Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 346
Filter
1.
Article in English | MEDLINE | ID: mdl-38702202

ABSTRACT

Disc displacement without reduction (DDwoR) can cause pain and limitations in mouth opening, with a significant impact on function. The optimal management strategy for DDwoR is unclear. Treatments include conservative management such as mandibular manipulation, occlusal splints, and patient education/self-management, as well as arthrocentesis, which is a minimally invasive procedure. The aim of this systematic review and meta-analysis was to ascertain whether there is a role for arthrocentesis in the management of DDwoR. Studies analysing the outcomes pain and maximum mouth opening (MMO) in patients with DDwoR treated by arthrocentesis or occlusal coverage devices were eligible for inclusion. Following a database search, six studies with a total of 343 participants were found to be eligible for analysis (three prospective observational studies, one retrospective observational study, one non-randomized single-blind clinical trial, and one unblinded randomized clinical trial). When compared to occlusal coverage splints, arthrocentesis demonstrated a slight improvement in pain, although this was statistically non-significant (standardized mean difference (SMD) -0.50, 95% confidence interval (CI) -1.04 to 0.05, P = 0.07; I2 = 81%), and a significant improvement in MMO (SMD 0.79 mm, 95% CI 0.24-1.35 mm, P = 0.005; I2 = 79%). However, due to the significant heterogeneity between studies and the high risk of bias, along with the paucity of double-blind randomized controlled clinical trials, definitive conclusions cannot be drawn for this clinical question.

3.
Eur Phys J C Part Fields ; 84(1): 18, 2024.
Article in English | MEDLINE | ID: mdl-38205101

ABSTRACT

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ∼1.4m3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12h down to 1.5h.

4.
J Hosp Infect ; 144: 75-84, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38040038

ABSTRACT

BACKGROUND: The contagiousness of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is known to be linked to the emission of bioaerosols. Thus, aerosol-generating procedures (AGPs) could increase the risk of infection among healthcare workers (HCWs). AIM: To investigate the impact of an aerosol protection box, the SplashGuard Caregiver (SGGC) with suction system, by direct analysis of the presence of viral particles after an AGP, and by using the computational fluid dynamics (CFD) simulation method. METHODS: This prospective observational study investigated HCWs caring for patients with SARS-CoV-2 admitted to an intensive care unit (ICU). Rooms were categorized as: SGCG present and SGCG absent. Virus detection was performed through direct analysis, and using a CFD model to simulate the movement dynamics of airborne particles produced by a patient's respiratory activities. FINDINGS: Of the 67 analyses performed, three samples tested positive on quantitative polymerase chain reaction: one of 33 analyses in the SCCG group (3%) and two of 34 analyses in the non-SGCG group (5.9%). CFD simulations showed that: (1) reduction of the gaps of an SGCG could decrease the number of emitted particles remaining airborne within the room by up to 70%; and (2) positioning HCWs facing the opposite direction to the main air flow would reduce their exposure. CONCLUSIONS: This study documented the presence of SARS-CoV-2 among HCWs in a negative pressure ICU room of an infected patient with or without the use of an SGCG. The simulation will help to improve the design of the SGCG and the positioning of HCWs in the room.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/prevention & control , Caregivers , Prospective Studies , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Respiratory Aerosols and Droplets , Intensive Care Units
6.
Eur Phys J C Part Fields ; 83(11): 1061, 2023.
Article in English | MEDLINE | ID: mdl-38021215

ABSTRACT

We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5 m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 105 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000 m3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to ±50µT (homogeneous components) and ±5µT/m (first-order gradients), suppressing them to a few µT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.

8.
Rev Sci Instrum ; 93(9): 095105, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36182526

ABSTRACT

We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute, which features an interior cubic volume with each side of length 2.92 m, thus providing an accessible space of 25 m3. The MSR has 87 openings of diameter up to 220 mm for operating the experimental apparatus inside and an intermediate space between the layers for housing sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1 m3 below 100 pT and a field below 600 pT in the entire inner volume, up to 4 cm to the walls. The quasi-static shielding factor at 0.01 Hz measured with a sinusoidal 2 µT peak-to-peak signal is about 100 000 in all three spatial directions and increases rapidly with frequency to reach 108 above 1 Hz.

