Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Tex Heart Inst J ; 50(5)2023 10 18.
Article in English | MEDLINE | ID: mdl-37867308

ABSTRACT

BACKGROUND: Patient-prosthesis mismatch (PPM) may impair functional capacity and survival after aortic valve replacement. This study aimed to investigate the impact of PPM on long-term survival and quality of life after mechanical and biological aortic valve replacement. METHODS: This study included 595 consecutive patients who had undergone isolated aortic valve replacement. Patients were divided into 2 groups according to prosthesis type. The baseline and operative characteristics, survival rates, complications, and quality of life of the groups with and without PPM were compared for up to 6 years. The PPM calculation was performed using the effective orifice area value provided by the manufacturer divided by the patient's body surface area. RESULTS: The moderate to severe PPM rates were 69.8% and 3.7% after biological and mechanical prosthesis implantation, respectively. Mean survival for patients in the biological group who had PPM was statistically significantly shorter (50.2 months [95% CI, 45.2-55.3]) than for patients in the biological group without PPM (60.1 months [95% CI, 55.7-64.4]; P = .04). In the mechanical prosthesis group, there was no difference in mean survival between the subgroup with PPM (66.6 months [95% CI, 58.3-74.9]) and the subgroup without PPM (64.9 months [95% CI, 62.6-67.2]; P = .50). A quality-of-life questionnaire's scores did not differ between the groups. CONCLUSION: Mismatch is common after biological valve implantation and statistically significantly affects long-term survival and quality of life. If the risk of PPM after implantation of a biological prosthesis is suspected, adopting strategies to avoid PPM at the time of surgery is warranted.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve Stenosis/surgery , Quality of Life , Treatment Outcome , Prosthesis Design , Risk Factors
2.
Heart Surg Forum ; 24(3): E544-E549, 2021 Jun 11.
Article in English | MEDLINE | ID: mdl-34173749

ABSTRACT

BACKGROUND: Heart failure is the most frequent cause of pulmonary artery hypertension (PAH) and its severity may predict the development of heart failure (HF) and is known to be a prognostic factor of poor outcome after heart transplant (HTx). The aim of this study was to investigate the impact of preoperative PAH related to left-sided HF on long-term survival after HTx and to identify the hemodynamic parameters of PAH that predict survival after HTx. METHODS: A prospective observational trial was performed, and it included 44 patients subjected to heart transplantation. Patients were divided into two groups: The first one with the preoperative diagnosis of PAH and the second one without the PAH diagnosed prior to the HTx. The two groups were compared for baseline characteristics, operative characteristics, survival, and hemodynamic parameters obtained by right heart catheterization. Survival was analyzed using Kaplan Meyer analysis, and Cox regression analysis was performed to determine independent predictors of survival. RESULTS: The median follow-up time was 637.4 days (1-2028 days). The median survival within the group of patients with preoperative PAH was 1144 days (95% CI 662.884-1625.116) and 1918.920 days (95% CI 1594.577-2243.263) within the group of patients without PAH (P = .023), HR 0.279 (95% [CI]: 0.086-0.910; P = .034. The 30-day mortality in patients within PAH group was significantly higher, six versus two patients in the non PAH group (χ2 = 5.103, P < .05), while the long-term outcome after this period did not differ between the groups. Patients with preoperative PAH had significantly higher values of MPAP, PCWP, TPG and PVRI, while CO and CI did not differ between the two groups. Mean PVRI was 359.1 ± 97.3 dyn·s·cm-5 in the group with preoperative PAH and 232.2 ± 22.75 dyn·s·cm-5 in the group without PAH, P < .001. TPG values were 11.95 ± 5.08 mmHg in the PAH group while patients without PAH had mean values of 5.16 ± 1.97 mmHg, P < .001. Cox regression analysis was done for the aforementioned parameters. Hazard ratio for worse survival after HTx for elevated values of PVRI was 1.006 (95% [CI]: 1.001-1.012; P = .018) TPG had a hazard ratio of 1.172 (95% [CI]: 1.032-1.233; P = .015). CONCLUSION: Pulmonary artery hypertension is an independent risk factor for higher 30-day mortality after HTx, while it does not affect the long-term outcome. Hemodynamic parameters obtained by right heart catheterization in heart transplant candidates could predict postoperative outcome. PVRI and TPG have been identified as independent predictors of higher 30-day postoperative mortality.


Subject(s)
Heart Failure/surgery , Heart Transplantation/adverse effects , Hypertension, Pulmonary/complications , Postoperative Complications/mortality , Pulmonary Wedge Pressure/physiology , Risk Assessment/methods , Ventricular Function, Right/physiology , Adolescent , Adult , Female , Follow-Up Studies , Heart Failure/complications , Heart Failure/mortality , Humans , Hypertension, Pulmonary/mortality , Hypertension, Pulmonary/physiopathology , Male , Middle Aged , Prospective Studies , Risk Factors , Serbia/epidemiology , Survival Rate/trends , Time Factors , Young Adult
3.
J Card Surg ; 36(2): 629-636, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33403686

