Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 71
Filter
1.
Sci Rep ; 14(1): 14169, 2024 06 19.
Article in English | MEDLINE | ID: mdl-38898066

ABSTRACT

According to the literature, seizure prediction models should be developed following a patient-specific approach. However, seizures are usually very rare events, meaning the number of events that may be used to optimise seizure prediction approaches is limited. To overcome such constraint, we analysed the possibility of using data from patients from an external database to improve patient-specific seizure prediction models. We present seizure prediction models trained using a transfer learning procedure. We trained a deep convolutional autoencoder using electroencephalogram data from 41 patients collected from the EPILEPSIAE database. Then, a bidirectional long short-term memory and a classifier layers were added on the top of the encoder part and were optimised for 24 patients from the Universitätsklinikum Freiburg individually. The encoder was used as a feature extraction module. Therefore, its weights were not changed during the patient-specific training. Experimental results showed that seizure prediction models optimised using pretrained weights present about four times fewer false alarms while maintaining the same ability to predict seizures and achieved more 13% validated patients. Therefore, results evidenced that the optimisation using transfer learning was more stable and faster, saving computational resources. In summary, adopting transfer learning for seizure prediction models represents a significant advancement. It addresses the data limitation seen in the seizure prediction field and offers more efficient and stable training, conserving computational resources. Additionally, despite the compact size, transfer learning allows to easily share data knowledge due to fewer ethical restrictions and lower storage requirements. The convolutional autoencoder developed in this study will be shared with the scientific community, promoting further research.


Subject(s)
Electroencephalography , Seizures , Humans , Seizures/diagnosis , Seizures/physiopathology , Electroencephalography/methods , Databases, Factual , Machine Learning , Female , Male , Neural Networks, Computer , Adult
2.
Physiol Meas ; 45(6)2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38772401

ABSTRACT

Objective. This paper aims to investigate the possibility of detecting tonic-clonic seizures (TCSs) with behind-the-ear, two-channel wearable electroencephalography (EEG), and to evaluate its added value to non-EEG modalities in TCS detection.Methods. We included 27 participants with a total of 44 TCSs from the European multicenter study SeizeIT2. The wearable Sensor Dot (Byteflies) was used to measure behind-the-ear EEG, electromyography (EMG), electrocardiography, accelerometry (ACC) and gyroscope. We evaluated automatic unimodal detection of TCSs, using sensitivity, precision, false positive rate (FPR) and F1-score. Subsequently, we fused the different modalities and again assessed performance. Algorithm-labeled segments were then provided to two experts, who annotated true positive TCSs, and discarded false positives.Results. Wearable EEG outperformed the other single modalities with a sensitivity of 100% and a FPR of 10.3/24 h. The combination of wearable EEG and EMG proved most clinically useful, delivering a sensitivity of 97.7%, an FPR of 0.4/24 h, a precision of 43%, and an F1-score of 59.7%. The highest overall performance was achieved through the fusion of wearable EEG, EMG, and ACC, yielding a sensitivity of 90.9%, an FPR of 0.1/24 h, a precision of 75.5%, and an F1-score of 82.5%.Conclusions. In TCS detection with a wearable device, combining EEG with EMG, ACC or both resulted in a remarkable reduction of FPR, while retaining a high sensitivity.Significance. Adding wearable EEG could further improve TCS detection, relative to extracerebral-based systems.


Subject(s)
Accelerometry , Electroencephalography , Electromyography , Seizures , Signal Processing, Computer-Assisted , Wearable Electronic Devices , Humans , Electroencephalography/instrumentation , Electroencephalography/methods , Electromyography/instrumentation , Accelerometry/instrumentation , Seizures/diagnosis , Seizures/physiopathology , Male , Female , Adult , Middle Aged , Young Adult
3.
Epilepsia ; 65(3): 651-663, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38258618

