Results 1 - 20 de 30
Filter
1.
Mol Aspects Med ; 97: 101275, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38772082

ABSTRACT

Diagnostic tests were heralded as crucial during the Coronavirus disease (COVID-19) pandemic with most of the key methods using bioanalytical approaches that detected larger molecules (RNA, protein antigens or antibodies) rather than conventional clinical biochemical techniques. Nucleic Acid Amplification Tests (NAATs), like the Polymerase Chain Reaction (PCR), and other molecular methods, like sequencing (that often work in combination with NAATs), were essential to the diagnosis and management during COVID-19. This was exemplified both early in the pandemic but also later on, following the emergence of new genetic SARS-CoV-2 variants. The 100 day mission to respond to future pandemic threats highlights the need for effective diagnostics, therapeutics and vaccines. Of the three, diagnostics represents the first opportunity to manage infectious diseases while also being the most poorly supported in terms of the infrastructure needed to demonstrate effectiveness. Where performance targets exist, they are not well served by consensus on how to demonstrate they are being met; this includes analytical factors such as limit of detection (LOD) false positive results as well as how to approach clinical evaluation. The selection of gold standards or use of epidemiological factors such as predictive value, reference ranges or clinical thresholds are seldom correctly considered. The attention placed on molecular diagnostic tests during COVID-19 illustrates important considerations and assumptions on the use of these methods for infectious disease diagnosis and beyond. In this manuscript, we discuss state-of-the-art approaches to diagnostic evaluation and explore how they may be better tailored to diagnostic techniques like NAATs to maximise the impact of these highly versatile bioanalytical tools, both generally and during future outbreaks.


Subject(s)
COVID-19 , Nucleic Acid Amplification Techniques , SARS-CoV-2 , Humans , Nucleic Acid Amplification Techniques/methods , COVID-19/diagnosis , COVID-19/virology , COVID-19/epidemiology , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Pandemics , COVID-19 Nucleic Acid Testing/methods , Sensitivity and Specificity , COVID-19 Testing/methods , RNA, Viral/genetics , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Communicable Diseases/diagnosis
2.
Sci Rep ; 13(1): 13206, 2023 08 14.
Article in English | MEDLINE | ID: mdl-37580353

ABSTRACT

The COVID-19 pandemic illustrated the important role of diagnostic tests, including lateral flow tests (LFTs), in identifying patients and their contacts to slow the spread of infections. INSTAND performed external quality assessments (EQA) for SARS-CoV-2 antigen detection with lyophilized and chemically inactivated cell culture supernatant of SARS-CoV-2 infected Vero cells. A pre-study demonstrated the suitability of the material. Participants reported qualitative and/or quantitative antigen results using either LFTs or automated immunoassays for five EQA samples per survey. 711 data sets were reported for LFT detection in three surveys in 2021. This evaluation focused on the analytical sensitivity of different LFTs and automated immunoassays. The inter-laboratory results showed at least 94% correct results for non-variant of concern (VOC) SARS-CoV-2 antigen detection for viral loads of ≥ 4.75 × 106 copies/mL and SARS-CoV-2 negative samples. Up to 85% had success for a non-VOC viral load of ~ 1.60 × 106 copies/mL. A viral load of ~ 1.42 × 107 copies/mL of the Delta VOC was reported positive in > 96% of results. A high specificity was found with almost 100% negative SARS-CoV-2 antigen results for HCoV 229E and HCoV NL63 positive samples. Quantitative results correlated with increasing SARS-CoV-2 viral load but showed a broad scatter. This study shows promising SARS-CoV-2 antigen test performance of the participating laboratories, but further investigations with the now predominant Omicron VOC are needed.


