Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
2.
Front Cardiovasc Med ; 9: 905614, 2022.
Article in English | MEDLINE | ID: mdl-35669476

ABSTRACT

Background: We describe a rare case of patent foramen ovale (PFO) associated stroke in a patient with pulmonary embolism, inferior vena cava thrombosis and undergoing filter implantation who successfully underwent PFO closure using the right internal jugular venous approach. Case Summary: This is a rare case of a 42-year-old patient who presented with stroke and pulmonary embolism and was diagnosed with a PFO, inferior vena cava thrombosis and underwent filter implantation. The patient suffered from stroke and pulmonary embolism successively; that is, embolic events occurred in both the arterial and venous systems. Transesophageal echocardiography (TEE) showed a PFO with an atrial septal aneurysm (ASA), which we considered a "pathological" PFO. Due to the obstructive nature of the inferior vena cava approach, we successfully performed PFO closure via the right internal jugular venous approach under the guidance of X-ray and transthoracic echocardiography (TTE). Discussion: The right jugular venous approach provides a simple technical solution for patients who require PFO closure when femoral venous access is unavailable, which can be performed under X-ray and TTE guidance.

3.
Heart Lung Circ ; 29(6): 914-920, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31402125

ABSTRACT

BACKGROUND: Multiple atrial septal defects (ASD) with an inferior sinus venosus defect (SVD) have always been considered to be contraindications for interventional therapy. On the basis of early experience using a patent ductus arteriosus (PDA) occluder for interventional treatment for inferior ASD, this study investigated the feasibility of transcatheter closure of multiple ASDs with an inferior SVD under the guidance of three-dimensional (3D) printed heart models. METHODS: Between August 2016 and February 2017, five patients who were diagnosed with multiple ASDs with an inferior SVD at the First Affiliated Hospital of Xi'an Jiaotong University underwent cardiac computed tomography (CT) scans and three-dimensional (3D) echocardiography to generate heart disease models by a 3D printing technique. The best occlusion program was determined through a simulated closure on the model. Percutaneous device closure of multiple ASDs with an inferior SVD was performed following the predetermined program, guided only by fluoroscopy. Follow-up included electrocardiography, transthoracic echocardiography, and transoesophageal echocardiography. RESULTS: Three-dimensional (3D) printed models for all five patients were produced successfully. Four (4) patients had a secundum ASD with an inferior sinus venosus ASD, and one patient had a patent foramen ovale (PFO) with an inferior sinus venosus ASD. All patients were successfully treated with interventional therapy. Inferior sinus venosus ASD was percutaneously closed using the PDA occluder, and the additional secundum ASD or PFO in each patient was percutaneously closed using an ASD or PFO occluder at the same time. There was no device embolisation, procedure-related death or pericardial tamponade. During the 1-year follow-up, a minor residual shunt was detected in one patient. CONCLUSION: The use of 3D printed ASD models provides a useful reference for transcatheter device closure of multiple ASD with an inferior SVD. This approach can provide a new treatment strategy for inferior sinus venosus ASD, which has been considered a contraindication for interventional therapy. However, long-term follow-up in a large number of patients is still warranted.


Subject(s)
Cardiac Catheterization/methods , Heart Septal Defects, Atrial/surgery , Printing, Three-Dimensional , Septal Occluder Device , Adult , Echocardiography, Doppler, Color/methods , Echocardiography, Transesophageal/methods , Feasibility Studies , Female , Follow-Up Studies , Heart Septal Defects, Atrial/diagnosis , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
5.
World J Clin Cases ; 7(5): 562-571, 2019 Mar 06.
Article in English | MEDLINE | ID: mdl-30863756

ABSTRACT

BACKGROUND: The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects (PmVSD) because of serious complications, such as heart block and tricuspid regurgitation (TR), associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable. AIM: To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus (PDA) occluder. METHODS: We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed. RESULTS: All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within 48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed. CONCLUSION: Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted.

