Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
J Mech Behav Biomed Mater ; 142: 105810, 2023 06.
Article in English | MEDLINE | ID: mdl-37028122

ABSTRACT

Studies of osteoarthritis initiation and progression that measure strain in cartilage require physiological loading levels. Many studies use magnetic resonance (MR) imaging, which necessitates a MR-compatible loading device. In this study, the design and validation of a new device, the cartilage compressive actuator (CCA), is presented. The CCA is designed for high-field (e.g., 9.4 T) small-bore MR scanners, and meets a number of design criteria. These criteria include capability for testing bone-cartilage samples, MR compatibility, constant load and incremental strain application, a water-tight specimen chamber, remote control, and real time displacement feedback. The mechanical components in the final design include an actuating piston, a connecting chamber, and a sealed specimen chamber. An electro-pneumatic system applies compression, and an optical Fibre-Bragg grating (FBG) sensor provides live displacement feedback. A logarithmic relationship was observed between force exerted by the CCA and pressure (R2 = 0.99), with a peak output force of 653 ± 2 N. The relationship between FBG sensor wavelength and displacement was linear when calibrated both outside (R2 = 0.99) and inside (R2 = 0.98) the MR scanner. Average slope was similar between the two validation tests, with a slope of -4.2 nm/mm observed inside the MR scanner and -4.3 to -4.5 nm/mm observed outside the MR scanner. This device meets all design criteria and represents an improvement over published designs. Future work should incorporate a closed feedback loop to allow for cyclical loading of specimens.


Subject(s)
Cartilage, Articular , Osteoarthritis , Humans , Magnetic Resonance Imaging , Cartilage, Articular/diagnostic imaging , Cartilage, Articular/physiology , Osteoarthritis/diagnostic imaging
2.
Sci Rep ; 13(1): 4241, 2023 03 14.
Article in English | MEDLINE | ID: mdl-36918604

ABSTRACT

As part of the COVID-19 pandemic, clinical laboratories have been faced with massive increases in testing, resulting in sample collection systems, reagent, and staff shortages. We utilized self-collected saline gargle samples to optimize high throughput SARS-CoV-2 multiplex polymerase chain reaction (PCR) testing in order to minimize cost and technologist time. This was achieved through elimination of nucleic acid extraction and automation of sample handling on a widely available robotic liquid handler, Hamilton STARlet. A customized barcode scanning script for reading the sample ID by the Hamilton STARlet's software system was developed to allow primary tube sampling. Use of pre-frozen SARS-CoV-2 assay reaction mixtures reduced assay setup time. In both validation and live testing, the assay produced no false positive or false negative results. Of the 1060 samples tested during validation, 3.6% (39/1060) of samples required retesting as they were either single gene positive, had internal control failure or liquid aspiration error. Although the overall turnaround time was only slightly faster in the automated workflow (185 min vs 200 min), there was a 76% reduction in hands-on time, potentially reducing staff fatigue and burnout. This described process from sample self-collection to automated direct PCR testing significantly reduces the total burden on healthcare systems in terms of human resources and reagent requirements.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , Pandemics , COVID-19 Testing , Specimen Handling , Multiplex Polymerase Chain Reaction , Sensitivity and Specificity , RNA, Viral/analysis
3.
J Appl Lab Med ; 7(5): 1025-1036, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35723286

ABSTRACT

BACKGROUND: To support the implementation of high-throughput pipelines suitable for SARS-CoV-2 sequencing and analysis in a clinical laboratory, we developed an automated sample preparation and analysis workflow. METHODS: We used the established ARTIC protocol with approximately 400 bp amplicons sequenced on Oxford Nanopore's MinION. Sequences were analyzed using Nextclade, assigning both a clade and quality score to each sample. RESULTS: A total of 2179 samples on twenty-five 96-well plates were sequenced. Plates of purified RNA were processed within 12 h, sequencing required up to 24 h, and analysis of each pooled plate required 1 h. The use of samples with known threshold cycle (Ct) values enabled normalization, acted as a quality control check, and revealed a strong correlation between sample Ct values and successful analysis, with 85% of samples with Ct < 30 achieving a "good" Nextclade score. Less abundant samples responded to enrichment with the fraction of Ct > 30 samples achieving a "good" classification rising by 60% after addition of a post-ARTIC PCR normalization. Serial dilutions of 3 variant of concern samples, diluted from approximately Ct = 16 to approximately Ct = 50, demonstrated successful sequencing to Ct = 37. The sample set contained a median of 24 mutations per sample and a total of 1281 unique mutations with reduced sequence read coverage noted in some regions of some samples. A total of 10 separate strains were observed in the sample set, including 3 variants of concern prevalent in British Columbia in the spring of 2021. CONCLUSIONS: We demonstrated a robust automated sequencing pipeline that takes advantage of input Ct values to improve reliability.


