1.
Forensic Sci Int Genet ; 35: 156-163, 2018 07.
Article in English | MEDLINE | ID: mdl-29783171

ABSTRACT

One of the main goals of the Spanish and Portuguese-Speaking Group of the International Society for Forensic Genetics (GHEP-ISFG) is to promote and contribute to the development and dissemination of scientific knowledge in the field of forensic genetics. Due to this fact, GHEP-ISFG holds different working commissions that are set up to develop activities in scientific aspects of general interest. One of them, the Mixture Commission of GHEP-ISFG, has organized annually, since 2009, a collaborative exercise on analysis and interpretation of autosomal short tandem repeat (STR) mixture profiles. Until now, six exercises have been organized. At the present edition (GHEP-MIX06), with 25 participant laboratories, the exercise main aim was to assess mixture profiles results by issuing a report, from the proposal of a complex mock case. One of the conclusions obtained from this exercise is the increasing tendency of participating laboratories to validate DNA mixture profiles analysis following international recommendations. However, the results have shown some differences among them regarding the edition and also the interpretation of mixture profiles. Besides, although the last revision of ISO/IEC 17025:2017 gives indications of how results should be reported, not all laboratories strictly follow their recommendations. Regarding the statistical aspect, all those laboratories that have performed statistical evaluation of the data have employed the likelihood ratio (LR) as a parameter to evaluate the statistical compatibility. However, LR values obtained show a wide range of variation. This fact could not be attributed to the software employed, since the vast majority of laboratories that performed LR calculation employed the same software (LRmixStudio). Thus, the final allelic composition of the edited mixture profile and the parameters employed in the software could explain this data dispersion. This highlights the need, for each laboratory, to define through internal validations its criteria for editing and interpreting mixtures, and to continuous train in software handling.


Subject(s)
DNA Fingerprinting/standards , Forensic Genetics/standards , Laboratories/statistics & numerical data , Microsatellite Repeats , Societies, Scientific , Humans , Likelihood Functions , Research Report/standards , Software
2.
Forensic Sci Int Genet ; 32: 18-25, 2018 01.
Article in English | MEDLINE | ID: mdl-29024923

ABSTRACT

A collaborative effort was carried out by the Spanish and Portuguese Speaking Working Group of the International Society for Forensic Genetics (GHEP-ISFG) to promote knowledge exchange between associate laboratories interested in the implementation of indel-based methodologies and build allele frequency databases of 38 indels for forensic applications. These databases include populations from different countries that are relevant for identification and kinship investigations undertaken by the participating laboratories. Before compiling population data, participants were asked to type the 38 indels in blind samples from annual GHEP-ISFG proficiency tests, using an amplification protocol previously described. Only laboratories that reported correct results contributed with population data to this study. A total of 5839 samples were genotyped from 45 different populations from Africa, America, East Asia, Europe and Middle East. Population differentiation analysis showed significant differences between most populations studied from Africa and America, as well as between two Asian populations from China and East Timor. Low FST values were detected among most European populations. Overall diversities and parameters of forensic efficiency were high in populations from all continents.


Subject(s)
Genetics, Population , INDEL Mutation , Polymorphism, Single Nucleotide , Racial Groups/genetics , DNA Fingerprinting , Databases, Nucleic Acid , Ethnicity/genetics , Gene Frequency , Genotype , Humans , Laboratories/statistics & numerical data , Microsatellite Repeats
3.
Forensic Sci Int Genet ; 25: 63-72, 2016 11.
Article in English | MEDLINE | ID: mdl-27500650

ABSTRACT

Since 1992, the Spanish and Portuguese-Speaking Working Group of the ISFG (GHEP-ISFG) has been organizing annual Intercomparison Exercises (IEs) coordinated by the Quality Service at the National Institute of Toxicology and Forensic Sciences (INTCF) from Madrid, aiming to provide proficiency tests for forensic DNA laboratories. Each annual exercise comprises a Basic (recently accredited under ISO/IEC 17043: 2010) and an Advanced Level, both including a kinship and a forensic module. Here, we show the results for both autosomal and sex-chromosomal STRs, and for mitochondrial DNA (mtDNA) in two samples included in the forensic modules, namely a mixture 2:1 (v/v) saliva/blood (M4) and a mixture 4:1 (v/v) saliva/semen (M8) out of the five items provided in the 2014 GHEP-ISFG IE. Discrepancies, other than typos or nomenclature errors (over the total allele calls), represented 6.5% (M4) and 4.7% (M8) for autosomal STRs, 15.4% (M4) and 7.8% (M8) for X-STRs, and 1.2% (M4) and 0.0% (M8) for Y-STRs. Drop-out and drop-in alleles were the main cause of errors, with laboratories using different criteria regarding inclusion of minor peaks and stutter bands. Commonly used commercial kits yielded different results for a micro-variant detected at locus D12S391. In addition, the analysis of electropherograms revealed that the proportions of the contributors detected in the mixtures varied among the participants. In regards to mtDNA analysis, besides important discrepancies in reporting heteroplasmies, there was no agreement for the results of sample M4. Thus, while some laboratories documented a single control region haplotype, a few reported unexpected profiles (suggesting contamination problems). For M8, most laboratories detected only the haplotype corresponding to the saliva. Although the GHEP-ISFG has already a large experience in IEs, the present multi-centric study revealed challenges that still exist related to DNA mixtures interpretation. Overall, the results emphasize the need for further research and training actions in order to improve the analysis of mixtures among the forensic practitioners.


Subject(s)
Chromosomes, Human, X , Chromosomes, Human, Y , DNA Fingerprinting , DNA, Mitochondrial/genetics , Laboratories/standards , Microsatellite Repeats , Amelogenin/genetics , Blood Chemical Analysis , Female , Forensic Genetics , Genetic Markers , Haplotypes , Humans , Male , Saliva/chemistry , Semen/chemistry