Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 140
Filter
1.
Article in English | MEDLINE | ID: mdl-38736247

ABSTRACT

BACKGROUND: In transcatheter aortic valve replacement (TAVR), transfemoral (TF) access offers several advantages over alternative access routes. Advances in sheaths and valve delivery technology have catalyzed the feasibility of TF-TAVR, even in challenging anatomies. AIMS: Report procedural characteristics and outcomes of a TAVR program aiming for a 100% TF access rate. METHODS: Consecutive patients undergoing TAVR were enrolled in a prospective registry. Equipment used to facilitate TF-access in challenging anatomies included low-profile sheaths, dilatators, peripheral balloons, covered and uncovered self-expanding and balloon-expandable stents, and intravascular lithotripsy (IVL). RESULTS: A total of 400 patients with a mean age of 81 ± 6 years (42% female) were analyzed. Minimal iliofemoral artery diameter (MLD) of the main access side was <5 mm in 42 (10.5%), extreme tortuosity was present in 65 (16.3%), and severe calcification in 59 (14.8%). TF-access was successful in 399 (99.8%) patients. A transaxillary access was used in one patient. In multivariable analysis, an MLD < 5 mm was the strongest predictor for vascular complications (11.9% vs. 3.9%, OR: 3.86, 95% CI: 1.38-10.8, p = 0.01). Such patients also had more major/life-threatening bleeding (14.2% vs. 3.1%, p < 0.001) and required more planned and unplanned peripheral interventions to enable TF access (35.8% vs. 3.4%, p < 0.001). CONCLUSION: Our study shows that utilization of dedicated sheaths, peripheral balloons, stents, and IVL enables TAVR via TF access in >99% of patients. However, rates of vascular and bleeding complications in patients with narrow iliofemoral arteries (MLD < 5 mm) were high.

3.
Article in English | MEDLINE | ID: mdl-38642291

ABSTRACT

BACKGROUND: Patients with acute myocardial infarction (AMI) and large thrombus burden (LTB) still represent a challenge. Afflicted patients have a high morbidity and mortality. Aspiration thrombectomy is often ineffective in those cases. Mechanical thrombectomy devices (MTDs), which are effective for management of ischemic strokes, were recently CE-approved for treatment of thrombotic coronary lesions. Real-world data about their performance in AMI cases with LTB are scarce. This study sought to summarize our early experience with a novel MTD device in this context. METHODS: We analyzed consecutive patients from the prospective OPTIMISER registry (NCT04988672), who have been managed with the NeVa™ MTD (Vesalio, USA) for AMI with LTB at a tertiary cardiology facility. Outcomes of interest included, among others, periprocedural complications, target lesion failure (TLF), target lesion revascularization (TLR) and target vessel myocardial infarction (TV-MI). RESULTS: Overall, 15 patients underwent thrombectomy with the NeVa™ device. Thrombectomy was successfully performed in 14 (93%) patients. Final TIMI 3 flow was achieved in 13 (87%) patients, while 2 (13%) patients had TIMI 2 flow. We encountered no relevant periprocedural complications, especially no stroke, stent thrombosis or vessel closure. After a mean follow-up time of 26 ± 2.9 months, 1 (7%) patient presented with TLR due to stent thrombosis (10 months after treatment with the MTD and stenting). CONCLUSIONS: In AMI patients with LTB, the deployment of the novel NeVa™ MTD seems efficient and safe. Further randomized trials are warranted to assess whether the use of the NeVa™ device in cases with LTB improves procedural and clinical outcomes.

