Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Mater Today Bio ; 26: 101072, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38757057

ABSTRACT

Osteoarthritis (OA) is a highly disabling pathology, characterized by synovial inflammation and cartilage degeneration. Orthobiologics have shown promising results in OA treatment thanks to their ability to influence articular cells and modulate the inflammatory OA environment. Considering their complex mechanism of action, the development of reliable and relevant joint models appears as crucial to select the best orthobiologics for each patient. The aim of this study was to establish a microfluidic OA model to test therapies in a personalized human setting. The joint-on-a-chip model included cartilage and synovial compartments, containing hydrogel-embedded chondrocytes and synovial fibroblasts, separated by a channel for synovial fluid. For the cartilage compartment, a Hyaluronic Acid-based matrix was selected to preserve chondrocyte phenotype. Adding OA synovial fluid induced the production of inflammatory cytokines and degradative enzymes, generating an OA microenvironment. Personalized models were generated using patient-matched cells and synovial fluid to test the efficacy of mesenchymal stem cells on OA signatures. The patient-specific models allowed monitoring changes induced by cell injection, highlighting different individual responses to the treatment. Altogether, these results support the use of this joint-on-a-chip model as a prognostic tool to screen the patient-specific efficacy of orthobiologics.

2.
J Extracell Vesicles ; 13(1): e12408, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38263378

ABSTRACT

The release of extracellular vesicles (EVs) in cell cultures as well as their molecular cargo can be influenced by cell culture conditions such as the presence of foetal bovine serum (FBS). Although several studies have evaluated the effect of removing FBS-derived EVs by ultracentrifugation (UC), less is known about the influence of FBS heat inactivation (HI) on the cell-derived EVs. To assess this, three protocols based on different combinations of EV depletion by UC and HI were evaluated, including FBS ultracentrifuged but not heat inactivated (no-HI FBS), FBS heat inactivated before EV depletion (HI-before EV-depl FBS), and FBS heat inactivated after EV depletion (HI-after EV-depl FBS). We isolated large (L-EVs) and small EVs (S-EVs) from FBS treated in the three different ways, and we found that the S-EV pellet from HI-after EV-depl FBS was larger than the S-EV pellet from no-HI FBS and HI-before EV-depl FBS. Transmission electron microscopy, protein quantification, and particle number evaluation showed that HI-after EV-depl significantly increased the protein amount of S-EVs but had no significant effect on L-EVs. Consequently, the protein quantity of S-EVs isolated from three cell lines cultured in media supplemented with HI-after EV-depl FBS was significantly increased. Quantitative mass spectrometry analysis of FBS-derived S-EVs showed that the EV protein content was different when FBS was HI after EV depletion compared to EVs isolated from no-HI FBS and HI-before EV-depl FBS. Moreover, we show that several quantified proteins could be ascribed to human origin, thus demonstrating that FBS bovine proteins can mistakenly be attributed to human cell-derived EVs. We conclude that HI of FBS performed after EV depletion results in changes in the proteome, with molecules that co-isolate with EVs and can contaminate EVs when used in subsequent cell cultures. Our recommendation is, therefore, to always perform HI of FBS prior to EV depletion.


Subject(s)
Extracellular Vesicles , Proteome , Humans , Serum Albumin, Bovine , Hot Temperature , Cell Culture Techniques
3.
Bone Joint Res ; 9(9): 613-622, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33072305