Subject(s)
COVID-19 , SARS-CoV-2 , Chlorocebus aethiops , Animals , Humans , Pandemics , Vero Cells , COVID-19/diagnosis , COVID-19/epidemiology , Immunologic Tests , Sensitivity and Specificity
3.
Clin Chem ; 68(8): 1075-1083, 2022 07 27.
Article in English | MEDLINE | ID: mdl-35699503

ABSTRACT

BACKGROUND: Newborn screening (NBS) laboratories in the United Kingdom adhere to common protocols based on single analyte cutoff values (COVs); therefore, interlaboratory harmonization is of paramount importance. Interlaboratory variation for screening analytes in UK NBS laboratories ranges from 17% to 59%. While using common stable isotope internal standards has been shown to significantly reduce interlaboratory variation, instrument set-up, sample extraction, and calibration approach are also key factors. METHODS: Dried blood spot (DBS) extraction processes, instrument set-up, mobile-phase composition, sample introduction technique, and calibration approach of flow injection analysis-tandem mass spectrometry (FIA-MS/MS) methods were optimized. Inter- and intralaboratory variation of methionine, leucine, phenylalanine, tyrosine, isovaleryl-carnitine, glutaryl-carnitine, octanoyl-carnitine, and decanoyl-carnitine were determined pre- and postoptimization, using 3 different calibration approaches. RESULTS: Optimal recovery of analytes from DBS was achieved with a 35-min extraction time and 80% methanol (150 µL). Optimized methodology decreased the mean intralaboratory percentage relative SD (%RSD) for the 8 analytes from 20.7% (range 4.1-46.0) to 5.4% (range 3.0-8.5). The alternative calibration approach reduced the mean interlaboratory %RSD for all analytes from 16.8% (range 4.1-25.0) to 7.1% (range 4.1-11.0). Nuclear magnetic resonance analysis of the calibration material highlighted the need for standardization. The purities of isovaleryl-carnitine and glutaryl-carnitine were 85.13% and 69.94% respectively, below the manufacturer's stated values of ≥98%. CONCLUSIONS: For NBS programs provided by multiple laboratories using single analyte COVs, harmonization and standardization of results can be achieved by optimizing legacy FIA-MS/MS methods, adopting a common analytical protocol, and using standardized calibration material rather than internal calibration.


Subject(s)
Flow Injection Analysis , Tandem Mass Spectrometry , Calibration , Carnitine , Flow Injection Analysis/methods , Humans , Infant, Newborn , Neonatal Screening/methods , Reference Standards , Tandem Mass Spectrometry/methods
4.
Anal Chem ; 94(14): 5566-5574, 2022 04 12.
Article in English | MEDLINE | ID: mdl-35357151

ABSTRACT

The use of standardized components and processes in engineering underpins the design-build-test model, and the engineering of biological systems is no different. Substantial efforts to standardize both the components and the methods to validate the engineered biological systems is ongoing. This study has developed a panel of control materials encoding the commonly used reporter genes GFP and RFP as DNA or RNA molecules. Each panel contained up to six samples with increasingly small copy number differences between the two reporter genes that ranged from 1- to 2-fold differences. These copy number differences represent the magnitude of changes that may need to be measured to validate an engineered system. Using digital PCR (dPCR), we demonstrated that it is possible to quantify changes in both gene and gene transcript numbers both within and between samples down to 1.05-fold. We corroborated these findings using a simple gene circuit within a bacterial model to demonstrate that dPCR was able to precisely identify small changes in gene expression of two transcripts in response to promoter stimulation. Finally, we used our findings to highlight sources of error that can contributed to the measurement uncertainty in the measurement of small ratios in biological systems. Together, the development of a panel of control materials and validation of a high accuracy method for the measurement of small changes in gene expression, this study can contribute to the engineering biology "toolkit" of methods and materials to support the current standardization efforts.