4.
J Invasive Cardiol ; 36(3)2024 Mar.
Article in English | MEDLINE | ID: mdl-38441987

ABSTRACT

OBJECTIVES: Despite the introduction of improved drug eluting stents (DES), the rate of repeat revascularization procedures following percutaneous coronary interventions (PCI) in coronary chronic total occlusions (CTO) remains high. By leaving vessels uncaged and limiting length of stented segments, drug-coated balloons (DCB) represent an appealing alternative to DES for CTO-PCI. Since data supporting the use of DCBs in CTO-PCI is scarce, we compared the outcomes of patients undergoing CTO-PCI involving DCBs vs DES only. METHODS: From 2 prospective registries, outcomes of patients undergoing CTO-PCI involving DCBs and those undergoing PCI with DES only were compared. Outcomes included major adverse cardiac and cerebrovascular events (MACCE) and cardiovascular death (CV-death). RESULTS: Overall, 157 patients were studied; 112 (71%) underwent CTO-PCI involving DCBs and 45 (29%) were treated with DES only. Mean J-CTO score was 1.84 ± 0.7. Most CTO-lesions involved the right coronary artery, 88 (56%), and 26 (17%) cases were in-stent occlusions. In the DCB group, 46 (41%) lesions were treated with DCBs alone. Mean lengths of the stented segments in the DCB vs DES cohorts were 59 ± 28 mm vs 87 ± 37 mm (P less than .001), respectively. After 12 months, the MACCE rate was higher in the DES only vs DCB group (26% vs 11%, P=.03). Length of the stented segment was an independent predictor for MACCE (HR 1.15 [95% CI, 1.05-1.26] per 10-mm stent length). CONCLUSIONS: Revascularization of CTO lesions involving DCBs appears safe and potentially lowers MACCE rates compared to treatment with DES alone. Importantly, using DCBs for CTO treatment may reduce total stent length, which determines PCI outcomes.


Subject(s)
Chlorobenzenes , Coronary Occlusion , Percutaneous Coronary Intervention , Humans , Coronary Occlusion/diagnosis , Coronary Occlusion/surgery , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Heart , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery
5.
J Invasive Cardiol ; 36(4)2024 Apr.
Article in English | MEDLINE | ID: mdl-38412438

ABSTRACT

OBJECTIVES: Percutaneous closure of a patent foramen ovale (PFO) for the prevention of recurrent paradoxical thromboembolic events has been shown to be safe and effective in randomized controlled trials. However, it remains uncertain if differences in the structure and design of the occluder devices impact the outcomes. The aim of this study was to compare results of percutaneous PFO closure using 2 widely used double-disc occluders. METHODS: Consecutive patients who underwent percutaneous PFO closure with the Abbott Amplatzer occluder (APO) or the Occlutech Figulla-Flex-II occluder (OPO) at the Heart Center Lucerne between February 2017 and December 2022 were included in a registry. The primary endpoint was effective closure of the PFO, defined as a residual shunt grade 0 or 1, assessed by contrast echocardiogram at 6-month follow-up. Secondary endpoints included procedural efficacy/safety and major adverse cardiovascular events during the hospital stay and at 6-month follow-up. RESULTS: One hundred ninety-three consecutive patients (mean age 51.7 ± 12.5 years; 39% women; Risk of Paradoxical Embolism (RoPE) score = 7, IQR = 6-8) underwent percutaneous PFO closure with the APO (120 patients, 62.2%) or the OPO (73 patients, 37.8%). Main indications for closure were crypotogenic stroke in 168 patients (87.1%) and peripheral embolism in 13 patients (6.7%). At baseline, right-to-left shunt (RLS) greater than or equal to grade 2 was present in 189 patients (97.9%). Immediate procedural success was 99.5%. In 1 patient, an air embolism occurred during positioning of the APO occluder with transient chest pain and electrocardiogram changes, but without further sequelae to the patient. At 6-month follow-up, effective closure was achieved in 185 patients (95.8%; APO: 96.6% vs OPO: 94.5%, P = .30). Rates of atrial fibrillation and recurrent thromboembolic events were 4.2 and 0.5%, respectively. CONCLUSIONS: PFO closure is safe and effective when performed with either the self-expanding Abbott Amplatzer or Occlutech Figulla Flex II PFO occluder.


