Org Biomol Chem ; 13(7): 1974-8, 2015 Feb 21.
Article in English | MEDLINE | ID: mdl-25537166

ABSTRACT

Chloride, bromide and iodide are inhibitors of the copper-catalysed azide-alkyne cycloaddition, with iodide exhibiting the most detrimental effects on rates and yields. A study of this inhibition is presented, along with experimental protocols to accommodate the presence of halides in this widely used reaction.

3.
J Arthroplasty ; 28(8): 1338-44, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23849509

ABSTRACT

Knee wear is commonly measured with the most recent radiograph based on the assumption that wear progresses at a constant rate. Changing patient activity or in vivo polyethylene deterioration are examples of factors that could cause wear rates to change over time. Using six or more radiographs on each of 251 knees over a mean 10-year follow-up, we determined the pattern of polyethylene wear. 92% of knees had linear wear with a mean wear rate of 0.09 ± 0.12 mm/yr. Ten knees (4%) had late accelerated wear. Knees with accelerated wear and those with a wear rate of 0.15 mm/yr or greater had lower survivorship rates. We conclude that wear is linear with rare exceptions and that higher wear is correlated with failure.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Joint/diagnostic imaging , Knee Joint/surgery , Knee Prosthesis , Prosthesis Failure , Radiography/methods , Adult , Aged , Aged, 80 and over , Data Interpretation, Statistical , Female , Follow-Up Studies , Humans , Linear Models , Male , Middle Aged , Osteoarthritis, Knee/surgery , Polyethylene , Predictive Value of Tests , Prevalence , Retrospective Studies
4.
Clin Orthop Relat Res ; 466(11): 2644-9, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18712454

ABSTRACT

UNLABELLED: The valgus, osteoarthritic knee is challenging technically and it is unknown whether and how technical and implant variables influence outcomes. We therefore determined the influence of surgical technique of soft tissue balancing and patient and implant factors from 100 unselected cruciate-retaining TKAs for valgus osteoarthritis in patients younger than 75 years of age. From 1987 to 1990, lateral soft tissue balancing was done with an outside-in progression in which the lateral collateral ligament and popliteus were typically released from the femur. From 1991 to 1994, an inside-out technique was use in which the lateral collateral ligament and/or popliteus were typically preserved. The minimum followup was 0.1 year (mean, 8.2 years; range, 0.1-18.2 years). Fourteen of 16 revisions were for wear and/or instability. Popliteus release, lateral collateral ligament release, or greater polyethylene shelf age increased the risk of revision. At 10 postoperative years, survival (end point, revision) was 89% (100 knees), 94% when the shelf age was less than 1 year (n = 73 knees), 97% when the popliteus or lateral collateral ligament was not released (n = 57 knees), and 100% when both conditions were met (n = 39 knees). Cruciate-retaining implants can be successfully used in knees with any degree of valgus osteoarthritis and survival is improved when the surgeon preserves at least one of the structures providing lateral stability in flexion and uses polyethylene with a short shelf life. LEVEL OF EVIDENCE: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Joint Instability/prevention & control , Osteoarthritis, Knee/surgery , Posterior Cruciate Ligament/surgery , Adult , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Time Factors , Treatment Outcome
5.
J Bone Joint Surg Am ; 90(7): 1543-52, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18594104