9.
J Dairy Sci ; 105(6): 5506-5518, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35465991

ABSTRACT

Objectives were to evaluate the effect of 2 analogs of PGF2α (cloprostenol vs. dinoprost) and 2 doses (1 injection vs. 2 injections) on luteolysis, follicle diameter, hormonal concentrations, and time to ovulation in dairy heifers. Holstein heifers were fitted with automated estrus detection devices and had their estrous cycle synchronized using PGF2α and an intravaginal insert containing progesterone. Heifers detected in estrus were blocked by weight and randomly assigned to 1 of 4 treatments in a 2 × 2 factorial arrangement: cloprostenol on d 7 after estrus (CLOx1; n = 45), cloprostenol on d 7 and 8 after estrus (CLOx2; n = 41), dinoprost on d 7 after estrus (DINx1; n = 43), or dinoprost on d 7 and 8 after estrus (DINx2; n = 44). Treatment with the first injection of PGF2α was defined as experiment d 0. Area and blood flow of corpus luteum (CL) and diameter of follicles >5 mm were recorded every 12 h from d 0 to estrus and every 6 h thereafter until ovulation. Blood was sampled every 6 h from d 0 until ovulation. Heifers treated with cloprostenol had shorter interval to luteolysis (± SEM; CLOx1 = 23.5 ± 2.2, CLOx2 = 22.9 ± 2.2, DINx1 = 32.6 ± 2.7, DINx2 = 26.4 ± 2.1 h); however, time to ovulation was not affected by treatment. A smaller proportion of heifers treated with a single injection of PGF2α underwent luteolysis compared with heifers treated with 2 injections (CLOx1 = 84.6 ± 6.2, CLOx2 = 100.0 ± 0.0, DINx1 = 59.7 ± 9.8, DINx2 = 96.3 ± 2.7%). Proportion of heifers that ovulated was smaller for DINx1 compared with other treatments (CLOx1 = 88.8 ± 5.1, CLOx2 = 100.0 ± 0.0, DINx1 = 55.2 ± 9.7, DINx2 = 94.4 ± 3.4%). Ovulatory follicle diameter was larger for DINx1 (18.2 ± 2.7 mm) compared with DINx2 (17.4 ± 2.7 mm), whereas dose did not affect the diameter of the ovulatory follicle in heifers treated with cloprostenol (CLOx1 = 17.6 ± 2.7 vs. CLOx2 = 17.8 ± 2.8 mm). Among heifers that underwent luteolysis, progesterone concentrations from 18 to 36 h after treatment were lesser in heifers treated with cloprostenol compared with those treated with dinoprost. Type of PGF2α did not affect progesterone concentrations past 36 h from treatment; however, heifers treated with 2 PGF2α injections had lesser progesterone concentrations and CL blood flow from 36 to 72 h after treatment compared with heifers that received a single PGF2α injection.


Subject(s)
Dinoprost , Luteolysis , Animals , Cattle , Cloprostenol/pharmacology , Estrus Synchronization , Female , Insemination, Artificial/veterinary , Ovulation , Progesterone
10.
Eur Phys J C Part Fields ; 81(6): 512, 2021.
Article in English | MEDLINE | ID: mdl-34720721

ABSTRACT

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is of the experimental method and setup is given, the sensitivity requirements for the apparatus are derived, and its technical design is described.

11.
Eur Phys J A Hadron Nucl ; 57(4): 152, 2021.
Article in English | MEDLINE | ID: mdl-34776778

ABSTRACT

Psychological bias towards, or away from, prior measurements or theory predictions is an intrinsic threat to any data analysis. While various methods can be used to try to avoid such a bias, e.g. actively avoiding looking at the result, only data blinding is a traceable and trustworthy method that can circumvent the bias and convince a public audience that there is not even an accidental psychological bias. Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment (nEDM), as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a false signal. We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons within each measurement cycle. The flexible algorithm may be applied twice (or more) to the data, thus providing the option of sequentially applying various blinding offsets for separate analysis steps with independent teams. The subtle manner in which the data are modified allows one subsequently to adjust the algorithm and to produce a re-blinded data set without revealing the initial blinding offset. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable projects elsewhere.

