Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
1.
J Invasive Cardiol ; 35(6): E281-E290, 2023 06.
Article in English | MEDLINE | ID: mdl-37220640

ABSTRACT

BACKGROUND: Despite the potential benefits of percutaneous procedures for the assessment and treatment of coronary artery disease, these interventions require the use of iodine contrast, which might lead to contrast-induced nephropathy (CIN) and increased risk of dialysis and major adverse cardiac events (MACE). AIMS: We sought to compare two different iodine contrasts (low vs. iso-osmolar) for the prevention of CIN among high-risk patients. METHODS: This is a single-center, randomized (1:1) trial comparing consecutive patients at high risk for CIN referred to percutaneous coronary diagnostic and/or therapeutic procedures with low (ioxaglate) vs. iso-osmolarity (iodixanol) iodine contrast. High risk was defined by the presence of at least one of the following conditions: age >70 years, diabetes mellitus, non-dialytic chronic kidney disease, chronic heart failure, cardiogenic shock, and acute coronary syndrome (ACS). The primary endpoint was the occurrence of CIN, defined as a >25% relative increase and/or >0.5 mg/dL absolute increase in creatinine (Cr) levels compared with baseline between the 2nd and 5th day after contrast media administration. RESULTS: A total of 2,268 patients were enrolled. Mean age was 67 years. Diabetes mellitus (53%), non-dialytic chronic kidney disease (31%), and ACS (39%) were highly prevalent. The mean volume of contrast media was 89 ml ± 48.6. CIN occurred in 15% of all patients, with no significant difference regarding the type of contrast used (iso = 15.2% vs. low = 15.1%, P>.99). Differences were not observed in specific subgroups such as diabetics, elderly, and ACS patients. At 30-day follow-up, 13 patients in the iso-osmolarity group and 11 in low-osmolarity group required dialysis (P =.8). There were 37 (3.3%) deaths in the iso-osmolarity cohort vs. 29 (2.6%) in the low-osmolarity group (P =.4). CONCLUSION: Among patients at high risk for CIN, the incidence of this complication was 15%, and independent of the use of low- or iso-osmolar contrast.


Subject(s)
Ioxaglic Acid , Kidney Diseases , Aged , Humans , Contrast Media/adverse effects , Coronary Angiography/adverse effects , Coronary Angiography/methods , Creatinine , Ioxaglic Acid/adverse effects , Kidney Diseases/chemically induced , Risk Factors , Triiodobenzoic Acids/adverse effects
2.
J Invasive Cardiol ; 35(3): E113-E121, 2023 03.
Article in English | MEDLINE | ID: mdl-36884359

ABSTRACT

OBJECTIVE: To enlighten preprocedural risk factors of mitral valve restenosis in a large, single-center cohort of patients submitted to percutaneous mitral balloon commissurotomy (PMBC) for the treatment of mitral stenosis (MS) secondary to rheumatic heart disease. METHODS: This is a database analysis of a single-center, high-volume tertiary institution involving all consecutive PMBC procedures performed in the mitral valve (MV). Restenosis was diagnosed when MV area was <1.5 cm² and/or loss of 50% or more of the immediate procedural result aligned with the return/worsened symptoms of heart failure. The primary endpoint was to determine the preprocedural independent predictors of restenosis after PMBC. RESULTS: Among a total of 1921 PMBC procedures, 1794 consecutive patients without previous intervention were treated between 1987 and 2010. Throughout 24 years of follow-up, MV restenosis was observed in 483 cases (26%). Mean age was 36 years and most (87%) were female. Median follow-up duration was 9.03 years (interquartile range, 0.33-23.38). Restenosis population, however, presented a significantly lower age at the procedure time as well as a higher Wilkins-Block score. At multivariate analysis, independent preprocedure predictors of restenosis were left atrium diameter (hazard risk [HR], 1.03; 95% confidence interval [CI], 1.02-1.05; P<.04), preprocedure maximum gradient (HR, 1.02; 95% CI, 1.00-1.03; P=.04), and higher Wilkins-Block score (>8) (HR, 1.38; 95% CI, 1.14-1.67; P<.01). CONCLUSIONS: At long-term follow-up, MV restenosis was observed in a quarter of the population undergoing PMBC. Preprocedure echocardiographic findings, including left atrial diameter, maximum MV gradient, and Wilkins-Block score were found to be the only independent predictors.