ABSTRACT

BACKGROUND: Archived serial radiographs of knee replacements provide indirect evidence of the clinical performance of ultra-high molecular weight polyethylene tibial bearings. Our purpose was to determine the loss of thickness in polyethylene tibial inserts that were of the same design but had been sterilized differently. METHODS: Four hundred and sixteen knees with an Anatomic Modular Knee primary total knee replacement had five to eighteen years of follow-up and a posterior cruciate ligament-retaining polyethylene tibial insert that had been sterilized with either gamma radiation in air (from 1987 to 1993) or gamma radiation in an inert gas (from 1993 to 1995), or by means of a nonirradiation gas-plasma method (from 1995 to 2001). Readings were taken from 1975 weight-bearing anteroposterior radiographs of the knee on which the top surface of the metal tibial tray had nearly projected as a line. In each tibiofemoral compartment, loss of polyethylene thickness was calculated as the standard thickness of the insert minus the measured magnification-corrected thickness. For each sterilization method, thickness loss was plotted versus the corresponding follow-up time, and a mixed linear regression model was used to quantify the change in thickness over time. Multiple linear regression analysis was used to determine whether loss of thickness was associated with implant factors, patient variables, and early postoperative limb alignment. RESULTS: According to the mixed model regression coefficients, loss of medial compartment thickness was greatest for inserts that had been sterilized with gamma radiation in air (0.15 mm/yr), least for those sterilized with gamma radiation in an inert gas (0.02 mm/yr), and of an intermediate magnitude for those sterilized with a nonirradiation method (0.06 mm/year); loss of lateral compartment thickness ranged from 0.03 to 0.06 mm/yr. Notably, no insert irradiated in an inert gas showed a loss of thickness of >1 mm, and no nonirradiated insert showed a loss of >2 mm. Loss of medial compartment thickness in inserts sterilized with radiation in air increased significantly with a greater polyethylene shelf age, lesser patient age, and more varus alignment of the limb in the early postoperative period (p < 0.01). CONCLUSIONS: In this total knee design, tibial polyethylene performance improved markedly after discontinuation of the gamma radiation in air sterilization technique. Future concerns are that bearings sterilized with radiation in an inert gas may oxidize in vivo and develop fatigue wear because of free radicals generated during sterilization with radiation and that nonirradiated bearings may undergo greater losses in thickness from routine burnishing since they lack the cross-linking that accompanies sterilization with radiation.


Subject(s)
Arthroplasty, Replacement, Knee , Biocompatible Materials , Joint Prosthesis , Knee Joint/diagnostic imaging , Polyethylene , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteoarthritis, Knee/surgery , Prosthesis Failure , Radiography , Sterilization
6.
Clin Orthop Relat Res ; 464: 43-52, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17876288

ABSTRACT

UNLABELLED: Many surgeons have sought to avoid valgus postoperative limb alignment when performing medial unicondylar arthroplasty under concern that such posture accelerates lateral tibiofemoral compartment joint space narrowing. To test whether postoperative limb alignment was associated with lateral compartment narrowing, we measured the lateral compartment joint space width from the most recent single-leg erect anteroposterior radiograph and similarly-obtained early postoperative radiographs of 113 medial unicompartmental arthroplasties (eight designs, 91 patients) that had a minimum of 10 years (range 10-19 years) clinical followup. The mean (+/- standard deviation) narrowing was 0.03 +/- 0.13 mm per year (< 0.10 mm per year, 89 knees) or 7% +/- 30% (< 25%, 90 knees). Narrowing increased with more valgus (less varus) of the early postoperative hip-knee-ankle angle. However, the effect of alignment was small (narrowing increased by 0.01 mm per year per each 1 degree) and it was not linked with an outcome of 25% or greater, 50% or greater, or 75% or greater narrowing. In summary, narrowing increased slightly with more valgus (less varus) early postoperative limb alignment, but limb alignment was a poor predictor of which knees would develop more complete joint space thinning. LEVEL OF EVIDENCE: Level IV, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Postoperative Complications/diagnostic imaging , Aged , Arthroplasty, Replacement, Knee/statistics & numerical data , Female , Follow-Up Studies , Humans , Incidence , Male , Middle Aged , Osteoarthritis, Knee/epidemiology , Postoperative Complications/epidemiology , Posture , Predictive Value of Tests , Radiography , Retrospective Studies , Risk Factors
7.
J Bone Joint Surg Am ; 89(6): 1306-14, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17545435