Subject(s)
Polymerase Chain Reaction , Genes, Reporter , Polymerase Chain Reaction/methods , Promoter Regions, Genetic
5.
PLoS One ; 17(1): e0262656, 2022.
Article in English | MEDLINE | ID: mdl-35051208

ABSTRACT

SARS-CoV-2, the cause of COVID-19, requires reliable diagnostic methods to track the circulation of this virus. Following the development of RT-qPCR methods to meet this diagnostic need in January 2020, it became clear from interlaboratory studies that the reported Ct values obtained for the different laboratories showed high variability. Despite this the Ct values were explored as a quantitative cut off to aid clinical decisions based on viral load. Consequently, there was a need to introduce standards to support estimation of SARS-CoV-2 viral load in diagnostic specimens. In a collaborative study, INSTAND established two reference materials (RMs) containing heat-inactivated SARS-CoV-2 with SARS-CoV-2 RNA loads of ~107 copies/mL (RM 1) and ~106 copies/mL (RM 2), respectively. Quantification was performed by RT-qPCR using synthetic SARS-CoV-2 RNA standards and digital PCR. Between November 2020 and February 2021, German laboratories were invited to use the two RMs to anchor their Ct values measured in routine diagnostic specimens, with the Ct values of the two RMs. A total of 305 laboratories in Germany were supplied with RM 1 and RM 2. The laboratories were requested to report their measured Ct values together with details on the PCR method they used to INSTAND. This resultant 1,109 data sets were differentiated by test system and targeted gene region. Our findings demonstrate that an indispensable prerequisite for linking Ct values to SARS-CoV-2 viral loads is that they are treated as being unique to an individual laboratory. For this reason, clinical guidance based on viral loads should not cite Ct values. The RMs described were a suitable tool to determine the specific laboratory Ct for a given viral load. Furthermore, as Ct values can also vary between runs when using the same instrument, such RMs could be used as run controls to ensure reproducibility of the quantitative measurements.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Diagnostic Tests, Routine/methods , RNA, Viral/genetics , Reverse Transcriptase Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , Viral Load/methods , COVID-19/epidemiology , COVID-19/virology , Genes, Viral , Germany/epidemiology , Humans , Reproducibility of Results
6.
Clin Chem ; 68(1): 153-162, 2021 12 30.
Article in English | MEDLINE | ID: mdl-34633030

ABSTRACT

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA quantities, measured by reverse transcription quantitative PCR (RT-qPCR), have been proposed to stratify clinical risk or determine analytical performance targets. We investigated reproducibility and how setting diagnostic cutoffs altered the clinical sensitivity of coronavirus disease 2019 (COVID-19) testing. METHODS: Quantitative SARS-CoV-2 RNA distributions [quantification cycle (Cq) and copies/mL] from more than 6000 patients from 3 clinical laboratories in United Kingdom, Belgium, and the Republic of Korea were analyzed. Impact of Cq cutoffs on clinical sensitivity was assessed. The June/July 2020 INSTAND external quality assessment scheme SARS-CoV-2 materials were used to estimate laboratory reported copies/mL and to estimate the variation in copies/mL for a given Cq. RESULTS: When the WHO-suggested Cq cutoff of 25 was applied, the clinical sensitivity dropped to about 16%. Clinical sensitivity also dropped to about 27% when a simulated limit of detection of 106 copies/mL was applied. The interlaboratory variation for a given Cq value was >1000 fold in copies/mL (99% CI). CONCLUSION: While RT-qPCR has been instrumental in the response to COVID-19, we recommend Cq (cycle threshold or crossing point) values not be used to set clinical cutoffs or diagnostic performance targets due to poor interlaboratory reproducibility; calibrated copy-based units (used elsewhere in virology) offer more reproducible alternatives. We also report a phenomenon where diagnostic performance may change relative to the effective reproduction number. Our findings indicate that the disparities between patient populations across time are an important consideration when evaluating or deploying diagnostic tests. This is especially relevant to the emergency situation of an evolving pandemic.


