCL9), solute carrier family 22 member 2 (SLC22A2), nephrin, and uromodulin (UMOD) by quantitative multiplex LC-MS/MS analysis. The fold-change in biomarker levels was determined in mild and severe IRI and in patients with CKD stage 1-2 (n = 127) or stage ≥3 (n = 132) in comparison to the general population (n = 1438). Relationships between the biomarkers and total protein, ß2-microglobulin (B2M), creatinine, and osmolality were assessed. RESULTS: NGAL, IGFBP7, TIMP2, KIM-1, CXCL9, and UMOD were quantifiable, whereas nephrin and SLC22A2 were below the limit of detection. Kidney injury biomarkers were increased up to 6.2-fold in allograft recipients with mild IRI and 8.3-fold in recipients with severe IRI, compared to the reference population, with the strongest response observed for NGAL and B2M. In CKD stage 1-2, B2M, NGAL, IGFBP7, TIMP2, KIM-1, UMOD, and CXCL9 were not altered, but in individuals with CKD stage ≥3, B2M, NGAL, and KIM-1 were increased up to 1.3-fold. IGFBP7, TIMP2, NGAL, and CXCL9 were strongly correlated (all r ≥ 0.8); correlations with B2M and TP were smaller (all r ≤ 0.6). CONCLUSIONS: IRI, but not stable CKD, was associated with increased urinary levels of kidney injury biomarkers determined by LC-MS/MS. Absolute and multiplexed protein quantitation by LC-MS/MS is an effective strategy for biomarker panel evaluation for translation toward the clinical laboratory.


Subject(s)
Acute Kidney Injury , Renal Insufficiency, Chronic , Reperfusion Injury , Humans , Lipocalin-2/urine , Chromatography, Liquid , Tandem Mass Spectrometry , Kidney , Biomarkers/urine , Allografts , Acute Kidney Injury/diagnosis
11.
Crit Rev Clin Lab Sci ; 60(7): 483-501, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37128734

ABSTRACT

In the past decade a remarkable rebirth of serum/plasma lipoprotein(a) (Lp(a)) as an independent risk factor of cardiovascular disease (CVD) occurred. Updated evidence for a causal continuous association in different ethnic groups between Lp(a) concentrations and cardiovascular outcomes has been published in the latest European Atherosclerosis Society (EAS) Lp(a) consensus statement. Interest in measuring Lp(a) at least once in a person's lifetime moreover originates from the development of promising new Lp(a) lowering drugs. Accurate and clinically effective Lp(a) tests are of key importance for the timely detection of high-risk individuals and for future evaluation of the therapeutic effects of Lp(a) lowering medication. To this end, it is necessary to improve the performance and standardization of existing Lp(a) tests, as is also noted in the Lp(a) consensus statement. Consequently, a state-of-the-art internationally endorsed reference measurement system (RMS) must be in place that allows for performance evaluation of Lp(a) field tests in order to certify their validity and accuracy. An ELISA-based RMS from Northwest Lipid Research Laboratory (University of Washington, Seattle, USA) has been available since the 1990s. A next-generation apo(a)/Lp(a) RMS is now being developed by a working group from the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). The envisioned apo(a) RMS is based on the direct measurement of selected proteotypic fragments generated after proteolytic digestion using quantitative protein mass spectrometry (MS). The choice for an MS-based RMS enables selective measurement of the proteotypic peptides and is by design apo(a) isoform insensitive. Clearly, the equimolar conversion of apo(a) into the surrogate peptide measurands is required to obtain accurate Lp(a) results. The completeness of proteolysis under reaction conditions from the candidate reference measurement procedure (RMP) has been demonstrated for the quantifying apo(a) peptides. Currently, the candidate apo(a) RMP is endorsed by the IFCC and recommendations for suitable secondary reference materials have been made in a recent commutability study paper. Ongoing efforts toward a complete apo(a) RMS that is listed by the Joint Committee on Traceability in Laboratory Medicine (JCTLM) are focused on the peptide-based calibration and the establishment of a network of calibration laboratories running the apo(a) RMS in a harmonized way. Once completed, it will be the holy grail for evaluation and certification of Lp(a) field methods.