ABSTRACT

OBJECTIVE: We aimed to assess the ability of semiautomated electric source imaging (ESI) from long-term video-electroencephalographic (EEG) monitoring (LTM) to determine the epileptogenicity of temporopolar encephaloceles (TEs) in patients with temporal lobe epilepsy. METHODS: We conducted a retrospective study involving 32 temporal lobe epilepsy patients with TEs as potentially epileptogenic lesions in structural magnetic resonance imaging scans. Findings were validated through invasive intracerebral stereo-EEG in six of 32 patients and postsurgical outcome after tailored resection of the TE in 17 of 32 patients. LTM (mean duration = 6 days) was performed using the 10/20 system with additional T1/T2 for all patients and sphenoidal electrodes in 23 of 32 patients. Semiautomated detection and clustering of interictal epileptiform discharges (IEDs) were carried out to create IED types. ESI was performed on the averages of the two most frequent IED types per patient, utilizing individual head models, and two independent inverse methods (sLORETA [standardized low-resolution brain electromagnetic tomography], MUSIC [multiple signal classification]). ESI maxima concordance and propagation in spatial relation to TEs were quantified for sources with good signal quality (signal-to-noise ratio > 2, explained signal > 60%). RESULTS: ESI maxima correctly colocalized with a TE in 20 of 32 patients (62.5%) either at the onset or half-rising flank of at least one IED type per patient. ESI maxima showed propagation from the temporal pole to other temporal or extratemporal regions in 14 of 32 patients (44%), confirming propagation originating in the area of the TE. The findings from both inverse methods validated each other in 14 of 20 patients (70%), and sphenoidal electrodes exhibited the highest signal amplitudes in 17 of 23 patients (74%). The concordance of ESI with the TE predicted a seizure-free postsurgical outcome (Engel I vs. >I) with a diagnostic odds ratio of 2.1. SIGNIFICANCE: Semiautomated ESI from LTM often successfully identifies the epileptogenicity of TEs and the IED onset zone within the area of the TEs. Additionally, it shows potential predictive power for postsurgical outcomes in these patients.


Subject(s)
Epilepsy, Temporal Lobe , Humans , Epilepsy, Temporal Lobe/complications , Epilepsy, Temporal Lobe/diagnostic imaging , Epilepsy, Temporal Lobe/surgery , Electroencephalography/methods , Encephalocele/complications , Encephalocele/diagnostic imaging , Retrospective Studies , Temporal Lobe/diagnostic imaging , Temporal Lobe/surgery , Magnetic Resonance Imaging
4.
Epilepsia ; 65(2): 378-388, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38036450

ABSTRACT

OBJECTIVE: Home monitoring of 3-Hz spike-wave discharges (SWDs) in patients with refractory absence epilepsy could improve clinical care by replacing the inaccurate seizure diary with objective counts. We investigated the use and performance of the Sensor Dot (Byteflies) wearable in persons with absence epilepsy in their home environment. METHODS: Thirteen participants (median age = 22 years, 11 female) were enrolled at the university hospitals of Leuven and Freiburg. At home, participants had to attach the Sensor Dot and behind-the-ear electrodes to record two-channel electroencephalogram (EEG), accelerometry, and gyroscope data. Ground truth annotations were created during a visual review of the full Sensor Dot recording. Generalized SWDs were annotated if they were 3 Hz and at least 3 s on EEG. Potential 3-Hz SWDs were flagged by an automated seizure detection algorithm, (1) using only EEG and (2) with an additional postprocessing step using accelerometer and gyroscope to discard motion artifacts. Afterward, two readers (W.V.P. and L.S.) reviewed algorithm-labeled segments and annotated true positive detections. Sensitivity, precision, and F1 score were calculated. Patients had to keep a seizure diary and complete questionnaires about their experiences. RESULTS: Total recording time was 394 h 42 min. Overall, 234 SWDs were captured in 11 of 13 participants. Review of the unimodal algorithm-labeled recordings resulted in a mean sensitivity of .84, precision of .93, and F1 score of .89. Visual review of the multimodal algorithm-labeled segments resulted in a similar F1 score and shorter review time due to fewer false positive labels. Participants reported that the device was comfortable and that they would be willing to wear it on demand of their neurologist, for a maximum of 1 week or with intermediate breaks. SIGNIFICANCE: The Sensor Dot improved seizure documentation at home, relative to patient self-reporting. Additional benefits were the short review time and the patients' device acceptance due to user-friendliness and comfortability.


