ABSTRACT
Objective: To study the extent of left ventricular (LV) mass regression in aortic stenosis after aortic valve replacement with the TTK Chitra™ tilting disc valve. Methods and materials: This study included patients with severe isolated aortic stenosis (AS), admitted in our department. They had aortic valve replacement (AVR) with the TTK Chitra™ tilting disc valve, between January 2008 and December 2010. Data were collected from consecutive forty-eight patients. LV mass and diametric and functional parameters were recorded preoperatively and compared with echocardiography after 3 months, 6 months, then yearly, up to 3 years. Results: 70.8% of the patients were males and 29.2% were females. The mean duration of illness was 37.92 ± 25.87 months. The mean LV ejection fraction increased 3 months after surgery (61.56 ± 10.10% to 69.31 ± 9.34%) with a sustained increase for the next 3 years. The mean LV end-diastolic diameter decreased (50.16 ± 6.05 mm to 45.69 ± 5.93 mm) after 3 months of surgery, with a sustained decrease for the next 3 years. The mean LV end-systolic diameter decreased (32.84 ± 6.96 mm to 29.41 ± 5.86 mm) after 3 months of surgery and then showed a sustained decrease for the next 3 years. The LV mass assessed with echocardiography regressed from 324.65 ± 97.77 g before surgery to 252.64 ± 71.12 g after 3 months and then showed a sustained decrease over the next 3 years. Conclusion: Significant LV mass regression occurred after AVR with the TTK Chitra™ valve. The maximum reversal was found to be within the first 3 months after surgery with sustained beneficial improvement for the next 3 years.
ABSTRACT
BACKGROUND: Hyperhomocysteinemia is associated with an increased risk for cardiovascular diseases. The influence of hyperhomocysteinemia on post-operative events, after coronary artery bypass surgery graft, is less studied. METHODS: This cross-sectional study aimed to determine if hyperhomocysteinemia was associated with post-operative complications in patients < 50 years who underwent off-pump coronary artery bypass graft for coronary artery disease. A set of major post-operative complications were considered as primary outcome measures. The independent effect of hyperhomocysteinemia and other risk factors in the incidence of post-operative complications was determined by multivariate analysis. RESULTS: The mean homocysteine levels among the study participants who had post-operative complications were significantly higher than those without post-operative complications (17.37â mmol/L vs. 12.84â mmol/L). On multivariate analysis, hyperhomocysteinemia, diabetes mellitus, and higher body mass index (> 25) were significant predictors of adverse events during the post-operative period. CONCLUSION: Hyperhomocysteinemia was a significant predictor of immediate post-operative adverse events after coronary artery bypass surgery graft. Necessary precautions and management strategies have to be evolved for these high-risk subsets.