Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Am J Cardiol ; 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38608800

ABSTRACT

To develop risk scoring models predicting long-term survival and major adverse cardiovascular and cerebrovascular events (MACCEs), including myocardial infarction and stroke after coronary artery bypass grafting (CABG). All 4,821 consecutive patients who underwent isolated CABG at Lankenau between January 2005 and July 2021 were included. MACCE was defined as all-cause mortality + myocardial infarction + stroke. Variable selection for both outcomes was obtained using a double-selection logit least absolute shrinkage and selection operator with adaptive selection. Model performance was internally evaluated by calibration and accuracy using bootstrap cross-validation. Mortality and MACCEs were compared in patients split into 3 groups based on the predicted risk scores for all-cause mortality and MACCEs. An external validation of our database was performed with 665 patients from the University of Brescia, Italy. Preoperative risk predictors were found to be predictors for all-cause mortality and MACCEs. In addition, being of African-American ethnicity is a significant predictor for MACCEs after isolated CABG. The areas under the curve (AUCs), which measures the discrimination of the models, were 80.4%, 79.1%, 81.3%, and 79.2% for mortality at 1, 2, 3, and 5 years follow-up. The AUCs for MACCEs were 75%, 72.5%, 73.8%, and 72.7% at 1, 2, 3, and 5 years follow-up. For external validation, the AUCs for all-cause mortality and MACCEs at 1, 2, 3, and 5 years were 73.7%, 70.8%, 68.7%, and 72.2% and 72.3%, 68.2%, 65.6%, and 69.6%, respectively. The Advanced (AD) Coronary Risk Score for All-Cause Mortality and MACCE provide good discrimination of long-term mortality and MACCEs after isolated CABG. External validation observed a more AUCs greater than 70%.

2.
J Card Surg ; 37(12): 5411-5417, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36403259

ABSTRACT

OBJECTIVES: To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement. METHODS: We reviewed on PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar for clinical trials, retrospective clinical studies, meta-analysis, and gray literature. RESULTS: Fourty-five clinical studies with 12.714 patients were included in the analysis. Thirty-day mortality ranged from 3.8% for Intuity and 3.9% for transcatheter aortic valve replacement (TAVR). The incidence of paravalvular leak (PVL) (Intuity 0% and TAVR 2.17%), permanent pacemaker implantation (Intuity 11.11% and TAVR 12.5%), stroke (Intuity 2.2% and TAVR 2.6%), myocardial infarction (MI) (Intuity 0% and TAVR 1%), were all higher in the TAVR group. Compared to other sutured bioprosthesis (SB), mortality ranged from 0% to 3.9% for Intuity and 0%-6.9% for SB. Long-term cardiac mortality ranged from 0.9% to 1.55% for Intuity and 1.4%-3.3% for the Perceval valve. The incidence of PVL (Intuity 0.24%-0.7% and Perceval 0%-1%), endocarditis (Intuity 0.2%-0.7% and Perceval 1.6%-6.6%), stroke (Intuity 0.36%-1.4% and Perceval 0%-0.8%), MI (Intuity 0.07%-0.26%), and SVD (Intuity 0.12%-0.7% and Perceval 0%) were comparable. Compared to standard full sternotomy (SFS), minimally invasive surgery (MINV) mortality ranged from 0% to 4.3% for MINV and 0%-2.1% for SFS. Hospital costs outcomes ranged from $37,187-$44,368 for the Intuity, $69,389 for TAVR, and $13,543 for SB. Intuity short-term mortality ranged between 0.9% and 12.4% while long-term mortality ranged between 2.6% and 20%. CONCLUSIONS: This manuscript provides a 360° overview of the current rapid deployments, sutureless, and TAVR prosthesis.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
3.
J Cardiothorac Vasc Anesth ; 35(11): 3223-3231, 2021 11.
Article in English | MEDLINE | ID: mdl-34175205