ABSTRACT

BACKGROUND: Wear of the polyethylene tibial bearing is a leading cause of failure of knee replacements done prior to the current decade. The objective of this study was to determine how patient-related factors, implant-related factors, and limb or tibial component alignment influenced the amount of thickness loss in polyethylene tibial bearings that were retrieved at the time of revision surgery or after the death of the patient. METHODS: We retrieved polyethylene tibial bearings from eighty-one unicondylar and eighty-nine total knee replacements that had been performed because of osteoarthritis with varus deformity from 1984 to 1998. All of the polyethylene bearings had been sterilized with gamma radiation in air. Polyethylene loss was quantified as the change in the minimum bearing thickness per years in vivo (the mean time in vivo [and standard deviation] was 8 +/- 4 years). Multiple linear regression was used to assess whether polyethylene loss was associated with age, weight, gender, varus angle of the tibial component, postoperative hip-knee-ankle angle, initial thickness of the polyethylene, shelf age of the polyethylene, and either the type of polyethylene (for total knee replacements, which were of one posterior cruciate ligament-retaining design) or the manufacturer (for unicondylar knee replacements), and to determine the magnitude by which polyethylene loss would change if any of the significant risk factors were changed. RESULTS: The mean loss (and standard deviation) of polyethylene thickness in the medial compartment of total knee replacements (0.33 +/- 0.28 mm/yr) and that in medial unicompartmental knee replacements (0.49 +/- 0.40 mm/yr) were significantly (p < 0.05) associated with the same three variables: patient age, postoperative hip-knee-ankle angle, and shelf age of the polyethylene. A total knee bearing with a one-year increase in shelf age, a unicondylar knee bearing with a six-month increase in shelf age, a patient who was ten years younger at the time of operation, or a limb that was aligned in 5 degrees more varus (less valgus) had similar effects on the loss of polyethylene thickness in the medial compartment; the coefficients of the linear regression equations indicated that any one of these changes would increase polyethylene loss by 0.11 to 0.14 mm/yr. CONCLUSIONS: The wear-related loss of thickness in gamma-irradiated-in-air polyethylene bearings from unicondylar and total knee replacements implanted in osteoarthritic knees with varus deformity is influenced mainly by the shelf age of the polyethylene, the age of the patient, and the postoperative angulation of the knee in the coronal plane. CLINICAL RELEVANCE: Although polyethylene bearings have not been sterilized with gamma radiation in air since the end of the last decade, many arthroplasty patients have polyethylene bearings that were sterilized with use of this method. An understanding of the findings of this study may be of value as these patients return for follow-up care. Whether the study findings have relevance to bearings sterilized with other methods is unclear and will remain so for many years. LEVEL OF EVIDENCE: Prognostic Level II.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Equipment Failure Analysis , Gamma Rays , Humans , Middle Aged , Osteoarthritis/surgery , Polyethylene , Reoperation , Tibia
8.
J Arthroplasty ; 21(6 Suppl 2): 98-107, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16950070

ABSTRACT

The goal of this report is to review reoperations undertaken on the initial 221 unicompartmental arthroplasties performed using a minimally invasive technique. A comparison was then performed between these cases and the previous 514 open medial unicompartmental arthroplasties performed at our institution. In the minimally invasive group, 9 (4.1%) of 221 knees were revised (8 for component loosening, 1 for deep infection). Of 212 unrevised knees, 16 have required a total of 18 nonrevision reoperations. Overall, 25 of 221 knees required at least 1 reoperation (total reoperation rate, 11.3%). Despite an accelerated recovery and decreased hospital stay in our minimally invasive unicompartmental arthroplasties, the rate of revision due to aseptic loosening (3.7% vs 1.0%) and the overall reoperation rate (11.3% vs 8.6%) compare unfavorably with those performed with an open technique.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Minimally Invasive Surgical Procedures/adverse effects , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/methods , Female , Humans , Knee Joint/diagnostic imaging , Length of Stay , Male , Middle Aged , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/statistics & numerical data , Radiography , Reoperation/statistics & numerical data , Retrospective Studies , Treatment Outcome
9.
J Arthroplasty ; 21(6 Suppl 2): 108-15, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16950071