Subject(s)
Catheterization , Mitral Valve Stenosis , Humans , Female , Adult , Male , Catheterization/adverse effects , Follow-Up Studies , Echocardiography , Mitral Valve Stenosis/diagnosis , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/etiology , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Constriction, Pathologic , Recurrence , Treatment Outcome
3.
J Invasive Cardiol ; 35(5): E225-E233, 2023 05.
Article in English | MEDLINE | ID: mdl-36920890

ABSTRACT

BACKGROUND: Although first-generation drug-eluting stent (DES) devices have effectively achieved their main goal of reducing restenosis, their safety has been limited by suboptimal polymer biocompatibility, delayed stent endothelialization, and local drug toxicity, which ultimately prompted the development of new-generation DES options carrying biocompatible or even biodegradable polymers. AIMS: We sought to assess the vessel-healing pattern of the novel sirolimus-eluting Inspiron DES (Scitech Medical) using serial optical coherence tomography (OCT) and assuming the hypothesis that this thin-strut (75-µm), biodegradable-polymer DES promotes a faster healing, with very early strut coverage. METHODS: This is a prospective, multicenter, open-label, single-arm study enrolling 68 patients who underwent percutaneous coronary intervention guided by OCT. These patients were consecutively assigned into 3 groups. The first group had its OCT imaging follow-up performed at 3 months, the second group at 2 months, and the third group at 1 month. RESULTS: Mean age was 59.5 years, 70.6% were male, 41.2% had type 2 diabetes, and 29.4% presented with acute coronary syndrome. A total of 72 lesions were treated and 1.06 stents were implanted per patient. OCT assessment of the stents at 1, 2, and 3 months showed a strut coverage of 90.41%, 93.96%, and 97.21%, respectively (P=.04). CONCLUSION: The Inspiron DES showed an early strut healing pattern, with >90% of the struts covered by neointima within the first month and with almost all struts covered by the third month.


Subject(s)
Coronary Artery Disease , Diabetes Mellitus, Type 2 , Drug-Eluting Stents , Humans , Male , Middle Aged , Female , Coronary Artery Disease/therapy , Tomography, Optical Coherence/methods , Prospective Studies , Treatment Outcome , Prosthesis Design , Stents , Polymers
5.
Rev. port. cardiol ; 40(2): 71-76, Feb. 2021. graf, tab
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1177092

ABSTRACT

Resumo Introdução e objetivos: Stents Coated with the Biodegradable Polymer on their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions (Destiny Trial) é um estudo randomizado de não inferioridade que comparou o stent farmacológico eluído com Sirolimus Inspiron® (SES) ao controle o stent Biomatrix® Flex eluído com biolimus (BES). Relatórios dentro do primeiro ano mostraram resultados semelhantes para ambos os stents, em seguimento clínico, angiográfico e também em análise de tomografia de coerência ótica e ultrassom intracoronário. A presente análise tem como objetivo comparar o desempenho clínico desses dois stents farmacológicos com polímeros biodegradáveis após cinco anos do procedimento índice. Métodos: Foram randomizados 170 pacientes (194 lesões) em uma proporção de 2:1 para trata mento com SES ou BES, respetivamente. O desfecho primário para o presente estudo foi a taxa em cinco anos de eventos cardíacos adversos maiores combinados, definida como morte cardíaca, infarto do miocárdio ou revascularização da lesão-alvo. Resultados: Em cinco anos, o desfecho primário ocorreu em 12,5% e 17,9% para o grupo SES e BES, respectivamente (p=0,4). Não houve trombose de stent definitiva ou provável entre os pacientes tratados com o novo SES durante os cinco anos de seguimento e ausência de trombose de stent após o primeiro ano no grupo BES. Conclusões: O novo stent Inspiron® apresentou uma boa e semelhante performance clínica no seguimento em longo prazo, quando comparado com o controle o stent de última geração Biomatrix® Flex.


