1.
Phys Med Biol ; 68(14)2023 Jul 14.
Article in English | MEDLINE | ID: mdl-37276869

ABSTRACT

Objective.Differentiation of breast tissues is challenging in X-ray imaging because tissues might share similar or even the same linear attenuation coefficientsµ. Spectral computed tomography (CT) allows for more quantitative characterization in terms of tissue density (ρ) and effective atomic number (Zeff) by exploiting the energy dependence ofµ. The objective of this study was to examine the potential ofρ/Zeffdecomposition in spectral breast CT so as to explore the benefits of tissue characterization and improve the diagnostic accuracy of this emerging 3D imaging technique.Approach.In this work, 5 mastectomy samples and a phantom with inserts mimicking breast soft tissues were evaluated in a retrospective study. The samples were imaged at three monochromatic energy levels in the range of 24-38 keV at 5 mGy per scan using a propagation-based phase-contrast setup at SYRMEP beamline at the Italian national synchrotron Elettra.Main results.A custom-made algorithm incorporating CT reconstructions of an arbitrary number of spectral energy channels was developed to extract the density and effective atomic number of adipose, fibro-glandular, pure glandular, tumor, and skin from regions selected by a radiologist.Significance.Preliminary results suggest that, via spectral CT, it is possible to enhance tissue differentiation. It was found that adipose, fibro-glandular and tumorous tissues have average effective atomic numbers (5.94 ± 0.09, 7.03 ± 0.012, and 7.40 ± 0.10) and densities (0.90 ± 0.02, 0.96 ± 0.02, and 1.07 ± 0.03 g cm-3) and can be better distinguished if both quantitative values are observed together.


Subject(s)
Mastectomy , Tomography, X-Ray Computed , Retrospective Studies , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Imaging, Three-Dimensional
2.
J Synchrotron Radiat ; 30(Pt 3): 650-654, 2023 May 01.
Article in English | MEDLINE | ID: mdl-36952235

ABSTRACT

This work introduces a novel setup for computed tomography of heavy and bulky specimens at the SYRMEP beamline of the Italian synchrotron Elettra. All the key features of the setup are described and the first application to off-center computed tomography scanning of a human chest phantom (approximately 45 kg) as well as the first results for vertical helical acquisitions are discussed.


Subject(s)
Synchrotrons , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Phantoms, Imaging
3.
Atten Percept Psychophys ; 85(1): 152-165, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36380147

ABSTRACT

Static and dynamic cues within certain spatiotemporal proximity are used to evoke respective global percepts of form and motion. The limiting factors in this process are, first, internal noise, which indexes local orientation/direction detection, and, second, sampling efficiency, which relates to the processing and the representation of global orientation/direction. These parameters are quantified using the equivalent noise (EN) paradigm. EN has been implemented with just two levels: high and low noise. However, when using this simplified version, one must assume the shape of the overall noise dependence, as the intermediate points are missing. Here, we investigated whether two distinct EN methods, the 8-point and the simplified 2-point version, reveal comparable parameter estimates. This was performed for three different types of stimuli: random dot kinematograms, and static and dynamic translational Glass patterns, to investigate how constant internal noise estimates are, and how sampling efficiency might vary over tasks. The results indicated substantial compatibility between estimates over a wide range of external noise levels sampled with eight data points, and a simplified version producing two highly informative data points. Our findings support the use of a simplified procedure to estimate essential form-motion integration parameters, paving the way for rapid and critical applications to populations that cannot tolerate protracted measurements.


Subject(s)
Motion Perception , Humans , Motion Perception/physiology , Photic Stimulation/methods , Noise , Cues , Motion
4.
Rev Sci Instrum ; 93(11): 115109, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36461546