ABSTRACT

The investigators reviewed 245 fixed-bearing unicondylar arthroplasties that one surgeon performed as treatment of medial compartment osteoarthritis between 1988 and 1997 using a variety of cemented metal-backed tibial components and gamma-irradiated-in-air polyethylene bearings. Multivariate statistical analysis was used to evaluate how the event of revision was influenced by 3 patient factors, 3 implant factors, and 7 factors assessed from preoperative and early postoperative radiographs. Five factors were statistically associated with revision: (younger) patient age, (thinner) tibial component initial thickness, (longer) polyethylene shelf age, (lesser) angular reduction of medial tibial plateau varus, and (more varus) postoperative hip-knee-ankle angle. Besides illustrating deleterious consequences of using gamma-irradiated-in-air polyethylene in medial unicompartmental arthroplasty, our results support reducing varus angulation of the medial tibial plateau and knee at surgery.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Osteoarthritis/surgery , Polyethylene/adverse effects , Prosthesis Failure , Age Factors , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/methods , Biomechanical Phenomena , Female , Humans , Knee Joint/diagnostic imaging , Male , Middle Aged , Multivariate Analysis , Proportional Hazards Models , Radiography , Reoperation/statistics & numerical data , Retrospective Studies , Risk Factors , Tibia/anatomy & histology , Tibia/surgery
10.
Clin Orthop Relat Res ; 452: 143-9, 2006 Nov.
Article in English | MEDLINE | ID: mdl-16924172

ABSTRACT

Unicondylar arthroplasty survival rates have varied widely. Implant- and patient-specific factors may be contributory. One surgeon placed 411 medial compartment arthroplasties of 12 designs from 1984 to 1998. In most cases, the fixed bearing tibial component was placed with cement and featured gamma-sterilized-in-air polyethylene and a metal backing. Tibial component initial thickness averaged 8.5 +/- 1.4 mm. Polyethylene shelf age averaged 1.3 +/- 1.2 years. Age and weight at arthroplasty averaged 67 +/- 8 years and 83 +/- 15 kg, respectively. Survival (no revision) at 9 years was 80%. Revision was more common in younger patients, in those with a thinner tibial component or longer polyethylene shelf age, and when some designs were used rather than others; weight and gender were not associated with revision. Nine-year survival improved to 94% when tibial component thickness was > 7 mm and polyethylene shelf age was < 1 year (154 knees). Per our experience, placement of a thin or shelf-aged gamma-irradiated-in-air polyethylene bearing into a young or active subject could explain most failures of unicondylar arthroplasties done in the 1980s and 1990s. Unicondylar patients of that era who were fortunate enough to avoid a thin or aged oxidation-prone polyethylene bearing probably have enjoyed superior outcomes.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Time Factors
11.
J Arthroplasty ; 21(3): 330-7, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16627139

ABSTRACT

Shelf aging of gamma-irradiated-in-air polyethylene tibial components has been associated with increased articular surface wear and an elevated risk for revision. Nine hundred fifty cruciate-retaining inserts of one design were implanted between 1987 and 1996 (shelf age, 1.0 +/- 1.2 years). Less frequently used inserts (smallest/largest sizes, thicker thicknesses, supplemental articular constraint) had longer shelf ages (means ranged from 1.2 to 2.6 years). Survival analysis showed that shelf age (P < .01) and gamma-sterilization in air (P = .01) elevated the risk for revision. Surgeons must remain attentive to identify the shelf-aged gamma-irradiated-in-air polyethylene tibial component while following designs from the era when this sterilization method was used. Recognition is expedited by understanding how shelf life is related to product demand and can be of aid when diagnosing the painful knee.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis/statistics & numerical data , Polyethylene , Female , Gamma Rays , Humans , Inventories, Hospital , Logistic Models , Male , Polyethylene/radiation effects , Prosthesis Design , Retrospective Studies , Risk Factors , Sterilization , Time Factors
12.
J Bone Joint Surg Am ; 87(12): 2702-2708, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16322620