6.
Ying Yong Sheng Tai Xue Bao ; 30(3): 1015-1024, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30912395

ABSTRACT

As the key and hot topic in landscape ecology, ecological security pattern plays an important role in maintaining regional ecological security and achieving regional sustainable development. Based on land use data of 2016, we used the InVEST model to evaluate the habitat quality of Tang County to determine the ecological source. The resistance surface was constructed by selecting the resistance factors such as land use type, habitat quality index, vegetation coverage, distance to water, distance to settlements, distance to roads, with the resistance threshold being used to partition the ecological security pattern. Finally, the ecological security pattern of Tang County was constructed by determining the ecological corridor with the MCR model. The results showed that the ecological source of Tang County accounted for 3.3% of the total area, mainly distributed in forest land and waters with large plaque area, and the Western Ocean Reservoir (one of the four major reservoirs in Hebei Province). According to the cost resistance mutation point, the research region could be divided into prohibited development zone, restricted development zone, optimized development zone, and key development zone. The percentage of each zone was 18.9%, 43.6%, 27.6% and 9.9%, respectively. The total length of the potential ecological corridors in Tang County was 333.52 km, and was 263.91 km after optimization, which was helpful for various ecological exchanges. Our results had important guiding significance for the rational and sustainable use of land resources in Tang County, and could provide theoretical and technical supports for the decision-making of land planning and layout in Tang County.


Subject(s)
Ecosystem , China , Forests
7.
World J Clin Cases ; 6(15): 916-921, 2018 Dec 06.
Article in English | MEDLINE | ID: mdl-30568946

ABSTRACT

AIM: To test the potential association between atrial septal aneurysm (ASA) and migraine in patent foramen ovale (PFO) closure patients through an observational, single-center, case-controlled study. METHODS: We studied a total of 450 migraineurs who had right-to-left shunts and underwent PFO closure in a retrospective single-center non-randomized registry from February 2012 to October 2016 on the condition that they were aged 18-45 years old. Migraine was diagnosed according to the International Classification of Headache Disorders, 3rd edition and evaluated using the Headache Impact Test-6 (HIT-6). All patients underwent preoperative transesophageal echocardiography, contrast transthoracic echocardiography, and computed tomography or magnetic resonance imaging examinations, with subsequent fluoroscopy-guided PFO closure. Based on whether they have ASA or not, the patients were divided into two groups: A (PFO with ASA, n = 80) and B (PFO without ASA, n = 370). Baseline characteristics and procedural and follow-up data were reviewed. RESULTS: Compared to group B, group A had an increased frequency of ischemic lesions (11.3% vs 6.2%, P = 0.038) and migraine with aura (32.5% vs 21.1%, P = 0.040). The PFO size was significantly larger in group A (P = 0.007). There was no significant difference in HIT-6 scores between the two groups before and at the one-year follow-up after the PFO closure [61 (9) vs 63 (9), P = 0.227; 36 (13) vs 36 (10), P = 0.706]. CONCLUSION: Despite its small sample size, our study suggests that the prevalence of ASA in PFO with migraine patients is associated with ischemic stroke, larger PFO size, and migraine with aura.

8.
Clinics (Sao Paulo) ; 73: e371, 2018 11 29.
Article in English | MEDLINE | ID: mdl-30517278

ABSTRACT

OBJECTIVE: Explore the feasibility and safety of transcatheter closure of perimembranous ventricular septal defects using a wire-drifting technique (WT) in children. METHODS: We retrospectively analyzed 121 pediatric patients diagnosed with perimembranous ventricular septal defects who underwent interventional treatment at the First Affiliated Hospital of Xi'an Jiaotong University from Dec 2011 to Dec 2014. Based on the method used for arteriovenous loop establishment during the procedure, the patients were divided into a conventional technique (CT) group and a WT group. RESULTS: In total, 51 of the 53 patients (96.2%) in the CT group and 66 of the 68 patients (97.1%) in the WT group achieved procedural success, with no significant difference between the two groups (p>0.05). The CT group showed a nonsignificantly higher one-time success rate of arteriovenous loop establishment (94.3% vs. 91.2%, p>0.05). The procedure time was 46.0 (14.0) min and 46.5 (10.0) min in the CT and WT groups, respectively. The CT procedure was discontinued in the 2 cases (3.8%) of intraprocedural atrioventricular block in the CT group. In the one case (1.9%) of postprocedural atrioventricular block in the CT group, a permanent pacemaker was implanted to resolve third-degree atrioventricular block three months after the procedure. In the WT group, no cases of intraprocedural atrioventricular block occurred, and one case (1.5%) of postprocedural atrioventricular block occurred. In this case, intravenous dexamethasone injection for three days returned the sinus rhythm to normal. Aggravated mild to moderate tricuspid regurgitation was observed in 2 patients (3.8%) in the CT group during the 2-year follow-up period; aggravated tricuspid regurgitation was not observed in the WT group. During the 2-year follow-up period, there was no evidence of residual shunting in either group. CONCLUSION: Transcatheter closure of perimembranous ventricular septal defects with the WT is safe and effective in children.