13.
Res Pract Thromb Haemost ; 7(2): 100063, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36923709

ABSTRACT

Background: The STAtins Reduce Thrombophilia trial showed that, in patients with prior venous thrombosis, rosuvastatin decreased various coagulation factor levels. Objectives: Here, we investigated the hypothesis that statins decrease coagulation factor levels through shared mechanisms of synthesis or regulatory pathways with apolipoproteins. Methods: We measured the levels of apolipoprotein (Apo)A-I, A-II, A-IV, (a), B-100, B-total, C-I, C-II, C-III, and E in patients (n = 126) randomized to 28 days of rosuvastatin use. We assessed the association between apolipoproteins and coagulation factors at baseline using linear regression. The mean difference in apolipoprotein levels between baseline and after 28 days of rosuvastatin use was determined through linear regression, adjusting for age, sex, and body mass index. Coagulation factors were added to this model to determine if the lowering of apolipoproteins by rosuvastatin was linked with coagulation factor levels. Results: At baseline, levels of all apolipoproteins, except Apo(a), were positively associated with FVII, FIX, and FXI. Apolipoproteins levels, except for ApoA-I, A-IV, and Apo(a), were decreased after 28 days of rosuvastatin. ApoB-100 showed the largest mean decrease of -0.43 g/L (95% CI = -0.46 to -0.40). The decrease in ApoC-I and C-III levels was associated with a decrease in FVII, whereas the decrease in apoA-II, B-100, and B-total was associated with a decrease in FXI. The decrease in apolipoproteins was neither associated with FVIII or vWF decrease nor with endogenous thrombin potential changes. Conclusions: Rosuvastatin decreases the level of several apolipoproteins, but this decrease was associated only with a decrease in FVII and XI and not with FVIII/vWF.

14.
Res Pract Thromb Haemost ; 7(2): 100079, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36949768

ABSTRACT

Background: Antithrombin deficiency is a rare but severe disorder leading to high risk of thrombosis. The current clinical care pathway relies on activity tests, which only provide overall functional information on the in vitro activity of antithrombin. However, antithrombin exists in many different forms, also known as proteoforms, with varying clinical phenotypes. Precision diagnostics, facilitated by mass spectrometry, provides a strategy to improve patient diagnostics by molecular characterization. Objectives: To develop and analytically validate a mass spectrometry-based test for molecular characterization of antithrombin. Methods: The test was analytically validated based on predefined analytical performance specifications. The validation covered imprecision, carryover, linearity, stability, analytical specificity, a provisional reference interval, and an explorative method comparison. Results: The test passed the predefined analytical performance specifications with a mean within-laboratory imprecision of 5.9%, linearity between 0.08 and 2.58 µmol/L, and a provisional reference interval of 1.07 to 1.49 µmol/L. When measuring samples with a suspected quantitative deficiency, the test showed a good correlation with a commercial activity test (Pearson r = 0.88). Conclusion: The test passed the validation, and we now envision the use of the test for exploration of the clinical relevance of specific antithrombin proteoforms. Puzzling cases of antithrombin deficiency, for instance, due to ambiguous activity results or an atypical clinical presentation, can be investigated by the LC-MRM mass spectrometry test serving as an add-on to the activity test and providing a molecular diagnosis. Clinical studies are planned to investigate the potential of the test to improve antithrombin diagnostics. Furthermore, the molecular information gained using the test may aid in establishing better risk stratification and a basis for personalized medicine.

15.
Clin Infect Dis ; 76(12): 2070-2076, 2023 06 16.
Article in English | MEDLINE | ID: mdl-36806580

ABSTRACT

BACKGROUND: Pre-existing lower urinary tract symptoms (LUTS), cognitive impairment, and the high prevalence of asymptomatic bacteriuria (ASB) complicate the diagnosis of urinary tract infection (UTI) in older women. The presence of pyuria remains the cornerstone of UTI diagnosis. However, >90% of ASB patients have pyuria, prompting unnecessary treatment. We quantified pyuria by automated microscopy and flowcytometry to determine the diagnostic accuracy for UTI and to derive pyuria thresholds for UTI in older women. METHODS: Women ≥65 years with ≥2 new-onset LUTS and 1 uropathogen ≥104 colony-forming units (CFU)/mL were included in the UTI group. Controls were asymptomatic and classified as ASB (1 uropathogen ≥105 CFU/mL), negative culture, or mixed flora. Patients with an indwelling catheter or antimicrobial pretreatment were excluded. Leukocyte medians were compared and sensitivity-specificity pairs were derived from a receiver operating characteristic curve. RESULTS: We included 164 participants. UTI patients had higher median urinary leukocytes compared with control patients (microscopy: 900 vs 26 leukocytes/µL; flowcytometry: 1575 vs 23 leukocytes/µL; P < .001). Area under the curve was 0.93 for both methods. At a cutoff of 264 leukocytes/µL, sensitivity and specificity of microscopy were 88% (positive and negative likelihood ratio: 7.2 and 0.1, respectively). The commonly used cutoff of 10 leukocytes/µL had a poor specificity (36%) and a sensitivity of 100%. CONCLUSIONS: The degree of pyuria can help to distinguish UTI in older women from ASB and asymptomatic controls with pyuria. Current pyuria cutoffs are too low and promote inappropriate UTI diagnosis in older women. Clinical Trials Registration. International Clinical Trials Registry Platform: NL9477 (https://trialsearch.who.int/Trial2.aspx?TrialID=NL9477).