Subject(s)
Drug Resistant Epilepsy , Epilepsy, Absence , Wearable Electronic Devices , Adult , Female , Humans , Young Adult , Electrodes , Electroencephalography/methods , Seizures/diagnosis , Male
5.
Front Netw Physiol ; 3: 1297345, 2023.
Article in English | MEDLINE | ID: mdl-38107334

ABSTRACT

Over the past decades, studies of human brain networks have received growing attention as the assessment and modelling of connectivity in the brain is a topic of high impact with potential application in the understanding of human brain organization under both physiological as well as various pathological conditions. Under specific diagnostic settings, human neuronal signal can be obtained from intracranial EEG (iEEG) recording in epilepsy patients that allows gaining insight into the functional organisation of living human brain. There are two approaches to assess brain connectivity in the iEEG-based signal: evaluation of spontaneous neuronal oscillations during ongoing physiological and pathological brain activity, and analysis of the electrophysiological cortico-cortical neuronal responses, evoked by single pulse electrical stimulation (SPES). Both methods have their own advantages and limitations. The paper outlines available methodological approaches and provides an overview of current findings in studies of physiological and pathological human brain networks, based on intracranial EEG recordings.

6.
Ann Clin Transl Neurol ; 10(10): 1863-1872, 2023 10.
Article in English | MEDLINE | ID: mdl-37608738

ABSTRACT

OBJECTIVE: Circadian and multidien cycles of seizure occurrence are increasingly discussed as to their biological underpinnings and in the context of seizure forecasting. This study analyzes if patient reported seizures provide valid data on such cyclical occurrence. METHODS: We retrospectively studied if circadian cycles derived from patient-based reporting reflect the objective seizure documentation in 2003 patients undergoing in-patient video-EEG monitoring. RESULTS: Only 24.1% of more than 29000 seizures documented were accompanied by patient notifications. There was cyclical underreporting of seizures with a maximum during nighttime, leading to significant deviations in the circadian distribution of seizures. Significant cyclical deviations were found for focal epilepsies originating from both, frontal and temporal lobes, and for different seizure types (in particular, focal unaware and focal to bilateral tonic-clonic seizures). INTERPRETATION: Patient seizure diaries may reflect a cyclical reporting bias rather than the true circadian seizure distributions. Cyclical underreporting of seizures derived from patient-based reports alone may lead to suboptimal treatment schemes, to an underestimation of seizure-associated risks, and may pose problems for valid seizure forecasting. This finding strongly supports the use of objective measures to monitor cyclical distributions of seizures and for studies and treatment decisions based thereon.


Subject(s)
Epilepsies, Partial , Seizures , Humans , Retrospective Studies , Seizures/diagnosis , Epilepsies, Partial/diagnosis , Electroencephalography , Documentation
7.
Sci Rep ; 13(1): 5918, 2023 04 11.
Article in English | MEDLINE | ID: mdl-37041158

ABSTRACT

The development of seizure prediction models is often based on long-term scalp electroencephalograms (EEGs) since they capture brain electrical activity, are non-invasive, and come at a relatively low-cost. However, they suffer from major shortcomings. First, long-term EEG is usually highly contaminated with artefacts. Second, changes in the EEG signal over long intervals, known as concept drift, are often neglected. We evaluate the influence of these problems on deep neural networks using EEG time series and on shallow neural networks using widely-used EEG features. Our patient-specific prediction models were tested in 1577 hours of continuous EEG, containing 91 seizures from 41 patients with temporal lobe epilepsy who were undergoing pre-surgical monitoring. Our results showed that cleaning EEG data, using a previously developed artefact removal method based on deep convolutional neural networks, improved prediction performance. We also found that retraining the models over time reduced false predictions. Furthermore, the results show that although deep neural networks processing EEG time series are less susceptible to false alarms, they may need more data to surpass feature-based methods. These findings highlight the importance of robust data denoising and periodic adaptation of seizure prediction models.