12.
Res Involv Engagem ; 7(1): 40, 2021 Jun 14.
Article in English | MEDLINE | ID: mdl-34127076

ABSTRACT

BACKGROUND: England operates a National Data Opt-Out (NDOO) for the secondary use of confidential health data for research and planning. We hypothesised that public awareness and support for the secondary use of health data and the NDOO would vary by participant demography and healthcare experience. We explored patient/public awareness and perceptions of secondary data use, grouping potential researchers into National Health Service (NHS), academia or commercial. We assessed awareness of the NDOO system amongst patients, carers, healthcare staff and the public. We co-developed recommendations to consider when sharing unconsented health data for research. METHODS: A patient and public engagement program, co-created and including patient and public workshops, questionnaires and discussion groups regarding anonymised health data use. RESULTS: There were 350 participants in total. Central concerns for health data use included unauthorised data re-use, the potential for discrimination and data sharing without patient benefit. 94% of respondents were happy for their data to be used for NHS research, 85% for academic research and 68% by health companies, but less than 50% for non-healthcare companies and opinions varied with demography and participant group. Questionnaires showed that knowledge of the NDOO was low, with 32% of all respondents, 53% of all NHS staff and 29% of all patients aware of the NDOO. Recommendations to guide unconsented secondary health data use included that health data use should benefit patients; data sharing decisions should involve patients/public. That data should remain in close proximity to health services with the principles of data minimisation applied. Further, that there should be transparency in secondary health data use, including publicly available lists of projects, summaries and benefits. Finally, organisations involved in data access decisions should participate in programmes to increase knowledge of the NDOO, to ensure public members were making informed choices about their own data. CONCLUSION: The majority of participants in this study reported that the use of healthcare data for secondary purposes was acceptable when accessed by NHS. Academic and health-focused companies. However, awareness was limited, including of the NDOO. Further development of publicly-agreed recommendations for secondary health data use may improve both awareness and confidence in secondary health data use.


Health data from routine care can be pseudonymised (with a link remaining to the patient but identifying features removed) or anonymised (with identifying features removed and the link to the patient severed) and used for research and health planning; termed "secondary use". The National Health Service (NHS) is a single publicly-funded health service for the United Kingdom (UK). The NHS supports secondary data use with a National Data opt-out system. The potential benefits of data secondary use are clear but concerns have been raised. Although the Data Opt-Out is publicised, it is unclear how much public awareness there is of this scheme. We report a patient and publicly created and delivered series of activities including > 350 people; with young adults, patients, NHS staff and the public; to assess concerns, knowledge and acceptance of data sharing.Perceptions of and support for secondary health data use varied depending on who was asked (by age, gender) and their experience of health services (Staff member, patient, member of the public). Knowledge of schemes to limit secondary data use (such as the UK National Data Op-Out) was low, even among NHS staff. The main concerns of sharing health data included onward data use, the potential for discrimination and exploitation and commercial gain from data use with no benefit to patients. Despite this, most participants agreed with health data sharing with NHS, academic and commercial health-based entities. Agreed, co-created themes to increase the acceptability of health data secondary use included education about 'Opt-out' schemes, health service oversight of data use (as the most trusted partner), public and patient involvement in data sharing decisions and public transparency.

13.
Rev Sci Instrum ; 92(12): 124703, 2021 Dec 01.
Article in English | MEDLINE | ID: mdl-34972424

ABSTRACT

The magnetic scalar potential U(r⃗) has an intuitive physical interpretation, representing the electric current I = ΔU, which must be directed between any pair of isocontours along the boundary of a region, differing in potential by ΔU, in order to generate the corresponding magnetic intensity H⃗=-∇⃗U inside the region with no tangential component outside the boundary. This physical significance is exploited to invert the design process of hermetic (fringeless) electromagnetic coils from standard iterative techniques (calculating the magnetic field of refined current distributions) to a procedure for calculating the exact surface currents required to generate a given field configuration. A practical construction algorithm is given to produce the prescribed field in a "Target" region (constrained only by Maxwell's equations) while confining the fringe field to a specified hermetic "Return" region. Example coils are analyzed along with a discussion of the limits of precision of the constructed field.