Subject(s)
COVID-19 Nucleic Acid Testing/standards , COVID-19 , Nucleic Acids , Belgium , COVID-19/diagnosis , Humans , Nucleic Acids/analysis , RNA, Viral/analysis , Reproducibility of Results , Republic of Korea , SARS-CoV-2 , Sensitivity and Specificity , United Kingdom
7.
Rapid Commun Mass Spectrom ; 35(20): e9177, 2021 Oct 30.
Article in English | MEDLINE | ID: mdl-34382250

ABSTRACT

RATIONALE: Preparation of in-house reference materials (RMs) is an important aspect of light element stable isotope analysis. While some relevant information is available, there is as yet no clear set of guidelines available covering all aspects of in-house production and characterization of RMs. METHODS: To address this need, the experience of production of certified reference materials under accreditation to ISO 17034:2016 and ISO/IEC 17025:2017 has been distilled into guidance for production of in-house RMs that are fit-for-purpose. RESULTS: The guidance provided covers five areas: (i) planning; (ii) material considerations including preparation, packaging, and storage; (iii) measurements and assessments; (iv) value and uncertainty assignment; and (v) monitoring and use. CONCLUSIONS: In-house RMs prepared by following this guidance can be used to provide traceability to measurement results when used for normalization or for quality control and/or assurance purposes.

8.
Anal Methods ; 13(33): 3641-3648, 2021 09 07.
Article in English | MEDLINE | ID: mdl-34328489

ABSTRACT

Species-specific isotope dilution mass spectrometry (SS-IDMS) has been the calibration method of choice for high accuracy speciation analysis because it can correct for detector sensitivity drifts, matrix effects, and analyte loss during sample preparation and analysis. However, in many cases SS-IDMS calibration is either not applicable (e.g. for monoisotopic elements) or not feasible (e.g. limited by the cost and availability of like-for-like isotopically enriched species). The work presented here demonstrates the potential of a novel on-column species-specific internal calibration approach, which is based on the chromatographic injection of the same species of the analyte as the internal standard (IS), after the sample injection. It can compensate for on-column analyte losses and signal drift and can be applied with any detector capable of recording time-resolved data, provided that enough species resolution can be achieved. The feasibility of this novel calibration strategy for accurate quantitative elemental speciation in complex matrices is demonstrated here through the analysis of inorganic arsenic in rice. An expanded uncertainty (k = 2) of <10% was obtained for a mass fraction range of 60 to 300 µg kg-1 inorganic-As (i-As) in dry rice products. The method is currently used for the certification of i-As in baby food matrices to support Commission Regulation (EU) 2015/1006 in regard to the maximum levels of i-As in foodstuffs.


Subject(s)
Arsenicals , Oryza , Calibration , Feasibility Studies , Mass Spectrometry
10.
Int J Neonatal Screen ; 6(4)2020 Nov 19.
Article in English | MEDLINE | ID: mdl-33228114

ABSTRACT

In 2015, the newborn screening (NBS) programmes in England and Wales were expanded to include four additional disorders: Classical Homocystinuria, Isovaleric Acidemia, Glutaric Aciduria Type 1 and Maple Syrup Urine Disease, bringing the total number of analytes quantified to eight: phenylalanine, tyrosine, leucine, methionine, isovalerylcarnitine, glutarylcarnitine, octanoylcarnitine and decanoylcarnitine. Post-implementation, population data monitoring showed that inter-laboratory variation was greater than expected, with 90th centiles varying from 17 to 59%. We evaluated the effect of stable isotope internal standard (IS) used for quantitation on inter-laboratory variation. Four laboratories analysed routine screening samples (n > 101,820) using a common IS. Inter-laboratory variation was determined for the eight analytes and compared with results obtained using an in-house common IS (n > 102,194). A linear mixed-effects model was fitted to the data. Using a common IS mix reduced the inter-laboratory variation significantly (p < 0.05) for five analytes. For three analytes, the lack of significance was explained by use of individual laboratory "calibration factors". For screening programmes where laboratories adhere to single analyte cut-off values (COVs), it is important that inter-laboratory variation is minimised, primarily to prevent false positive results. Whilst the use of a common IS helps achieve this, it is evident that instrument set-up also contributes to inter-laboratory variation.