Subject(s)
Artifacts , Epilepsy, Temporal Lobe , Humans , Seizures , Neural Networks, Computer , Electroencephalography/methods
8.
Sci Rep ; 12(1): 21412, 2022 Dec 10.
Article in English | MEDLINE | ID: mdl-36496546

ABSTRACT

Wearable recordings of neurophysiological signals captured from the wrist offer enormous potential for seizure monitoring. Yet, data quality remains one of the most challenging factors that impact data reliability. We suggest a combined data quality assessment tool for the evaluation of multimodal wearable data. We analyzed data from patients with epilepsy from four epilepsy centers. Patients wore wristbands recording accelerometry, electrodermal activity, blood volume pulse, and skin temperature. We calculated data completeness and assessed the time the device was worn (on-body), and modality-specific signal quality scores. We included 37,166 h from 632 patients in the inpatient and 90,776 h from 39 patients in the outpatient setting. All modalities were affected by artifacts. Data loss was higher when using data streaming (up to 49% among inpatient cohorts, averaged across respective recordings) as compared to onboard device recording and storage (up to 9%). On-body scores, estimating the percentage of time a device was worn on the body, were consistently high across cohorts (more than 80%). Signal quality of some modalities, based on established indices, was higher at night than during the day. A uniformly reported data quality and multimodal signal quality index is feasible, makes study results more comparable, and contributes to the development of devices and evaluation routines necessary for seizure monitoring.


Subject(s)
Epilepsy , Wearable Electronic Devices , Humans , Data Accuracy , Reproducibility of Results , Seizures , Epilepsy/diagnosis
9.
Biomedicines ; 10(10)2022 Oct 21.
Article in English | MEDLINE | ID: mdl-36289925

ABSTRACT

Epilepsy is one of the most common neurological disorders, characterized by the occurrence of repeated seizures. Given that epilepsy is considered a network disorder, tools derived from network neuroscience may confer the valuable ability to quantify the properties of epileptic brain networks. In this study, we use well-established brain network metrics (i.e., mean strength, variance of strength, eigenvector centrality, betweenness centrality) to characterize the temporal evolution of epileptic functional networks over several days prior to seizure occurrence. We infer the networks using long-term electroencephalographic recordings from 12 people with epilepsy. We found that brain network metrics are variable across days and show a circadian periodicity. In addition, we found that in 9 out of 12 patients the distribution of the variance of strength in the day (or even two last days) prior to seizure occurrence is significantly different compared to the corresponding distributions on all previous days. Our results suggest that brain network metrics computed fromelectroencephalographic recordings could potentially be used to characterize brain network changes that occur prior to seizures, and ultimately contribute to seizure warning systems.

10.
Sci Data ; 9(1): 512, 2022 08 20.
Article in English | MEDLINE | ID: mdl-35987693

ABSTRACT

Scalp electroencephalogram is a non-invasive multi-channel biosignal that records the brain's electrical activity. It is highly susceptible to noise that might overshadow important data. Independent component analysis is one of the most used artifact removal methods. Independent component analysis separates data into different components, although it can not automatically reject the noisy ones. Therefore, experts are needed to decide which components must be removed before reconstructing the data. To automate this method, researchers have developed classifiers to identify noisy components. However, to build these classifiers, they need annotated data. Manually classifying independent components is a time-consuming task. Furthermore, few labelled data are publicly available. This paper presents a source of annotated electroencephalogram independent components acquired from patients with epilepsy (EPIC Dataset). This dataset contains 77,426 independent components obtained from approximately 613 hours of electroencephalogram, visually inspected by two experts, which was already successfully utilised to develop independent component classifiers.


Subject(s)
Artifacts , Epilepsy , Algorithms , Electroencephalography/methods , Epilepsy/diagnosis , Humans , Signal Processing, Computer-Assisted
11.
Sensors (Basel) ; 22(9)2022 Apr 26.
Article in English | MEDLINE | ID: mdl-35591007

