Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Crit Care ; 26(1): 49, 2022 02 21.
Article in English | MEDLINE | ID: mdl-35189930

ABSTRACT

BACKGROUND: Trauma-induced coagulopathy includes thrombocytopenia and platelet dysfunction that impact patient outcome. Nevertheless, the role of platelet transfusion remains poorly defined. The aim of the study was 1/ to evaluate the impact of early platelet transfusion on 24-h all-cause mortality and 2/ to describe platelet count at admission (PCA) and its relationship with trauma severity and outcome. METHODS: Observational study carried out on a multicentre prospective trauma registry. All adult trauma patients directly admitted in participating trauma centres between May 2011 and June 2019 were included. Severe haemorrhage was defined as ≥ 4 red blood cell units within 6 h and/or death from exsanguination. The impact of PCA and early platelet transfusion (i.e. within the first 6 h) on 24-h all-cause mortality was assessed using uni- and multivariate logistic regression. RESULTS: Among the 19,596 included patients, PCA (229 G/L [189,271]) was associated with coagulopathy, traumatic burden, shock and bleeding severity. In a logistic regression model, 24-h all-cause mortality increased by 37% for every 50 G/L decrease in platelet count (OR 0.63 95% CI 0.57-0.70; p < 0.001). Regarding patients with severe hemorrhage, platelets were transfused early for 36% of patients. Early platelet transfusion was associated with a decrease in 24-h all-cause mortality (versus no or late platelets): OR 0.52 (95% CI 0.34-0.79; p < 0.05). CONCLUSIONS: PCA, although mainly in normal range, was associated with trauma severity and coagulopathy and was predictive of bleeding intensity and outcome. Early platelet transfusion within 6 h was associated with a decrease in mortality in patients with severe hemorrhage. Future studies are needed to determine which doses of platelet transfusion will improve outcomes after major trauma.


Subject(s)
Blood Coagulation Disorders , Thrombocytopenia , Blood Coagulation Disorders/etiology , Hemorrhage/etiology , Hemorrhage/therapy , Humans , Platelet Transfusion/adverse effects , Thrombocytopenia/etiology , Thrombocytopenia/therapy , Trauma Centers
2.
Space Sci Rev ; 216(8): 137, 2020.
Article in English | MEDLINE | ID: mdl-33268910

ABSTRACT

The Mars 2020 Perseverance rover is equipped with a next-generation engineering camera imaging system that represents an upgrade over previous Mars rover missions. These upgrades will improve the operational capabilities of the rover with an emphasis on drive planning, robotic arm operation, instrument operations, sample caching activities, and documentation of key events during entry, descent, and landing (EDL). There are a total of 16 cameras in the Perseverance engineering imaging system, including 9 cameras for surface operations and 7 cameras for EDL documentation. There are 3 types of cameras designed for surface operations: Navigation cameras (Navcams, quantity 2), Hazard Avoidance Cameras (Hazcams, quantity 6), and Cachecam (quantity 1). The Navcams will acquire color stereo images of the surface with a 96 ∘ × 73 ∘ field of view at 0.33 mrad/pixel. The Hazcams will acquire color stereo images of the surface with a 136 ∘ × 102 ∘ at 0.46 mrad/pixel. The Cachecam, a new camera type, will acquire images of Martian material inside the sample tubes during caching operations at a spatial scale of 12.5 microns/pixel. There are 5 types of EDL documentation cameras: The Parachute Uplook Cameras (PUCs, quantity 3), the Descent stage Downlook Camera (DDC, quantity 1), the Rover Uplook Camera (RUC, quantity 1), the Rover Descent Camera (RDC, quantity 1), and the Lander Vision System (LVS) Camera (LCAM, quantity 1). The PUCs are mounted on the parachute support structure and will acquire video of the parachute deployment event as part of a system to characterize parachute performance. The DDC is attached to the descent stage and pointed downward, it will characterize vehicle dynamics by capturing video of the rover as it descends from the skycrane. The rover-mounted RUC, attached to the rover and looking upward, will capture similar video of the skycrane from the vantage point of the rover and will also acquire video of the descent stage flyaway event. The RDC, attached to the rover and looking downward, will document plume dynamics by imaging the Martian surface before, during, and after rover touchdown. The LCAM, mounted to the bottom of the rover chassis and pointed downward, will acquire 90 ∘ × 90 ∘ FOV images during the parachute descent phase of EDL as input to an onboard map localization by the Lander Vision System (LVS). The rover also carries a microphone, mounted externally on the rover chassis, to capture acoustic signatures during and after EDL. The Perseverance rover launched from Earth on July 30th, 2020, and touchdown on Mars is scheduled for February 18th, 2021.