Subject(s)
Foramen Ovale, Patent , Septal Occluder Device , Stroke , Thromboembolism , Humans , Female , Adult , Middle Aged , Male , Foramen Ovale, Patent/diagnosis , Foramen Ovale, Patent/surgery , Foramen Ovale, Patent/complications , Treatment Outcome , Echocardiography , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Septal Occluder Device/adverse effects , Thromboembolism/etiology , Cardiac Catheterization/methods
6.
J Am Heart Assoc ; 13(5): e032250, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38390801

ABSTRACT

BACKGROUND: Chronic inflammatory disease (CID) accelerates atherosclerosis and the development of aortic stenosis. Data on long-term outcomes after transcatheter aortic valve implantation (TAVI) in those patients are missing. The aim of this study was to investigate the clinical long-term outcomes of patients with and without autoimmune-related CID undergoing TAVI for the treatment of severe aortic stenosis. METHODS AND RESULTS: From a prospective registry, consecutive patients with TAVI were included. Baseline clinic and imaging data (echocardiographic and computed tomography) were analyzed. Long-term (up to 5 years) clinical and echocardiographic outcomes were studied. Of 1000 consecutive patients (mean age 81±6 years, 46% female), 107 (11%) had CID; the most frequent entities included polymyalgia rheumatica (31%) and rheumatoid arthritis (28%). Patients with CID were predominantly female (60% versus 44%, P=0.002) and more often had pulmonary disorders (21% versus 13%, P=0.046) and atrial fibrillation (32% versus 20%, P=0.003). The presence of CID was associated with a higher rate of postinterventional infection (5% versus 1%, P=0.007) and further emerged as a risk factor for rehospitalization for bleeding or infection (hazard ratio, 1.93 and 1.62, respectively). Premature valve degeneration, endocarditis, and all-cause mortality were not increased among patients with CID. CONCLUSIONS: This real-world analysis found that patients with CID undergoing TAVI were associated with a higher risk of postinterventional infectious complications and rehospitalization due to infection. However, valve durability and survival seem not to differ between patients with TAVI with versus without CID.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Risk Factors , Atrial Fibrillation/complications , Chronic Disease , Registries
7.
Front Cardiovasc Med ; 11: 1316580, 2024.
Article in English | MEDLINE | ID: mdl-38414923

ABSTRACT

Background: There is mounting data supporting the use of drug-coated balloons (DCB) not only for treatment of in-stent restenosis (ISR), but also in native coronary artery disease. So far, paclitaxel-coated balloons represented the mainstay DCBs. The SeQuent® crystalline sirolimus-coated balloon (SCB) (B.Braun Medical Inc, Germany) represents a novel DCB, which allows a sustained release of the limus-drug. We evaluated its performance in an all-comer cohort, including complex coronary lesions. Methods: Consecutive patients treated with the SeQuent® SCB were analyzed from the prospective SIROOP registry (NCT04988685). We assessed clinical outcomes, including major adverse cardiovascular events (MACE), target lesion revascularization (TLR), target vessel myocardial infarction (TV-MI) and cardiovascular death. Angiograms and outcomes were independently adjudicated. Results: From March 2021 to March 2023, we enrolled 126 patients and lesions, of which 100 (79%) treated using a "DCB-only" strategy and 26 (21%) with a hybrid approach (DES + DCB). The mean age was 68 ± 10 years, 48 (38%) patients had an acute coronary syndrome. Regarding lesion characteristics, ISR was treated in 27 (21%), 11 (9%) underwent CTO-PCI and 59 (47%) of the vessels were moderate to severe calcified. Procedural success rate was 100%. At a median follow-up time of 12.7 (IQR 12; 14.2) months, MACE occurred in 5 patients (4.3%). No acute vessel closure was observed. Conclusions: Our data indicates promising outcomes following treatment with this novel crystalline SCB in an all-comer cohort with complex coronary lesions. These results require further investigation with randomized trials.