ABSTRACT

BACKGROUND: Preoperative use of platelet function tests contributes to the decrease of re-intervention rate due to bleeding and the necessity of transfusion in coronary artery bypass grafting (CABG) patients. The aim was to investigate the predictive value and to justify routine preoperative use of multiple electrode aggregometry in these patients. METHODS: A prospective observational trial which included 416 consecutive patients subjected to elective isolated CABG was conducted. The Multiplate® test was used to assess platelet function. Platelet function test results, postoperative blood loss, and transfusion requirements were compared between high and low bleeding risk patients. Receiver operating characteristic analysis was performed to assess the sensitivity and specificity of the arachidonic acid (ASPI) and adenosine di-phosphate high sensitive (ADPHS) tests. RESULTS: ADPHS and ASPI test results significantly predicted total bleeding > 1000 ml (AUC, 0.685, p < .001; 0.695, p = .039). Sensitivity and specificity were 62.9% and 40.0%, for ADPHS ≤602, and 70.8% and 41.8%, for ASPI ≤ 453. The sensitivity and specificity of cut-off values recommended by the manufacturer were 84.2% and 40.0% for ADPHS ≤ 500, while for ASPI < 600 the values were 54.7% and 62.2%. More platelets and cryoprecipitate were transfused in patients with ADPHS ≤ 602.5 (p < .001; p = .035). Patients with ADPHS ≤ 500 had a higher rate of red blood count, platelet and cryoprecipitate transfusion (p<.001p<.001; p = .013). The manufacturer's ASPI test cut-off values showed no statistically significant prediction for a higher transfusion rate. CONCLUSION: Preoperative platelet function tests should be conducted systematically for all elective CABG patients who were on dual antiplatelet therapy after adjusting test cut-off values for each population.


Subject(s)
Platelet Aggregation Inhibitors , Platelet Function Tests , Blood Platelets , Coronary Artery Bypass , Humans , Platelet Aggregation , Postoperative Hemorrhage/epidemiology
4.
Article in English | MEDLINE | ID: mdl-33049955

ABSTRACT

Aortic valve replacement for aortic stenosis represents one of the most frequent surgical procedures on heart valves. These patients often have concomitant mitral regurgitation. To reveal whether the moderate mitral regurgitation will improve after aortic valve replacement alone, we performed a systematic review and meta-analysis. We identified 27 studies with 4452 patients that underwent aortic valve replacement for aortic stenosis and had co-existent mitral regurgitation. Primary end point was the impact of aortic valve replacement on the concomitant mitral regurgitation. Secondary end points were the analysis of the left ventricle reverse remodeling and long-term survival. Our results showed that there was significant improvement in mitral regurgitation postoperatively (RR, 1.65; 95% CI 1.36-2.00; p < 0.00001) with the average decrease of 0.46 (WMD; 95% CI 0.35-0.57; p < 0.00001). The effect is more pronounced in the elderly population. Perioperative mortality was higher (p < 0.0001) and long-term survival significantly worse (p < 0.00001) in patients that had moderate/severe mitral regurgitation preoperatively. We conclude that after aortic valve replacement alone there are fair chances but for only slight improvement in concomitant mitral regurgitation. The secondary moderate mitral regurgitation should be addressed at the time of aortic valve replacement. A more conservative approach should be followed for elderly and high-risk patients.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged , Aortic Valve/surgery , Humans , Mitral Valve Insufficiency/surgery , Prospective Studies , Retrospective Studies , Treatment Outcome
5.
Heart Surg Forum ; 23(3): E393-E396, 2020 Jun 04.
Article in English | MEDLINE | ID: mdl-32524987

ABSTRACT

We presented surgical treatment of three patients indicated for implantation of a permanent mechanical circulatory support device and with the associated left ventricular aneurysms. In order to evade the left ventricular rupture, adverse thromboembolic events and provide safe implantation of the inflow cannula, LVAD HM3 implantation together with the reconstruction of the left ventricular aneurysmal wall was performed in two patients. Regarding the third patient, LVAD implantation upon the reconstruction of the left ventricular wall was abandoned because there was no safe location for placement of the inflow cannula.


Subject(s)
Cardiac Surgical Procedures/methods , Heart Aneurysm/surgery , Heart Ventricles/diagnostic imaging , Heart-Assist Devices , Echocardiography , Heart Aneurysm/diagnosis , Heart Ventricles/surgery , Humans , Male , Middle Aged , Positron Emission Tomography Computed Tomography , Prosthesis Design
6.
Sci Rep ; 9(1): 8567, 2019 06 12.
Article in English | MEDLINE | ID: mdl-31189989

ABSTRACT

Coronary artery bypass grafting (CABG) remains the most frequent surgery in the practice of an adult cardiac surgeon and the most frequently performed cardiac surgical procedure worldwide. Despite the ongoing debates regarding the superiority or inferiority of off-pump coronary artery bypass grafting, it still comprises 15-30% of all CABG cases varying in different national registries. We performed a propensity matched study of 302 consecutive CABG patients,143 off -pump cases performed by the four experienced off-pump surgeons and the on-pump CABG cases performed by those surgeons and four other experienced coronary surgeons. The five year follow up was performed and data collected comprised of mortality, rehospitalization due to cardiac origin, repeated revascularization, myocardial infarction and cerebrovascular accident. Overall, the off-pump group of patients had a higher risk profile than the patients in the on-pump group. After matching, fewer differences were found between the groups. Propensity score matching analysis showed no difference in long-term survival as well as MACCE and repeated revascularization. The higher risk profile of the patients subjected to OPCAB and the comparable survival to lower risk CPB patients in this series indicate that in experienced hands, OPCAB is a valuable option in this important subgroup of patients.


Subject(s)
Coronary Artery Bypass, Off-Pump , Coronary Artery Disease/mortality , Coronary Artery Disease/surgery , Aged , Disease-Free Survival , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Survival Rate
SELECTION OF CITATIONS
SEARCH DETAIL
...