Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters











Publication year range
1.
Front Cardiovasc Med ; 11: 1417074, 2024.
Article in English | MEDLINE | ID: mdl-39139751

ABSTRACT

A 49-year-old female patient, asymptomatic, presented to the cardiology office for a right atrial mass, identified incidentally in a non-electrocardiogram (ECG)-gated contrast-enhanced computed tomography, performed for follow-up of pulmonary tuberculosis. Echocardiography, surprisingly, showed an anechogenic ovoid mass in the right atrium measuring 40 × 40 mm2, implanted in the interatrial septum without affecting the tricuspid valve. ECG-gated computed tomography angiography (CTA), confirmed the dimensions of the mass, which presented homogeneous content, calcified areas, and a 12-mm pedicle implanted near the ostium of the coronary sinus. Additionally, contrast uptake and infiltration of adjacent structures were ruled out. In the surgical field, an encapsulated mass with blood content was found, which pathology reported as a hematic endocardial cyst (HEC). These are rare cardiac masses, constituting 1.5% of all primary cardiac tumors. It is usually an incidental finding, and its clinical presentation will depend on its dimensions and the intracardiac hemodynamic impact. A highlighting feature is its anechogenic content on ultrasound, however, multimodality imaging allows for making diagnostic assumptions, discerning between primary cardiac tumors, and provides morphological and hemodynamic information useful for therapeutic decision making. The age of the patient, the large size of the HEC, and its location in the interatrial septum make up a completely atypical presentation of this rare disease, which motivated this report.

2.
Article in English | MEDLINE | ID: mdl-39015195

ABSTRACT

Aortic stenosis is associated with aortic plaques in up to 85% of cases because they share risk factors and pathogenic pathways. Intrinsically, complex aortic plaques carry a high risk of stroke, which has also been demonstrated in the context of aortic stenosis, especially in patients who underwent percutaneous or surgical replacement. Transesophageal echocardiography (TEE) is the imaging test of choice to detect plaques in the thoracic aorta and classify them as complex plaques. Furthermore, the 3D modality allows us to better specify its dimensions and anatomical characteristics, such as added thrombi or the presence of ulcers inside. This review aims to evaluate the use of TEE to detect complex aortic plaques in patients with an indication for percutaneous or surgical aortic valve replacement. To highlight the association between aortic stenosis and complex aortic plaques, we attached to the review some TEE studies from our experience.


La estenosis aórtica se asocia con placas aórticas hasta en un 85% de los casos, porque comparten factores de riesgo y vías patogénicas. Intrínsecamente, las placas aórticas complejas conllevan un alto riesgo de accidente cerebrovascular, lo que también se ha demostrado en el contexto de estenosis aórtica, especialmente en pacientes sometidos a reemplazo percutáneo o quirúrgico. La ecocardiografía transesofágica (ETE) es la prueba de imagen de elección para detectar placas en la aorta torácica y clasificarlas como placas complejas. Además, la modalidad 3D nos permite precisar mejor sus dimensiones y características anatómicas como trombos añadidos o la presencia de úlceras en su interior. Esta revisión tiene como objetivo evaluar el uso de ETE para detectar placas aórticas complejas en pacientes con indicación de reemplazo valvular aórtico percutáneo o quirúrgico. Para resaltar la asociación de estenosis aórtica y placas aórticas complejas adjuntamos a la revisión algunos estudios de ETE de nuestra experiencia.

3.
Article in English | MEDLINE | ID: mdl-38596609

ABSTRACT

We present the case of a 56-year-old patient with fever of unknown origin associated with chest and lumbar pain. Multimodality imaging revealed diffuse peri-aortitis in the thoracic aorta without involvement of the aortic valve, contributing substantially to the diagnosis of Ig G4-associated aortitis. Immunosuppressive therapy was started. Follow-up at five months with cardiac magnetic resonance imaging showed a reduction in the inflammatory process in the thoracic aorta.


Presentamos el caso de un paciente de 56 años, con cuadro febril de origen desconocido asociado a dolor torácico y lumbar. La imagen multimodal demostró periaortitis difusa en la aorta torácica sin afectación de la válvula aórtica, lo que contribuyó sustancialmente al diagnóstico de aortitis asociada a Ig4. Se inició tratamiento inmunosupresor. El seguimiento a los 5 meses, la resonancia magnética cardíaca mostró una reducción del proceso inflamatorio en la aorta torácica.

4.
Echocardiography ; 41(2): e15757, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38411212

ABSTRACT

Heart masses, including tumors (primary and secondary) and pseudotumor (cysts and thrombus), are rare entities, but of increasing interest in cardiac imaging areas. The clinical manifestations are related to the intracardiac effect of mass, embolization, and systemic symptoms in the case of tumors; however, some of them are detected incidentally. Nowadays, imaging techniques and the advancement of their tools perform the morphological, functional, and tissue characterization of the masses, and additionally know the anatomical relationships, which are crucial factors for the treatment and surgical planning.


