1.
Front Pediatr ; 10: 957835, 2022.
Article in English | MEDLINE | ID: mdl-36545663

ABSTRACT

Introduction: The study aim was to test the safety and efficacy of a pad with optic fibers developed for monitoring newborn respiratory rate (RR) and heart rate (HR). Methods: Thirty New Zealand White rabbits were included, divided by weight into three groups. RR and HR were measured using two methods for each rabbit: ECG electrodes as the reference method and a newly developed pad with an experimental fiber optic system (EFOS) as the experimental method. Results: Analysis was performed on data for 29 rabbits (10 female, 34%; 19 male, 66%). EFOS performed better at measuring RR compared with HR. RR values did not differ significantly between the methods for the whole group (p = 0.151) or within each sex (female: p > 0.999; male: p = 0.075). Values for HR, however, did differ between methods for the whole group of animals (p < 0.001) and also within groups by sex (female: p < 0.001; male: p = 0.006). Conclusion: The results of this preclinical study demonstrate the potential of this non-invasive method using a fiber optic pad to measure HR and RR.

2.
Sensors (Basel) ; 22(15)2022 Jul 26.
Article in English | MEDLINE | ID: mdl-35898080

ABSTRACT

Currently, all the technology used for seismic monitoring is based on sensors in the electrical domain. There are, however, other physical principles that may enable and fully replace existing devices in the future. This paper introduces one of these approaches, namely the field of fiber optics, which has great potential to be fully applied in the field of vibration measurement. The proposed solution uses a Michelson fiber-optic interferometer designed without polarization fading and with an operationally passive demodulation technique using three mutually phase-shifted optical outputs. Standard instrumentation commonly used in the field of seismic monitoring in geotechnical engineering was used as a reference. Comparative measurements were carried out during the implementation of gravel piles, which represents a significant source of vibration. For the correlation of the data obtained, the linear dependence previously verified in laboratory measurements was used. The presented results show that the correlation is also highly favorable (correlation coefficient in excess of 0.9) from the values measured in situ, with an average deviation for the oscillation velocity amplitude of the optical sensor not exceeding 0.0052.

3.
Sensors (Basel) ; 18(11)2018 Oct 31.
Article in English | MEDLINE | ID: mdl-30384506

ABSTRACT

The publication presents a comparative study of two fibre-optic sensors in the application of heart rate (HR) and respiratory rate (RR) monitoring of the human body. After consultation with clinical practitioners, two types of non-invasive measuring and analysis systems based on fibre Bragg grating (FBG) and fibre-optic interferometer (FOI) have been designed and assembled. These systems use probes (both patent pending) that have been encapsulated in the bio-compatible polydimethylsiloxane (PMDS). The main advantage of PDMS is that it is electrically non-conductive and, as well as optical fibres, has low permeability. The initial verification measurement of the system designed was performed on four subjects in a harsh magnetic resonance (MR) environment under the supervision of a senior radiology assistant. A follow-up comparative study was conducted, upon a consent of twenty volunteers, in a laboratory environment with a minimum motion load and discussed with a head doctor of the Radiodiagnostic Institute. The goal of the laboratory study was to perform measurements that would simulate as closely as possible the environment of harsh MR or the environment of long-term health care facilities, hospitals and clinics. Conventional HR and RR measurement systems based on ECG measurements and changes in the thoracic circumference were used as references. The data acquired was compared by the objective Bland⁻Altman (B⁻A) method and discussed with practitioners. The results obtained confirmed the functionality of the designed probes, both in the case of RR and HR measurements (for both types of B⁻A, more than 95% of the values lie within the ±1.96 SD range), while demonstrating higher accuracy of the interferometric probe (in case of the RR determination, 95.66% for the FOI probe and 95.53% for the FBG probe, in case of the HR determination, 96.22% for the FOI probe and 95.23% for the FBG probe).


Subject(s)
Fiber Optic Technology/instrumentation , Heart Rate/physiology , Interferometry/instrumentation , Magnetic Resonance Imaging , Optical Phenomena , Respiratory Rate/physiology , Adult , Artifacts , Electrocardiography , Female , Human Body , Humans , Male , Middle Aged , Motion , Optical Fibers , Phonocardiography , Signal Processing, Computer-Assisted , Wavelet Analysis , Young Adult