8.
Eur J Intern Med ; 2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38238134

ABSTRACT

Inflammation plays a central role in coronary artery disease (CAD), and recent data have shown that anti-inflammatory drugs have the potential to reduce ischemic events in CAD patients. Colchicine is an ancient anti-inflammatory drug that targets neutrophil and inflammasome activities. It has been prescribed for decades for different rheumatological conditions. Given the important role of inflammation in the development of cardiovascular disease, there has been considerable interest in studying colchicine's potential to limit the progression of atherosclerosis among afflicted patients. In fact, there is a growing body of randomized data suggesting that use of low-dose colchicine reduces the risk of ischemic events in patients with CAD, particularly repeated revascularizations, new myocardial infarctions and strokes. This review article summarizes background information-including possible side effects and contraindications-as well as the current evidence backing up the use of colchicine in patients with established CAD.

9.
Struct Heart ; 7(6): 100214, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38046862

ABSTRACT

Background: Motion artifacts in planning computed tomography (CT) for transcatheter aortic valve implantation (TAVI) can potentially skew measurements required for procedural planning. Whether such artifacts may affect safety or efficacy has not been studied. Methods: We conducted a retrospective analysis of 852 consecutive patients (mean age, 82 years; 47% women) undergoing TAVI-planning CT at a tertiary care center. Two independent observers divided CTs according to the presence of motion artifacts at the annulus level (Motion vs. Normal group). Endpoints included surrogate markers for inappropriate valve selection: annular rupture, valve embolization or misplacement, need for a new permanent pacemaker, paravalvular leak (PVL), postprocedural transvalvular gradient, all-cause death. Results: Forty-six (5.4%) patients presented motion artifacts on TAVI-planning CT (Motion group). These patients had more preexisting heart failure, moderate-severe mitral regurgitation, and atrial fibrillation. Interobserver variability of annular measurement (Normal vs. Motion group) did not differ for mean annular diameter but was significantly different for perimeter and area. Presence of motion artifacts on planning CT did not affect the prevalence of PVL (≥moderate PVL 0% vs. 2.5% p = 0.5), mean transvalvular gradient (6±3 mmHg vs 7±5 mmHg, p = 0.1), or the need for additional valve implantation (0% vs. 2.8%, p = 0.6). One annular rupture occurred (Normal group). Pacemaker implantation, procedural duration, hospital stay, 30-day outcomes, and all-cause mortality did not differ between the groups. Conclusions: Motion artifacts on planning CT were found in about 5% of patients. Measurements for valve selection were possible without the need for repeat CT, with mean diameter-derived annulus measurement being the most accurate. Motion artifacts were not associated with worse outcomes.

10.
J Invasive Cardiol ; 35(12)2023 Dec.
Article in English | MEDLINE | ID: mdl-38108869

ABSTRACT

OBJECTIVES: The Allegra-THV is a novel, self-expanding THV with supra-annular bovine leaflets. The valve is available in 3 different sizes and is delivered through an 18 French sheath. To determine the safety and efficacy of the Allegra transcatheter heart valve (THV; Biosensors) for the treatment of severe aortic valve stenosis under real-world conditions. METHODS: Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) at the Heart-Centre Lucerne with the Allegra-THV were included. Echocardiographic data were collected at baseline, before discharge, and at 1-year follow-up; clinical outcomes were recorded for up to 3 years. Clinical endpoints were defined according to the definitions of the Valve-Academic-Research-Consortium. RESULTS: One hundred-three patients (age 81 ± 7 years, 63% women) were enrolled. Median European System for Cardiac Operative Risk Evaluation II score was 4.1% (IQR 1.8%-4.2%). Mean aortic valve gradient was 6.9 ± 3.3 mm Hg and 7.7 ± 3.3 mm Hg, and an effective orifice area was 2.1 ± 0.5 cm2 and 2.0 ± 0.5 cm2 at 30 days and 1-year follow-up, respectively. More than mild paravalvular leak was observed in 2.0% of patients at 30 days and 3.3% at 1 year. At 1-year follow-up, 14.7% of patients required implantation of a new permanent pacemaker, 1 patient had endocarditis with an uneventful clinical course and good THV-function after antibiotic therapy, and no thrombosis, structural-valve-detoriation (SVD), or non-SVD had occurred. At 3-year follow-up, rates of all-cause and cardiovascular mortality were 31.4% and 18.8%, respectively. CONCLUSIONS: Transfemoral implantation of the Allegra-THV resulted in favorable clinical and echocardiographic outcomes at up to 3-year follow-up. Head-to-head randomized clinical trials are necessary to determine if the Allegra-THV valve performs as well as current generation valves.