11.
J Am Soc Mass Spectrom ; 31(3): 553-564, 2020 Mar 04.
Article in English | MEDLINE | ID: mdl-32008322

ABSTRACT

As monoclonal antibodies (mAbs) rapidly emerge as a dominant class of therapeutics, so does the need for suitable analytical technologies to monitor for changes in protein higher order structure (HOS) of these biomolecules. Reference materials (RM) serve a key analytical purpose of benchmarking the suitability and robustness of both established and emerging analytical procedures for both drug producers and regulators. Here, two simple enzymatic protocols for generating Fc-glycan variants from the NISTmAb RM are described and both global and localized changes in HOS between the RM and these Fc-glycan variants are characterized using hydrogen deuterium exchange-mass spectrometry (HDX-MS) and ion mobility spectrometry-mass spectrometry (IMS-MS) measurements. An alternative statistical approach is described where measurement thresholds that differentiate between measurement variability and significant structural changes were established on the basis of experimental data. Measurements revealed decreases in structural stability correlating with the degree of Fc-glycan structure loss, especially at the CH2/CH3 domain interface. These data promote the use of this RM and these Fc-glycan variants for establishing the sensitivity of and validating analytical methods for the detection of HOS measurements of mAbs.


Subject(s)
Antibodies, Monoclonal, Humanized/chemistry , Antibodies, Monoclonal/chemistry , Immunoglobulin G/chemistry , Ion Mobility Spectrometry/methods , Polysaccharides/analysis , Glycosylation , Humans , Ion Mobility Spectrometry/standards , Models, Molecular , Protein Conformation , Protein Domains , Reference Standards
12.
Sci Justice ; 59(1): 9-19, 2019 01.
Article in English | MEDLINE | ID: mdl-30654973

ABSTRACT

Forensic application of carbon isotope ratio measurements of honey and honey protein to investigate the degree of adulteration with high fructose corn syrup or other C4 plant sugars is well established. These measurements must use methods that exhibit suitable performance criteria, particularly with regard to measurement uncertainty and traceability - low levels of adulteration can only be detected by methods that result in suitably small measurement uncertainties such that differences of 1‰ or less can be reliably detected. Inter-laboratory exercises are invaluable to assess the state-of-the art of measurement capabilities of laboratories necessary to achieve such performance criteria. National and designated metrology institutes from a number of countries recently participated in an inter-laboratory assessment (CCQM-K140) of stable carbon isotope ratio determination of bulk honey. The same sample material was distributed to a number of forensic isotope analysis laboratories that could not participate directly in the metrological comparison. The results from these studies have demonstrated that the majority of participants provided isotope delta values with acceptable performance metrics; that all participants ensured traceability of their results; and that where measurement uncertainties were reported; these were fit-for-purpose. A number of the forensic laboratories only reported precision rather than full estimates of measurement uncertainty and this was the major cause of the few instances of questionable performance metrics. Reporting of standard deviations in place of measurement uncertainties is common practice outside metrology institutes and the implications for interpretations of small differences in isotopic compositions are discussed. The results have also highlighted a number of considerations that are useful for organisers of similar inter-laboratory studies in the future.


Subject(s)
Carbon Isotopes/analysis , Forensic Sciences/methods , Honey/analysis , Laboratories , Uncertainty , Internationality , Reproducibility of Results
13.
Clin Chem ; 64(9): 1296-1307, 2018 09.
Article in English | MEDLINE | ID: mdl-29903874