ABSTRACT

Focal onset epileptic seizures are highly heterogeneous in their clinical manifestations, and a robust seizure detection across patient cohorts has to date not been achieved. Here, we assess and discuss the potential of supervised machine learning models for the detection of focal onset motor seizures by means of a wrist-worn wearable device, both in a personalized context as well as across patients. Wearable data were recorded in-hospital from patients with epilepsy at two epilepsy centers. Accelerometry, electrodermal activity, and blood volume pulse data were processed and features for each of the biosignal modalities were calculated. Following a leave-one-out approach, a gradient tree boosting machine learning model was optimized and tested in an intra-subject and inter-subject evaluation. In total, 20 seizures from 9 patients were included and we report sensitivities of 67% to 100% and false alarm rates of down to 0.85 per 24 h in the individualized assessment. Conversely, for an inter-subject seizure detection methodology tested on an out-of-sample data set, an optimized model could only achieve a sensitivity of 75% at a false alarm rate of 13.4 per 24 h. We demonstrate that robustly detecting focal onset motor seizures with tonic or clonic movements from wearable data may be possible for individuals, depending on specific seizure manifestations.


Subject(s)
Epilepsies, Partial , Epilepsy , Wearable Electronic Devices , Accelerometry , Electroencephalography/methods , Epilepsy/diagnosis , Humans , Seizures/diagnosis
12.
Epilepsia ; 2022 Apr 20.
Article in English | MEDLINE | ID: mdl-35441703

ABSTRACT

This study describes a generalized cross-patient seizure-forecasting approach using recurrent neural networks with ultra-long-term subcutaneous EEG (sqEEG) recordings. Data from six patients diagnosed with refractory epilepsy and monitored with an sqEEG device were used to develop a generalized algorithm for seizure forecasting using long short-term memory (LSTM) deep-learning classifiers. Electrographic seizures were identified by a board-certified epileptologist. One-minute data segments were labeled as preictal or interictal based on their relationship to confirmed seizures. Data were separated into training and testing data sets, and to compensate for the unbalanced data ratio in training, noise-added copies of preictal data segments were generated to expand the training data set. The mean and standard deviation (SD) of the training data were used to normalize all data, preserving the pseudo-prospective nature of the analysis. Different architecture classifiers were trained and tested using a leave-one-patient-out cross-validation method, and the area under the receiver-operating characteristic (ROC) curve (AUC) was used to evaluate the performance classifiers. The importance of each input signal was evaluated using a leave-one-signal-out method with repeated training and testing for each classifier. Cross-patient classifiers achieved performance significantly better than chance in four of the six patients and an overall mean AUC of 0.602 ± 0.126 (mean ± SD). A time in warning of 37.386% ± 5.006% (mean ± std) and sensitivity of 0.691 ± 0.068 (mean ± std) were observed for patients with better than chance results. Analysis of input channels showed a significant contribution (p < .05) by the Fourier transform of signals channels to overall classifier performance. The relative contribution of input signals varied among patients and architectures, suggesting that the inclusion of all signals contributes to robustness in a cross-patient classifier. These early results show that it is possible to forecast seizures training with data from different patients using two-channel ultra-long-term sqEEG.

13.
Epilepsia ; 2022 Apr 08.
Article in English | MEDLINE | ID: mdl-35395101

ABSTRACT

OBJECTIVE: One of the most disabling aspects of living with chronic epilepsy is the unpredictability of seizures. Cumulative research in the past decades has advanced our understanding of the dynamics of seizure risk. Technological advances have recently made it possible to record pertinent biological signals, including electroencephalogram (EEG), continuously. We aimed to assess whether patient-specific seizure forecasting is possible using remote, minimally invasive ultra-long-term subcutaneous EEG. METHODS: We analyzed a two-center cohort of ultra-long-term subcutaneous EEG recordings, including six patients with drug-resistant focal epilepsy monitored for 46-230 days with median 18 h/day of recorded data, totaling >11 000 h of EEG. Total electrographic seizures identified by visual review ranged from 12 to 36 per patient. Three candidate subject-specific long short-term memory network deep learning classifiers were trained offline and pseudoprospectively on preictal (1 h before) and interictal (>1 day from seizures) EEG segments. Performance was assessed relative to a random predictor. Periodicity of the final forecasts was also investigated with autocorrelation. RESULTS: Depending on each architecture, significant forecasting performance was achieved in three to five of six patients, with overall mean area under the receiver operating characteristic curve of .65-.74. Significant forecasts showed sensitivity ranging from 64% to 80% and time in warning from 10.9% to 44.4%. Overall, the output of the forecasts closely followed patient-specific circadian patterns of seizure occurrence. SIGNIFICANCE: This study demonstrates proof-of-principle for the possibility of subject-specific seizure forecasting using a minimally invasive subcutaneous EEG device capable of ultra-long-term at-home recordings. These results are encouraging for the development of a prospective seizure forecasting trial with minimally invasive EEG.