Subject(s)
Echocardiography , Heart Valves , Humans , Animals , Cattle , Female , Aged , Aged, 80 and over , Male , Terfenadine , Catheters
11.
BMC Cardiovasc Disord ; 23(1): 506, 2023 10 12.
Article in English | MEDLINE | ID: mdl-37828421

ABSTRACT

OBJECTIVES: It is uncertain, if omitting post-dilatation and stent oversizing (stent optimization) is safe and may decrease the risk for distal thrombus embolization (DTE) in STEMI patients with large thrombus burden (LTB). BACKGROUND: In patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (pPCI) with stenting, (DTE) and flow deterioration are common and increase infarct size leading to worse outcomes. METHODS: From a prospective registry, 74 consecutive STEMI patients with LTB undergoing pPCI with stenting and intentionally deferred stent optimization were analyzed. Imaging data and outcomes up to 2 years follow-up were analyzed. RESULTS: Overall, 74 patients (18% females) underwent deferred stent optimization. Direct stenting was performed in 13 (18%) patients. No major complications occurred during pPCI. Staged stent optimization was performed after a median of 4 (interquartile range (IQR) 3; 7) days. On optical coherence tomography, under-expansion and residual thrombus were present in 59 (80%) and 27 (36%) cases, respectively. During deferred stent optimization, we encountered no case of flow deterioration (slow or no-reflow) or side branch occlusion. Minimal lumen area (mm2) and stent expansion (%) were corrected from 4.87±1.86mm to 6.82±2.36mm (p<0.05) and from 69±18% to 91±12% (p<0.001), respectively. During follow-up, 1 patient (1.4%) required target lesion revascularization and 1 (1.4%) patient succumbed from cardiovascular death. CONCLUSIONS: Among STEMI patients with LTB, deferring stent optimization in the setting of pPCI appears safe and potentially mitigates the risk of DTE. The impact of this approach on infarct size and clinical outcomes warrants further investigation in a dedicated trial.


Subject(s)
Coronary Thrombosis , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Female , Humans , Male , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/therapy , ST Elevation Myocardial Infarction/etiology , Prospective Studies , Treatment Outcome , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/etiology , Coronary Thrombosis/therapy , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Stents , Coronary Angiography/methods
12.
Lancet ; 402(10416): 1979-1990, 2023 11 25.
Article in English | MEDLINE | ID: mdl-37898137

ABSTRACT

BACKGROUND: Biodegradable polymer sirolimus-eluting stents improve early stent-related clinical outcomes compared to durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The long-term advantages of biodegradable polymer sirolimus-eluting stents after complete degradation of its polymer coating in patients with STEMI remains however uncertain. METHODS: BIOSTEMI Extended Survival (BIOSTEMI ES) was an investigator-initiated, follow-up extension study of the BIOSTEMI prospective, multicentre, single-blind, randomised superiority trial that compared biodegradable polymer sirolimus-eluting stents with durable polymer everolimus-eluting stents in patients with STEMI undergoing primary percutaneous coronary intervention at ten hospitals in Switzerland. All individuals who had provided written informed consent for participation in the BIOSTEMI trial were eligible for this follow-up study. The primary endpoint was target lesion failure, defined as a composite of cardiac death, target vessel myocardial re-infarction, or clinically indicated target lesion revascularisation, at 5 years. Superiority of biodegradable polymer sirolimus-eluting stents over durable polymer everolimus-eluting stents was declared if the Bayesian posterior probability for a rate ratio (RR) of less than 1 was greater than 0·975. Analyses were performed according to the intention-to-treat principle. The study was registered with ClinicalTrials.gov, NCT05484310. FINDINGS: Between April 26, 2016, and March 9, 2018, 1300 patients with STEMI (1622 lesions) were randomly allocated in a 1:1 ratio to treatment with biodegradable polymer sirolimus-eluting stents (649 patients, 816 lesions) or durable polymer everolimus-eluting stents (651 patients, 806 lesions). At 5 years, the primary composite endpoint of target lesion failure occurred in 50 (8%) patients treated with biodegradable polymer sirolimus-eluting stents and in 72 (11%) patients treated with durable polymer everolimus-eluting stents (difference of -3%; RR 0·70, 95% Bayesian credible interval 0·51-0·95; Bayesian posterior probability for superiority 0·988). INTERPRETATION: In patients undergoing primary percutaneous coronary intervention for STEMI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 5 years of follow-up. The difference was driven by a numerically lower risk for ischaemia-driven target lesion revascularisation. FUNDING: Biotronik.