Subject(s)
Ultrasonography, Interventional , Tomography, Optical Coherence , Drug-Eluting Stents , Thrombosis
6.
Rev Port Cardiol (Engl Ed) ; 40(2): 71-76, 2021 Feb.
Article in English, Portuguese | MEDLINE | ID: mdl-33402278

ABSTRACT

INTRODUCTION AND OBJECTIVES: The Stents Coated With the Biodegradable Polymer on Their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions - DESTINY Trial is a non-inferiority randomized study that compared the Inspiron™ sirolimus-eluting stent (SES) with the control Biomatrix™ Flex biolimus-eluting stent (BES). Previous reports in the first year showed similar outcomes for both stents, in clinical, angiographic, optical coherence tomography, and intravascular ultrasound assessments. The present analysis aims to compare the clinical performance of these two biodegradable polymer drug-eluting stents five years after the index procedure. METHODS: A total of 170 patients (194 lesions) were randomized in a 2:1 ratio for treatment with SES or BES, respectively. The primary endpoint for the present study was the five-year rate of combined major adverse cardiac events, defined as cardiac death, myocardial infarction, or target lesion revascularization. RESULTS: At five years, the primary endpoint occurred in 12.5% and 17.9% of the SES and BES groups, respectively (p=0.4). There was no definite or probable stent thrombosis among patients treated with the novel SES stent during the five years of follow-up, and no stent thrombosis after the first year in the BES group. CONCLUSIONS: The novel Inspiron™ stent had similar good clinical performance in long-term follow-up when compared head-to-head with the control latest-generation Biomatrix™ Flex biolimus-eluting stent.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Absorbable Implants , Coronary Artery Disease/surgery , Humans , Polymers , Prosthesis Design , Treatment Outcome
7.
J Invasive Cardiol ; 32(9): 335-341, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32568096

ABSTRACT

OBJECTIVES: We sought to assess the effects of a high loading dose of rosuvastatin (40 mg) on acute inflammatory response after coronary stenting. METHODS: Patients with stable coronary disease without statin use (≥7 days) and undergoing elective percutaneous coronary intervention (PCI) in a native coronary artery were randomized to receive a loading dose of rosuvastatin (n = 64) or not (n = 61). Blood samples were obtained before statin intake (time point A), 3 hours after medication (time point B), and 3 hours after PCI (time point C). The primary goal was the comparison in the variation of the serum inflammatory markers and their gene expression at the different time points between the two groups. RESULTS: Baseline clinical, angiographic, and procedural characteristics did not significantly differ between the groups, except for the more frequent use of postdilation in the control group (73.4% vs 90.2%; P=.02). Patients pretreated with statin showed a reduction in the serum levels of interleukin (IL)-1ß (Δ = -0.491 pg/mL; Pinteraction<.001), IL-6 (Δ = -0.209 pg/mL; Pinteraction<.001), and plasminogen activator inhibitor 1 (Δ = -1.573 pg/mL; Pinteraction<.001) as well as in their genetic expression, which was not observed in the control group. Regarding high-sensitivity c-reactive protein, there was no significant variation in its value from time point A to C in patients pretreated with statin (P=.58) while it significantly increased in the control group (P=.04). CONCLUSIONS: Among patients with stable coronary artery disease undergoing PCI with stents, pretreatment with high dose of rosuvastatin resulted in significant reduction in the serum levels of important inflammatory markers and their genetic expression.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Hydroxymethylglutaryl-CoA Reductase Inhibitors , Inflammation , Percutaneous Coronary Intervention , Rosuvastatin Calcium/administration & dosage , C-Reactive Protein/analysis , Coronary Artery Disease/diagnosis , Coronary Artery Disease/drug therapy , Coronary Artery Disease/surgery , Humans , Inflammation/blood , Interleukin-1beta/blood , Percutaneous Coronary Intervention/adverse effects , Plasminogen Activator Inhibitor 1/blood
8.
J Invasive Cardiol ; 32(6): 211-217, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32269178