Subject(s)
COVID-19 , Nanopore Sequencing , Nanopores , COVID-19/diagnosis , COVID-19/epidemiology , Humans , Reproducibility of Results , SARS-CoV-2/genetics
4.
Cell Rep Methods ; 2(1): 100150, 2022 01 24.
Article in English | MEDLINE | ID: mdl-35474869

ABSTRACT

Single-cell Strand-seq generates directional genomic information to study DNA repair, assemble genomes, and map structural variation onto chromosome-length haplotypes. We report a nanoliter-volume, one-pot (OP) Strand-seq library preparation protocol in which reagents are added cumulatively, DNA purification steps are avoided, and enzymes are inactivated with a thermolabile protease. OP-Strand-seq libraries capture 10%-25% of the genome from a single-cell with reduced costs and increased throughput.


Subject(s)
Genomics , Genomics/methods , Haplotypes
5.
Front Genet ; 12: 665888, 2021.
Article in English | MEDLINE | ID: mdl-34149808

ABSTRACT

RNA sequencing (RNAseq) has been widely used to generate bulk gene expression measurements collected from pools of cells. Only relatively recently have single-cell RNAseq (scRNAseq) methods provided opportunities for gene expression analyses at the single-cell level, allowing researchers to study heterogeneous mixtures of cells at unprecedented resolution. Tumors tend to be composed of heterogeneous cellular mixtures and are frequently the subjects of such analyses. Extensive method developments have led to several protocols for scRNAseq but, owing to the small amounts of RNA in single cells, technical constraints have required compromises. For example, the majority of scRNAseq methods are limited to sequencing only the 3' or 5' termini of transcripts. Other protocols that facilitate full-length transcript profiling tend to capture only polyadenylated mRNAs and are generally limited to processing only 96 cells at a time. Here, we address these limitations and present a novel protocol that allows for the high-throughput sequencing of full-length, total RNA at single-cell resolution. We demonstrate that our method produced strand-specific sequencing data for both polyadenylated and non-polyadenylated transcripts, enabled the profiling of transcript regions beyond only transcript termini, and yielded data rich enough to allow identification of cell types from heterogeneous biological samples.

6.
Cell ; 179(5): 1207-1221.e22, 2019 Nov 14.
Article in English | MEDLINE | ID: mdl-31730858

ABSTRACT

Accurate measurement of clonal genotypes, mutational processes, and replication states from individual tumor-cell genomes will facilitate improved understanding of tumor evolution. We have developed DLP+, a scalable single-cell whole-genome sequencing platform implemented using commodity instruments, image-based object recognition, and open source computational methods. Using DLP+, we have generated a resource of 51,926 single-cell genomes and matched cell images from diverse cell types including cell lines, xenografts, and diagnostic samples with limited material. From this resource we have defined variation in mitotic mis-segregation rates across tissue types and genotypes. Analysis of matched genomic and image measurements revealed correlations between cellular morphology and genome ploidy states. Aggregation of cells sharing copy number profiles allowed for calculation of single-nucleotide resolution clonal genotypes and inference of clonal phylogenies and avoided the limitations of bulk deconvolution. Finally, joint analysis over the above features defined clone-specific chromosomal aneuploidy in polyclonal populations.


Subject(s)
DNA Replication/genetics , Genome, Human , High-Throughput Nucleotide Sequencing , Single-Cell Analysis , Aneuploidy , Animals , Cell Cycle/genetics , Cell Line, Tumor , Cell Shape , Cell Survival , Chromosomes, Human/genetics , Clone Cells , DNA Transposable Elements/genetics , Diploidy , Female , Genotype , Humans , Male , Mice , Mutation/genetics , Phylogeny , Polymorphism, Single Nucleotide/genetics
7.
Genes (Basel) ; 8(12)2017 Dec 11.
Article in English | MEDLINE | ID: mdl-29232880

ABSTRACT

The northern sea otter inhabits coastal waters of the northern Pacific Ocean and is the largest member of the Mustelidae family. DNA sequencing methods that utilize microfluidic partitioned and non-partitioned library construction were used to establish the sea otter genome. The final assembly provided 2.426 Gbp of highly contiguous assembled genomic sequences with a scaffold N50 length of over 38 Mbp. We generated transcriptome data derived from a lymphoma to aid in the determination of functional elements. The assembled genome sequence and underlying sequence data are available at the National Center for Biotechnology Information (NCBI) under the BioProject accession number PRJNA388419.