Subject(s)
Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Sirolimus/therapeutic use , Everolimus/therapeutic use , Follow-Up Studies , ST Elevation Myocardial Infarction/surgery , ST Elevation Myocardial Infarction/drug therapy , Polymers , Bayes Theorem , Single-Blind Method , Prospective Studies , Treatment Outcome , Absorbable Implants , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/methods
13.
Eur Heart J Case Rep ; 7(9): ytad455, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37743902

ABSTRACT

Background: Reducing venous drainage of the coronary sinus is a promising intervention for refractory angina. Coronary Sinus Reducer (CSR) System™ effectively treats patients with refractory angina, possibly by increasing coronary collateral circulation, and leads to an improvement in their symptoms and quality of life. In patients with impaired left ventricular function and electrocardiographic dyssynchrony, cardiac resynchronization therapy (CRT) is an established treatment. However, there is only one published case report of CRT in a patient implanted with a CSR system. We present the first case series of CRT in patients implanted with the CSR system. Case summary: This case series describes three patients. The first case demonstrated that CRT is feasible in patients implanted with a CSR system. The second case is the first report of a left ventricular lead extraction after CSR, and the third case was complicated due to the patient's medical history; however, CSR system implantation was feasible without major complications. Discussion: Our results suggest that CRT is feasible in patients implanted with a CSR system, and lead extraction after CSR system implantation is possible. However, lead extraction in cases of severe adhesions around the CSR system and the coronary sinus may be associated with a high risk of complications; alternative options should be discussed at an early stage.

14.
Eur J Heart Fail ; 25(12): 2299-2311, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37522520

ABSTRACT

AIMS: Takotsubo syndrome (TTS) is associated with a substantial rate of adverse events. We sought to design a machine learning (ML)-based model to predict the risk of in-hospital death and to perform a clustering of TTS patients to identify different risk profiles. METHODS AND RESULTS: A ridge logistic regression-based ML model for predicting in-hospital death was developed on 3482 TTS patients from the International Takotsubo (InterTAK) Registry, randomly split in a train and an internal validation cohort (75% and 25% of the sample size, respectively) and evaluated in an external validation cohort (1037 patients). Thirty-one clinically relevant variables were included in the prediction model. Model performance represented the primary endpoint and was assessed according to area under the curve (AUC), sensitivity and specificity. As secondary endpoint, a K-medoids clustering algorithm was designed to stratify patients into phenotypic groups based on the 10 most relevant features emerging from the main model. The overall incidence of in-hospital death was 5.2%. The InterTAK-ML model showed an AUC of 0.89 (0.85-0.92), a sensitivity of 0.85 (0.78-0.95) and a specificity of 0.76 (0.74-0.79) in the internal validation cohort and an AUC of 0.82 (0.73-0.91), a sensitivity of 0.74 (0.61-0.87) and a specificity of 0.79 (0.77-0.81) in the external cohort for in-hospital death prediction. By exploiting the 10 variables showing the highest feature importance, TTS patients were clustered into six groups associated with different risks of in-hospital death (28.8% vs. 15.5% vs. 5.4% vs. 1.0.8% vs. 0.5%) which were consistent also in the external cohort. CONCLUSION: A ML-based approach for the identification of TTS patients at risk of adverse short-term prognosis is feasible and effective. The InterTAK-ML model showed unprecedented discriminative capability for the prediction of in-hospital death.


