Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Nat Commun ; 14(1): 3417, 2023 06 09.
Article in English | MEDLINE | ID: mdl-37296110

ABSTRACT

Long COVID or post-acute sequelae of SARS-CoV-2 (PASC) is a clinical syndrome featuring diverse symptoms that can persist for months following acute SARS-CoV-2 infection. The aetiologies may include persistent inflammation, unresolved tissue damage or delayed clearance of viral protein or RNA, but the biological differences they represent are not fully understood. Here we evaluate the serum proteome in samples, longitudinally collected from 55 PASC individuals with symptoms lasting ≥60 days after onset of acute infection, in comparison to samples from symptomatically recovered SARS-CoV-2 infected and uninfected individuals. Our analysis indicates heterogeneity in PASC and identified subsets with distinct signatures of persistent inflammation. Type II interferon signaling and canonical NF-κB signaling (particularly associated with TNF), appear to be the most differentially enriched signaling pathways, distinguishing a group of patients characterized also by a persistent neutrophil activation signature. These findings help to clarify biological diversity within PASC, identify participants with molecular evidence of persistent inflammation, and highlight dominant pathways that may have diagnostic or therapeutic relevance, including a protein panel that we propose as having diagnostic utility for differentiating inflammatory and non-inflammatory PASC.


Subject(s)
COVID-19 , Post-Acute COVID-19 Syndrome , Humans , SARS-CoV-2 , Blood Proteins , Disease Progression , Inflammation
2.
iScience ; 24(5): 102404, 2021 May 21.
Article in English | MEDLINE | ID: mdl-34113805

ABSTRACT

Multi-omic profiling of human peripheral blood is increasingly utilized to identify biomarkers and pathophysiologic mechanisms of disease. The importance of these platforms in clinical and translational studies led us to investigate the impact of delayed blood processing on the numbers and state of peripheral blood mononuclear cells (PBMC) and on the plasma proteome. Similar to previous studies, we show minimal effects of delayed processing on the numbers and general phenotype of PBMC up to 18 hours. In contrast, profound changes in the single-cell transcriptome and composition of the plasma proteome become evident as early as 6 hours after blood draw. These reflect patterns of cellular activation across diverse cell types that lead to progressive distancing of the gene expression state and plasma proteome from native in vivo biology. Differences accumulating during an overnight rest (18 hours) could confound relevant biologic variance related to many underlying disease states.

3.
bioRxiv ; 2021 Aug 19.
Article in English | MEDLINE | ID: mdl-34075380

ABSTRACT

SARS-CoV-2 has infected over 200 million and caused more than 4 million deaths to date. Most individuals (>80%) have mild symptoms and recover in the outpatient setting, but detailed studies of immune responses have focused primarily on moderate to severe COVID-19. We deeply profiled the longitudinal immune response in individuals with mild COVID-19 beginning with early time points post-infection (1-15 days) and proceeding through convalescence to >100 days after symptom onset. We correlated data from single cell analyses of peripheral blood cells, serum proteomics, virus-specific cellular and humoral immune responses, and clinical metadata. Acute infection was characterized by vigorous coordinated innate and adaptive immune activation that differed in character by age (young vs. old). We then characterized signals associated with recovery and convalescence to define and validate a new signature of inflammatory cytokines, gene expression, and chromatin accessibility that persists in individuals with post-acute sequelae of SARS-CoV-2 infection (PASC).

4.
Nucleic Acids Res ; 33(22): e187, 2005 Dec 23.
Article in English | MEDLINE | ID: mdl-16377776

ABSTRACT

The comparability and reliability of data generated using microarray technology would be enhanced by use of a common set of standards that allow accuracy, reproducibility and dynamic range assessments on multiple formats. We designed and tested a complex biological reagent for performance measurements on three commercial oligonucleotide array formats that differ in probe design and signal measurement methodology. The reagent is a set of two mixtures with different proportions of RNA for each of four rat tissues (brain, liver, kidney and testes). The design provides four known ratio measurements of >200 reference probes, which were chosen for their tissue-selectivity, dynamic range coverage and alignment to the same exemplar transcript sequence across all three platforms. The data generated from testing three biological replicates of the reagent at eight laboratories on three array formats provides a benchmark set for both laboratory and data processing performance assessments. Close agreement with target ratios adjusted for sample complexity was achieved on all platforms and low variance was observed among platforms, replicates and sites. The mixed tissue design produces a reagent with known gene expression changes within a complex sample and can serve as a paradigm for performance standards for microarrays that target other species.


Subject(s)
Gene Expression Profiling/standards , Oligonucleotide Array Sequence Analysis/standards , RNA, Messenger/standards , Animals , Gene Expression Profiling/methods , Male , Oligonucleotide Array Sequence Analysis/methods , Oligonucleotide Probes , RNA, Messenger/metabolism , Rats , Rats, Sprague-Dawley , Reference Standards , Reproducibility of Results , Tissue Distribution
5.
Nat Methods ; 1(3): 241-8, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15782200

ABSTRACT

Generation of complex libraries of defined nucleic acid sequences can greatly aid the functional analysis of protein and gene function. Previously, such studies relied either on individually synthesized oligonucleotides or on cellular nucleic acids as the starting material. As each method has disadvantages, we have developed a rapid and cost-effective alternative for construction of small-fragment DNA libraries of defined sequences. This approach uses in situ microarray DNA synthesis for generation of complex oligonucleotide populations. These populations can be recovered and either used directly or immortalized by cloning. From a single microarray, a library containing thousands of unique sequences can be generated. As an example of the potential applications of this technology, we have tested the approach for the production of plasmids encoding short hairpin RNAs (shRNAs) targeting numerous human and mouse genes. We achieved high-fidelity clone retrieval with a uniform representation of intended library sequences.


Subject(s)
Cloning, Molecular/methods , Computer Peripherals , In Situ Hybridization/methods , Oligonucleotide Array Sequence Analysis/methods , Oligonucleotide Probes/chemistry , Oligonucleotide Probes/genetics , Polymerase Chain Reaction/methods , Animals , Humans , Mice , RNA/genetics
6.
Anal Chem ; 75(17): 4672-5, 2003 Sep 01.
Article in English | MEDLINE | ID: mdl-14632079

ABSTRACT

A data anomaly was observed that affected the uniformity and reproducibility of fluorescent signal across DNA microarrays. Results from experimental sets designed to identify potential causes (from microarray production to array scanning) indicated that the anomaly was linked to a batch process; further work allowed us to localize the effect to the posthybridization array stringency washes. Ozone levels were monitored and highly correlated with the batch effect. Controlled exposures of microarrays to ozone confirmed this factor as the root cause, and we present data that show susceptibility of a class of cyanine dyes (e.g., Cy5, Alexa 647) to ozone levels as low as 5-10 ppb for periods as short as 10-30 s. Other cyanine dyes (e.g., Cy3, Alexa 555) were not significantly affected until higher ozone levels (> 100 ppb). To address this environmental effect, laboratory ozone levels should be kept below 2 ppb (e.g., with filters in HVAC) to achieve high quality microarray data.


Subject(s)
Artifacts , Atmosphere/chemistry , Carbocyanines/chemistry , Oligonucleotide Array Sequence Analysis/instrumentation , Oligonucleotide Array Sequence Analysis/standards , Ozone/analysis , Ozone/chemistry , Desiccation , Fluorescence , Quality Control , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...