Subject(s)
Cardiac Catheterization/methods , Heart Septal Defects, Ventricular/surgery , Adolescent , Arteriovenous Shunt, Surgical/methods , Cardiac Catheterization/instrumentation , Child , Child, Preschool , Coronary Angiography/methods , Echocardiography , Female , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Ventricles/diagnostic imaging , Humans , Male , Reproducibility of Results , Retrospective Studies , Septal Occluder Device , Statistics, Nonparametric , Treatment Outcome
9.
Clinics ; 73: e371, 2018. tab, graf
Article in English | LILACS | ID: biblio-974921

ABSTRACT

OBJECTIVE: Explore the feasibility and safety of transcatheter closure of perimembranous ventricular septal defects using a wire-drifting technique (WT) in children. METHODS: We retrospectively analyzed 121 pediatric patients diagnosed with perimembranous ventricular septal defects who underwent interventional treatment at the First Affiliated Hospital of Xi'an Jiaotong University from Dec 2011 to Dec 2014. Based on the method used for arteriovenous loop establishment during the procedure, the patients were divided into a conventional technique (CT) group and a WT group. RESULTS: In total, 51 of the 53 patients (96.2%) in the CT group and 66 of the 68 patients (97.1%) in the WT group achieved procedural success, with no significant difference between the two groups (p>0.05). The CT group showed a nonsignificantly higher one-time success rate of arteriovenous loop establishment (94.3% vs. 91.2%, p>0.05). The procedure time was 46.0 (14.0) min and 46.5 (10.0) min in the CT and WT groups, respectively. The CT procedure was discontinued in the 2 cases (3.8%) of intraprocedural atrioventricular block in the CT group. In the one case (1.9%) of postprocedural atrioventricular block in the CT group, a permanent pacemaker was implanted to resolve third-degree atrioventricular block three months after the procedure. In the WT group, no cases of intraprocedural atrioventricular block occurred, and one case (1.5%) of postprocedural atrioventricular block occurred. In this case, intravenous dexamethasone injection for three days returned the sinus rhythm to normal. Aggravated mild to moderate tricuspid regurgitation was observed in 2 patients (3.8%) in the CT group during the 2-year follow-up period; aggravated tricuspid regurgitation was not observed in the WT group. During the 2-year follow-up period, there was no evidence of residual shunting in either group. CONCLUSION: Transcatheter closure of perimembranous ventricular septal defects with the WT is safe and effective in children.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Cardiac Catheterization/methods , Heart Septal Defects, Ventricular/surgery , Arteriovenous Shunt, Surgical/methods , Echocardiography , Cardiac Catheterization/instrumentation , Reproducibility of Results , Retrospective Studies , Treatment Outcome , Coronary Angiography/methods , Statistics, Nonparametric , Septal Occluder Device , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Ventricles/diagnostic imaging
11.
J Interv Cardiol ; 30(4): 362-367, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28568903

ABSTRACT

OBJECTIVES: To describe the multidisciplinary assessment of patent foramen ovale (PFO) with substantial right-to-left shunting (RLS) and medium-term follow-up after PFO closure for stroke or transient ischemic attack (TIA). BACKGROUND: PFO closure is a therapeutic option to prevent recurrent ischemic event in patients with cryptogenic stroke and TIA. The apparent lack of benefit seen in previous studies was in part due to the inclusion of patients with alternate mechanisms of stroke/TIA. However, the long-term follow-up results of RESPECT trial confirmed that PFO closure could reduce the recurrence rate of stroke compared to medical therapy. The obvious difference between RESPECT and the other studies is that RESPECT recruited more relevant patients with substantial RLS. METHODS: From May 2013 to October 2015, all subjects diagnosed as cryptogenic stroke or TIA with substantial RLS who underwent PFO closure at our institution were included. All patients underwent multidisciplinary assessment to exclude stroke/TIA with definite etiology. Baseline characteristics, clinical manifestations, procedural, and follow-up data were reviewed. RESULTS: A total of 219 consecutive patients with substantial RLS undergoing PFO closure were identified. There were no procedure-related deaths, strokes, or TIA. Mean follow-up was 2.0 ± 0.7 years. Early residual shunting was visible in 9 patients (4.1%); however, during follow-up, only 3 patients (1.4%) had residual RLS detected by contrast transthoracic echocardiography (cTTE). The annual risk of recurrent ischemic stroke or TIA was 0.457%. CONCLUSIONS: PFO closure can be performed safely and effectively in patients with cryptogenic stroke or TIA. In selected patients with substantial RLS, following appropriate multidisciplinary assessment, excellent results with low incidence of recurrent events may be achieved.