Subject(s)
Heart Neoplasms , Humans , Heart Neoplasms/surgery , Echocardiography/methods , Magnetic Resonance Imaging/methods , Radiography , Heart
5.
Arch Peru Cardiol Cir Cardiovasc ; 4(3): 109-113, 2023.
Article in Spanish | MEDLINE | ID: mdl-38046233

ABSTRACT

Constrictive pericarditis is a rare cause of ascites and cardiac cirrhosis. We present the case of a 36-year-old male patient with a history of cirrhosis of unknown etiology, who consulted for refractory ascites, dyspnea, and lower limb swelling. Echocardiography determined constrictive pericarditis, which was corroborated by the findings of computed tomography. The clinical and hemodynamic worsening of the patient led to an emergency pericardiectomy with satisfactory recovery. This report shows a severe clinical consequence of constrictive pericarditis, cardiac cirrhosis, which was reversible with pericardial extirpation. Multimodal imaging was essential in the diagnosis of constrictive pericarditis.

6.
Arch Peru Cardiol Cir Cardiovasc ; 1(3): 139-144, 2023.
Article in Spanish | MEDLINE | ID: mdl-38090209

ABSTRACT

Background: Patients with systemic lupus erythematosus (SLE) are at high risk of cardiac compromise with high mortality. The subclinical diagnosis may improve their survival. Longitudinal myocardial deformation (strain) has been found to be useful in evaluating cardiac function in these patients. Objectives: Our aims were to evaluate myocardial function by analyzing the two-dimensional (2D) global longitudinal strain, to compare the longitudinal strain in SLE patients with controls, and to determine the correlation with SLE activity index. Material and Methods: 44 patients with SLE (50.0 ± 13 years) and 50 controls (49 ± 12 years) matched by age and sex, underwent transthoracic echocardiogram. Longitudinal strain was assessed using the speckle tracking method and SLE activity was estimated using the Systemic Lupus Erythematous Disease Activity Index (SLEDAI). A score of 4 or more, was defined as active SLE. Results: 2D global longitudinal strain was lower in patients with SLE than controls (- 17.3% ± 1.9% vs. -20%, ± 1.9% p = 0.00). The left ventricular ejection fraction (LVEF) had no specific differences in both groups in 2D (p = 0.650) or three-dimensional (3D) (p = 0.718). In lupus patients, SLEDAI ranged from 0 to 10, and 63.8% were inactive. Negative correlations were found between the SLEDAI score and 2D LVEF (Pearson's r = -0.372, p = 0.017); no correlations were found between the SLEDAI score and the 2D global longitudinal strain (Spearman's rho = - 0.091 p = 0.582). Conclusions: 2D global longitudinal strain was found to be decreased in the SLE group. This technique might can be a useful tool to assess cardiac function in these patiens.

7.
Echocardiography ; 40(12): 1310-1324, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37922234

ABSTRACT

Ventricular septal rupture (VSR) is a rare and devastating complication of acute myocardial infarction. Early detection, assessment of the hemodynamic impact, and illustration of the pathophysiological context are crucial functions of echocardiography in decision-making for intensive management and reparative intervention. To evaluate this entity, echocardiography exhibits two strengths: its bedside nature and its multiple modalities. This document reviews the comprehensive use of echocardiography in the study of post-infarction VSR.


Subject(s)
Myocardial Infarction , Ventricular Septal Rupture , Humans , Ventricular Septal Rupture/etiology , Ventricular Septal Rupture/complications , Risk Factors , Myocardial Infarction/complications , Myocardial Infarction/diagnostic imaging , Echocardiography
8.
Echocardiography ; 39(11): 1450-1454, 2022 11.
Article in English | MEDLINE | ID: mdl-36266746

ABSTRACT

We present the case of a 53-year-old patient with a giant floating thrombus in the aortic arch associated with proximal stenosis of the left subclavian artery diagnosed by multimodal imaging. Left carotid-subclavian shunt and thoracic endovascular aortic repair (TEVAR) were successful. Transesophageal echocardiography (TEE) played a substantial role in the safety and efficacy of the endovascular procedure and should be considered as an additional guide to fluoroscopy for this type of procedure.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Thrombosis , Humans , Middle Aged , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Echocardiography, Transesophageal , Stents , Thrombosis/diagnostic imaging , Thrombosis/surgery , Treatment Outcome , Blood Vessel Prosthesis , Retrospective Studies
9.
Glob Heart ; 17(1): 49, 2022.
Article in English | MEDLINE | ID: mdl-36051327