8.
Genes (Basel) ; 8(12)2017 Dec 11.
Article in English | MEDLINE | ID: mdl-29232881

ABSTRACT

The beluga whale is a cetacean that inhabits arctic and subarctic regions, and is the only living member of the genus Delphinapterus. The genome of the beluga whale was determined using DNA sequencing approaches that employed both microfluidic partitioning library and non-partitioned library construction. The former allowed for the construction of a highly contiguous assembly with a scaffold N50 length of over 19 Mbp and total reconstruction of 2.32 Gbp. To aid our understanding of the functional elements, transcriptome data was also derived from brain, duodenum, heart, lung, spleen, and liver tissue. Assembled sequence and all of the underlying sequence data are available at the National Center for Biotechnology Information (NCBI) under the Bioproject accession number PRJNA360851A.

9.
Injury ; 47(10): 2195-2202, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27496724

ABSTRACT

OBJECTIVES: We hypothesize that inserting a curved intramedullary internal fixation device which follows curved osseous fixation paths (OFPs) would be more versatile and mechanically stronger than straight screws for fixation of pelvic ring and acetabular injuries. This study characterizes the dimensions of curved OFPs of the pelvic ring and acetabulum and suggests design parameters for such a curved device. METHODS: CT scans of intact pelves of 50 female and 50 male subjects were studied using MIM Maestro™ and Solidworks™ to determine the constriction points (smallest cross sections) and the tightest radii of curvature (RoC) in the anterior column, posterior column, iliosacral and pubic symphysis OFPs. RESULTS: The constriction point diameters for the superior pubic ramus and supra-acetabular areas were 13±3mm and 12±3mm, respectively. The anterior column RoC was greater than 65mm in all cases. The minimum observed RoC for the path from one ilium, across the SI joint, the sacrum and to the other ilium was 71mm, with 99% of the cases having a RoC of at least 80mm, in both the inlet and outlet views. CONCLUSION: This study shows that if a flexible implant which could be stiffened once in place was available, it would enable the use of larger and longer fixation taking advantage of the pelvis's curved intracortical spaces. Even for dysmorphic pelves, accessible tunnels support a long, strong, curved fixation device.


Subject(s)
Equipment Design/instrumentation , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Pelvic Bones/anatomy & histology , Bone Screws , Feasibility Studies , Female , Fracture Fixation, Internal/methods , Fractures, Bone/diagnostic imaging , Humans , Internal Fixators , Male , Pelvic Bones/diagnostic imaging , Pelvic Bones/surgery , Reference Values , Tomography, X-Ray Computed
10.
Electrophoresis ; 26(11): 2128-37, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15852354

ABSTRACT

High-throughput capillary array electrophoresis (CAE) instruments for DNA sequencing suffer to varying degrees from read length degradation associated with electrophoretic current decline and inhibition or delay in the arrival of fragments at the detector. This effect is known to be associated with residual amounts of large, slow-moving fragments of template or genomic DNA carried through from sample preparation and sequencing reactions. Here, we investigate the creation and expansion of an ionic depletion region induced by overloading the capillary with low-mobility DNA fragments, and the effect of growth of this region on electrophoresis run failure. Slow-moving fragments are analytically and experimentally shown to reduce the ionic concentration of the downstream electrolyte. With injection of large fragments beyond a threshold quantity, the anode-side boundary of the nascent depletion region begins to propagate toward the anode at a rate faster than the contaminant DNA migration. Under such conditions, the depletion region expands, the capillary current declines dramatically, and the electrophoresis run yields a short read length or fails completely.


Subject(s)
DNA/standards , Electrophoresis, Capillary/methods , DNA/chemistry , DNA/isolation & purification , Electrophoresis, Capillary/standards , Equipment Failure Analysis , Nucleic Acid Denaturation , Sequence Analysis, DNA
11.
Appl Opt ; 41(25): 5357-61, 2002 Sep 01.
Article in English | MEDLINE | ID: mdl-12211564

ABSTRACT

Retroreflective images are useful in outdoor application for which high legibility is required both during the day and in response to vehicular illumination. To date, all variable message retroreflective images have employed mechanical shutters as the switching mechanism. As an alternative, we propose a method for switching the total internal reflection effect used in retroreflectors by means of pneumatic actuation of surface treated polydimethylsiloxane gel. This approach is both effective and compatible with current large-scale manufacturing methods.

SELECTION OF CITATIONS
SEARCH DETAIL
...