Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Med ; 85(4): 2160-2173, 2021 04.
Article in English | MEDLINE | ID: mdl-33017076

ABSTRACT

PURPOSE: Diffusion and lung morphometry imaging using hyperpolarized gases are promising tools to quantify pulmonary microstructure noninvasively in humans and in animal models. These techniques assume the motion encoded is exclusively diffusive gas displacement, but the impact of cardiac motion on measurements has never been explored. Furthermore, although diffusion morphometry has been validated against histology in humans and mice using 3 He, it has never been validated in mice for 129 Xe. Here, we examine the effect of cardiac motion on diffusion imaging and validate 129 Xe diffusion morphometry in mice. THEORY AND METHODS: Mice were imaged using gradient-echo-based diffusion imaging, and apparent diffusion-coefficient (ADC) maps were generated with and without cardiac gating. Diffusion-weighted images were fit to a previously developed theoretical model using Bayesian probability theory, producing morphometric parameters that were compared with conventional histology. RESULTS: Cardiac gating had no significant impact on ADC measurements (dual-gating: ADC = 0.020 cm2 /s, single-gating: ADC = 0.020 cm2 /s; P = .38). Diffusion-morphometry-generated maps of ADC (mean, 0.0165 ± 0.0001 cm2 /s) and acinar dimensions (alveolar sleeve depth [h] = 44 µm, acinar duct radii [R] = 99 µm, mean linear intercept [Lm ] = 74 µm) that agreed well with conventional histology (h = 45 µm, R = 108 µm, Lm = 63 µm). CONCLUSION: Cardiac motion has negligible impact on 129 Xe ADC measurements in mice, arguing its impact will be similarly minimal in humans, where relative cardiac motion is reduced. Hyperpolarized 129 Xe diffusion morphometry accurately and noninvasively maps the dimensions of lung microstructure, suggesting it can quantify the pulmonary microstructure in mouse models of lung disease.


Subject(s)
Diffusion Magnetic Resonance Imaging , Xenon Isotopes , Animals , Bayes Theorem , Diffusion , Helium , Lung/diagnostic imaging , Male , Mice
2.
J Magn Reson ; 295: 63-71, 2018 10.
Article in English | MEDLINE | ID: mdl-30125865

ABSTRACT

Hyperpolarized (HP) 129Xe MRI is emerging as a powerful, non-invasive method to image lung function and is beginning to find clinical application across a range of conditions. As clinical implementation progresses, it becomes important to translate back to well-defined animal models, where novel disease signatures can be characterized longitudinally and validated against histology. To date, preclinical 129Xe MRI has been limited to only a few sites worldwide with 2D imaging that is not generally sufficient to fully capture the heterogeneity of lung disease. To address these limitations and facilitate broader dissemination, we report on a compact and portable HP gas ventilator that integrates all the gas-delivery and physiologic monitoring capabilities required for high-resolution 3D hyperpolarized 129Xe imaging. This ventilator is MR- and HP-gas compatible, driven by inexpensive microcontrollers and open source code, and allows for precise control of the tidal volume and breathing cycle in perorally intubated mice and rats. We use the system to demonstrate data acquisition over multiple breath-holds, during which lung motion is suspended to enable high-resolution 3D imaging of gas-phase and dissolved-phase 129Xe in the lungs. We demonstrate the portability and versatility of the ventilator by imaging a mouse model of lung cancer longitudinally at 2 Tesla, and a healthy rat at 7 Tesla. We also report the detection of subtle spectroscopic fluctuations in phase with the heart rate, superimposed onto larger variations stemming from the respiratory cycle. This ventilator was developed to facilitate duplication and gain broad adoption to accelerate preclinical 129Xe MRI research.


Subject(s)
Lung/diagnostic imaging , Magnetic Resonance Imaging/methods , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Ventilators, Mechanical , Xenon/pharmacokinetics , Animals , Heart Rate , Lung/physiology , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/physiopathology , Mice , Rats , Respiratory Mechanics , Xenon Isotopes
SELECTION OF CITATIONS
SEARCH DETAIL
...