ABSTRACT

BACKGROUND: Genetic testing of tumor tissue and circulating cell-free DNA for somatic variants guides patient treatment of many cancers. Such measurements will be fundamental in the future support of precision medicine. However, there are currently no primary reference measurement procedures available for nucleic acid quantification that would support translation of tests for circulating tumor DNA into routine use. METHODS: We assessed the accuracy of digital PCR (dPCR) for copy number quantification of a frequently occurring single-nucleotide variant in colorectal cancer (KRAS c.35G>A, p.Gly12Asp, from hereon termed G12D) by evaluating potential sources of uncertainty that influence dPCR measurement. RESULTS: Concentration values for samples of KRAS G12D and wild-type plasmid templates varied by <1.2-fold when measured using 5 different assays with varying detection chemistry (hydrolysis, scorpion probes, and intercalating dyes) and <1.3-fold with 4 commercial dPCR platforms. Measurement trueness of a selected dPCR assay and platform was validated by comparison with an orthogonal method (inductively coupled plasma mass spectrometry). The candidate dPCR reference measurement procedure showed linear quantification over a wide range of copies per reaction and high repeatability and interlaboratory reproducibility (CV, 2%-8% and 5%-10%, respectively). CONCLUSIONS: This work validates dPCR as an SI-traceable reference measurement procedure based on enumeration and demonstrates how it can be applied for assignment of copy number concentration and fractional abundance values to DNA reference materials in an aqueous solution. High-accuracy measurements using dPCR will support the implementation and traceable standardization of molecular diagnostic procedures needed for advancements in precision medicine.


Subject(s)
Polymerase Chain Reaction/methods , Precision Medicine , DNA Copy Number Variations , Humans , Mass Spectrometry , Reproducibility of Results
14.
Bioanalysis ; 10(4): 197-204, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29345496

ABSTRACT

European Bioanalysis Forum Workshop, Lisbon, Portugal, September 2016: At the recent European Bioanalysis Forum Focus Workshop, 'current analysis of immunogenicity: best practices and regulatory hurdles', several important challenges facing the bioanalytical community in relation to immunogenicity assays were discussed through a mixture of presentations and panel sessions. The main areas of focus were the evolving regulatory landscape, challenges of assay interferences from either drug or target, cut-point setting and whether alternative assays can be used to replace neutralizing antibody assays. This workshop report captures discussions and potential solutions and/or recommendations made by the speakers and delegates.


Subject(s)
Antibodies, Neutralizing/analysis , Biological Products/immunology , Drug Tolerance/immunology , Immunoassay/standards , Biological Products/therapeutic use , Drug Discovery , Guidelines as Topic , Humans
15.
J AOAC Int ; 101(1): 162-169, 2018 Jan 01.
Article in English | MEDLINE | ID: mdl-29202918

ABSTRACT

It is now well known that an incident investigated in the United Kingdom in 2015 of cumin alleged to be contaminated with almond, a risk for people with almond allergy, was caused by the Prunus species, Prunus mahaleb. In the United Kingdom, the Government Chemist offers a route of technical appeal from official findings in the food control system. Findings of almond in two official samples, cumin and paprika, which had prompted action to exclude the consignments from the food chain, were so referred. Herein are described the approaches deployed to resolve the analytical issues during the investigation of the incidents. The cross-reactivity of ELISA to Prunus species was confirmed, and although this is useful in screening for the genus, orthogonal techniques are required to identify the species and confirm its presence. Two novel PCR assays were developed: one specific for P. mahaleb and the other a screening method capable of identifying common Prunus DNA. Peptides unique to almond and mahaleb were identified, permitting LC-tandem MS and criteria were developed for peptide identification to forensic standards. This work enables a staged approach to be taken to any future incident thought to involve Prunus species and provides a template for the investigation of similar incidents.


Subject(s)
Allergens/analysis , Enzyme-Linked Immunosorbent Assay , Food Analysis , Food Contamination/analysis , Food Hypersensitivity , Prunus dulcis/chemistry , Mass Spectrometry , Molecular Biology , Prunus dulcis/genetics , United Kingdom
16.
Sci Rep ; 7(1): 17542, 2017 12 13.
Article in English | MEDLINE | ID: mdl-29235533

ABSTRACT

We describe a novel generic method to derive the unknown endogenous concentrations of analyte within complex biological matrices (e.g. serum or plasma) based upon the relationship between the immunoassay signal response of a biological test sample spiked with known analyte concentrations and the log transformed estimated total concentration. If the estimated total analyte concentration is correct, a portion of the sigmoid on a log-log plot is very close to linear, allowing the unknown endogenous concentration to be estimated using a numerical method. This approach obviates conventional relative quantification using an internal standard curve and need for calibrant diluent, and takes into account the individual matrix interference on the immunoassay by spiking the test sample itself. This technique is based on standard additions for chemical analytes. Unknown endogenous analyte concentrations within even 2-fold diluted human plasma may be determined reliably using as few as four reaction wells.