14.
Epilepsia ; 63(7): 1619-1629, 2022 07.
Article in English | MEDLINE | ID: mdl-35357698

ABSTRACT

OBJECTIVES: High counts of averaged interictal epileptiform discharges (IEDs) are key components of accurate interictal electric source imaging (ESI) in patients with focal epilepsy. Automated detections may be time-efficient, but they need to identify the correct IED types. Thus we compared semiautomated and automated detection of IED types in long-term video-EEG (electroencephalography) monitoring (LTM) using an extended scalp EEG array and short-term high-density EEG (hdEEG) with visual detection of IED types and the seizure-onset zone (SOZ). METHODS: We prospectively recruited consecutive patients from four epilepsy centers who underwent both LTM with 40-electrode scalp EEG and short-term hdEEG with 256 electrodes. Only patients with a single circumscribed SOZ in LTM were included. In LTM and hdEEG, IED types were identified visually, semiautomatically and automatically. Concordances of semiautomated and automated detections in LTM and hdEEG, as well as visual detections in hdEEG, were compared against visually detected IED types and the SOZ in LTM. RESULTS: Fifty-two of 62 patients with LTM and hdEEG were included. The most frequent IED types per patient, detected semiautomatically and automatically in LTM and visually in hdEEG, were significantly concordant with the most frequently visually identified IED type in LTM and the SOZ. Semiautomated and automated detections of IED types in hdEEG were significantly concordant with visually identified IED types in LTM, only when IED types with more than 50 detected single IEDs were selected. The threshold of 50 detected IED in hdEEG was reached in half of the patients. For all IED types per patient, agreement between visual and semiautomated detections in LTM was high. SIGNIFICANCE: Semiautomated and automated detections of IED types in LTM show significant agreement with visually detected IED types and the SOZ. In short-term hdEEG, semiautomated detections of IED types are concordant with visually detected IED types and the SOZ in LTM if high IED counts were detected.


Subject(s)
Epilepsies, Partial , Scalp , Electroencephalography/methods , Epilepsies, Partial/diagnosis , Humans , Magnetic Resonance Imaging/methods , Prospective Studies , Seizures
15.
Article in English | MEDLINE | ID: mdl-35213313

ABSTRACT

OBJECTIVE: Independent component analysis (ICA) is commonly used to remove noisy artifacts from multi-channel scalp electroencephalogram (EEG) signals. ICA decomposes EEG into different independent components (ICs) and then, experts remove the noisy ones. This process is highly time-consuming and experts are not always available. To surpass this drawback, research is going on to develop models to automatically conduct IC classification. Current state-of-the-art models use power spectrum densities (PSDs) and topoplots to classify ICs. The performance of these methods may be limited by disregarding the IC time-series that would contribute to fully simulate the visual inspection performed by experts. METHODS: We present a novel ensemble deep neural network that combines time-series, PSDs, and topoplots to classify ICs. Moreover, we study the ability to use our model in transfer learning approaches. RESULTS: Experimental results showed that using time-series improves IC classification. Results also indicated that transfer learning obtained higher performance than simply training a new model from scratch. CONCLUSION: Researchers should develop IC classifiers using the three sources of information. Moreover, transfer learning approaches should be considered when producing new deep learning models. SIGNIFICANCE: This work improves IC classification, enhancing the automatic removal of EEG artifacts. Additionally, since labelled ICs are generally not publicly available, the possibility of using our model in transfer learning studies may motivate other researchers to develop their own classifiers.