ABSTRACT

The scope of this paper is to outline the main marks and performances of the MagneDyn beamline, which was designed and built to perform ultrafast magnetodynamic studies in solids. Open to users since 2019, MagneDyn operates with variable circular and linear polarized femtosecond pulses delivered by the externally laser-seeded FERMI free-electron laser (FEL). The very high degree of polarization, the high pulse-to-pulse stability, and the photon energy tunability in the 50-300 eV range allow performing advanced time-resolved magnetic dichroic experiments at the K-edge of light elements, e.g., carbon and at the M- and N-edge of the 3d-transition-metals and rare earth elements, respectively. To this end, two experimental end-stations are available. The first is equipped with an in situ dedicated electromagnet, a cryostat, and an extreme ultraviolet Wollaston-like polarimeter. The second, designed for carry-in user instruments, hosts also a spectrometer for pump-probe resonant x-ray emission and inelastic spectroscopy experiments with a sub-eV energy resolution. A Kirkpatrick-Baez active optics system provides a minimum focus of ∼20×20µm2 FWHM at the sample. A pump laser setup, synchronized with the FEL-laser seeding system, delivers sub-picosecond pulses with photon energies ranging from the mid-IR to near-UV for optical pump-FEL probe experiments with a minimal pump-probe jitter of few femtoseconds. The overall combination of these features renders MagneDyn a unique state-of-the-art tool for studying ultrafast magnetic and resonant emission phenomena in solids.

5.
J Imaging ; 8(7)2022 Jul 07.
Article in English | MEDLINE | ID: mdl-35877630

ABSTRACT

In this work, we propose the software library PyPore3D, an open source solution for data processing of large 3D/4D tomographic data sets. PyPore3D is based on the Pore3D core library, developed thanks to the collaboration between Elettra Sincrotrone (Trieste) and the University of Trieste (Italy). The Pore3D core library is built with a distinction between the User Interface and the backend filtering, segmentation, morphological processing, skeletonisation and analysis functions. The current Pore3D version relies on the closed source IDL framework to call the backend functions and enables simple scripting procedures for streamlined data processing. PyPore3D addresses this limitation by proposing a full open source solution which provides Python wrappers to the the Pore3D C library functions. The PyPore3D library allows the users to fully use the Pore3D Core Library as an open source solution under Python and Jupyter Notebooks PyPore3D is both getting rid of all the intrinsic limitations of licensed platforms (e.g., closed source and export restrictions) and adding, when needed, the flexibility of being able to integrate scientific libraries available for Python (SciPy, TensorFlow, etc.).

6.
Article in English | MEDLINE | ID: mdl-35329123

ABSTRACT

OBJECTIVE: Our goal is to evaluate the effects of heat and ultraviolet (UV) irradiation on P3 facial respirator microstructure. INTERVENTION: P3 facial filters were exposed to dry heat and UV sterilization procedures. METHODS: P3 facial filter samples underwent a standardized sterilization process based on dry heat and UV irradiation techniques. We analyzed critical parameters of internal microstructure, such as fiber thickness and porosity, before and after sterilization, using 3D data obtained with synchrotron radiation-based X-ray computed microtomography (micro-CT). The analyzed filter has two inner layers called the "finer" and "coarser" layers. The "finer" layer consists of a dense fiber network, while the "coarser" layer has a less compact fiber network. RESULTS: Analysis of 3D images showed no statistically significant differences between the P3 filter of the controls and the dry heat/UV sterilized samples. In particular, averages fiber thickness in the finer layer of the control and the 60° dry heated and UV-irradiated sample groups was almost identical. Average fiber thickness for the coarser layer of the control and the 60° dry heated and UV-irradiated sample groups was very similar, measuring 19.33 µm (±0.47), 18.33 µm (±0.47), and 18.66 µm (±0.47), respectively. There was no substantial difference in maximum fiber thickness in the finer layers and coarser layers. For the control group samples, maximum thickness was on average 11.43 µm (±1.24) in the finer layer and 59.33 µm (±6.79) in the coarser layer. Similarly, the 60° dry heated group samples were thickened 12.2 µm (±0.21) in the finer layer and 57.33 µm (±1.24) in the coarser layer, while for the UV-irradiated group, the mean max thickness was 12.23 µm (±0.90) in the finer layer and 58.00 µm (±6.68) in the coarser layer. Theoretical porosity analysis resulted in 74% and 88% for the finer and coarser layers. The finer layers' theoretical porosity tended to decrease in dry heat and UV-irradiated samples compared with the respective control samples. CONCLUSIONS: Dry heat and UV sterilization processes do not substantially alter the morphometry of the P3 filter samples' internal microstructure, as studied with micro-CT. The current study suggests that safe P3 filter facepiece reusability is theoretically feasible and should be further investigated.