Subject(s)
Immunoassay/methods , Amyloid beta-Peptides/blood , Blood Chemical Analysis/methods , Calibration , Female , Humans , Hydrocortisone/blood , Linear Models , Male , Peptide Fragments/blood , Reproducibility of Results
17.
Clin Chem ; 63(2): 525-531, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27979961

ABSTRACT

BACKGROUND: Tyrosine kinase inhibitors (TKIs) are the cornerstone of successful clinical management of patients with chronic myeloid leukemia (CML). Quantitative monitoring of the percentage of the fusion transcript BCR-ABL1 (breakpoint cluster region-c-abl oncogene 1, non-receptor tyrosine kinase) BCR-ABL1IS (%BCR-ABL1IS) by reverse transcription-quantitative PCR (RT-qPCR) is the gold standard strategy for evaluating patient response to TKIs and classification into prognostic subgroups. However, this approach can be challenging to perform in a reproducible manner. Reverse-transcription digital PCR (RT-dPCR) is an adaptation of this method that could provide the robust and standardized workflow needed for truly standardized patient stratification. METHODS: BCR-ABL1 and ABL1 transcript copy numbers were quantified in a total of 102 samples; 70 CML patients undergoing TKI therapy and 32 non-CML individuals. 3 commercially available digital PCR platforms (QS3D, QX200 and Raindrop) were compared with the platform routinely used in the clinic for RT-qPCR using the EAC (Europe Against Cancer) assay. RESULTS: Measurements on all instruments correlated well when the %BCR-ABL1IS was ≥0.1%. In patients with residual disease below this level, greater variations were measured both within and between instruments limiting comparable performance to a 4 log dynamic range. CONCLUSIONS: RT-dPCR was able to quantify low-level BCR-ABL1 transcript copies but was unable to improve sensitivity below the level of detection achieved by RT-qPCR. However, RT-dPCR was able to perform these sensitive measurements without use of a calibration curve. Adaptions to the protocol to increase the amount of RNA measured are likely to be necessary to improve the analytical sensitivity of BCR-ABL testing on a dPCR platform.


Subject(s)
Fusion Proteins, bcr-abl/genetics , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/genetics , Neoplasm, Residual/genetics , Proto-Oncogene Proteins c-abl/genetics , Real-Time Polymerase Chain Reaction , Reverse Transcriptase Polymerase Chain Reaction , Humans , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/diagnosis , Neoplasm, Residual/diagnosis
18.
Anal Chem ; 89(3): 1724-1733, 2017 02 07.
Article in English | MEDLINE | ID: mdl-27935690

ABSTRACT

This study tested the claim that digital PCR (dPCR) can offer highly reproducible quantitative measurements in disparate laboratories. Twenty-one laboratories measured four blinded samples containing different quantities of a KRAS fragment encoding G12D, an important genetic marker for guiding therapy of certain cancers. This marker is challenging to quantify reproducibly using quantitative PCR (qPCR) or next generation sequencing (NGS) due to the presence of competing wild type sequences and the need for calibration. Using dPCR, 18 laboratories were able to quantify the G12D marker within 12% of each other in all samples. Three laboratories appeared to measure consistently outlying results; however, proper application of a follow-up analysis recommendation rectified their data. Our findings show that dPCR has demonstrable reproducibility across a large number of laboratories without calibration. This could enable the reproducible application of molecular stratification to guide therapy and, potentially, for molecular diagnostics.