14.
JDS Commun ; 2(6): 334-339, 2021 Nov.
Article in English | MEDLINE | ID: mdl-36337113

ABSTRACT

The effect of feeding a single TMR versus multiple rations across the day that differ in concentrations of neutral detergent fiber (NDF) and starch on the daily pattern of rumen microbial populations was characterized. Diets included a control total mixed ration (CON; 33.3% NDF), a low-fiber diet (LF; 29.6% NDF), and a high-fiber diet (HF; 34.8% NDF). Nine cannulated Holstein cows were assigned to 1 of 3 treatment sequences in a 3 × 3 Latin square design. Treatments included feeding CON ad libitum at 0900 h, feeding HF at 70% of daily offering at 0900 h and LF at 30% of daily offering at 2200 h (H/L), and feeding LF at 30% of daily offering at 0900 h and HF at 70% of daily offering at 1300 h (L/H). Rumen digesta was collected to represent every 3 h across the day, microbial DNA was extracted, and real-time quantitative PCR was used to determine the relative abundances of total bacteria, total fungi, total protozoa, Butyrivibrio fibrisolvens, Butyrivibrio hungatei, Fibrobacter succinogenes, Megasphaera elsdenii, Prevotella bryantii, Ruminococcus albus, Selenomonas ruminantium, and Streptococcus bovis. The relative abundances of total bacteria, total ciliated protozoa, F. succinogenes, P. bryantii, R. albus, S. ruminantium, and Strep. bovis were affected by time of day. Additionally, treatment affected the relative abundance of certain microbial groups at specific times of day. Notably, H/L treatment dramatically increased the relative abundances of B. fibrisolvens, B. hungatei, and Strep. bovis at 0900 h, by 2.5-, 5.4-, and 4.4-fold, respectively. Furthermore, the relative abundances of B. hungatei (3.9-fold), M. elsdenii (3.9-fold), R. albus (1.3-fold), S. ruminantium (1.3-fold), and Strep. bovis (4.5-fold) were greatly increased by L/H at 0900 h. At 0600 h, the relative abundance of F. succinogenes was 58% greater in L/H than H/L and the relative abundance of P. bryantii was 49% greater in H/L than L/H. Results suggest that there is a daily pattern of selected microbial populations that is altered by feeding rations that differ in NDF and starch within a day, with the greatest difference occurring before morning feeding.

15.
Phys Rev Lett ; 125(13): 131803, 2020 Sep 25.
Article in English | MEDLINE | ID: mdl-33034491

ABSTRACT

We report the first precision measurement of the parity-violating asymmetry in the direction of proton momentum with respect to the neutron spin, in the reaction ^{3}He(n,p)^{3}H, using the capture of polarized cold neutrons in an unpolarized active ^{3}He target. The asymmetry is a result of the weak interaction between nucleons, which remains one of the least well-understood aspects of electroweak theory. The measurement provides an important benchmark for modern effective field theory and potential model calculations. Measurements like this are necessary to determine the spin-isospin structure of the hadronic weak interaction. Our asymmetry result is A_{PV}=[1.55±0.97(stat)±0.24(sys)]×10^{-8}, which has the smallest uncertainty of any hadronic parity-violating asymmetry measurement so far.