ABSTRACT

OBJECTIVE: To compare early and midterm outcomes of transcatheter valve-in-valve implantation (ViV-TAVI) and redo surgical aortic valve replacement (re-SAVR) for aortic bioprosthetic valve degeneration. DESIGN: Patients who underwent ViV-TAVI and re-SAVR for aortic bioprosthetic valve degeneration between January 2010 and October 2018 were retrospectively analyzed. Mean follow-up was 3.0 years. SETTING: In-hospital, early, and mid-term outcomes. PARTICIPANTS: Eighty-eight patients were included in the analysis. INTERVENTIONS: Thirty-one patients (37.3%) had ViV-TAVI, and 57 patients (62.7%) had re-SAVR. MEASUREMENTS AND MAIN RESULTS: In the ViV-TAVI group, patients were older (79.1 ± 7.4 v 67.2 ± 14.1, p < 0.01). The total operative time, intubation time, intensive care unit length of stay, total hospital length of stay, inotropes infusion, intubation >24 hours, total amount of chest tube losses, red blood cell transfusions, plasma transfusions, and reoperation for bleeding were significantly higher in the re-SAVR cohort (p < 0.01). There was no difference regarding in-hospital permanent pacemaker implantation (ViV-TAVI = 3.2% v re-SAVR = 8.8%, p = 0.27), patient-prosthesis mismatch (ViV-TAVI = 12 patients [mean 0.53 ± 0.07] and re-SAVR = ten patients [mean 0.56 ± 0.08], p = 0.4), stroke (ViV-TAVI = 3.2% v re-SAVR = 7%, p = 0.43), acute kidney injury (ViV-TAVI = 9.7% v re-SAVR = 15.8%, p = 0.1), and all-cause infections (ViV-TAVI = 0% v re-SAVR = 8.8%, p = 0.02), between the two groups. In-hospital mortality was 0% and 7% for ViV-TAVI and re-SAVR, respectively (p = 0.08). At three-years' follow-up, the incidence of pacemaker implantation was higher in the re-SAVR group (ViV-TAVI = 0 v re-SAVR = 13.4%, p < 0.01). There were no differences in reintervention (ViV-TAVI = 3.8% v re-SAVR = 0%, p = 0.32) and survival (ViV-TAVI = 83.9% v re-SAVR = 93%, p = 0.10) between the two cohorts. CONCLUSIONS: ViV-TAVI is a safe, feasible, and reliable procedure.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Retrospective Studies , Risk Factors , Treatment Outcome
6.
J Cardiothorac Surg ; 14(1): 69, 2019 Apr 08.
Article in English | MEDLINE | ID: mdl-30961635

ABSTRACT

BACKGROUND: Foreign body left after surgery surrounded by a foreign body reaction otherwise known as gossypiboma, have been first described in 1884. Although it occurs rarely, it can lead to various complications which include adhesions, abscess formation and related complications. Intrathoracic gossypiboma is a rare but serious consequence of negligence, mainly during abdominal and cardiothoracic surgery that can lead to severe medical consequences. This paper aims to raise awareness among surgeons and nurses in the operating room to prevent such errors and future complications. CASE PRESENTATION: A patient with a history of coronary arterial bypass grafting performed 14 years ago, presented with shortness of breath and dry cough. A chest X-ray revealed a large mass in the left hemithorax. The chest CT demonstrated the presence of a heterogeneous density mass of 11 cm and smooth edges in the middle mediastinum, next to the heart and partially intrapericardial. Because clinical and radiologic evidence revealed presence of a mass, we did proceed with CT guided FNA of the mass. The cytology findings confirmed an inflammatory lesion. Based on patient symptomatology and the evidence of a mass, allegedly compressing the cardiopulmonary structures in vicinity, we performed surgical exploration. An old and degraded piece of surgical swap was found and removed through an anterolateral left thoracotomy. The post-operative course was excellent. CONCLUSIONS: Forgetting surgical swaps during surgery is a medical fault. To avoid them, surgical units should design and implement a surgical inventory process to account for surgical instruments or surgical swaps. Failure to make a proper diagnosis of cases such as these can lead to further health complications in these patients. The iatrogenic foreign material seen as a mass in the radiologic films had not been previously noticed by other health professionals although the patient had undergone X-ray and cardiac ultrasound examinations in the 14 years following coronary bypass surgery. Once the causative agent was identified and removed the patient returned to normal activity.


Subject(s)
Coronary Artery Bypass/adverse effects , Foreign Bodies/diagnosis , Pericardium/pathology , Thoracotomy/methods , Foreign Bodies/etiology , Foreign Bodies/surgery , Humans , Male , Mediastinum/diagnostic imaging , Mediastinum/surgery , Middle Aged , Pericardium/surgery , Tomography, X-Ray Computed
7.
Am Surg ; 77(3): 345-7, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21375849

ABSTRACT

Babesiosis is an emerging infection most commonly acquired from a tick bite. We describe three hospitalized patients with fever attributable to babesiosis after a splenectomy. Splenectomy was done because of splenic enlargement due to unsuspected babesia infection in one patient and because of splenic perforation due to babesiosis in a second patient. The third patient underwent splenectomy for trauma and acquired babesiosis postoperatively from a blood transfusion. Our cases demonstrate the need to be vigilant for babesiosis in patients undergoing splenectomy.