Subject(s)
Heart Failure , Takotsubo Cardiomyopathy , Humans , Hospital Mortality , Takotsubo Cardiomyopathy/diagnosis , Takotsubo Cardiomyopathy/complications , Heart Failure/complications , Prognosis , Machine Learning
15.
Clin Res Cardiol ; 2023 Jul 26.
Article in English | MEDLINE | ID: mdl-37495797

ABSTRACT

BACKGROUND AND OBJECTIVES: Recent data have established non-inferiority of drug-coated balloons (DCB) compared to drug-eluting stents (DES) for treatment of small-vessel coronary artery disease. Since coronary vessels in women might have anatomical and pathophysiological particularities, the safety of the DCB strategy among women compared to men needs to be assessed in more detail. METHODS: In BASKET-SMALL 2, patients with de novo lesions in coronary vessels < 3 mm and an indication for percutaneous coronary intervention were randomly allocated (1:1) to DCB vs. DES after successful lesion preparation. The primary objective of the randomized trial was to establish non-inferiority of DCB vs. DES regarding major adverse cardiac events (MACE; i.e., cardiac death, non-fatal myocardial infarction, and target vessel revascularization) after 12 months. The aim of the current sub-analysis is to evaluate whether the DCB strategy is equally safe among women and men after 12 and 36 months. RESULTS: Among 758 randomized patients, 382 were assigned to DCB (23% women) and 376 to DES (30% women). In general, women were older, had more often diabetes mellitus and renal insufficiency, and presented more often with an acute coronary syndrome, whereas men were more often smokers, had multivessel disease and a previous history of acute myocardial infarction, and received a treatment with a statin. After 3 years, the primary clinical end point was not significantly different between groups (13% women vs. 16% men, HR 0.82; 95% CI 0.52-1.30; p = 0.40). There was no interaction between sex and coronary intervention strategy regarding MACE at 36 months (10% women vs. 16% men in DCB, 16% women vs. 15% men in DES; pinteraction = 0.31). CONCLUSION: In small native coronary artery disease, there was no statistically significant effect of sex on the difference between DCB and DES regarding MACE up to 36 months. CLINICAL TRIAL REGISTRATION: URL: http://www. CLINICALTRIALS: gov . Unique identifier: NCT01574534. CAD coronary artery disease, MACE major adverse cardiovascular events, HR Hazard ratio, DCB drug-coated balloon, DES drug-eluting stent.

18.
Am J Cardiol ; 200: 146-152, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37321028

ABSTRACT

Subclinical leaflet thrombosis, identified as hypoattenuated leaflet thickening (HALT) on cardiac computed tomography scan, has been observed after transcatheter aortic valve replacement (TAVR). However, data on HALT after the implant of the supra-annular ACURATE neo/neo2 prosthesis are limited. This study aimed to determine the prevalence and risk factors for the development of HALT after TAVR with the ACURATE neo/neo2. A total of 50 patients who received the ACURATE neo/neo2 prosthesis were prospectively enrolled. Patients underwent a contrast-enhanced multidetector row cardiac computed tomography scan at before, after, and 6 months after TAVR. At the 6-month follow-up, HALT was detected in 16% (8 of 50 patients). These patients had a lower implant depth of the transcatheter heart valve (8 ± 2 mm vs 5 ± 2 mm, p = 0.001), less calcified native valve leaflets, a better expansion of the frame at the level of the left ventricular outflow tract, and were less often hypertensive. Thrombosis of the sinus of Valsalva occurred in 18% (9/50). There was no difference in the anticoagulation regimen between patients with and without thrombotic findings. In conclusion, HALT was present in 16% of patients at 6 months follow-up, patients presenting with HALT had a lower implant depth of the transcatheter heart valve, and HALT was detected in patients on oral anticoagulation therapy.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Prosthesis Design , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Thrombosis/etiology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology
19.
Catheter Cardiovasc Interv ; 102(2): 339-347, 2023 08.
Article in English | MEDLINE | ID: mdl-37232417