Subject(s)
Artifacts , Signal Processing, Computer-Assisted , Algorithms , Brain , Electroencephalography/methods , Humans , Neural Networks, Computer
16.
Sci Rep ; 11(1): 21935, 2021 11 09.
Article in English | MEDLINE | ID: mdl-34754043

ABSTRACT

The ability to forecast seizures minutes to hours in advance of an event has been verified using invasive EEG devices, but has not been previously demonstrated using noninvasive wearable devices over long durations in an ambulatory setting. In this study we developed a seizure forecasting system with a long short-term memory (LSTM) recurrent neural network (RNN) algorithm, using a noninvasive wrist-worn research-grade physiological sensor device, and tested the system in patients with epilepsy in the field, with concurrent invasive EEG confirmation of seizures via an implanted recording device. The system achieved forecasting performance significantly better than a random predictor for 5 of 6 patients studied, with mean AUC-ROC of 0.80 (range 0.72-0.92). These results provide the first clear evidence that direct seizure forecasts are possible using wearable devices in the ambulatory setting for many patients with epilepsy.


Subject(s)
Deep Learning , Memory , Seizures/diagnosis , Wearable Electronic Devices , Adult , Cohort Studies , Electroencephalography , Female , Forecasting , Humans , Male , Middle Aged , Seizures/physiopathology , Wrist , Young Adult
17.
JMIR Mhealth Uhealth ; 9(11): e27674, 2021 11 19.
Article in English | MEDLINE | ID: mdl-34806993

ABSTRACT

BACKGROUND: Video electroencephalography recordings, routinely used in epilepsy monitoring units, are the gold standard for monitoring epileptic seizures. However, monitoring is also needed in the day-to-day lives of people with epilepsy, where video electroencephalography is not feasible. Wearables could fill this gap by providing patients with an accurate log of their seizures. OBJECTIVE: Although there are already systems available that provide promising results for the detection of tonic-clonic seizures (TCSs), research in this area is often limited to detection from 1 biosignal modality or only during the night when the patient is in bed. The aim of this study is to provide evidence that supervised machine learning can detect TCSs from multimodal data in a new data set during daytime and nighttime. METHODS: An extensive data set of biosignals from a multimodal watch worn by people with epilepsy was recorded during their stay in the epilepsy monitoring unit at 2 European clinical sites. From a larger data set of 243 enrolled participants, those who had data recorded during TCSs were selected, amounting to 10 participants with 21 TCSs. Accelerometry and electrodermal activity recorded by the wearable device were used for analysis, and seizure manifestation was annotated in detail by clinical experts. Ten accelerometry and 3 electrodermal activity features were calculated for sliding windows of variable size across the data. A gradient tree boosting algorithm was used for seizure detection, and the optimal parameter combination was determined in a leave-one-participant-out cross-validation on a training set of 10 seizures from 8 participants. The model was then evaluated on an out-of-sample test set of 11 seizures from the remaining 2 participants. To assess specificity, we additionally analyzed data from up to 29 participants without TCSs during the model evaluation. RESULTS: In the leave-one-participant-out cross-validation, the model optimized for sensitivity could detect all 10 seizures with a false alarm rate of 0.46 per day in 17.3 days of data. In a test set of 11 out-of-sample TCSs, amounting to 8.3 days of data, the model could detect 10 seizures and produced no false positives. Increasing the test set to include data from 28 more participants without additional TCSs resulted in a false alarm rate of 0.19 per day in 78 days of wearable data. CONCLUSIONS: We show that a gradient tree boosting machine can robustly detect TCSs from multimodal wearable data in an original data set and that even with very limited training data, supervised machine learning can achieve a high sensitivity and low false-positive rate. This methodology may offer a promising way to approach wearable-based nonconvulsive seizure detection.


Subject(s)
Seizures , Wearable Electronic Devices , Accelerometry , Algorithms , Electroencephalography , Humans , Seizures/diagnosis
18.
Sensors (Basel) ; 21(18)2021 Sep 08.
Article in English | MEDLINE | ID: mdl-34577222