Subject(s)
Babesiosis/diagnosis , Fever/parasitology , Splenectomy/adverse effects , Splenic Diseases/parasitology , Splenic Diseases/surgery , Transfusion Reaction , Babesiosis/etiology , Babesiosis/therapy , Humans , Male , Middle Aged , Splenic Diseases/diagnosis , Young Adult
8.
J Thorac Cardiovasc Surg ; 125(6): 1499-509, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12830072

ABSTRACT

BACKGROUND: We tested the hypothesis that sodium-hydrogen exchange inhibition attenuates ventricular dysfunction after ischemia-reperfusion injury in the intact porcine heart. METHODS: Twelve pigs (weight, 30-45 kg) were evenly divided into 2 groups. Baseline ventricular function studies were based on echocardiography, conductance, aortic flow, and left ventricular pressure. Animals were given vehicle (control) or benzamide-N-(aminoiminomethl)-4-(4-[2-furanylcarbonyl]-1-piperazinyl)-3-(methylsulfonyl)methanesulfonate (BIIB 513; 3 mg/kg administered intravenously). Ten minutes later, hearts were subjected to 75 seconds of ventricular fibrillation. After reperfusion for 40 minutes, function studies were repeated. Hearts were arrested and excised. Postmortem data included passive pressure-volume curves and myocardial water content. RESULTS: Preload recruitable stroke work was significantly decreased from baseline after ischemia and reperfusion in the control group (27.7 +/- 2.5 vs 48.0 +/- 5.6 mm Hg [+/- SEM], P =.001) but not in the BIIB 513 group (43.0 +/- 5.8 vs 45.5 +/- 4.1 mm Hg, P = not significant). In vivo diastolic and postmortem passive left ventricular compliance were reduced after ischemia and reperfusion for control animals but remained unchanged for animals receiving BIIB 513. Time required to recover baseline blood pressure after ventricular fibrillation was significantly longer for control animals (159 +/- 15 vs 88 +/- 14 seconds [+/- SEM], P =.008). Myocardial water content (78.97% +/- 0.94% vs 77.86% +/- 0.46% [+/- SEM]) and normalized left ventricular mass (137.24 +/- 6.17 vs 128.41 +/- 1.96 g [+/- SEM]) were insignificantly increased in control animals. CONCLUSIONS: Sodium-hydrogen exchange inhibition attenuates ventricular dysfunction after 75 seconds of ventricular fibrillation and 40 minutes of reperfusion. This family of agents might prove useful in patients with severe left ventricular dysfunction undergoing ventricular fibrillation for implantable cardioverter defibrillator testing.


Subject(s)
Mesylates/pharmacology , Sodium-Hydrogen Exchangers/antagonists & inhibitors , Ventricular Fibrillation/physiopathology , Ventricular Function/physiology , Animals , Blood Pressure/drug effects , Blood Pressure/physiology , In Vitro Techniques , Male , Stroke Volume/drug effects , Stroke Volume/physiology , Swine , Ventricular Function/drug effects , Ventricular Function, Left/drug effects , Ventricular Function, Left/physiology
9.
J Am Soc Echocardiogr ; 16(5): 442-7, 2003 May.
Article in English | MEDLINE | ID: mdl-12724653

ABSTRACT

BACKGROUND: The Doppler myocardial performance (Tei) index has been reported to be clinically useful in assessing left ventricular systolic and diastolic function in both adults and children. However, there are limited data to compare the Tei index with invasive measurements of ventricular function. We used a porcine model to directly correlate the Tei index with invasive indices of systolic and diastolic function. METHODS: Pressure volume loops were obtained from 10 pigs (32-45 kg). A micromanometer and a conductance catheter were placed in the left ventricle to record pressure and volume, respectively. A flow probe was placed around the ascending aorta to record cardiac output. Baseline pressure volume loops were generated during preload reduction through caval occlusion. Epicardial echocardiograms were performed just before the caval occlusion. Invasive indices including preload recruitable stroke work, ventricular stiffness constant, and cardiac output were assessed, as were noninvasive echocardiographic indices including Tei index and ejection fraction. An ischemic insult, ventricular fibrillation, was induced to alter ventricular function. After cardioversion and 40 minutes of reperfusion, echocardiographic and invasive measurements were repeated. RESULTS: There was a statistically significant inverse relationship between the percent change in Tei and the percent change in preload recruitable stroke work after ventricular fibrillation (r = -0.70, P =.02), although the correlation between the actual values of Tei and preload recruitable stroke work were not statistically significant. There was a statistically significant inverse relationship between the percent change in Tei and the percent change in cardiac output (r = -0.65, P =.03). There was a direct correlation between the value of Tei and the ventricular stiffness constant at baseline (r = 0.63, P <.05). As anticipated, the value of Tei was inversely related to ejection fraction by epicardial echocardiogram at baseline (r = -0.85, P <.001). The percent change in Tei was inversely related to the percent change in ejection fraction as well (r = -0.69, P <.05). CONCLUSIONS: This animal model is one of the first studies to demonstrate a direct correlation between the Tei index and systolic and diastolic invasive measurements of ventricular function. This supports the clinical use of this index as a measure of global ventricular function.


Subject(s)
Echocardiography, Doppler , Heart Function Tests , Ventricular Dysfunction, Left/diagnostic imaging , Animals , Cardiac Output , Diastole/physiology , Male , Models, Animal , Stroke Volume , Swine , Systole/physiology , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...