ABSTRACT

BACKGROUND: Growing interest in neuroprotection in transcatheter aortic valve replacement (TAVR) has catalyzed the development of cerebral protection systems (CPS). OBJECTIVES: Report insights from consecutive real-world patients undergoing TAVR with the Sentinel-CPS. METHODS: Patients with severe aortic stenosis undergoing TAVR from April 2019 to May 2022 were enrolled in a prospective registry. The reason for unsuccessful Sentinel-CPS deployment and the amount of debris captured by the filters were prospectively recorded. RESULTS: The Sentinal CPS was successfully deployed in 330 patients (85%, Group 1). Deployment was not attempted, unsuccessful or only partially successful in 59 patients (15%, Group 2), caused by anatomical factors such as tortuosity, heavy calcification or small dimensions of radial or brachial artery in 46, technical aspects such as puncture failure or dissection in 5 or use of right radial access for the pigtail in 6. Debris was captured in 98% of patients in Group 1. In 40%, the amount of debris was graded moderate or extensive. Predictors for moderate/extensive debris were moderate/severe aortic calcification (OR 1.50, CI 1.05-2.15, p = 0.03), pre- and postdilatation (OR 1.97, CI 1.02-3.79, p = 0.04 and OR 1.71, CI 1.01-2.89, p = 0.048). The risk of stroke was numerically lower in patients who underwent TAVR with the Sentinel CPS (2.1 vs. 5.1%, respectively, p = 0.15). There was no stroke during CPS deployment, but one patient had a stroke immediately after device retrieval. CONCLUSIONS: The Sentinel-CPS was successfully deployed in 85% of patients. Predictors for moderate/extensive debris captured were moderate/severe aortic calcification, pre- and postdilatation.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Stroke , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome , Stroke/etiology , Risk Factors
20.
BMC Cardiovasc Disord ; 23(1): 176, 2023 03 31.
Article in English | MEDLINE | ID: mdl-37003986

ABSTRACT

BACKGROUND: A decade ago, the iopromide-paclitaxel coated balloon (iPCB) was added to the cardiologist's toolbox to initially treat in-stent restenosis followed by the treatment of de novo coronary lesions. In the meantime, DES technologies have been substantially improved to address in-stent restenosis and thrombosis, and shortened anti-platelet therapy. Recently, sirolimus-coated balloon catheters (SCB) have emerged to provide an alternative drug to combat restenosis. METHODS: The objective of this study is to determine the safety and efficacy of a novel crystalline sirolimus-coated balloon (cSCB) technology in an unselective, international, large-scale patient population. Percutaneous coronary interventions of native stenosis, in-stent stenosis, and chronic total occlusions with the SCB in patients with stable coronary artery disease or acute coronary syndrome were included. The primary outcome variable is the target lesion failure (TLF) rate at 12 months, defined as the composite rate of target vessel myocardial infarction (TV-MI), cardiac death or ischemia-driven target lesion revascularization (TLR). The secondary outcome variables include TLF at 24 months, ischemia driven TLR at 12 and 24 months and all-cause death, cardiac death at 12 and 24 months. DISCUSSION: Since there is a wealth of patient-based all-comers data for iPCB available for this study, a propensity-score matched analysis is planned to compare cSCB and iPCB for the treatment of de novo and different types of ISR. In addition, pre-specified analyses in challenging lesion subsets such as chronic total occlusions will provide evidence whether the two balloon coating technologies differ in their clinical benefit for the patient. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier: NCT04470934.


Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Coronary Restenosis , Drug-Eluting Stents , Humans , Angioplasty/adverse effects , Cardiovascular Agents/adverse effects , Constriction, Pathologic/complications , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Drug-Eluting Stents/adverse effects , Paclitaxel/adverse effects , Sirolimus/adverse effects , Treatment Outcome , Clinical Trials as Topic
SELECTION OF CITATIONS