Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 111
Filter
12.
18.
Rev Esp Anestesiol Reanim (Engl Ed) ; 69(2): 102-104, 2022 02.
Article in English | MEDLINE | ID: mdl-35168918

ABSTRACT

INTRODUCTION: The development of a subcutaneous implantable cardioverter-defibrillator (S-ICD) combined with the typical patient comorbidities creates new challenges for anaesthesia. CLINICAL CASE: A young male, ASA II, was proposed for S-ICD placement, after recovery from a sudden CRP episode. We performed regional anaesthesia with a serratus plane block (SPB) and transversus thoracic muscle plane block (TTPB) with administration of Mepivacaine and Ropivacaine. S-ICD placement was achieved under regional anaesthesia. In the perioperative period, the patient remained hemodynamically stable, without any complications or pain. DISCUSSION: The implantation of the ICD occurs in fragile patients, with high anaesthetic risk. In this case, the association of SPB and TTPB was an effective anaesthetic/analgesic approach, has advantages when compared with other techniques and has potential use in other procedures.


Subject(s)
Anesthesia, Conduction , Nerve Block , Humans , Male , Muscle, Skeletal , Nerve Block/methods , Subcutaneous Tissue
19.
Rev. esp. anestesiol. reanim ; 69(2): 102-104, Feb 2022. ilus
Article in Spanish | IBECS | ID: ibc-206708

ABSTRACT

Introducción: El desarrollo de un desfibrilador-cardioversor implantable subcutáneo (DCI-S), combinado con las comorbilidades normales del paciente crea nuevos retos en anestesia. Caso clínico: Varón joven, ASA II, propuesto para implantación de DCI-S, tras recuperarse de un episodio de parada cardiaca súbita. Realizamos anestesia regional con bloqueo en el plano del músculo serrato y bloqueo del plano del músculo torácico transverso con administración de mepivacaína y ropivacaína. La implantación de DCI-S se logró bajo anestesia regional. En el periodo perioperatorio el paciente permaneció hemodinámicamente estable, sin complicaciones ni dolor. Discusión: La implantación de DCI se produce en pacientes frágiles, con alto riesgo anestésico. En este caso, la asociación de bloqueo en el plano del músculo serrato y bloqueo del plano del músculo torácico transverso fue una técnica anestésica/analgésica efectiva, con ventajas en comparación con otras técnicas, y uso potencial en otros procedimientos.(AU)


Introduction: The development of a subcutaneous implantable cardioverter-defibrillator (S-ICD) combined with the typical patient comorbidities creates new challenges for anesthesia. Clinical case: A young male, ASA II, was proposed for S-ICD placement, after recovery from a sudden CRP episode. We performed regional anesthesia with a serratus plane block and transversus thoracic muscle plane block with administration of mepivacaine and ropivacaine. S-ICD placement was achieved under regional anesthesia. In the perioperative period, the patient remained hemodynamically stable, without any complications or pain. Discussion: The implantation of the ICD occurs in fragile patients, with high anesthetic risk. In this case, the association of serratus plane block and transversus thoracic muscle plane block was an effective anesthetic/analgesic approach, has advantages when compared with other techniques and has potential use in other procedures.(AU)


Subject(s)
Humans , Male , Young Adult , Thorax , Muscles , Peripheral Nerves , Defibrillators, Implantable , Anesthesia, Conduction , Mepivacaine , Therapeutics , Anesthesiology , Cardiopulmonary Resuscitation
20.
Mar Pollut Bull ; 174: 113296, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34995889

ABSTRACT

This study aimed to assess the influence of treated wastewater disposal on Ria Formosa coastal lagoon (South Portugal), the largest national producer of bivalve mollusks. Water quality was evaluated at two areas under different wastewater loads and hydrodynamic conditions, using physico-chemical variables, bacterial indicators of contamination, chlorophyll-a concentration, phytoplankton abundance and composition. Samples were collected monthly, between October 2018 and September 2019. Minor influence of effluent discharge was detected at the eastern Olhão area, exposed to stronger hydrodynamics and higher wastewater load than the northwestern Faro area (ca. 2-4-fold total nitrogen and phosphorus). The lower load weakly flushed area showed a poorer water quality, up to 500 m from the discharge point, more marked during the spring-summer period. The intensity, persistence, and spatial extent of the wastewater footprint, lower for the highest-loading area, reflected the role of local hydrodynamic conditions, modulating the influence of wastewater discharge on lagoonal water quality.


Subject(s)
Wastewater , Water Quality , Environmental Monitoring , Hydrodynamics , Portugal , Taiwan
SELECTION OF CITATIONS
SEARCH DETAIL
...