Subject(s)
Bacteriuria , Pyuria , Urinary Tract Infections , Humans , Female , Aged , Pyuria/diagnosis , Pyuria/epidemiology , Pyuria/etiology , Urinary Tract Infections/drug therapy , Bacteriuria/drug therapy , Sensitivity and Specificity , ROC Curve
16.
Clin Chem ; 69(3): 251-261, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36644914

ABSTRACT

BACKGROUND: Medical results generated by European CE Marking for In Vitro Diagnostic or in-house tests should be traceable to higher order reference measurement systems (RMS), such as International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)-endorsed reference measurement procedures (RMPs) and reference materials. Currently, serum apolipoprotein (a) [apo(a)] is recognized as a novel risk factor for cardiovascular risk assessment and patient management. The former RMS for serum apo(a) is no longer available; consequently, an International System of Units (SI)-traceable, ideally multiplexed, and sustainable RMS for apo(a) is needed. METHODS: A mass spectrometry (MS)-based candidate RMP (cRMP) for apo(a) was developed using quantitative bottom-up proteomics targeting 3 proteotypic peptides. The method was provisionally validated according to ISO 15193 using a single human serum based calibrator traceable to the former WHO-IFCC RMS. RESULTS: The quantitation of serum apo(a) was by design independent of its size polymorphism, was linear from 3.8 to 456 nmol/L, and had a lower limit of quantitation for apo(a) of 3.8 nmol/L using peptide LFLEPTQADIALLK. Interpeptide agreement showed Pearson Rs of 0.987 and 0.984 for peptides GISSTVTGR and TPENYPNAGLTR, and method comparison indicated good correspondence (slopes 0.977, 1.033, and 1.085 for LFLEPTQADIALLK, GISSTVTGR, and TPENYPNAGLTR). Average within-laboratory imprecision of the cRMP was 8.9%, 11.9%, and 12.8% for the 3 peptides. CONCLUSIONS: A robust, antibody-independent, MS-based cRMP was developed as higher order RMP and an essential part of the apo(a) traceability chain and future RMS. The cRMP fulfils predefined analytical performance specifications, making it a promising RMP candidate in an SI-traceable MS-based RMS for apo(a).


Subject(s)
Peptides , Serum , Humans , Apoprotein(a) , Mass Spectrometry , Reference Standards , Calibration
17.
Clin Chem ; 69(3): 262-272, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36644921

ABSTRACT

BACKGROUND: Elevated concentrations of lipoprotein(a) [Lp(a)] are directly related to an increased risk of cardiovascular diseases, making it a relevant biomarker for clinical risk assessment. However, the lack of global standardization of current Lp(a) measurement procedures (MPs) leads to inconsistent patient care. The International Federation for Clinical Chemistry and Laboratory Medicine working group on quantitating apolipoproteins by mass spectrometry (MS) aims to develop a next-generation SI (International system of units)-traceable reference measurement system consisting of a MS-based, peptide-calibrated reference measurement procedure (RMP) and secondary serum-based reference materials (RMs) certified for their apolipoprotein(a) [apo(a)] content. To reach measurement standardization through this new measurement system, 2 essential requirements need to be fulfilled: a sufficient correlation among the MPs and appropriate commutability of future serum-based RMs. METHODS: The correlation among the candidate RMP (cRMP) and immunoassay-based MPs was assessed by measuring a panel of 39 clinical samples (CS). In addition, the commutability of 14 different candidate RMs was investigated. RESULTS: Results of the immunoassay-based MPs and the cRMPs demonstrated good linear correlations for the CS but some significant sample-specific differences were also observed. The results of the commutability study show that RMs based on unspiked human serum pools can be commutable with CS, whereas human pools spiked with recombinant apo(a) show different behavior compared to CS. CONCLUSIONS: The results of this study show that unspiked human serum pools are the preferred candidate secondary RMs in the future SI-traceable Lp(a) Reference Measurement System.