ABSTRACT

OBJECTIVES: Percutaneous mitral balloon commissurotomy (PMBC) remains the preferred treatment for patients with severe symptomatic rheumatic mitral stenosis (MS) and suitable anatomy. The objective of this study was to propose a new score for the prediction of immediate and late success. METHODS: This is a single-center, retrospective analysis of all 1582 patients with severe mitral stenosis who underwent PMBC from August 1987 to July 2010. The composite outcome was cardiovascular death, new PMBC, or mitral valve repair surgery up to 24 years of follow-up. RESULTS: Mean patient age was 36.8 ± 12.9 years, most (86.4%) were female, and Wilkins score was between 9-11 in 49.1% of patients. In the multivariate analysis, the predictors of immediate success were age (odds ratio [OR], 0.98; 95% confidence interval [CI], 0.96-0.99; P=.01), left atrium size (OR, 0.96; 95% CI, 0.93-0.99; P=.01), mean preprocedure mitral gradient (OR, 0.93; 95% CI, 0.89-0.96; P<.001), intermediate Wilkins score 9-11 (OR, 0.62; 95% CI, 0.40-0.94; P=.02), and high Wilkins score ≥12 (OR, 0.35; 95% CI, 0.16-0.76; P<.01). For prediction of late events, age (hazard ratio [HR], 0.98; 95% CI, 0.97-0.98; P<.001), New York Heart Association class III-IV (HR, 1.50; 95% CI, 1.18-1.92; P<.001), left atrium size (HR, 1.02; 95% CI, 1.02-0.04; P<.01), and high Wilkins score ≥12 (HR, 2.02; 95% CI, 1.30-3.15; P<.01) were significant. Two nomograms were developed using significant predictors from the model. CONCLUSIONS: In this large population, not only the Wilkins score, but also clinical and hemodynamic features, seem to be relevant in predicting immediate and late success for patients with rheumatic MS who underwent PMBC.


Subject(s)
Cardiac Surgical Procedures , Mitral Valve Stenosis , Adult , Female , Follow-Up Studies , Humans , Male , Middle Aged , Mitral Valve Stenosis/diagnosis , Mitral Valve Stenosis/surgery , Prognosis , Retrospective Studies , Treatment Outcome , Young Adult
9.
Catheter. cardiovasc. interv ; 93(1): 1-7, Jan. 2019. gráfico, tabela
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024591

ABSTRACT

BACKGROUND: There is still limited data on the very long term clinical outcomes after ABSORB BRS in daily practice. We sought to evaluate the 3 year-performance of the Absorb bioresorbable vascular scaffolds for the treatment of low/moderate complexity patients enrolled in the ABSORB EXTEND trial. METHODS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA). To determine the independent predictors of MACE, a multivariable logistic regression model was built using a stepwise (forward/backward) procedure. RESULTS: Average population age was 61 years and 26.5% had diabetes. Most patients had single target lesion (92.4%). Adequate scaffold deployment (PSP) was achieved in 14.2% of the cases. At three years, the composite endpoints of MACE and ischemia-driven target vessel failure were 9.2% and 10.6%, respectively. The cumulative rate of ARC definite/probable thrombosis was 2.2%, with 1.2% of the cases occurring after the 1st year. Independent predictors of MACE were hypertension and the need for "bail out" stent. CONCLUSION: At three-year follow-up, the use of ABSORB in low/moderate complex PCI was associated with low and acceptable rates of major adverse clinical events, despite the infrequent use of the recommended contemporary scaffold deployment technique. However, scaffold thrombosis rate was higher than reported with current generation of metallic DES. (AU)


Subject(s)
Humans , Thrombosis , Percutaneous Coronary Intervention , Everolimus
10.
Catheter Cardiovasc Interv ; 93(1): E1-E7, 2019 01 01.
Article in English | MEDLINE | ID: mdl-30286520

ABSTRACT

BACKGROUND: There is still limited data on the very long term clinical outcomes after ABSORB BRS in daily practice. We sought to evaluate the 3 year-performance of the Absorb bioresorbable vascular scaffolds for the treatment of low/moderate complexity patients enrolled in the ABSORB EXTEND trial. METHODS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA). To determine the independent predictors of MACE, a multivariable logistic regression model was built using a stepwise (forward/backward) procedure. RESULTS: Average population age was 61 years and 26.5% had diabetes. Most patients had single target lesion (92.4%). Adequate scaffold deployment (PSP) was achieved in 14.2% of the cases. At three years, the composite endpoints of MACE and ischemia-driven target vessel failure were 9.2% and 10.6%, respectively. The cumulative rate of ARC definite/probable thrombosis was 2.2%, with 1.2% of the cases occurring after the 1st year. Independent predictors of MACE were hypertension and the need for "bail out" stent. CONCLUSION: At three-year follow-up, the use of ABSORB in low/moderate complex PCI was associated with low and acceptable rates of major adverse clinical events, despite the infrequent use of the recommended contemporary scaffold deployment technique. However, scaffold thrombosis rate was higher than reported with current generation of metallic DES. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).