ABSTRACT

AIMS: In the context of tendon degenerative disorders, the need for innovative conservative treatments that can improve the intrinsic healing potential of tendon tissue is progressively increasing. In this study, the role of pulsed electromagnetic fields (PEMFs) in improving the tendon healing process was evaluated in a rat model of collagenase-induced Achilles tendinopathy. METHODS: A total of 68 Sprague Dawley rats received a single injection of type I collagenase in Achilles tendons to induce the tendinopathy and then were daily exposed to PEMFs (1.5 mT and 75 Hz) for up to 14 days - starting 1, 7, or 15 days after the injection - to identify the best treatment option with respect to the phase of the disease. Then, 7 and 14 days of PEMF exposure were compared to identify the most effective protocol. RESULTS: The daily exposure to PEMFs generally provided an improvement in the fibre organization, a decrease in cell density, vascularity, and fat deposition, and a restoration of the physiological cell morphology compared to untreated tendons. These improvements were more evident when the tendons were exposed to PEMFs during the mid-acute phase of the pathology (7 days after induction) rather than during the early (1 day after induction) or the late acute phase (15 days after induction). Moreover, the exposure to PEMFs for 14 days during the mid-acute phase was more effective than for 7 days. CONCLUSION: PEMFs exerted a positive role in the tendon healing process, thus representing a promising conservative treatment for tendinopathy, although further investigations regarding the clinical evaluation are needed.Cite this article: Bone Joint Res 2020;9(9):613-622.

4.
Cells ; 9(6)2020 05 28.
Article in English | MEDLINE | ID: mdl-32481562

ABSTRACT

The prevalence of arthritic diseases is increasing in developed countries, but effective treatments are currently lacking. The injection of mesenchymal stem cells (MSCs) represents a promising approach to counteract the degenerative and inflammatory environment characterizing those pathologies, such as osteoarthritis (OA). However, the majority of clinical approaches based on MSCs are used within an autologous paradigm, with important limitations. For this reason, allogeneic MSCs isolated from cord blood (cbMSCs) and Wharton's jelly (wjMSCs) gained increasing interest, demonstrating promising results in this field. Moreover, recent evidences shows that MSCs beneficial effects can be related to their secretome rather than to the presence of cells themselves. Among the trophic factors secreted by MSCs, extracellular vesicles (EVs) are emerging as a promising candidate for the treatment of arthritic joints. In the present review, the application of umbilical cord MSCs and their secretome as innovative therapeutic approaches in the treatment of arthritic joints will be examined. With the prospective of routine clinical applications, umbilical cord MSCs and EVs will be discussed also within an industrial and regulatory perspective.


Subject(s)
Biomedical Research , Drug Industry , Mesenchymal Stem Cells/cytology , Proteome/metabolism , Umbilical Cord/cytology , Animals , Arthritis/therapy , Humans
5.
Ann Biomed Eng ; 48(3): 1112-1126, 2020 Mar.
Article in English | MEDLINE | ID: mdl-30963381

ABSTRACT

Tissue-engineered decellularized matrices can progress clinical replacement of full-thickness ruptures or tendon defects. This study develops and validates a custom-made automated bioreactor, called oscillating stretch-perfusion bioreactor (OSPB), consisting of multiple, independent culture chambers able to combine a bidirectional perfusion with a programmable, uniaxial strain to functionalize cell-seeded decellularized tendons. Decellularized tendon matrices were seeded on their surfaces and within the tendon fibers with mesenchymal stem cells. Then, they were subjected to a bidirectional perfusion and programmed stretching cycles of 15-30-60 min on-off two times per day for 7 days of culture. In vitro analyses showed viable cells, homogenously distributed on the surface of the constructs. More importantly, cell-seeded decellularized tendon grafts undergoing cyclic load in our bioreactor had a superior production and organization of newly formed collagen matrix compared to static cultured constructs. The coherency and local alignment of the new collagen deposition within the inner injected channels quantitatively supported histological findings. The designed OSPB could be considered a unique, cost-effective system able to involve multiple independently controlled chambers in terms of biological and mechanical protocols. This system allows parallel processing of several customized tendon constructs to be used as grafts to enhance the surgical repair of large tendon defects.