Subject(s)
Hot Temperature , Pandemics , Sterilization , Ultraviolet Rays , X-Ray Microtomography
7.
Neuropsychologia ; 161: 107990, 2021 10 15.
Article in English | MEDLINE | ID: mdl-34403655

ABSTRACT

Migraine is a common neurological disorder with strong links to vision. Interictal migraine is thought to be characterised by internal noise in the brain, possibly due to increased variability in neural firing, which can be estimated using equivalent noise tasks. High-frequency transcranial random noise stimulation (hf-tRNS) can be used to modulate levels of internal noise in the brain, and so presents a possible therapy to redress noise levels in the migraine brain. This is a case-control study using a 2-alternative forced choice (2AFC) design. Hf-tRNS and Sham control stimulation were used alongside a global motion direction discrimination task and visually based equivalent noise tasks. The migraine group demonstrated increased baseline internal noise levels compared to the control group. Internal noise levels, and sampling, were reduced using hf-tRNS but not Sham stimulation. However, there were no differences in terms of coherence thresholds, slopes, and lapse rate for global motion discrimination between the two groups. This is the first demonstration of the possibility of decreasing internal noise levels in migraine using hf-tRNS. Future work could explore the possibility of neurostimulation as a therapy for migraine.


Subject(s)
Migraine Disorders , Transcranial Direct Current Stimulation , Brain , Case-Control Studies , Humans , Migraine Disorders/therapy , Visual Perception
8.
Med Phys ; 48(9): 5343-5355, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34252212

ABSTRACT

PURPOSE: The SYRMA-3D collaboration is setting up a breast computed tomography (bCT) clinical program at the Elettra synchrotron radiation facility in Trieste, Italy. Unlike the few dedicated scanners available at hospitals, synchrotron radiation bCT requires the patient's rotation, which in turn implies a long scan duration (from tens of seconds to few minutes). At the same time, it allows the achievement of high spatial resolution. These features make synchrotron radiation bCT prone to motion artifacts. This article aims at assessing and compensating for motion artifacts through an optical tracking approach. METHODS: In this study, patients' movements due to breathing have been first assessed on seven volunteers and then simulated during the CT scans of a breast phantom and a surgical specimen, by adding a periodic oscillatory motion (constant speed, 1 mm amplitude, 12 cycles/minute). CT scans were carried out at 28 keV with a mean glandular dose of 5 mGy. Motion artifacts were evaluated and a correction algorithm based on the optical tracking of fiducial marks was introduced. A quantitative analysis based on the structural similarity (SSIM) index and the normalized mean square error (nMSE) was performed on the reconstructed CT images. RESULTS: CT images reconstructed through the optical tracking procedure were found to be as good as the motionless reference image. Moreover, the analysis of SSIM and nMSE demonstrated that an uncorrected motion of the order of the system's point spread function (around 0.1 mm in the present case) can be tolerated. CONCLUSIONS: Results suggest that a motion correction procedure based on an optical tracking system would be beneficial in synchrotron radiation bCT.


Subject(s)
Artifacts , Synchrotrons , Algorithms , Breast/diagnostic imaging , Breast/surgery , Humans , Phantoms, Imaging , Tomography, X-Ray Computed
9.
Iperception ; 12(3): 20416695211017924, 2021.
Article in English | MEDLINE | ID: mdl-34104382

ABSTRACT

Glass patterns (GPs) have been widely employed to investigate the mechanisms underlying processing of global form from locally oriented cues. The current study aimed to psychophysically investigate the level at which global orientation is extracted from translational GPs using the tilt after-effect (TAE) and manipulating the spatiotemporal properties of the adapting pattern. We adapted participants to translational GPs and tested with sinewave gratings. In Experiment 1, we investigated whether orientation-selective units are sensitive to the temporal frequency of the adapting GP. We used static and dynamic translational GPs, with dynamic GPs refreshed at different temporal frequencies. In Experiment 2, we investigated the spatial frequency selectivity of orientation-selective units by manipulating the spatial frequency content of the adapting GPs. The results showed that the TAE peaked at a temporal frequency of ∼30 Hz, suggesting that orientation-selective units responding to translational GPs are sensitive to high temporal frequencies. In addition, TAE from translational GPs peaked at lower spatial frequencies than the dipoles' spatial constant. These effects are consistent with form-motion integration at low and intermediate levels of visual processing.