Subject(s)
Foramen Ovale, Patent/surgery , Ischemic Attack, Transient/epidemiology , Septal Occluder Device , Stroke/epidemiology , Adult , Aged , Cardiac Catheterization , Cohort Studies , Echocardiography , Female , Foramen Ovale, Patent/diagnosis , Humans , Ischemic Attack, Transient/diagnosis , Ischemic Attack, Transient/prevention & control , Male , Middle Aged , Patient Selection , Recurrence , Stroke/diagnosis , Stroke/prevention & control , Treatment Outcome
12.
J Geriatr Cardiol ; 12(3): 323-5, 2015 May.
Article in English | MEDLINE | ID: mdl-26089859

ABSTRACT

Platypnea orthodeoxia syndrome is associated with dyspnea and arterial oxygen desaturation accentuated by an upright posture. It can be secondary to an intracardiac shunt. We report a case of platypnea-orthodeoxia syndrome (POS) in a 58-year old male patient who had a pre-existing patent foramen ovale (PFO) and substantial pulmonary pathologies. He was successfully treated by percutaneous transcatheter closure of the PFO. Our case highlights the importance of recognition of this rare syndrome in patients who present with unexplained hypoxia for whom transcatheter closure of the interatrial shunt can be safely carried out.

13.
Zhonghua Xin Xue Guan Bing Za Zhi ; 37(11): 981-5, 2009 Nov.
Article in Chinese | MEDLINE | ID: mdl-20137320

ABSTRACT

OBJECTIVE: To analyze factors influencing the choice of atrial septal occluder (ASO) for transcatheter closure of patients with secundum atrial septal defect (ASD). METHODS: A total of 1114 ASD patients [388 males, aged from 2 to 75 years, mean age (26.3 +/- 17.0) years] were enrolled. Patients were divided to adult (> 14 years, mean 34.4 years, n = 779) and child (< or = 14 years, mean 7.3 years, n = 335) groups. ASD size in different ultrasound cross-sections was determined by transthoracic echocardiography (TTE). ASO size was chosen on the basis of the maximum diameter of the defect (MD). Defect-shapes and rim lengths of ASD, the difference choice of ASO in the two groups were compared. RESULTS: MD of the defects ranged from 5 to 40 mm [mean (19.7 +/- 7.8) mm]. ASD was successfully occluded in 1085 out of 1114 patients (97.4%). Occluder size ranged from 6 to 46 mm [mean (25.8 +/- 8.9) mm] and the difference between occluder size and MD ranged from 2 to 10 mm [mean (6.1 +/- 3.4) mm, ASO/MD ratio 1.3:1]. Though the diameter of the defect was similar between the 2 groups, the size of occluder was significantly larger in adult group than that in child group (ASO/MD ratio 1.1 - 1.6:1 vs. 1.2 - 1.8:1, P < 0.05). MD was significantly correlated with ASO in both groups (r = 0.911 and r = 0.944 in adults and child groups, respectively, all P < 0.01). The size and increment of the occluder used in patients with deficient anterior rims was significantly bigger than patients with sufficient anterior rims (P < 0.01). CONCLUSION: The maximum diameter of the defect was the major determinant for selecting occluder size and choice of occluder size was also influenced by patient age, defect-shape and defect rim for transcatheter closure of secundum ASD.


Subject(s)
Cardiac Catheterization/instrumentation , Heart Septal Defects, Atrial/therapy , Physicians/psychology , Septal Occluder Device , Adolescent , Adult , Age Factors , Aged , Child , Child, Preschool , Echocardiography , Female , Humans , Male , Middle Aged , Practice Patterns, Physicians' , Prosthesis Design , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...