Subject(s)
Bioreactors , Mesenchymal Stem Cells , Tendons , Tissue Engineering/methods , Animals , Cell Survival , Cells, Cultured , Rabbits , Tendons/ultrastructure
6.
J Clin Med ; 8(11)2019 Nov 04.
Article in English | MEDLINE | ID: mdl-31689923

ABSTRACT

Secretome and extracellular vesicles (EVs) are considered a promising option to exploit mesenchymal stem cells' (MSCs) properties to address knee osteoarthritis (OA). The aim of this systematic review was to analyze both the in vitro and in vivo literature, in order to understand the potential of secretome and EVs as a minimally invasive injective biological approach. A systematic review of the literature was performed on PubMed, Embase, and Web of Science databases up to 31 August 2019. Twenty studies were analyzed; nine in vitro, nine in vitro and in vivo, and two in vivo. The analysis showed an increasing interest in this emerging field, with overall positive findings. Promising in vitro results were documented in terms of enhanced cell proliferation, reduction of inflammation, and down-regulation of catabolic pathways while promoting anabolic processes. The positive in vitro findings were confirmed in vivo, with studies showing positive effects on cartilage, subchondral bone, and synovial tissues in both OA and osteochondral models. However, several aspects remain to be clarified, such as the different effects induced by EVs and secretome, which is the most suitable cell source and production protocol, and the identification of patients who may benefit more from this new biological approach for knee OA treatment.

7.
Stem Cells Int ; 2019: 5267479, 2019.
Article in English | MEDLINE | ID: mdl-31558905

ABSTRACT

Tendon tissue ruptures often require the replacement of damaged tissues. The use of auto- or allografts is notoriously limited due to the scarce supply and the high risks of immune adverse reactions. To overcome these limitations, tissue engineering (TE) has been considered a promising approach. Among several biomaterials, decellularized xenografts are available in large quantity and could represent a possible solution for tendon reconstruction. The present study is aimed at evaluating TE xenografts in Achilles tendon defects. Specifically, the ability to enhance the biomechanical functionality, while improving the graft interaction with the host, was tested. The combination of decellularized equine-derived tendon xenografts with or without the matrix repopulation with autologous bone marrow mesenchymal stem cells (BMSCs) under stretch-perfusion dynamic conditions might improve the side-to-side tendon reconstruction. Thirty-six New Zealand rabbits were used to create 2 cm long segmental defects of the Achilles tendon. Then, animals were implanted with autograft (AG) as the gold standard control, decellularized graft (DG), or in vitro tissue-engineered graft (TEG) and evaluated postoperatively at 12 weeks. After sacrifice, histological, immunohistochemical, biochemical, and biomechanical analyses were performed along with the matrix metalloproteinases. The results demonstrated the beneficial role of undifferentiated BMSCs loaded within decellularized xenografts undergoing a stretch-perfusion culture as an immunomodulatory weapon reducing the inflammatory process. Interestingly, AG and TEG groups exhibited similar results, behaved similarly, and showed a significant superior tissue healing compared to DG in terms of newly formed collagen fibres and biomechanical parameters. Whereas, DG demonstrated a massive inflammatory and giant cell response associated with graft destruction and necrosis, absence of type I and III collagen, and a higher amount of proteoglycans and MMP-2, thus unfavourably affecting the biomechanical response. In conclusion, this in vivo study suggests a potential use of the proposed tissue-engineered constructs for tendon reconstruction.

8.
Front Cell Neurosci ; 12: 427, 2018.
Article in English | MEDLINE | ID: mdl-30510503

ABSTRACT

Peripheral nerve regeneration after severe traumatic nerve injury is a relevant clinical problem. Several different strategies have been investigated to solve the problem of bridging the nerve gap. Among these, the use of decellularized nerve grafts has been proposed as an alternative to auto/isografts, which represent the current gold standard in the treatment of severe nerve injury. This study reports the results of a systematic review of the literature published between January 2007 and October 2017. The aim was to quantitatively analyze the effectiveness of decellularized nerve grafts in rat experimental models. The review included 33 studies in which eight different decellularization protocols were described. The decellularized nerve grafts were reported to be immunologically safe and able to support both functional and morphological regeneration after nerve injury. Chemical protocols were found to be superior to physical protocols. However, further research is needed to optimize preparation protocols, including recellularization, improve their effectiveness, and substitute the current gold standard, especially in the repair of long nerve defects.

SELECTION OF CITATIONS
SEARCH DETAIL
...