Subject(s)
Absorbable Implants , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Artery Disease/therapy , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Aged , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/epidemiology , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prospective Studies , Prosthesis Design , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
12.
JACC cardiovasc. interv ; 11(19): 1945-1952, Oct. 2018. tab, graf
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1222417

ABSTRACT

OBJECTIVES: The aim of this study was to assess very long term outcomes after successful percutaneous balloon mitral valvuloplasty (PBMV).BACKGROUND: PBMV remains the preferred treatment for patients with severe symptomatic rheumatic mitral stenosis and suitable anatomy.METHODS: All consecutive patients who underwent successful PBMV between 1987 and 2010 were included. The primary endpoint was the composite of all-cause mortality, need for mitral surgery, or repeat PBMV up to 23 years.RESULTS: Among all 1,582 consecutive patients undergoing PBMV, acute success was achieved in 90.9% (n»1,438).Independent predictors of acute success included left atrial size (odds ratio: 0.96; 95% confidence interval [CI]: 0.93 to0.99; p»0.045), Wilkins score#8 (odds ratio: 1.66; 95% CI: 0.48 to 0.93; p»0.02) and age (odds ratio: 0.97; 95% CI:0.96 to 0.99; p»0.006). Very long-term follow-up (median 8.3 years, mean 15.6 years) was obtained in 79.1% of successful cases. The incidence of the primary endpoint was 19.1% (95% CI: 17.0% to 21.1%). The rates of overall lmortality, need for mitral valve surgery, or repeat PBMV were 0.6% (95% CI: 0.3% to 1.2%), 8.3% (95% CI: 7.0% to9.9%), and 10.0% (95% CI: 8.5% to 11.7%), respectively. On multivariate analysis, New York Heart Association functional class III or IV (hazard ratio: 1.62; 95% CI: 1.26 to 2.09; p<0.001), higher age (hazard ratio: 0.97; 95% CI: 0.96 to0.98; p»0.028), and mitral valve area#1.75 cm2after the procedure (hazard ratio: 1.67; 95% CI: 1.28 to 2.11;p»0.028) were independent predictors of the primary endpoint. CONCLUSIONS: In very long term follow-up, more than 75% of patients exhibited sustained results. Prediction of late favorable results is multifactorial and strongly determined by age, previous symptoms and post-procedural mitral valve area.(J Am Coll Cardiol Intv 2018;11:1945­52) © 2018 by the American College of Cardiology Foundation.


Subject(s)
Balloon Valvuloplasty , Mitral Valve , Mitral Valve Stenosis
13.
JACC Cardiovasc Interv ; 11(19): 1945-1952, 2018 10 08.
Article in English | MEDLINE | ID: mdl-30077684

ABSTRACT

OBJECTIVES: The aim of this study was to assess very long term outcomes after successful percutaneous balloon mitral valvuloplasty (PBMV). BACKGROUND: PBMV remains the preferred treatment for patients with severe symptomatic rheumatic mitral stenosis and suitable anatomy. METHODS: All consecutive patients who underwent successful PBMV between 1987 and 2010 were included. The primary endpoint was the composite of all-cause mortality, need for mitral surgery, or repeat PBMV up to 23 years. RESULTS: Among all 1,582 consecutive patients undergoing PBMV, acute success was achieved in 90.9% (n = 1,438). Independent predictors of acute success included left atrial size (odds ratio: 0.96; 95% confidence interval [CI]: 0.93 to 0.99; p = 0.045), Wilkins score ≤8 (odds ratio: 1.66; 95% CI: 0.48 to 0.93; p = 0.02) and age (odds ratio: 0.97; 95% CI: 0.96 to 0.99; p = 0.006). Very long term follow-up (median 8.3 years, mean 15.6 years) was obtained in 79.1% of successful cases. The incidence of the primary endpoint was 19.1% (95% CI: 17.0% to 21.1%). The rates of overall mortality, need for mitral valve surgery, or repeat PBMV were 0.6% (95% CI: 0.3% to 1.2%), 8.3% (95% CI: 7.0% to 9.9%), and 10.0% (95% CI: 8.5% to 11.7%), respectively. On multivariate analysis, New York Heart Association functional class III or IV (hazard ratio: 1.62; 95% CI: 1.26 to 2.09; p < 0.001), higher age (hazard ratio: 0.97; 95% CI: 0.96 to 0.98; p = 0.028), and mitral valve area ≤1.75 cm2 after the procedure (hazard ratio: 1.67; 95% CI: 1.28 to 2.11; p = 0.028) were independent predictors of the primary endpoint. CONCLUSIONS: In very long term follow-up, more than 75% of patients exhibited sustained results. Prediction of late favorable results is multifactorial and strongly determined by age, previous symptoms and post-procedural mitral valve area.