10.
J Synchrotron Radiat ; 26(Pt 4): 1343-1353, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31274463

ABSTRACT

Breast computed tomography (BCT) is an emerging application of X-ray tomography in radiological practice. A few clinical prototypes are under evaluation in hospitals and new systems are under development aiming at improving spatial and contrast resolution and reducing delivered dose. At the same time, synchrotron-radiation phase-contrast mammography has been demonstrated to offer substantial advantages when compared with conventional mammography. At Elettra, the Italian synchrotron radiation facility, a clinical program of phase-contrast BCT based on the free-space propagation approach is under development. In this paper, full-volume breast samples imaged with a beam energy of 32 keV delivering a mean glandular dose of 5 mGy are presented. The whole acquisition setup mimics a clinical study in order to evaluate its feasibility in terms of acquisition time and image quality. Acquisitions are performed using a high-resolution CdTe photon-counting detector and the projection data are processed via a phase-retrieval algorithm. Tomographic reconstructions are compared with conventional mammographic images acquired prior to surgery and with histologic examinations. Results indicate that BCT with monochromatic beam and free-space propagation phase-contrast imaging provide relevant three-dimensional insights of breast morphology at clinically acceptable doses and scan times.


Subject(s)
Mammography/methods , Microscopy, Phase-Contrast/methods , X-Ray Microtomography/methods , Cadmium Compounds/chemistry , Female , Humans , Synchrotrons , Tellurium/chemistry
11.
Phys Med Biol ; 64(15): 155011, 2019 08 07.
Article in English | MEDLINE | ID: mdl-31234148

ABSTRACT

A quantitative characterization of the soft tissues composing the human breast is achieved by means of a monochromatic CT phase-contrast imaging system, through accurate measurements of their attenuation coefficients within the energy range of interest for breast CT clinical examinations. Quantitative measurements of linear attenuation coefficients are performed on tomographic reconstructions of surgical samples, using monochromatic x-ray beams from a synchrotron source and a free space propagation setup. An online calibration is performed on the obtained reconstructions, in order to reassess the validity of the standard calibration procedure of the CT scanner. Three types of healthy tissues (adipose, glandular, and skin) and malignant tumors, when present, are considered from each sample. The measured attenuation coefficients are in very good agreement with the outcomes of similar studies available in the literature, although they span an energy range that was mostly neglected in the previous studies. No globally significant differences are observed between healthy and malignant dense tissues, although the number of considered samples does not appear sufficient to address the issue of a quantitative differentiation of tumors. The study assesses the viability of the proposed methodology for the measurement of linear attenuation coefficients, and provides a denser sampling of attenuation data in the energy range useful to breast CT.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Tomography, X-Ray Computed/methods , Breast/pathology , Female , Humans , Synchrotrons , Tomography Scanners, X-Ray Computed , Tomography, X-Ray Computed/instrumentation
12.
Sci Rep ; 9(1): 6027, 2019 04 15.
Article in English | MEDLINE | ID: mdl-30988353

ABSTRACT

In this study, we investigated visual short-term memory for coherent motion in action video game players (AVGPs), non-action video game players (NAVGPs), and non-gamers (control group: CONs). Participants performed a visual memory-masking paradigm previously used with macaque monkeys and humans. In particular, we tested whether video game players form a more robust visual short-term memory trace for coherent moving stimuli during the encoding phase, and whether such memory traces are less affected by an intervening masking stimulus presented 0.2 s after the offset of the to-be-remembered sample. The results showed that task performance of all groups was affected by the masking stimulus, but video game players were affected to a lesser extent than controls. Modelling of performance values and reaction times revealed that video game players have a lower guessing rate than CONs, and higher drift rates than CONs, indicative of more efficient perceptual decisions. These results suggest that video game players exhibit a more robust VSTM trace for moving objects and this trace is less prone to external interference.