ABSTRACT

BACKGROUND: Debris displaced from the articular and backside surfaces of the polyethylene inserts of modular tibial components is considered a chief cause of osteolysis at the sites of total knee arthroplasties. One design of total knee replacement featured changes, over time, in the proximal surface roughness of the tibial baseplate and the method of sterilization of the polyethylene insert. We hypothesized that polishing the baseplate surface and sterilizing the insert with means other than gamma radiation in air had reduced the prevalence of osteolysis. METHODS: Three hundred and sixty-five posterior cruciate ligament-retaining Anatomic Modular Knee primary total knee arthroplasties were performed in 300 patients from 1987 to 1998. Anteroposterior and lateral radiographs of the knees were made within a five to ten-year postoperative interval. Two arthroplasty specialists independently examined the radiographs for evidence of osteolysis (defined as any nonlinear region of cancellous bone loss with delineable margins). RESULTS: Osteolysis was identified in 34% (eighty-two) of 242 knees treated with an insert that had been gamma-irradiated in air and affixed to a rough baseplate surface, and it was identified in 9% (nine) of ninety-eight knees treated with an insert that had been gamma-irradiated in an inert gas, or had not been irradiated, and joined to a polished surface. Osteolysis was associated with six factors, including one related to the patient (male gender), one related to the tibial baseplate (the proximal surface finish), three related to the polyethylene insert (the material from which it was machined, the sterilization method, and the shelf age), and one related to the technique (hyperextension of the femoral component relative to the tibial component). CONCLUSIONS: In this design of a total knee prosthesis, polishing the tibial baseplate counterface and implementing a more contemporary sterilization practice (as opposed to gamma radiation in air) noticeably diminished but did not eliminate osteolysis.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Osteolysis/epidemiology , Aged , Arthroplasty, Replacement, Knee/instrumentation , Biocompatible Materials/adverse effects , Female , Humans , Male , Middle Aged , Osteolysis/etiology , Polyethylene/adverse effects , Prevalence , Prosthesis Design , Prosthesis Failure , Sterilization , Time Factors
13.
Clin Orthop Relat Res ; (423): 138-43, 2004 Jun.
Article in English | MEDLINE | ID: mdl-15232439

ABSTRACT

The clinical importance of the known proprioceptive deficit in patients with osteoarthritis of the knee is unclear. Attention to the factors that influence proprioception is needed to better understand the role that proprioception plays in the disease process and to assess how these deficits influence clinical outcomes of various treatment options for osteoarthritis. We hypothesized that preoperative proprioception would be poorer in knees with greater symptoms and that knees considered candidates for unicompartmental arthroplasty would have superior proprioception to those in which a total knee arthroplasty was indicated because of the less extensive disease process in the former group. Proprioceptive thresholds were measured in 119 patients with osteoarthritis and no prior knee arthroplasties who were scheduled for unicondylar or total knee arthroplasty. Proprioception examinations consisted of passively flexing and extending each of the bilateral knees in patients independently, from 45 degrees flexion until the blinded patient identified motion. Proprioceptive thresholds for flexion and extension were computed from the angular delays that elapsed before the patient recognized the stimulus. Multiple regression analysis was done to assess the association that these proprioceptive thresholds had with patient factors (age, gender, body mass index, activity level, functional capacity) and knee factors (surgical history, osteoarthritis severity, angular deformity, instability, range of motion). Patient age was the strongest predictor of proprioceptive thresholds, with older patients tending to respond slower to stimulus. Comparison of the right and left knees of each patient showed that proprioception was significantly poorer in the more symptomatic of the two knees. Preoperative thresholds did not differ between knees that received a total knee arthroplasty and those that received a unicondylar arthroplasty.