Subject(s)
Balloon Valvuloplasty , Mitral Valve Stenosis/therapy , Mitral Valve/physiopathology , Rheumatic Heart Disease/therapy , Adult , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/mortality , Female , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/mortality , Mitral Valve Stenosis/physiopathology , Recovery of Function , Retrospective Studies , Rheumatic Heart Disease/diagnostic imaging , Rheumatic Heart Disease/mortality , Rheumatic Heart Disease/physiopathology , Risk Factors , Time Factors , Treatment Outcome , Young Adult
14.
Methodist Debakey Cardiovasc J ; 14(1): 42-49, 2018.
Article in English | MEDLINE | ID: mdl-29623171

ABSTRACT

Bioresorbable scaffolds (BRS) were developed as an alternative to drug-eluting stents (DES) to facilitate vessel restoration and reduce the risk of future adverse events. However, recent meta-analyses and "real-world" registries have raised some concern about the safety of this novel technology, especially due to an increased risk of thrombosis within the first weeks of scaffold implantation. These devices appear to be less forgiving to poor implantation strategies when compared to contemporary DES. Moreover, problems with the first generation of these devices-bulky struts and high crossing prolife, prolonged resorption time, lack of x-ray visibility, and limited tolerance to postdilation-have restricted their clinical application and negatively impacted their short- to mid-term safety performance. However, the potential for long-term improvements has encouraged further research into strategies to overcome these limitations, and potentially safer next-generation devices are already undergoing in-human clinical evaluations. Based on the current literature and our center's experience with these devices, this review discusses various approaches to optimize BRS implantation, drawbacks related to current-generation BRS, and potentially advantageous features of three next-generation scaffold systems.


Subject(s)
Absorbable Implants , Coronary Artery Disease/therapy , Percutaneous Coronary Intervention/instrumentation , Prosthesis Design , Absorbable Implants/trends , Animals , Clinical Decision-Making , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Diffusion of Innovation , Forecasting , Humans , Patient Selection , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/trends , Prosthesis Design/trends , Prosthesis Failure , Risk Factors , Treatment Outcome
15.
Catheter Cardiovasc Interv ; 92(6): E368-E374, 2018 11 15.
Article in English | MEDLINE | ID: mdl-29521477

ABSTRACT

INTRODUCTION: Bioresorbable coronary scaffolds (BRS) have been developed to increase the late safety of coronary angioplasty by providing transitory coronary support and then being fully incorporated to the vessel wall. In the present trial, we sought to evaluate the performance and changes over time in the DESolve™ novolimus-eluting BRS using serial intravascular ultrasound (IVUS) in patients submitted to percutaneous coronary interventions. METHODS: Single-center, prospective, non-randomized study involving 17 consecutive patients submitted to implantation of the DESolve™ scaffold and serial evaluated with IVUS at different time points (post procedure, 6 and 18 months). Primary endpoint included the variation in lumen, scaffold, and vessel diameter and area along the months. RESULTS: Angiographic success was achieved in all cases. Scaffold area and volume on IVUS were significantly greater at 6 months than at baseline (6.41 ± 1.35 mm2 vs. 7.35 ± 1.53 mm2 , P < 0.002; and 101.19 ± 20.9 mm3 vs. 118.51 ± 26.6 mm3 , P = 0.001). Late lumen loss was 0.22 ± 0.30 mm at 6 months and 0.33 ± 0.44 mm at 18 months. No major adverse cardiac events occurred. At late follow-up (18 months) the scaffold was not visualized by IVUS; therefore the evaluation was restricted to lumen and vessel at that time point. CONCLUSIONS: IVUS serial evaluation of the novel DESolve BRS showed an increase in the device dimensions between baseline and 6 months, with concomitant enlargement of lumen dimensions and effective suppression of neointimal proliferation. At 18 months, no footprint of the scaffold was detected and the initial lumen enlargement was sustained.