16.
J Small Anim Pract ; 61(6): E1-E35, 2020 06.
Article in English | MEDLINE | ID: mdl-32227347

ABSTRACT

The World Small Animal Veterinary Association Vaccination Guidelines Group has produced global guidelines for small companion animal practitioners on best practice in canine and feline vaccination. Recognising that there are unique aspects of veterinary practice in certain geographical regions of the world, the Vaccination Guidelines Group undertook a regional project in Latin America between 2016 and 2019, culminating in the present document. The Vaccination Guidelines Group gathered scientific and demographic data during visits to Argentina, Brazil and Mexico, by discussion with national key opinion leaders, visiting veterinary practices and review of the scientific literature. A questionnaire survey was completed by 1390 veterinarians in five Latin American countries and the Vaccination Guidelines Group delivered continuing education at seven events attended by over 3500 veterinarians. The Vaccination Guidelines Group recognised numerous challenges in Latin America, for example: (1) lack of national oversight of the veterinary profession, (2) extraordinary growth in private veterinary schools of undetermined quality, (3) socioeconomic constraints on client engagement with preventive health care, (4) high regional prevalence of some key infectious diseases (e.g. feline leukaemia virus infection, canine visceral leishmaniosis), (5) almost complete lack of minimal antigen vaccine products as available in other markets, (6) relative lack of vaccine products with extended duration of immunity as available in other markets, (7) availability of vaccine products withdrawn from other markets (e.g. Giardia vaccine) or unique to Latin America (e.g. some Leishmania vaccines), (8) accessibility of vaccines directly by pet owners or breeders such that vaccination is not delivered under veterinary supervision, (9) limited availability of continuing education in veterinary vaccinology and lack of compulsion for continuing professional development and (10) limited peer-reviewed published scientific data on small companion animal infectious diseases (with the exception of leishmaniosis) and lack of support for such academic research. In this document, the Vaccination Guidelines Group summarises the findings of this project and assesses in evidence-based fashion the scientific literature pertaining to companion animal vaccine-preventable diseases in Latin America. The Vaccination Guidelines Group makes some recommendations on undergraduate and postgraduate education and academic research. Recognising that current product availability in Latin America does not permit veterinarians in these countries to vaccinate according to the global World Small Animal Veterinary Association guidelines, the Vaccination Guidelines Group makes a series of "pragmatic" recommendations as to what might be currently achievable, and a series of "aspirational" recommendations as to what might be desirable for the future. The concept of "vaccine husbandry" is addressed via some simple guidelines for the management of vaccine products in the practice. Finally, the Vaccination Guidelines Group emphasises the global trend towards delivery of vaccination as one part of an "annual health check" or "health care plan" that reviews holistically the preventive health care needs of the individual pet animal. Latin American practitioners should transition towards these important new practices that are now well embedded in more developed veterinary markets. The document also includes 70 frequently asked questions and their answers; these were posed to the Vaccination Guidelines Group during our continuing education events and small group discussions and should address many of the issues surrounding delivery of vaccination in the Latin American countries. Spanish and Portuguese translations of this document will be made freely available from the on-line resource pages of the Vaccination Guidelines Group.


Subject(s)
Cat Diseases , Dog Diseases , Vaccination/veterinary , Veterinarians , Animals , Cat Diseases/prevention & control , Cats , Dog Diseases/prevention & control , Dogs , Humans , Latin America
17.
Phys Rev Lett ; 124(8): 081803, 2020 Feb 28.
Article in English | MEDLINE | ID: mdl-32167372

ABSTRACT

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons. Our measurement stands in the long history of EDM experiments probing physics violating time-reversal invariance. The salient features of this experiment were the use of a ^{199}Hg comagnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic-field changes. The statistical analysis was performed on blinded datasets by two separate groups, while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is d_{n}=(0.0±1.1_{stat}±0.2_{sys})×10^{-26} e.cm.

18.
Dis Esophagus ; 33(1)2020 Jan 16.
Article in English | MEDLINE | ID: mdl-31313807

ABSTRACT

The positive impact on patient comprehension and improved procedural outcomes when multimedia is utilized to convey instructions preprocedurally has been previously shown for gastrointestinal procedures such as colonoscopy. However, in gastroesophageal reflux testing (GERD), we continue to utilize verbal and written instructions to establish this diagnosis when we use BRAVO pH testing. This is arguably a more complex procedure involving stopping medications, placement of a device, and maintaining an accurate diary for the duration of the testing. We hypothesize that by utilizing multimedia to relay complex textual information, patients will have improved comprehension of periprocedural instructions thereby improving data entry and satisfaction of expectations during the procedure. Prospective randomized study of 120 patients undergoing endoscopic placement of the BRAVO pH monitoring capsule for evaluation of GERD receive either written preoperative instructions (control) or written plus video instructions (video group). A composite comprehension score was calculated using procedure-specific parameters of data entry over the 48-hour monitoring period. Patient satisfaction was evaluated on the basis of a five-point Likert scale. Extent of patient satisfaction was defined by the fulfillment of patient expectations. Exclusion criteria included patients who did not have access to the video or did not complete follow-up. Seventy-eight patients completed all follow-up evaluations. The video group (n = 44) had a significantly higher mean comprehension score when compared to the control group (n = 34) (9.6 ± 1.4 vs. 7.4 ± 2.0, P = 0.01). Overall satisfaction with instructions was significantly higher in the intervention group (91% vs. 47%, p 0.01). We detected no significant difference in comprehension or satisfaction scores in subgroup analyses of the video group comparing patients <65 and ≥65 years of age and by education level. Compared to standard written instructions, video instructions improved patient comprehension based on data evaluation, and satisfaction. Therefore, clinicians should consider incorporation of multimedia instructions to enhance patient periprocedural expectations and understanding of reflux pH testing using the BRAVO procedure.