Subject(s)
Osteoarthritis, Knee/physiopathology , Proprioception/physiology , Adult , Aged , Aged, 80 and over , Analysis of Variance , Arthroplasty, Replacement, Knee , Female , Humans , Linear Models , Male , Middle Aged , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Statistics, Nonparametric
14.
J Bone Joint Surg Am ; 86(4): 763-9, 2004 Apr.
Article in English | MEDLINE | ID: mdl-15069141

ABSTRACT

BACKGROUND: A recent report linked shelf-aging of unicondylar polyethylene tibial components with accelerated fatigue wear and rapid failure. We retrospectively reviewed our experiences with another unicondylar knee system to investigate the relationship between the shelf age of the polyethylene components and clinical outcome. METHODS: One hundred Single Compartment Replacement unicompartmental knee arthroplasties were performed with cement between 1990 and 1996. The median shelf age for the polyethylene inserts was 1.7 years. At the time of the review, four knees had been lost to follow-up, sixteen were in patients who had died, and nineteen had been revised. Sixty-one knee replacements remained in situ at a mean and standard deviation of 8 +/- 2 years postoperatively. RESULTS: With revision as the end point, Kaplan-Meier survivorship analysis demonstrated a six-year rate of survival of 96% when the shelf age of the insert was less than the median shelf age but only 71% when the median shelf age was exceeded. Fatigue wear was identified on all retrieved components except for two that had shelf ages under one year and had been revised within three years. At four to six years of clinical follow-up, the group of knees in which the median shelf age had been exceeded also had poorer Knee Society knee scores and function scores. CONCLUSIONS: Aging on the shelf accelerated fatigue failure of polyethylene inserts sterilized with gamma irradiation in air and compromised our intermediate-term clinical outcomes with this unicondylar knee replacement system. Attention to the relationship between the shelf age and the clinical performance of the polyethylene component continues to be warranted with unicondylar knee arthroplasty implants.


Subject(s)
Biocompatible Materials/adverse effects , Knee Prosthesis , Polyethylene/adverse effects , Prosthesis Failure , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/instrumentation , Female , Humans , Male , Middle Aged , Retrospective Studies , Time Factors , Treatment Outcome
15.
J Bone Joint Surg Am ; 85(12): 2410-8, 2003 Dec.
Article in English | MEDLINE | ID: mdl-14668512

ABSTRACT

BACKGROUND: Radiographic measurements of the wear of total hip arthroplasty implants are indirect measurements based on radiographic determinations of the location of the femoral head relative to the acetabular component. Using the simplest case of zero wear, we assessed the reproducibility and accuracy of two software applications designed to quantify wear from clinical radiographs. METHODS: After a cobalt-chromium head was glued into the polyethylene liner of a titanium shell, one cross-table lateral radiograph and three anteroposterior pelvic radiographs were made for twelve permutations of acetabular component angulation. The three anteroposterior radiographs differed only with regard to the cephalocaudal positioning of the prosthesis relative to the x-ray tube. To assess method reproducibility, each anteroposterior radiograph was assumed to be both the initial and the latest follow-up radiograph of a wear analysis. To assess method accuracy, each anteroposterior radiograph was paired in a wear analysis with each of the two anteroposterior radiographs made when the component was in the same angulation but at a different cephalocaudal position relative to the tube (one radiograph was the initial follow-up radiograph while the second was the latest follow-up radiograph). The analyses of reproducibility and accuracy were performed both with and without inclusion of the lateral radiograph made with the component in the same angulation. RESULTS: Both methods fared well in the reproducibility analyses, with mean linear and volumetric wear values of 0.00 to 0.07 mm and 0 to 24 mm(3), respectively. In the accuracy analyses, the mean linear and volumetric wear values derived with the two methods were 0.26 to 0.40 mm and 78 to 126 mm(3), respectively. CONCLUSIONS: Whereas the results of the reproducibility analyses showed that the methods were consistent in determining the relative positions of the head and shell from a given anteroposterior radiograph or pair of anteroposterior and lateral radiographs, the non-zero wear results obtained in the accuracy analyses proved that these positional determinations were often inaccurate. Thus, while contemporary software methods may yield reproducible results, their accuracy is limited by their inability to correctly determine the position of the head relative to the acetabular component.