Subject(s)
Absorbable Implants , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Macrolides/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Ultrasonography, Interventional , Aged , Cardiovascular Agents/adverse effects , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Female , Humans , Macrolides/adverse effects , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Prospective Studies , Time Factors , Treatment Outcome
17.
Catheter Cardiovasc Interv ; 91(7): 1202-1209, 2018 06.
Article in English | MEDLINE | ID: mdl-29024452

ABSTRACT

BACKGROUND: Preclinical data showed that overlapping (OVP) scaffolds might result in delayed healing and strut coverage compared to nonOVP scaffold segments. Furthermore, OVP in patients could result in increased periprocedure myocardial infarction (MI) rate secondary to side branch occlusion; however, little is known whether this may have an impact on long-term clinical outcomes. METHODS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. In this study, we compared the immediate and 2-year clinical outcomes of patients with OVP scaffolds (n = 115) to those of patients with nonOVP scaffolds (n = 697). The primary objective was the comparison of major adverse cardiac event (MACE) (cardiac death, MI and ischemic-driven target lesion revascularization [TLR]) and scaffold thrombosis (ST) rates up to 2 years. RESULTS: Baseline clinical and angiographic characteristics were comparable between cohorts except for longer lesions in the OVP patients as expected (16.7 ± 7.3 vs. 11.6 ± 4.4 mm, P < 0.0001), higher lesion complexity (B2) and numerically smaller vessel size. In-hospital, there was a marked increase in MACE in the OVP cohort (7.0 vs. 0.9%, P = 0.002), exclusively driven by a higher rate of periprocedure MI (7.0 vs. 0.9%, P = 0.002). Long-term MACE did not significantly differ between groups (10.4% in the OVP cohort vs. 6.6% in the no-OVP group, P = 0.1) with comparable rates of cardiac death (0.9 vs. 1.2%, P = 1.0) and ischemia-driven TLR (1.7 vs. 2.5%, P = 1.0). Cumulative incidence of MI was higher in the OVP cohort (7.8 vs. 3.0%, P = 0.02). Of note, the rate of MI between hospital discharge and 2-year follow-up was lower in the OVP cohort (0.8 vs. 2.1%, P = 0.04). Cumulative incidence of definite/probable ST was relatively low and comparable between groups (1.8 vs. 1.5%, P = 0.7). CONCLUSIONS: In this low-to-moderate complex population treated with the ABSORB scaffold the OVP group showed a higher incidence of periprocedure MI with no immediate or long-term increase in cardiac death, TLR or ST.


Subject(s)
Absorbable Implants , Coronary Artery Disease/surgery , Percutaneous Coronary Intervention/instrumentation , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Female , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prospective Studies , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
19.
J Invasive Cardiol ; 29(6): 195-201, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28570234

ABSTRACT

OBJECTIVES: The present study examined the association between Multicenter CTO Registry in Japan (J-CTO) score in predicting failure of percutaneous coronary intervention (PCI) correlating with the estimated duration of chronic total occlusion (CTO). BACKGROUND: The J-CTO score does not incorporate estimated duration of the occlusion. METHODS: This was an observational retrospective study that involved all consecutive procedures performed at a single tertiary-care cardiology center between January 2009 and December 2014. RESULTS: A total of 174 patients, median age 59.5 years (interquartile range [IQR], 53-65 years), undergoing CTO-PCI were included. The median estimated occlusion duration was 7.5 months (IQR, 4.0-12.0 months). The lesions were classified as easy (score = 0), intermediate (score = 1), difficult (score = 2), and very difficult (score ≥3) in 51.1%, 33.9%, 9.2%, and 5.7% of the patients, respectively. Failure rate significantly increased with higher J-CTO score (7.9%, 20.3%, 50.0%, and 70.0% in groups with J-CTO scores of 0, 1, 2, and ≥3, respectively; P<.001). There was no significant difference in success rate according to estimated duration of occlusion (P=.63). Indeed, J-CTO score predicted failure of CTO-PCI independently of the estimated occlusion duration (P=.24). Areas under receiver-operating characteristic curves were computed and it was observed that for each occlusion time period, the discriminatory capacity of the J-CTO score in predicting CTO-PCI failure was good, with a C-statistic >0.70. CONCLUSION: The estimated duration of occlusion had no influence on the J-CTO score performance in predicting failure of PCI in CTO lesions. The probability of failure was mainly determined by grade of lesion complexity.