Subject(s)
Chemistry, Clinical , Lipoprotein(a) , Humans , Immunoassay , Mass Spectrometry , Reference Standards
18.
J Mass Spectrom Adv Clin Lab ; 27: 49-55, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36619217

ABSTRACT

In the pursuit of personalized diagnostics and tailored treatments, quantitative protein tests contribute to a more precise definition of health and disease. The development of new quantitative protein tests should be driven by an unmet clinical need and performed in a collaborative effort that involves all stakeholders. With regard to the analytical part, mass spectrometry (MS)-based platforms are an excellent tool for quantification of specific proteins in body fluids, for example focused on cancer. The obtained readouts have great potential in determining tumor aggressiveness to facilitate treatment decisions, and can furthermore be used to monitor patient response. Internationally standardized TNM classifications of malignant tumors are beneficial for diagnosis, however treatment outcome and survival of cancer patients is poorly predicted. To this end, the importance of the tumor microenvironment has endorsed the introduction of the tumor-stroma ratio as a prognostic parameter in solid primary tumor types. Currently, the stromal content of tumor tissues is determined via routine diagnostic pathology slides. With the development of liquid chromatography (LC)-MS methods we aim at quantification of tumor-stroma specific proteins in body fluids. In this mini-review the analytical aspect of this developmental trajectory is further detailed.

19.
Clin Chem Lab Med ; 61(4): 608-626, 2023 03 28.
Article in English | MEDLINE | ID: mdl-36716120

ABSTRACT

The EU In-Vitro Diagnostic Device Regulation (IVDR) aims for transparent risk-and purpose-based validation of diagnostic devices, traceability of results to uniquely identified devices, and post-market surveillance. The IVDR regulates design, manufacture and putting into use of devices, but not medical services using these devices. In the absence of suitable commercial devices, the laboratory can resort to laboratory-developed tests (LDT) for in-house use. Documentary obligations (IVDR Art 5.5), the performance and safety specifications of ANNEX I, and development and manufacture under an ISO 15189-equivalent quality system apply. LDTs serve specific clinical needs, often for low volume niche applications, or correspond to the translational phase of new tests and treatments, often extremely relevant for patient care. As some commercial tests may disappear with the IVDR roll-out, many will require urgent LDT replacement. The workload will also depend on which modifications to commercial tests turns them into an LDT, and on how national legislators and competent authorities (CA) will handle new competences and responsibilities. We discuss appropriate interpretation of ISO 15189 to cover IVDR requirements. Selected cases illustrate LDT implementation covering medical needs with commensurate management of risk emanating from intended use and/or design of devices. Unintended collateral damage of the IVDR comprises loss of non-profitable niche applications, increases of costs and wasted resources, and migration of innovative research to more cost-efficient environments. Taking into account local specifics, the legislative framework should reduce the burden on and associated opportunity costs for the health care system, by making diligent use of existing frameworks.


Subject(s)
Clinical Laboratory Services , Reagent Kits, Diagnostic , Humans , Reagent Kits, Diagnostic/standards , European Union , Clinical Laboratory Services/legislation & jurisprudence
20.
Clin Chem Lab Med ; 61(1): 48-54, 2023 01 27.
Article in English | MEDLINE | ID: mdl-36239374

ABSTRACT

BACKGROUND: Standardized results for laboratory tests are particularly important when their interpretation depends on fixed medical practice guidelines or common reference intervals. The medical laboratory community has developed a roadmap for an infrastructure to achieve standardized test results described in the International Organization for Standardization standard 17511:2020 In vitro diagnostic medical devices - Requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples. Among the challenges to implementing metrological traceability are the availability of fit-for-purpose matrix-based certified reference materials (CRMs) and requirements for regulatory review that differ among countries. A workshop in December 2021 focused on these two challenges and developed recommendations for improved practices. DISCUSSION: The participants agreed that prioritization of measurands for standardization should be based on their impact on medical decisions in a clinical pathway. Ensuring that matrix-based CRMs are globally available for more measurands will enable fit-for-purpose calibration hierarchies for more laboratory tests. Regulation of laboratory tests is important to ensure safety and effectiveness for the populations served. Because regulations are country or region specific, manufacturers must submit recalibration changes intended to standardize results for regulatory review to all areas in which a measuring system is marketed. RECOMMENDATIONS: A standardization initiative requires collaboration and planning among all interested stakeholders. Global collaboration should be further developed for prioritization of measurands for standardization, and for coordinating the production and supply of CRMs worldwide. More uniform regulatory submission requirements are desirable when recalibration is implemented to achieve internationally standardized results.


Subject(s)
Reagent Kits, Diagnostic , Humans , Reference Standards , Reference Values , Calibration
SELECTION OF CITATIONS
SEARCH DETAIL
...