Subject(s)
Memory, Short-Term , Video Games , Visual Perception , Attention , Female , Humans , Male , Motion , Psychomotor Performance , Reaction Time , Task Performance and Analysis
13.
Brain Stimul ; 12(4): 967-977, 2019.
Article in English | MEDLINE | ID: mdl-30833217

ABSTRACT

BACKGROUND: High-frequency transcranial random noise stimulation (hf-tRNS) is a neuromodulatory technique consisting of the application of alternating current at random intensities and frequencies. hf-tRNS induces random neural activity in the system that may boost the sensitivity of neurons to weak inputs. Stochastic resonance is a nonlinear phenomenon whereby the addition of an optimal amount of noise results in performance enhancement, whereas further noise increments impair signal detection or discrimination. OBJECTIVE: The aim of the study was to assess whether modulatory effects of hf-tRNS rely on the stochastic resonance phenomenon, and what is the specific neural mechanism producing stochastic resonance. METHOD: Observers performed a two-interval forced choice motion direction discrimination task in which they had to report whether two moving patches presented in two temporal intervals had the same or different motion directions. hf-tRNS was administered at five intensity levels (0.5, 0.75, 1.0, 1.5, and 2.25 mA). RESULTS: The results showed a significant improvement in performance when hf-tRNS was applied at 1.5 mA, representing the optimal level of external noise. However, stimulation intensity at 2.25 mA significantly impaired direction discrimination performance. An equivalent noise (EN) analysis, used to assess how hf-tRNS modulates the mechanisms underlying global motion processing, showed an increment in motion signal integration with the optimal current intensity, but reduced motion signal integration at 2.25 mA. CONCLUSION: These results indicate that hf-tRNS-induced noise modulates neural signal-to-noise ratio in a way that is compatible with the stochastic resonance phenomenon.


Subject(s)
Motion Perception/physiology , Noise , Photic Stimulation/methods , Transcranial Direct Current Stimulation/methods , Adolescent , Adult , Female , Humans , Male , Stochastic Processes , Visual Perception/physiology , Young Adult
14.
Perception ; 48(4): 286-315, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30885042

ABSTRACT

Glass patterns (GPs) consist of randomly distributed dot pairs (dipoles) whose orientations are determined by specific geometric transforms. We investigated the role of visuospatial attention in the processing of global form from GPs by measuring the effect of distraction on adaptation to GPs. In the nondistracted condition, observers were adapted to coherent GPs. After the adaptation period, they were presented with a test GP divided in two halves along the vertical and were required to judge which side of the test GP was more coherent. In the attention-distracted condition, a high-load rapid serial visual presentation task was performed during the adapting period. The magnitude of the form after-effect was measured using a technique that measures the coherence level at which the test GP appears random. The rationale was that if attention has a modulatory effect on the spatial summation of dipoles, in the attention-distracted condition, we should expect a weaker form after-effect. However, the results showed stronger form after-effect in the attention-distracted condition than in the nondistracted condition, suggesting that distraction during adaptation increases the strength of form adaptation. Additional experiments suggested that distraction may reduce the spatial suppression from large-scale textures, strengthening the spatial summation of local-oriented signals.


Subject(s)
Attention/physiology , Figural Aftereffect/physiology , Form Perception/physiology , Pattern Recognition, Visual/physiology , Adult , Humans , Young Adult
15.
J Med Imaging (Bellingham) ; 6(3): 031402, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30525064

ABSTRACT

A program devoted to performing the first in vivo synchrotron radiation (SR) breast computed tomography (BCT) is ongoing at the Elettra facility. Using the high spatial coherence of SR, phase-contrast (PhC) imaging techniques can be used. The latest high-resolution BCT acquisitions of breast specimens, obtained with the propagation-based PhC approach, are herein presented as part of the SYRMA-3D collaboration effort toward the clinical exam. Images are acquired with a 60 - µ m pixel dead-time-free single-photon-counting CdTe detector. The samples are imaged at 32 and 38 keV in a continuous rotating mode, delivering 5 to 20 mGy of mean glandular dose. Contrast-to-noise ratio (CNR) and spatial resolution performances are evaluated for both PhC and phase-retrieved images, showing that by applying the phase-retrieval algorithm a five-time CNR increase can be obtained with a minor loss in spatial resolution across soft tissue interfaces. It is shown that, despite having a poorer CNR, PhC images can provide a sharper visualization of microcalcifications, thus being complementary to phase-retrieved images. Furthermore, the first full-volume scan of a mastectomy sample ( 9 × 9 × 3 cm 3 ) is reported. This investigation into surgical specimens indicates that SR BCT in terms of CNR, spatial resolution, scan duration, and scan volume is feasible.