Subject(s)
Coronary Occlusion/surgery , Percutaneous Coronary Intervention/adverse effects , Postoperative Complications/diagnosis , Registries , Risk Assessment , Aged , Chronic Disease , Coronary Angiography , Coronary Occlusion/diagnosis , Female , Follow-Up Studies , Humans , Japan/epidemiology , Male , Middle Aged , Postoperative Complications/epidemiology , Predictive Value of Tests , ROC Curve , Retrospective Studies , Risk Factors , Severity of Illness Index , Time Factors , Treatment Failure
20.
J Invasive Cardiol ; 29(3): 76-81, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28255102

ABSTRACT

BACKGROUND: Previous studies have suggested a benefit of cilostazol in addition to standard dual-antiplatelet therapy (DAPT), reducing in-stent late luminal loss and restenosis after percutaneous coronary intervention (PCI) with bare-metal and drug-eluting stent (DES) implantation. However, there is a paucity of intravascular ultrasound (IVUS) assessment of neointimal tissue hyperplasia (NIH) after triple-antiplatelet therapy (TAPT), especially in diabetic patients treated with DES. METHODS: This prospective, placebo-controlled trial was conducted in diabetic patients randomized (1:1) to receive either standard DAPT (aspirin and clopidogrel) vs TAPT with cilostazol for a minimum of 12 months after PCI with Endeavor zotarolimus-eluting stent (E-ZES). The primary endpoint was the 9-month comparison of percentage of NIH in both groups. Additionally, we compared in-stent late lumen loss, binary restenosis, major adverse cardiac event (MACE; cardiac death, non-fatal myocardial infarction, and restenosis) rates, and the incidence of vascular/bleeding complications. RESULTS: In total, 133 diabetic patients were enrolled (cilostazol cohort = 65 patients) with 56.4% male and mean age of 60.8 years. Overall, the two cohorts were comparable in terms of baseline clinical and angiographic characteristics, except for the reference vessel diameter, which was smaller among patients randomized to cilostazol (2.48 ± 0.46 mm vs 2.69 ± 0.48 mm; P=.01). At 9 months, there was a non-significant trend toward less percentage of NIH obstruction in the TAPT cohort (33.2 ± 8.29% vs 35.1 ± 8.45%; P=.07). However, this finding did not impact angiographic late-lumen loss (0.60 ± 0.46 mm cilostazol group vs 0.64 ± 0.48 mm control group; P=.30) and binary restenosis (9.8% vs 6.8%; P=.99). MACE rate also did not significantly differ between the cohorts (13.8% cilostazol group vs 8.8% control group; P=.81). Of note, the addition of a third antiplatelet agent did not increase vascular and bleeding complications. CONCLUSION: In diabetic patients treated with E-ZES, TAPT with cilostazol did not add any significant benefit in terms of NIH suppression or MACE reduction.


Subject(s)
Aspirin , Coronary Artery Disease , Coronary Restenosis/prevention & control , Diabetes Mellitus/epidemiology , Drug Therapy, Combination/methods , Neointima/prevention & control , Percutaneous Coronary Intervention , Tetrazoles , Ticlopidine/analogs & derivatives , Aspirin/administration & dosage , Aspirin/adverse effects , Cilostazol , Clopidogrel , Comorbidity , Coronary Angiography/methods , Coronary Artery Disease/blood , Coronary Artery Disease/diagnosis , Coronary Artery Disease/epidemiology , Coronary Artery Disease/therapy , Coronary Restenosis/diagnosis , Coronary Restenosis/etiology , Drug-Eluting Stents/adverse effects , Female , Hemorrhage/chemically induced , Hemorrhage/prevention & control , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Platelet Aggregation Inhibitors/administration & dosage , Platelet Aggregation Inhibitors/adverse effects , Sirolimus/analogs & derivatives , Sirolimus/therapeutic use , Tetrazoles/administration & dosage , Tetrazoles/adverse effects , Ticlopidine/administration & dosage , Ticlopidine/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL