Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JAMA Netw Open ; 6(9): e2331798, 2023 09 05.
Article in English | MEDLINE | ID: mdl-37656458

ABSTRACT

Importance: Testing new medical devices or procedures in terms of safety, effectiveness, and durability should follow the strictest methodological rigor before implementation. Objectives: To review and analyze studies investigating devices and procedures used in intracranial aneurysm (IA) treatment for methods and completeness of reporting and to compare the results of studies with positive, uncertain, and negative conclusions. Data Sources: Embase, MEDLINE, Web of Science, and The Cochrane Central Register of Clinical Trials were searched for studies on IA treatment published between January 1, 1995, and the October 1, 2022. Grey literature was retrieved from Google Scholar. Study Selection: All studies making any kind of claims of safety, effectiveness, or durability in the field of IA treatment were included. Data Extraction and Synthesis: Using a predefined data dictionary and analysis plan, variables ranging from patient and aneurysm characteristics to the results of treatment were extracted, as were details pertaining to study methods and completeness of reporting. Extraction was performed by 10 independent reviewers. A blinded academic neuro-linguist without involvement in IA research evaluated the conclusion of each study as either positive, uncertain, or negative. The study followed Preferring Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Main Outcomes and Measures: The incidence of domain-specific outcomes between studies with positive, uncertain, or negative conclusions regarding safety, effectiveness, or durability were compared. The number of studies that provided a definition of safety, effectiveness, or durability and the incidence of incomplete reporting of domain-specific outcomes were evaluated. Results: Overall, 12 954 studies were screened, and 1356 studies were included, comprising a total of 410 993 treated patients. There was no difference in the proportion of patients with poor outcome or in-hospital mortality between studies claiming a technique was safe, uncertain, or not safe. Similarly, there was no difference in the proportion of IAs completely occluded at last follow-up between studies claiming a technique was effective, uncertain, or noneffective. Less than 2% of studies provided any definition of safety, effectiveness, or durability, and only 1 of the 1356 studies provided a threshold under which the technique would be considered unsafe. Incomplete reporting was found in 546 reports (40%). Conclusions and Relevance: In this systematic review and meta-analysis of IA treatment literature, studies claiming safety, effectiveness, or durability of IA treatment had methodological flaws and incomplete reporting of relevant outcomes supporting these claims.


Subject(s)
Intracranial Aneurysm , Neurology , Humans , Intracranial Aneurysm/therapy , Hospital Mortality , Uncertainty
2.
Neurosurg Rev ; 46(1): 45, 2023 Jan 28.
Article in English | MEDLINE | ID: mdl-36708446

ABSTRACT

Trapped or isolated fourth ventricle (TFV) is a rare but critical neurosurgical condition, mostly occurring in pediatric patients, caused by a blockage of the in- and outlets of the fourth ventricle. The purpose of this study is to review all available data on the treatment options of TFV and to compare their safety, efficacy, and durability. MEDLINE, Embase, and Google Scholar were searched from inception to September 13, 2022, for prospective or retrospective cohorts, case-control studies, case series or case reports, reporting detailing outcomes of TFV patients, treated with an endoscopic-, microsurgical-, shunt placement,- or hybrid approaches to TFV. All authors were contacted to provide individual patient data. Eighty-seven articles (314 patients) were included in the individual patient data meta-analysis (IPD) and 9 (151 patients) in the cohort meta-analysis. The IPD revealed that primary endoscopic (aOR 0.21; [95% CI 0.08-0.57]) and microsurgical interventions (aOR 0.21; [95% CI 0.05-0.82]) were associated with a significantly lower revision rate, compared to shunt placement, when adjusted for confounders. Endoscopy was also associated with a significantly higher rate of clinical improvement (aOR 4.56; [95% CI 1.2-18]). The meta-analysis revealed no significant difference in revision rate between the endoscopic (0.33 [95% CI 0.0-0.52]) and shunt group (0.44 [95% CI 0.0-1.0]). Endoscopy should be considered as the first-line treatment of TFV due to its superior efficacy, durability, and similar safety, compared to shunt placement and its minimally invasive nature. Microsurgery should be considered as a second treatment option, due to its similar clinical outcomes and revision rate as endoscopy, but it is more invasive in nature.


Subject(s)
Fourth Ventricle , Hydrocephalus , Child , Humans , Fourth Ventricle/surgery , Retrospective Studies , Hydrocephalus/surgery , Prospective Studies , Stents/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...