ABSTRACT

Photoplethysmography (PPG) as an additional biosignal for a seizure detector has been underutilized so far, which is possibly due to its susceptibility to motion artifacts. We investigated 62 focal seizures from 28 patients with electrocardiography-based evidence of ictal tachycardia (IT). Seizures were divided into subgroups: those without epileptic movements and those with epileptic movements not affecting and affecting the extremities. PPG-based heart rate (HR) derived from a wrist-worn device was calculated for sections with high signal quality, which were identified using spectral entropy. Overall, IT based on PPG was identified in 37 of 62 (60%) seizures (9/19, 7/8, and 21/35 in the three groups, respectively) and could be found prior to the onset of epileptic movements affecting the extremities in 14/21 seizures. In 30/37 seizures, PPG-based IT was in good temporal agreement (<10 s) with ECG-based IT, with an average delay of 5.0 s relative to EEG onset. In summary, we observed that the identification of IT by means of a wearable PPG sensor is possible not only for non-motor seizures but also in motor seizures, which is due to the early manifestation of IT in a relevant subset of focal seizures. However, both spontaneous and epileptic movements can impair PPG-based seizure detection.


Subject(s)
Photoplethysmography , Wearable Electronic Devices , Electrocardiography , Electroencephalography , Heart Rate , Humans , Seizures/diagnosis , Signal Processing, Computer-Assisted , Tachycardia
19.
Brain ; 144(10): 3078-3088, 2021 11 29.
Article in English | MEDLINE | ID: mdl-34343264

ABSTRACT

Interictal epileptiform discharges (IEDs) are a widely used biomarker in patients with epilepsy but lack specificity. It has been proposed that there are truly epileptogenic and less pathological or even protective IEDs. Recent studies suggest that highly pathological IEDs are characterized by high-frequency oscillations (HFOs). Here, we aimed to dissect these 'HFO-IEDs' at the single-neuron level, hypothesizing that the underlying mechanisms are distinct from 'non-HFO-IEDs'. Analysing hybrid depth electrode recordings from patients with temporal lobe epilepsy, we found that single-unit firing rates were higher in HFO- than in non-HFO-IEDs. HFO-IEDs were characterized by a pronounced pre-peak increase in firing, which coincided with the preferential occurrence of HFOs, whereas in non-HFO-IEDs, there was only a mild pre-peak increase followed by a post-peak suppression. Comparing each unit's firing during HFO-IEDs to its baseline activity, we found many neurons with a significant increase during the HFO component or ascending part, but almost none with a decrease. No such imbalance was observed during non-HFO-IEDs. Finally, comparing each unit's firing directly between HFO- and non-HFO-IEDs, we found that most cells had higher rates during HFO-IEDs and, moreover, identified a distinct subset of neurons with a significant preference for this IED subtype. In summary, our study reveals that HFO- and non-HFO-IEDs have different single-unit correlates. In HFO-IEDs, many neurons are moderately activated, and some participate selectively, suggesting that both types of increased firing contribute to highly pathological IEDs.


Subject(s)
Action Potentials/physiology , Electrocorticography/methods , Epilepsy, Temporal Lobe/diagnosis , Epilepsy, Temporal Lobe/physiopathology , Neurons/physiology , Adult , Electrocorticography/instrumentation , Electrodes, Implanted , Female , Humans , Male , Middle Aged , Young Adult
20.
Epilepsia ; 62(10): 2307-2321, 2021 10.
Article in English | MEDLINE | ID: mdl-34420211

ABSTRACT

The Wearables for Epilepsy And Research (WEAR) International Study Group identified a set of methodology standards to guide research on wearable devices for seizure detection. We formed an international consortium of experts from clinical research, engineering, computer science, and data analytics at the beginning of 2020. The study protocols and practical experience acquired during the development of wearable research studies were discussed and analyzed during bi-weekly virtual meetings to highlight commonalities, strengths, and weaknesses, and to formulate recommendations. Seven major essential components of the experimental design were identified, and recommendations were formulated about: (1) description of study aims, (2) policies and agreements, (3) study population, (4) data collection and technical infrastructure, (5) devices, (6) reporting results, and (7) data sharing. Introducing a framework of methodology standards promotes optimal, accurate, and consistent data collection. It also guarantees that studies are generalizable and comparable, and that results can be replicated, validated, and shared.


Subject(s)
Epilepsy , Wearable Electronic Devices , Data Collection , Epilepsy/diagnosis , Humans , Research Design , Seizures/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...