Subject(s)
Arthroplasty, Replacement, Hip , Compressive Strength , Equipment Failure Analysis/instrumentation , Femur Head/diagnostic imaging , Polyethylene/chemistry , Software , Analysis of Variance , Equipment Failure Analysis/methods , Hip Joint/diagnostic imaging , Hip Prosthesis , Humans , Imaging, Three-Dimensional , Models, Theoretical , Probability , Prosthesis Design , Prosthesis Failure , Radiography , Sensitivity and Specificity , Stress, Mechanical
16.
J Arthroplasty ; 18(7): 860-6, 2003 Oct.
Article in English | MEDLINE | ID: mdl-14566740

ABSTRACT

Sixty-six posterior cruciate-retaining inserts of one fixed-bearing design were revised because of wear or osteolysis. Tibial polyethylene thickness was estimated from standard anteroposterior radiographs and compared with the original or final minimum thicknesses. The most accurate method involved measuring the shortest distance from each femoral condyle to a transverse line through the middle of the baseplate's superior surface. On radiographs acquired 6 weeks after arthroplasty, the mean error was -0.1 mm (underestimate) +/- 0.6 mm (standard deviation), with 72% of the measurements within 0.5 mm of the original minimum thickness and 87% within 1.0 mm. The method was less accurate for radiographs made before revision, for which the mean error was 0.6 mm (overestimate) +/- 1.0 mm. In this study, 41% and 70% of the prerevision measurements were accurate to within 0.5 and 1.0 mm, respectively.


Subject(s)
Arthrography/methods , Biocompatible Materials/pharmacology , Knee Prosthesis , Polyethylene/pharmacology , Arthroplasty, Replacement, Knee/methods , Device Removal , Humans , Prosthesis Failure , Reoperation , Weights and Measures
17.
J Bone Joint Surg Am ; 84(10): 1849-55, 2002 Oct.
Article in English | MEDLINE | ID: mdl-12377918

ABSTRACT

BACKGROUND: Wear occurring at the interface between the polyethylene insert and metal baseplate of a modular tibial component has become an increasingly common finding at the time of revision total knee arthroplasty. Although this so-called backside wear on retrieved polyethylene inserts has been evaluated in prior studies, wear on retrieved metal baseplates has not been described, to our knowledge. The purposes of the present study were to characterize backside wear on retrieved polyethylene inserts and on the mating surfaces of their corresponding baseplates and to investigate if there is a relationship between backside wear and relative motion of the modular elements. METHODS: Twenty-nine retrieved modular tibial components of twelve fixed-bearing designs were analyzed in vitro with regard to backside wear and relative motion between the polyethylene insert and the metal baseplate. We graded the backside of each polyethylene insert and the mating surface of the metal baseplate for wear with use of a scoring system that consisted of three modes of wear and three levels of severity of wear. Relative motion between the insert and the baseplate was measured in the transverse plane with use of a mechanical testing machine. These measurements were used to compute the insert motion index, which served to quantify unrestricted motion of the insert with respect to the baseplate. RESULTS: The mean insert motion index for the tibial components was 416 micro m (range, 104 micro m to 760 micro m). On a wear-grading scale ranging from 0 to 54 (with 0 indicating no wear), the mean backside wear score was 30 (range, 12 to 48) for the inserts and 28 (range, 7 to 51) for the baseplates. Insert motion was positively correlated with backside polyethylene wear (p = 0.003) and baseplate wear (p < 0.001). Baseplate wear was strongly correlated with backside polyethylene wear (p < 0.001). CONCLUSIONS: Backside wear was correlated with the relative motion between the polyethylene insert and the metal baseplate. New locking mechanism designs directed toward better methods of securing the polyethylene insert to the tibial tray are needed to minimize the generation of particulate wear debris at the modular interface.


Subject(s)
Knee Prosthesis , Prosthesis Design , Prosthesis Failure , Adult , Aged , Arthroplasty, Replacement, Knee/adverse effects , Female , Humans , Male , Materials Testing , Metals , Middle Aged , Motion , Polyethylenes , Probability , Prospective Studies , Reoperation , Stress, Mechanical , Surface Properties , Tibia