16.
Phys Med Biol ; 63(24): 24NT03, 2018 Dec 18.
Article in English | MEDLINE | ID: mdl-30524112

ABSTRACT

X-ray phase imaging has the potential to dramatically improve soft tissue contrast sensitivity, which is a crucial requirement in many diagnostic applications such as breast imaging. In this context, a program devoted to perform in vivo phase-contrast synchrotron radiation breast computed tomography is ongoing at the Elettra facility (Trieste, Italy). The used phase-contrast technique is the propagation-based configuration, which requires a spatially coherent source and a sufficient object-to-detector distance. In this work the effect of this distance on image quality is quantitatively investigated scanning a large breast surgical specimen at three object-to-detector distances (1.6, 3, 9 m) and comparing the images both before and after applying the phase-retrieval procedure. The sample is imaged at 30 keV with a [Formula: see text] pixel pitch CdTe single-photon-counting detector, positioned at a fixed distance of 31.6 m from the source. The detector fluence is kept constant for all acquisitions. The study shows that, at the largest distance, a 20-fold SNR increase can be obtained by applying the phase-retrieval procedure. Moreover, it is shown that, for phase-retrieved images, changing the object-to-detector distance does not affect spatial resolution while boosting SNR (four-fold increase going from the shortest to the largest distance). The experimental results are supported by a theoretical model proposed by other authors, whose salient results are presented in this paper.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/abnormalities , Hypertrophy/diagnostic imaging , Image Processing, Computer-Assisted/methods , Microscopy, Phase-Contrast/methods , Quantum Dots , Synchrotrons/instrumentation , Tomography, X-Ray Computed/methods , Breast/diagnostic imaging , Female , Humans , Models, Theoretical
17.
Radiol Oncol ; 52(3): 329-336, 2018 03 24.
Article in English | MEDLINE | ID: mdl-30210044

ABSTRACT

Background The SYRMA-3D collaboration is setting up the first clinical trial of phase-contrast breast CT with synchrotron radiation at the Elettra synchrotron facility in Trieste, Italy. In this communication, a quality control protocol for breast CT is proposed, and a first test of image quality measurements is performed by means of a custom-made radiographic phantom. Materials and methods A set of projections is acquired and used to perform a CT reconstruction of two selected portions of the phantom. Such portions contain a uniform layer of water and a set of radiographic inserts, respectively. Together, they allow to perform several image quality measurements, namely CT number linearity, reconstruction accuracy, uniformity, noise, and low contrast resolution. All measurements are repeated at different beam energies in the range of interest, and at two different dose values. Results Measurements show a good linearity in the soft tissue range, paired to a high accuracy of the CT number reconstruction. Uniformity and noise measurements show that reconstruction inhomogeneities are bound to a few percent of the average pixel values. However, low contrast detectability is limited to the higher portion of the explored energy range. Conclusions The results of the measurements are satisfactory in terms of their quality, feasibility and reproducibility. With minimal modifications, the phantom is promising to allow a set of image quality measurements to be used in the upcoming clinical trial.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Quality Control , Tomography, X-Ray Computed/standards , Female , Humans , Phantoms, Imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Synchrotrons
18.
Brain Stimul ; 11(6): 1263-1275, 2018.
Article in English | MEDLINE | ID: mdl-30078542