Subject(s)
Proto-Oncogene Proteins p21(ras)/genetics , Real-Time Polymerase Chain Reaction/methods , DNA/chemistry , DNA/metabolism , Humans , Polymorphism, Single Nucleotide , Reproducibility of Results , Sequence Analysis, DNA
19.
Biomol Detect Quantif ; 8: 15-28, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27335807

ABSTRACT

Measurement of RNA can be used to study and monitor a range of infectious and non-communicable diseases, with profiling of multiple gene expression mRNA transcripts being increasingly applied to cancer stratification and prognosis. An international comparison study (Consultative Committee for Amount of Substance (CCQM)-P103.1) was performed in order to evaluate the comparability of measurements of RNA copy number ratio for multiple gene targets between two samples. Six exogenous synthetic targets comprising of External RNA Control Consortium (ERCC) standards were measured alongside transcripts for three endogenous gene targets present in the background of human cell line RNA. The study was carried out under the auspices of the Nucleic Acids (formerly Bioanalysis) Working Group of the CCQM. It was coordinated by LGC (United Kingdom) with the support of National Institute of Standards and Technology (USA) and results were submitted from thirteen National Metrology Institutes and Designated Institutes. The majority of laboratories performed RNA measurements using RT-qPCR, with datasets also being submitted by two laboratories based on reverse transcription digital polymerase chain reaction and one laboratory using a next-generation sequencing method. In RT-qPCR analysis, the RNA copy number ratios between the two samples were quantified using either a standard curve or a relative quantification approach. In general, good agreement was observed between the reported results of ERCC RNA copy number ratio measurements. Measurements of the RNA copy number ratios for endogenous genes between the two samples were also consistent between the majority of laboratories. Some differences in the reported values and confidence intervals ('measurement uncertainties') were noted which may be attributable to choice of measurement method or quantification approach. This highlights the need for standardised practices for the calculation of fold change ratios and uncertainties in the area of gene expression profiling.

20.
J Clin Microbiol ; 54(2): 392-400, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26659206

ABSTRACT

Digital PCR (dPCR) is being increasingly used for the quantification of sequence variations, including single nucleotide polymorphisms (SNPs), due to its high accuracy and precision in comparison with techniques such as quantitative PCR (qPCR) and melt curve analysis. To develop and evaluate dPCR for SNP detection using DNA, RNA, and clinical samples, an influenza virus model of resistance to oseltamivir (Tamiflu) was used. First, this study was able to recognize and reduce off-target amplification in dPCR quantification, thereby enabling technical sensitivities down to 0.1% SNP abundance at a range of template concentrations, a 50-fold improvement on the qPCR assay used routinely in the clinic. Second, a method was developed for determining the false-positive rate (background) signal. Finally, comparison of dPCR with qPCR results on clinical samples demonstrated the potential impact dPCR could have on clinical research and patient management by earlier (trace) detection of rare drug-resistant sequence variants. Ultimately this could reduce the quantity of ineffective drugs taken and facilitate early switching to alternative medication when available. In the short term such methods could advance our understanding of microbial dynamics and therapeutic responses in a range of infectious diseases such as HIV, viral hepatitis, and tuberculosis. Furthermore, the findings presented here are directly relevant to other diagnostic areas, such as the detection of rare SNPs in malignancy, monitoring of graft rejection, and fetal screening.


Subject(s)
Antiviral Agents/pharmacology , Drug Resistance, Viral , Influenza A virus/drug effects , Influenza A virus/genetics , Influenza, Human/diagnosis , Influenza, Human/virology , Mutation , Antiviral Agents/therapeutic use , Genes, Viral , Humans , Influenza A Virus, H1N1 Subtype/drug effects , Influenza A Virus, H1N1 Subtype/genetics , Influenza, Human/drug therapy , Molecular Typing , Oseltamivir/pharmacology , Polymorphism, Single Nucleotide , Real-Time Polymerase Chain Reaction/methods , Reverse Transcriptase Polymerase Chain Reaction , Sensitivity and Specificity