ABSTRACT

Objectives: Describe the use and findings of cardiopulmonary imaging-chest X-ray (cX-ray), echocardiography (cEcho), chest CT (cCT), lung ultrasound (LUS), and/or cardiac magnetic resonance imaging (cMRI)-in COVID-19 hospitalizations in Latin America (LATAM). Background: There is a lack of information on the images used and their findings during the SARS-CoV-2 pandemic in LATAM. Methods: Multicenter, prospective, observational study of COVID-19 inpatients, conducted from March to December 2020, from 12 high-complexity centers, in nine LATAM countries. Adults (>18 years) with at least one imaging modality performed, followed from admission until discharge and/or in-hospital death, were included. Results: We studied 1,435 hospitalized patients (64% males) with a median age of 58 years classified into three regions: Mexico (Mx), 262; Central America and Caribbean (CAC), 428; and South America (SAm), 745. More frequent comorbidities were overweight/obesity, hypertension, and diabetes. During hospitalization, 58% were admitted to the ICU. The in-hospital mortality was 28%, and it was highest in Mx (37%).The most frequent images performed were cCT (61%), mostly in Mx and SAm, and cX-ray (46%), significant in CAC. The cEcho was carried out in 18%, similarly among regions, and LUS was carried out in 7%, with a higher frequently in Mx. Abnormal findings on the cX-ray were peripheral or basal infiltrates, and in cCT abnormal findings were the ground glass infiltrates, more commonly in Mx. In LUS, interstitial syndrome was the most abnormal finding, predominantly in Mx and CAC.Renal failure was the most prevalent complication (20%), predominant in Mx and SAm. Heart failure developed in 13%, predominant in Mx and CAC. Lung thromboembolism was higher in Mx while myocardial infarction was in CAC.Logistic regression showed associations of abnormal imaging findings and their severity, with comorbidities, complications, and evolution. Conclusions: The use and findings of cardiopulmonary imaging in LATAM varied between regions and had a great impact on diagnosis and prognosis.


Subject(s)
COVID-19 , Adult , COVID-19/diagnostic imaging , COVID-19/epidemiology , Female , Hospital Mortality , Humans , Latin America/epidemiology , Male , Middle Aged , Prospective Studies , Registries , SARS-CoV-2 , Tomography, X-Ray Computed/methods
10.
Article in Spanish | MEDLINE | ID: mdl-37283602

ABSTRACT

Rheumatic heart disease is the leading cause of cardiovascular disease in children under 25 years of age worldwide, with the highest prevalence in low-income countries. The usual and distinctive finding of rheumatic aggression is mitral stenosis, which leads to serious cardiovascular consequences. International guidelines establish transthoracic echocardiography (TTE) as the diagnostic test for rheumatic heart disease; however, it has limitations in the measurement of planimetry and those inherent to Doppler. Transesophageal 3D echocardiography (TTE-3D) is a new modality that shows realistic images of the mitral valve and has the added value of accurately locating the plane of maximum stenosis and better determining commissural involvement.

13.
Arch Peru Cardiol Cir Cardiovasc ; 2(4): 227-232, 2021.
Article in Spanish | MEDLINE | ID: mdl-37727669

ABSTRACT

Objectives: During acute infection by the SARS-CoV-2 virus, myocardial involvement has been demonstrated; it is unknown if cardiovascular sequelae in patients recovered from this infection and if these are associated with global morbidity and mortality. The objective of this study was to compare myocardial deformation in patients recovered from mild SARS-CoV-2 virus infection with healthy controls. Materials and methods: This was a cross-sectional observational study that included 33 subjects recovered from mild SARS-CoV-2 infection, who were diagnosed in the previous three to six months, and 31 healthy volunteers, both groups free of cardiovascular risk factors. The study of myocardial deformation was performed using echocardiography with the speckle tracking modality. Clinical and anthropometric variables were compared. Results: The 2D global longitudinal strain of the left ventricle was lower in the subjects recovered from mild SARS-CoV-2 infection than the controls (-20.2% ± 2.6 v -21.6% ± 2.4; p: 0.036). Both groups presented differences in the three ventricular levels, significant at the apical level (-21.2 ± 4.0 vs -23.4% ± 4.2; p: 0.044). The effect by levels shows an inverse Takotsubo pattern. The left ventricular ejection fraction was preserved in both groups (p: 0.153). Conclusions: Left ventricular myocardial deformation is affected in subjects recovered from mild SARS-CoV-2 infection, while the ejection fraction was found in normal ranges. Our study shows a potential role of global longitudinal strain in the detection of subclinical myocardial alterations in patients who had SARS-CoV-2.

SELECTION OF CITATIONS
SEARCH DETAIL