3.
Rev Sci Instrum ; 89(10): 10F113, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399895

ABSTRACT

The Aerogel Cherenkov Detector for Cygnus (ACD/C) is a time-dependent, x-ray spectral detector that uses SiO2 aerogels spanning an index of refraction (n = 1.02-1.07) corresponding to a 1.1-2.3 MeV x-ray energy threshold. The ACD/C was developed for pulsed power x-ray sources like Cygnus located at the Nevada National Site and Mercury located at the Naval Research Laboratory (NRL). Aerogels sit between the measurement capabilities of gas (>2 MeV) and solids such as fused silica (>0.3 MeV). The detector uses an aluminum converter to Compton scatter incoming x-rays and create relativistic electrons, which produce Cherenkov light in an aerogel or a fused silica medium. The ACD/C was fielded at the NRL when Mercury was tuned to produce up to 4.8 MeV endpoint bremsstrahlung. Despite a high radiation and electromagnetic interference background, the ACD/C was able to achieve high signal over noise across five aerogel densities and fused silica, including a signal to noise for a 1.1 MeV aerogel threshold. Previous experiments at Cygnus observed a signal that was comparable to the noise (1×) at the same threshold. The ACD/C observed time-resolved rise and fall times for different energy thresholds of the photon spectrum. Monte Carlo simulations of the ACD/C's aerogel response curves were folded with a simulation of Mercury's photon energy spectrum and agree within the error to the observed result.

4.
J Clin Psychopharmacol ; 17(5): 350-7, 1997 Oct.
Article in English | MEDLINE | ID: mdl-9315985

ABSTRACT

Many antidepressant agents interfere with sexual function. The purpose of this single-blind, prospective study was to determine sexual side effects, both positive and negative, of the amino-ketone antidepressant bupropion in a group of nondepressed diabetic men with somatic erectile dysfunction. Fourteen men participated in a 10-week protocol consisting sequentially of 2 weeks of baseline testing, 2 weeks of placebo, and 6 weeks of bupropion. Participants also completed daily and weekly questionnaires concerning sexual functioning, and a team of investigators rated various dimensions of sexual function every 2 weeks. In addition, a variety of physiologic measures, relevant either to erectile function or to neural/vascular systems that underlie sexual response, were assessed during baseline and bupropion treatment. Results indicated that neither subjective nor objective measures of erectile and overall sexual functioning worsened during bupropion. In fact, several measures suggested a trend toward improved sexual functioning. Furthermore, diabetic control was unaffected by bupropion administration. Given the lack of adverse effects on sexual function, along with the potential for improved erectile response, bupropion may provide an attractive choice for the treatment of depression in diabetic men or others for whom sexual dysfunction is a concern.


Subject(s)
Antidepressive Agents, Second-Generation/pharmacology , Bupropion/pharmacology , Diabetic Angiopathies/physiopathology , Diabetic Neuropathies/physiopathology , Erectile Dysfunction/physiopathology , Impotence, Vasculogenic/physiopathology , Libido/drug effects , Penile Erection/drug effects , Adult , Dose-Response Relationship, Drug , Drug Administration Schedule , Humans , Libido/physiology , Male , Middle Aged , Penile Erection/physiology , Prospective Studies , Single-Blind Method
5.
J Reprod Fertil ; 48(1): 209-11, 1976 Sep.
Article in English | MEDLINE | ID: mdl-966227

ABSTRACT

Progesterone and oestrone alone or in combination were administered to sows during early gestation. A dose of 25 mg progesterone and 12-5 mug oestrone injected together for 10,5 or 2 consecutive days during the implantation interval caused increased litter size at term.


Subject(s)
Estrone/pharmacology , Litter Size/drug effects , Progesterone/pharmacology , Swine/physiology , Animals , Female , Pregnancy , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...