ABSTRACT

BACKGROUND: High frequency transcranial random noise stimulation (hf-tRNS) facilitates performance in several perceptual and cognitive tasks, however, little is known about the underlying modulatory mechanisms. OBJECTIVE: In this study we compared the effects of hf-tRNS to those of anodal and cathodal tDCS in a global motion direction discrimination task. An equivalent noise (EN) paradigm was used to assess how hf-tRNS modulates the mechanisms underlying local and global motion processing. METHOD: Motion coherence threshold and slope of the psychometric function were estimated using an 8AFC task in which observers had to discriminate the motion direction of a random dot kinematogram presented either in the left or right visual hemi-field. During the task hf-tRNS, anodal and cathodal tDCS were delivered over the left hMT+. In a subsequent experiment we implemented an EN paradigm in order to investigate the effects of hf-tRNS on the mechanisms involved in visual motion integration (i.e., internal noise and sampling). RESULTS: hf-tRNS reduced the motion coherence threshold but did not affect the slope of the psychometric function, suggesting no modulation of stimulus discriminability. Anodal and cathodal tDCS did not produce any modulatory effects. EN analysis in the last experiment found that hf-tRNS modulates sampling but not internal noise, suggesting that hf-tRNS modulates the integration of local motion cues. CONCLUSION: hf-tRNS interacts with the output neurons tuned to directions near to the directional signal, incrementing the signal-to-noise ratio and the pooling of local motion cues and thus increasing the sensitivity for global moving stimuli.


Subject(s)
Motion Perception/physiology , Photic Stimulation/methods , Psychomotor Performance/physiology , Transcranial Direct Current Stimulation/methods , Adult , Female , Humans , Male
19.
Phys Med Biol ; 63(16): 165020, 2018 08 23.
Article in English | MEDLINE | ID: mdl-29972144

ABSTRACT

We present a comparison between full field digital mammography and synthetic mammography, performed on several mammography systems from four different manufacturers. The analysis is carried out on both the digital and synthetic images of two commercially available mammography phantoms, and focuses on a set of objective metrics that encode the geometrical appearance of imaging features of diagnostic interest. In particular, we measured sizes and contrasts of several clusters of microcalcification specks, shapes and contrasts of circular masses, and the power spectrum of background regions mimicking the heterogeneous texture of the breast parenchyma. Despite the potential issues of tomosynthesis in terms of image blurring, the synthetic images do not highlight any globally significant differences in the rendering of the details of interest, when compared to the original digital mammograms: relative contrasts are generally preserved, as well as the geometry of broad structures. We conclude that, as far as the considered objective metrics are concerned, the image quality of synthetic mammography does not exhibit significant differences with respect to the one of full field digital mammography, for all the considered systems.


Subject(s)
Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Image Processing, Computer-Assisted/methods , Mammography/methods , Mammography/standards , Phantoms, Imaging , Quality Control , Female , Humans , Radiographic Image Enhancement/methods
20.
Phys Med ; 45 Suppl 1: S2-S3, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29413851

ABSTRACT

Advanced applications of digital mammography such as dual-energy and tomosynthesis require multiple exposures and thus deliver higher dose compared to standard mammograms. A straightforward manner to reduce patient dose without affecting image quality would be removal of the anti-scatter grid, provided that the involved reconstruction algorithms are able to take the scatter figure into account [1]. Monte Carlo simulations are very well suited for the calculation of X-ray scatter distribution and can be used to integrate such information within the reconstruction software. Geant4 is an open source C++ particle tracking code widely used in several physical fields, including medical physics [2,3]. However, the coherent scattering cross section used by the standard Geant4 code does not take into account the influence of molecular interference. According to the independent atomic scattering approximation (the so-called free-atom model), coherent radiation is indistinguishable from primary radiation because its angular distribution is peaked in the forward direction. Since interference effects occur between x-rays scattered by neighbouring atoms in matter, it was shown experimentally that the scatter distribution is affected by the molecular structure of the target, even in amorphous materials. The most important consequence is that the coherent scatter distribution is not peaked in the forward direction, and the position of the maximum is strongly material-dependent [4]. In this contribution, we present the implementation of a method to take into account inter-atomic interference in small-angle coherent scattering in Geant4, including a dedicated data set of suitable molecular form factor values for several materials of clinical interest. Furthermore, we present scatter images of simple geometric phantoms in which the Rayleigh contribution is rigorously evaluated.

SELECTION OF CITATIONS