Subject(s)
Esophageal pH Monitoring/psychology , Gastroesophageal Reflux/diagnosis , Patient Acceptance of Health Care/psychology , Patient Education as Topic/methods , Patient Satisfaction/statistics & numerical data , Aged , Comprehension , Female , Humans , Male , Middle Aged , Multimedia , Prospective Studies
19.
Hum Exp Toxicol ; 37(4): 343-349, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28425352

ABSTRACT

BACKGROUND: Accidental drug overdose is a common problem in young children. We examined the influence of formulation and dose in enquiries for different gastro-oesophageal reflux disease treatments in children under 5 years to the UK's National Poisons Information Service. METHODS: Overdose characteristics with ranitidine, omeprazole or domperidone were compared with those of metoclopramide and the H-1 antagonist chlorphenamine, for the period 1 July 2007 to 30 June 2015. RESULTS: There were a total of 1092 ranitidine, 618 domperidone and 1193 omeprazole cases; 669, 281 and 424, respectively, were single agent enquiries; of these 77% (517) of ranitidine, 52% (145) domperidone and 32% (135) omeprazole cases occurred in children <5 years. In comparison, 17% (34/424) of metoclopramide and 53% (533/1013) of chlorphenamine were <5 years; 79% (410/517) of ranitidine overdose enquiries in children <5 years were under 6 months of age, higher than domperidone (68/145, 47%; p < 0.05), omeprazole (8/135, 6%), chlorphenamine (13/553, 2%) or metoclopramide (1/34, 3%) (all p < 0.01). In children aged <6 months, 101 were 10-fold overdoses, 86 with ranitidine. CONCLUSIONS: Tenfold overdoses in children (<5 years) were a feature of ranitidine enquiries, likely due to the high concentration of the syrup. This has relevance to other liquid formulations used for non-licenced indications in young children. Such therapeutic errors cause significant carer anxiety and healthcare utilization. Assistance is needed from manufacturers and legislators in modifying formulation so that drugs can be safely used in young children. Education of prescribers and carers is also needed to reduce the incidence of such errors that cause significant carer anxiety and healthcare utilization.


Subject(s)
Drug Overdose/epidemiology , Gastrointestinal Agents/poisoning , Poison Control Centers , Ranitidine/poisoning , Age Factors , Child, Preschool , Chlorpheniramine/administration & dosage , Chlorpheniramine/poisoning , Databases, Factual , Domperidone/administration & dosage , Domperidone/poisoning , Drug Compounding , Drug Overdose/diagnosis , Female , Gastrointestinal Agents/administration & dosage , Humans , Incidence , Infant , Male , Metoclopramide/administration & dosage , Metoclopramide/poisoning , Omeprazole/administration & dosage , Omeprazole/poisoning , Ranitidine/administration & dosage , Risk Factors , United Kingdom/epidemiology
20.
Phys Rev Lett ; 121(24): 242002, 2018 Dec 14.
Article in English | MEDLINE | ID: mdl-30608729

ABSTRACT

We report the first observation of the parity-violating gamma-ray asymmetry A_{γ}^{np} in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. A_{γ}^{np} isolates the ΔI=1, ^{3}S_{1}→^{3}P_{1} component of the weak nucleon-nucleon interaction, which is dominated by pion exchange and can be directly related to a single coupling constant in either the DDH meson exchange model or pionless effective field theory. We measured A_{γ}^{np}=[-3.0±1.4(stat)±0.2(syst)]×10^{-8}, which implies a DDH weak πNN coupling of h_{π}^{1}=[2.6±1.2(stat)±0.2(syst)]×10^{-7} and a pionless EFT constant of C^{^{3}S_{1}→^{3}P_{1}}/C_{0}=[-7.4±3.5(stat)±0.5(syst)]×10^{-11} MeV^{-1}. We describe the experiment, data analysis, systematic uncertainties, and implications of the result.

SELECTION OF CITATIONS
SEARCH DETAIL
...